<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN" "JATS-journalpublishing1-4.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.4" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">Oalib</journal-id>
      <journal-title-group>
        <journal-title>Open Access Library Journal</journal-title>
      </journal-title-group>
      <issn pub-type="epub">2333-9721</issn>
      <issn pub-type="ppub">2333-9705</issn>
      <publisher>
        <publisher-name>Scientific Research Publishing</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.4236/oalib.1115812</article-id>
      <article-id pub-id-type="publisher-id">Oalib-153423</article-id>
      <article-categories>
        <subj-group>
          <subject>Article</subject>
        </subj-group>
        <subj-group>
          <subject>Biomedical</subject>
          <subject>Life Sciences</subject>
          <subject>Business</subject>
          <subject>Economics</subject>
          <subject>Chemistry</subject>
          <subject>Materials Science</subject>
          <subject>Computer Science</subject>
          <subject>Communications</subject>
          <subject>Earth</subject>
          <subject>Environmental Sciences</subject>
          <subject>Engineering</subject>
          <subject>Medicine</subject>
          <subject>Healthcare</subject>
          <subject>Physics</subject>
          <subject>Mathematics</subject>
          <subject>Social Sciences</subject>
          <subject>Humanities</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Robotic System with Haptic Feedback for Intelligent Coronary Stent Implantation in Percutaneous Coronary Intervention</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Zhang</surname>
            <given-names>Yingxin</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Yin</surname>
            <given-names>Meiqi</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Deng</surname>
            <given-names>Dandan</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="aff1"><label>1</label> College of Engineering, Robot Engineering, Zhejiang Normal University, Jinhua, China </aff>
      <author-notes>
        <fn fn-type="conflict" id="fn-conflict">
          <p>The authors declare no conflicts of interest.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub">
        <day>03</day>
        <month>08</month>
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="collection">
        <month>08</month>
        <year>2026</year>
      </pub-date>
      <volume>13</volume>
      <issue>08</issue>
      <fpage>1</fpage>
      <lpage>8</lpage>
      <history>
        <date date-type="received">
          <day>27</day>
          <month>07</month>
          <year>2026</year>
        </date>
        <date date-type="accepted">
          <day>23</day>
          <month>08</month>
          <year>2026</year>
        </date>
        <date date-type="published">
          <day>26</day>
          <month>08</month>
          <year>2026</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2026 by the authors and Scientific Research Publishing Inc.</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="open-access">
          <license-p> This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link> ). </license-p>
        </license>
      </permissions>
      <self-uri content-type="doi" xlink:href="https://doi.org/10.4236/oalib.1115812">https://doi.org/10.4236/oalib.1115812</self-uri>
      <abstract>
        <p>Traditional percutaneous coronary intervention (PCI) exposes interventional cardiologists to long-term X-ray radiation and musculoskeletal injuries caused by lead aprons. Hand tremor during manual operation also leads to insufficient positioning accuracy of stent deployment, increasing risks of stent malapposition and in-stent restenosis. To address these limitations, this paper develops a master-slave teleoperated robotic system for intelligent coronary stent implantation. The platform consists of a surgeon master console, bedside slave manipulator, real-time force sensing module, and image navigation upper computer subsystem. The slave robot realizes multi-degree-of-freedom coordinated control of axial translation and rotation for guidewires, balloon catheters and stent delivery systems. A high-precision force sensor is integrated to detect vessel contact force at the catheter path, and an impedance-based haptic teleoperation algorithm is proposed. Combined with coronary angiography visualization, targeted positioning of stent deployment zones is realized. A segmented motion control strategy is designed for different PCI stages, enabling automatic velocity reduction during stent positioning and release. <italic>In-vitro</italic> experiments are carried out on a silicone coronary phantom with simulated vascular stenosis. Results demonstrate that the average axial positioning error reaches 0.32 mm, and the rotational angle error is less than 0.45˚. Two-level force thresholds are embedded in the control loop; the system actively limits pushing force to prevent vascular dissection or perforation when excessive contact occurs. Compared with manual operation, the robotic system eliminates radiation exposure for operators and improves positioning repeatability during stent implantation. Phantom experiments verify the mechanical stability and control performance of the proposed system, providing a feasible design scheme for next-generation intelligent interventional robotic platforms.</p>
      </abstract>
      <kwd-group kwd-group-type="author-generated" xml:lang="en">
        <kwd>Coronary Interventional Robot</kwd>
        <kwd>Stent Implantation</kwd>
        <kwd>Master-Slave Teleoperation</kwd>
        <kwd>Haptic Force Feedback</kwd>
        <kwd>Percutaneous Coronary Intervention</kwd>
        <kwd>Vascular Phantom</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>1. Introduction</title>
      <p>Coronary artery disease (CAD) remains one of the leading causes of mortality worldwide. Percutaneous coronary intervention (PCI) has become the primary minimally invasive revascularization strategy for symptomatic CAD patients. In conventional PCI procedures, physicians manipulate guidewires, balloons and stent catheters under continuous fluoroscopic guidance. Long-term occupational radiation exposure raises risks of cataracts and malignant tumors, while heavy lead garments trigger chronic lumbar and cervical lesions [<xref ref-type="bibr" rid="B1">1</xref>]. In addition, physiological hand tremors degrade manipulation precision. For complex lesions such as chronic total occlusion (CTO) and severely calcified vessels, inaccurate stent positioning easily causes geographic miss and poor long-term prognosis.</p>
      <p>In recent decades, robotic endovascular intervention has attracted extensive attention in medical device research. Commercial robotic PCI systems including CorPath GRX and R-One have entered clinical use [<xref ref-type="bibr" rid="B2">2</xref>]. These platforms realize remote catheter manipulation, but obvious drawbacks remain: most systems lack native real-time haptic feedback; physicians rely only on fluoroscopic images to judge catheter–vessel interaction. Automatic intelligent constraints for stent release are insufficient, and the coordination between imaging navigation and robotic motion control needs further improvement. Domestic prototypes such as ALLVAS and ETcath200 have completed preclinical trials, yet integrated control strategies oriented toward precise stent deployment are still under exploration.</p>
      <p>In parallel, academic communities have studied continuum soft robots, magnetic navigation systems and force sensing catheters [<xref ref-type="bibr" rid="B3">3</xref>]. Magnetic navigation robots can steer guidewires inside tortuous vessels, but they cannot directly complete stent delivery and expansion. Many existing teleoperation prototypes only focus on position tracking, ignoring safety protection against excessive contact force that may damage vascular endothelium [<xref ref-type="bibr" rid="B4">4</xref>].</p>
      <p>This work constructs an integrated intelligent robotic platform dedicated to coronary stent implantation. The main contributions are summarized as follows:</p>
      <p>1) A modular master-slave robotic system compatible with clinical standard PCI consumables is established, integrating force sensing and haptic feedback;</p>
      <p>2) An impedance-based teleoperation control algorithm with force limiting safety mechanism is proposed to avoid over-pushing injuries;</p>
      <p>3) A segmented motion control framework is developed for the whole PCI workflow, adopting low-speed fine-tuning mode in stent positioning and release phase; </p>
      <p>4) <italic>In-vitro</italic> phantom experiments are performed to evaluate positioning accuracy, force tracking performance and overall surgical workflow feasibility.</p>
    </sec>
    <sec id="sec2">
      <title>2. System Overview</title>
      <p>The robotic system contains four core subsystems: master haptic console, bedside slave manipulator, force sensing unit, and upper computer control &amp; angiography navigation module. Real-time Ethernet communication is adopted with a control cycle of 1 ms to reduce teleoperation delay [<xref ref-type="bibr" rid="B5">5</xref>]. The overall architecture is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref><xref ref-type="fig" rid="fig1">Figure 1</xref>.</p>
      <fig id="fig1">
        <label>Figure 1</label>
        <graphic xlink:href="https://html.scirp.org/file/1115812-rId15.jpeg?20260826014713" />
      </fig>
      <p><bold>Figure 1.</bold> Schematic diagram showing the overall architecture of the robotic system.</p>
      <sec id="sec2dot1">
        <title>2.1. Slave Manipulator Design</title>
        <p>The slave robot provides three fundamental degrees of freedom: guidewire axial feed, catheter axial feed, and continuous catheter rotation. Servo motors and timing belt transmission are adopted to achieve compact layout suitable for limited space in catheter laboratories [<xref ref-type="bibr" rid="B6">6</xref>]. Key mechanical specifications: Maximum travel: 180 mm; Adjustable feed speed: 0 - 15 mm/s (0 - 3 mm/s fine mode for stent deployment); Rotation range: 0˚ - 360˚ continuous rotation; Repetitive positioning accuracy ≤ 0.1 mm.</p>
        <p>A disposable sterile cassette mechanism is designed for rapid assembly before surgery to avoid cross-contamination. Elastic roller clamping ensures stable fixation without scratching the outer surface of clinical catheters.</p>
      </sec>
      <sec id="sec2dot2">
        <title>2.2. Master Haptic Console</title>
        <p>The master manipulator adopts impedance-type haptic handles. Vascular contact force detected on the slave side is mapped to the operator’s hand in real time. Resistance feedback is generated when the catheter touches vascular walls or stenotic lesions, restoring natural operation sensation similar to manual PCI [<xref ref-type="bibr" rid="B7">7</xref>].</p>
      </sec>
      <sec id="sec2dot3">
        <title>2.3. Force Sensing Module</title>
        <p>A miniature high-precision load cell is installed along the catheter access path. Measuring range: 0 - 5 N, resolution: 0.01 N. According to clinical PCI experience, safe contact force between catheter and coronary vessel is recommended below 0.8 N; forces exceeding 1.2 N significantly increase risks of intimal injury. Two threshold strategies are implemented: warning threshold = 0.8 N, limiting threshold = 1.2 N. Once the limiting threshold is reached, the robot automatically reduces feed speed; sustained overload triggers temporary stop of propulsion [<xref ref-type="bibr" rid="B8">8</xref>].</p>
      </sec>
      <sec id="sec2dot4">
        <title>2.4. Software and Hardware Platform</title>
        <p>The underlying motion controller is based on STM32 microcontrollers, and the upper computer runs on an industrial PC [<xref ref-type="bibr" rid="B9">9</xref>]. Human–machine interface is developed based on Qt, supporting motion parameter configuration, real-time force curve display, DICOM angiogram loading, lesion marking and surgical data recording. The software framework consists of servo driving layer, communication layer, control algorithm layer and visualization interaction layer.</p>
      </sec>
    </sec>
    <sec id="sec3">
      <title>3. Teleoperation Control Algorithm</title>
      <sec id="sec3dot1">
        <title>3.1. Master-Slave Position Mapping</title>
        <p>Define the master workspace coordinate <italic>X</italic><italic>ₘ</italic> and slave actuator coordinate <italic>X</italic><italic>ₛ</italic>. A linear scaling mapping is established as the relational expression: <italic>X</italic><italic>ₛ</italic> = <italic>k</italic> ∙ <italic>X</italic><italic>ₘ</italic> where <italic>k</italic> represents the scaling factor adjustable by operators [<xref ref-type="bibr" rid="B10">10</xref>]. A smaller scaling factor is adopted during stent positioning to realize precise micro-manipulation.</p>
      </sec>
      <sec id="sec3dot2">
        <title>3.2. Segmented Control Strategy for Stent Implantation</title>
        <p>The whole stent delivery workflow is divided into three stages with automatic parameter switching:</p>
        <p>1) Vascular access stage: high allowable speed for rapid catheter advancement;</p>
        <p>2) Lesion approaching stage: velocity reduction and force warning activation;</p>
        <p>3) Stent positioning and deployment stage: minimum speed mode, increased haptic gain and restricted large-amplitude rotation to guarantee accurate alignment.</p>
      </sec>
    </sec>
    <sec id="sec4">
      <title>
        4.
        <italic>In-Vitro</italic>
        Experimental Validation
      </title>
      <sec id="sec4dot1">
        <title>4.1. Experimental Setup</title>
        <p>The test platform includes: silicone phantom mimicking coronary artery branches with 70% and 90% simulated stenosis; circulating pump simulating hemodynamic pressure; commercial guidewires, balloon catheters and drug-eluting stents; laser displacement sensor, multi-channel force acquisition system and the proposed robotic prototype [<xref ref-type="bibr" rid="B11">11</xref>].</p>
      </sec>
      <sec id="sec4dot2">
        <title>4.2. Experimental Schemes</title>
        <p>Three groups of experiments are designed: positioning accuracy test, force tracking &amp; safety protection test, and complete simulated PCI workflow test [<xref ref-type="bibr" rid="B12">12</xref>]. Each test is repeated 2 times for statistical averaging.</p>
      </sec>
      <sec id="sec4dot3">
        <title>4.3. Results and Analysis</title>
        <p>4.3.1. Positioning Accuracy</p>
        <p>Target displacements of 5 mm, 10 mm and 20 mm are set. The measured average axial positioning error is 0.32 mm with maximum error 0.57˚. The average rotational error is 0.31˚, maximum 0.45˚ [<xref ref-type="bibr" rid="B13">13</xref>]. The accuracy satisfies clinical requirements (positioning error &lt; 1 mm for stent implantation).</p>
        <p>4.3.2. Force Safety Test</p>
        <p>Continuous automatic propulsion is set to simulate catheter collision with stenotic lesions. The system triggers warning at 0.8 N. When contact force reaches 1.2 N, propulsion speed decreases rapidly and eventually stops. The overload protection function effectively limits excessive thrust [<xref ref-type="bibr" rid="B14">14</xref>].</p>
        <p>4.3.3. Simulated Stent Implantation</p>
        <p>Complete procedures including guidewire crossing, predilation, stent delivery and deployment are implemented on the phantom [<xref ref-type="bibr" rid="B15">15</xref>]. Operators can distinguish normal vascular segments and stenotic regions via haptic cues. Compared with manual manipulation, the robotic system suppresses hand tremor and improves repeatability of stent deployment position [<xref ref-type="bibr" rid="B2">2</xref>].</p>
      </sec>
      <sec id="sec4dot4">
        <title>
          4.4. Limitations of
          <italic>I</italic>
          <italic>n-Vitro</italic>
          Tests
        </title>
        <p>All experiments are conducted on static silicone phantoms. The mechanical properties differ from <italic>in-vivo</italic> pulsating coronary arteries. Further animal tests under physiological blood flow and cardiac motion are required to validate system robustness [<xref ref-type="bibr" rid="B16">16</xref>].</p>
      </sec>
    </sec>
    <sec id="sec5">
      <title>5. Discussion</title>
      <sec id="sec5dot1">
        <title>5.1. Advantages of the Proposed System</title>
        <p>1) Remote operation enables physicians to work outside fluoroscopy rooms, eliminating occupational radiation hazards;</p>
        <p>2) Closed-loop proximal force sensing and haptic feedback solve the missing tactile information problem of mainstream commercial robots;</p>
        <p>3) Segmented intelligent control strategy is specially optimized for stent deployment procedures;</p>
        <p>4) Modular mechanical design facilitates disinfection and compatibility with existing catheter room facilities.</p>
      </sec>
      <sec id="sec5dot2">
        <title>5.2. Existing Limitations</title>
        <p>This system belongs to an extracorporeal catheter-driving robot without onboard distal actuation [<xref ref-type="bibr" rid="B17">17</xref>]. Active bending inside vessels cannot be realized. For extremely tortuous and heavily calcified lesions, operation still relies on surgeon experience. At present, only 2D angiography is used. Future work will integrate IVUS and OCT multimodal imaging registration [<xref ref-type="bibr" rid="B18">18</xref>]. The platform remains human-in-the-loop teleoperation; fully autonomous stent implantation requires further exploration [<xref ref-type="bibr" rid="B19">19</xref>].</p>
      </sec>
      <sec id="sec5dot3">
        <title>5.3. Future Directions</title>
        <p>1) Multimodal registration of angiography, IVUS and OCT to realize automatic lesion measurement and stent size matching;</p>
        <p>2) Introduce deep learning for preoperative path planning to achieve semi-autonomous navigation;</p>
        <p>3) Develop integrated soft continuum robotic catheters with distal steering capability;</p>
        <p>4) Combine intelligent sensing stents to realize “robotic precise implantation + long-term postoperative vascular monitoring”.</p>
      </sec>
    </sec>
    <sec id="sec6">
      <title>6. Conclusion</title>
      <p>This paper presents a master-slave teleoperated robotic system for intelligent coronary stent implantation. Mechanical structure, hardware circuit and impedance-based haptic control algorithm are fully designed [<xref ref-type="bibr" rid="B20">20</xref>]. The robot realizes multi-degree-of-freedom coordinated driving of interventional devices, equipped with overload force protection and segmented motion control for stent release. <italic>In-vitro</italic> phantom experiments verify that the system achieves clinically acceptable positioning accuracy and can effectively prevent vascular injury caused by over-pushing [<xref ref-type="bibr" rid="B21">21</xref>]. The robotic platform allows remote PCI operation to avoid radiation exposure and improves the stability of stent implantation. Future work will focus on multimodal image navigation and <italic>in-vivo</italic> animal trials to promote clinical translation for minimally invasive cardiovascular interventions. </p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Weisz, G., Metzger, D.C., Caputo, R.P., Delgado, J.A., Marshall, J.J., Vetrovec, G.W., <italic>et al</italic>. (2013) Safety and Feasibility of Robotic Percutaneous Coronary Intervention. <italic>Journal</italic><italic>of</italic><italic>the</italic><italic>American</italic><italic>College</italic><italic>of</italic><italic>Cardiology</italic>, 61, 1596-1600. https://doi.org/10.1016/j.jacc.2012.12.045 <pub-id pub-id-type="doi">10.1016/j.jacc.2012.12.045</pub-id><pub-id pub-id-type="pmid">23500318</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jacc.2012.12.045">https://doi.org/10.1016/j.jacc.2012.12.045</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Weisz, G.</string-name>
              <string-name>Metzger, D.C.</string-name>
              <string-name>Caputo, R.P.</string-name>
              <string-name>Delgado, J.A.</string-name>
              <string-name>Marshall, J.J.</string-name>
              <string-name>Vetrovec, G.W.</string-name>
            </person-group>
            <year>2013</year>
            <article-title>Safety and Feasibility of Robotic Percutaneous Coronary Intervention</article-title>
            <source>Journal of the American College of Cardiology</source>
            <volume>61</volume>
            <pub-id pub-id-type="doi">10.1016/j.jacc.2012.12.045</pub-id>
            <pub-id pub-id-type="pmid">23500318</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B2">
        <label>2.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Chakravartti, J. and Rao, S.V. (2019) Robotic Assisted Percutaneous Coronary Intervention: Hype or Hope? <italic>Journal of the American Heart Association</italic>, 8, e012743. https://doi.org/10.1161/jaha.119.012743 <pub-id pub-id-type="doi">10.1161/jaha.119.012743</pub-id><pub-id pub-id-type="pmid">31257969</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1161/jaha.119.012743">https://doi.org/10.1161/jaha.119.012743</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Chakravartti, J.</string-name>
              <string-name>Rao, S.V.</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Robotic Assisted Percutaneous Coronary Intervention: Hype or Hope? Journal of the American Heart Association, 8, e012743</article-title>
            <pub-id pub-id-type="doi">10.1161/jaha.119.012743</pub-id>
            <pub-id pub-id-type="pmid">31257969</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B3">
        <label>3.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Alekseeva, N.M., Viller, A.G. and Romanov, A.M. (2025) The Design of Endovascular Robots for Cardiac Interventions: A Survey. <italic>Journal</italic><italic>of</italic><italic>Field</italic><italic>Robotics</italic>, 42, 1914-1962. https://doi.org/10.1002/rob.22480 <pub-id pub-id-type="doi">10.1002/rob.22480</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/rob.22480">https://doi.org/10.1002/rob.22480</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Alekseeva, N.M.</string-name>
              <string-name>Viller, A.G.</string-name>
              <string-name>Romanov, A.M.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>The Design of Endovascular Robots for Cardiac Interventions: A Survey</article-title>
            <source>Journal of Field Robotics</source>
            <volume>42</volume>
            <pub-id pub-id-type="doi">10.1002/rob.22480</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B4">
        <label>4.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Rogatinsky, J., Recco, D., Feichtmeier, J., Kang, Y., Kneier, N., Hammer, P., <italic>et al</italic>. (2023) A Multifunctional Soft Robot for Cardiac Interventions. <italic>Science</italic><italic>Advances</italic>, 9, adi5559. https://doi.org/10.1126/sciadv.adi5559 <pub-id pub-id-type="doi">10.1126/sciadv.adi5559</pub-id><pub-id pub-id-type="pmid">37878705</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1126/sciadv.adi5559">https://doi.org/10.1126/sciadv.adi5559</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Rogatinsky, J.</string-name>
              <string-name>Recco, D.</string-name>
              <string-name>Feichtmeier, J.</string-name>
              <string-name>Kang, Y.</string-name>
              <string-name>Kneier, N.</string-name>
              <string-name>Hammer, P.</string-name>
            </person-group>
            <year>2023</year>
            <article-title>A Multifunctional Soft Robot for Cardiac Interventions</article-title>
            <source>Science Advances</source>
            <volume>9</volume>
            <pub-id pub-id-type="doi">10.1126/sciadv.adi5559</pub-id>
            <pub-id pub-id-type="pmid">37878705</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B5">
        <label>5.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Elmaghraby, K.M., Gamal, A.A., Helmy, H.A.R. and Ghzally, Y. (2026) Angiographic and Early In-Hospital Profile of Primary Percutaneous Coronary Intervention in Patients with Substance Use Disorder Presenting with ST-Segment Elevation Myocardial Infarction. <italic>Scientific</italic><italic>Reports</italic>, 16, Article No. 25522. https://doi.org/10.1038/s41598-026-65981-9 <pub-id pub-id-type="doi">10.1038/s41598-026-65981-9</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1038/s41598-026-65981-9">https://doi.org/10.1038/s41598-026-65981-9</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Elmaghraby, K.M.</string-name>
              <string-name>Gamal, A.A.</string-name>
              <string-name>Helmy, H.A.R.</string-name>
              <string-name>Ghzally, Y.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>Angiographic and Early In-Hospital Profile of Primary Percutaneous Coronary Intervention in Patients with Substance Use Disorder Presenting with ST-Segment Elevation Myocardial Infarction</article-title>
            <source>Scientific Reports</source>
            <volume>16</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1038/s41598-026-65981-9</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B6">
        <label>6.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Li, R., Wang, J., Zhao, X., Liu, Z., Jia, P., Liu, Y., <italic>et al</italic>. (2025) Small-Scale Magnetic Soft Robotic Catheter for <italic>In</italic>- <italic>Situ</italic> Biomechanical Force Sensing. <italic>Biosensors</italic><italic>and</italic><italic>Bioelectronics</italic>, 270, Article ID: 116977. https://doi.org/10.1016/j.bios.2024.116977 <pub-id pub-id-type="doi">10.1016/j.bios.2024.116977</pub-id><pub-id pub-id-type="pmid">39586145</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.bios.2024.116977">https://doi.org/10.1016/j.bios.2024.116977</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Li, R.</string-name>
              <string-name>Wang, J.</string-name>
              <string-name>Zhao, X.</string-name>
              <string-name>Liu, Z.</string-name>
              <string-name>Jia, P.</string-name>
              <string-name>Liu, Y.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Small-Scale Magnetic Soft Robotic Catheter for In-Situ Biomechanical Force Sensing</article-title>
            <source>Biosensors and Bioelectronics</source>
            <volume>270</volume>
            <fpage>116977</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.bios.2024.116977</pub-id>
            <pub-id pub-id-type="pmid">39586145</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B7">
        <label>7.</label>
        <citation-alternatives>
          <mixed-citation publication-type="confproc">Cha, H., Yoon, H., Jung, K.Y., Yi, B., Lee, S. and Won, J.Y. (2016) A Robotic System for Percutaneous Coronary Intervention Equipped with a Steerable Catheter and Force Feedback Function. 2016 <italic>IEEE</italic>/ <italic>RSJ International Conference on Intelligent Robots and Systems</italic> ( <italic>IROS</italic>), Daejeon, 9-14 October 2016, 1151-1156. https://doi.org/10.1109/iros.2016.7759194 <pub-id pub-id-type="doi">10.1109/iros.2016.7759194</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/iros.2016.7759194">https://doi.org/10.1109/iros.2016.7759194</ext-link></mixed-citation>
          <element-citation publication-type="confproc">
            <person-group person-group-type="author">
              <string-name>Cha, H.</string-name>
              <string-name>Yoon, H.</string-name>
              <string-name>Jung, K.Y.</string-name>
              <string-name>Yi, B.</string-name>
              <string-name>Lee, S.</string-name>
              <string-name>Won, J.Y.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>A Robotic System for Percutaneous Coronary Intervention Equipped with a Steerable Catheter and Force Feedback Function</article-title>
            <source>2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)</source>
            <volume>9</volume>
            <pub-id pub-id-type="doi">10.1109/iros.2016.7759194</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B8">
        <label>8.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">George, J.C., Varghese, V. and Madder, R.D. (2025) Robot-Assisted Cardiovascular Interventions. <italic>Journal</italic><italic>of</italic><italic>the</italic><italic>Society</italic><italic>for</italic><italic>Cardiovascular</italic><italic>Angiography</italic><italic>&amp;</italic><italic>Interventions</italic>, 4, Article ID: 102568. https://doi.org/10.1016/j.jscai.2025.102568 <pub-id pub-id-type="doi">10.1016/j.jscai.2025.102568</pub-id><pub-id pub-id-type="pmid">40230678</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jscai.2025.102568">https://doi.org/10.1016/j.jscai.2025.102568</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>George, J.C.</string-name>
              <string-name>Varghese, V.</string-name>
              <string-name>Madder, R.D.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Robot-Assisted Cardiovascular Interventions</article-title>
            <source>Journal of the Society for Cardiovascular Angiography &amp; Interventions</source>
            <volume>4</volume>
            <fpage>102568</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jscai.2025.102568</pub-id>
            <pub-id pub-id-type="pmid">40230678</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B9">
        <label>9.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Durand, E., Sabatier, R., Smits, P.C., <italic>et al</italic>. (2022) Evaluation of the R-One Robotic System for Percutaneous Coronary Intervention: The R-EVOLUTION Study. <italic>EuroIntervention</italic>, 18, 621-628.</mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Durand, E.</string-name>
              <string-name>Sabatier, R.</string-name>
              <string-name>Smits, P.C.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Evaluation of the R-One Robotic System for Percutaneous Coronary Intervention: The R-EVOLUTION Study</article-title>
            <source>EuroIntervention</source>
            <volume>18</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B10">
        <label>10.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Liang, L., Xia, H., Duan, X., Liu, Y., Zhu, Z., Xiang, Y., <italic>et al</italic>. (2025) Effect of Operating Parameters of Vascular Robots with Different Thread Profiles on Arterial Hemodynamics. <italic>Journal</italic><italic>of</italic><italic>the</italic><italic>Brazilian</italic><italic>Society</italic><italic>of</italic><italic>Mechanical</italic><italic>Sciences</italic><italic>and</italic><italic>Engineering</italic>, 47, Article No. 582. https://doi.org/10.1007/s40430-025-05899-x <pub-id pub-id-type="doi">10.1007/s40430-025-05899-x</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s40430-025-05899-x">https://doi.org/10.1007/s40430-025-05899-x</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Liang, L.</string-name>
              <string-name>Xia, H.</string-name>
              <string-name>Duan, X.</string-name>
              <string-name>Liu, Y.</string-name>
              <string-name>Zhu, Z.</string-name>
              <string-name>Xiang, Y.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Effect of Operating Parameters of Vascular Robots with Different Thread Profiles on Arterial Hemodynamics</article-title>
            <source>Journal of the Brazilian Society of Mechanical Sciences and Engineering</source>
            <volume>47</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1007/s40430-025-05899-x</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B11">
        <label>11.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Xia, H., Zhu, Z., Yu, H., Zhou, J., Xiang, Y., Liang, L., <italic>et al</italic>. (2025) Effects of Vascular Stenosis on Hemodynamics during Vascular Robot Intervention Diagnosis and Treatment. <italic>Computer</italic><italic>Methods</italic><italic>in</italic><italic>Biomechanics</italic><italic>and</italic><italic>Biomedical</italic><italic>Engineering</italic>. https://doi.org/10.1080/10255842.2025.2568049 <pub-id pub-id-type="doi">10.1080/10255842.2025.2568049</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1080/10255842.2025.2568049">https://doi.org/10.1080/10255842.2025.2568049</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Xia, H.</string-name>
              <string-name>Zhu, Z.</string-name>
              <string-name>Yu, H.</string-name>
              <string-name>Zhou, J.</string-name>
              <string-name>Xiang, Y.</string-name>
              <string-name>Liang, L.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Effects of Vascular Stenosis on Hemodynamics during Vascular Robot Intervention Diagnosis and Treatment</article-title>
            <pub-id pub-id-type="doi">10.1080/10255842.2025.2568049</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B12">
        <label>12.</label>
        <citation-alternatives>
          <mixed-citation publication-type="report">Xu, K., Cao, X., Liu, H., Zhou, S., Liu, Z., Wang, X., <italic>et al</italic>. (2024) Long-Distance Tele-Robotic-Assisted Percutaneous Coronary Intervention: A Case Report of First-in-Patient in China. <italic>Cardiology</italic><italic>Discovery</italic>, 4, 245-249. https://doi.org/10.1097/cd9.0000000000000131 <pub-id pub-id-type="doi">10.1097/cd9.0000000000000131</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1097/cd9.0000000000000131">https://doi.org/10.1097/cd9.0000000000000131</ext-link></mixed-citation>
          <element-citation publication-type="report">
            <person-group person-group-type="author">
              <string-name>Xu, K.</string-name>
              <string-name>Cao, X.</string-name>
              <string-name>Liu, H.</string-name>
              <string-name>Zhou, S.</string-name>
              <string-name>Liu, Z.</string-name>
              <string-name>Wang, X.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Long-Distance Tele-Robotic-Assisted Percutaneous Coronary Intervention: A Case Report of First-in-Patient in China</article-title>
            <source>Cardiology Discovery</source>
            <volume>4</volume>
            <pub-id pub-id-type="doi">10.1097/cd9.0000000000000131</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B13">
        <label>13.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Chen, P., Wang, Y. and Tian, D. (2025) Design and Evaluation of a Leader-Follower Isomorphic Vascular Interventional Surgical Robot. <italic>Actuators</italic>, 14, Article No. 29. https://doi.org/10.3390/act14010029 <pub-id pub-id-type="doi">10.3390/act14010029</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/act14010029">https://doi.org/10.3390/act14010029</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Chen, P.</string-name>
              <string-name>Wang, Y.</string-name>
              <string-name>Tian, D.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Design and Evaluation of a Leader-Follower Isomorphic Vascular Interventional Surgical Robot</article-title>
            <source>Actuators</source>
            <volume>14</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.3390/act14010029</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B14">
        <label>14.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Guo, M., Li, B., Gao, Y. and Chen, Y. (2026) Alfvénic Motions in a Stratified Open Flux Tube: Transition from Propagating to Locally Standing Motions and Implications for the Kelvin-Helmholtz Instability. <italic>The</italic><italic>Astrophysical</italic><italic>Journal</italic><italic>Letters</italic>, 1007, L44. https://doi.org/10.3847/2041-8213/ae9474 <pub-id pub-id-type="doi">10.3847/2041-8213/ae9474</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3847/2041-8213/ae9474">https://doi.org/10.3847/2041-8213/ae9474</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Guo, M.</string-name>
              <string-name>Li, B.</string-name>
              <string-name>Gao, Y.</string-name>
              <string-name>Chen, Y.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>Alfvénic Motions in a Stratified Open Flux Tube: Transition from Propagating to Locally Standing Motions and Implications for the Kelvin-Helmholtz Instability</article-title>
            <source>The Astrophysical Journal Letters</source>
            <volume>1007</volume>
            <pub-id pub-id-type="doi">10.3847/2041-8213/ae9474</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B15">
        <label>15.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Li, Z. and Yang, B. (2026) Premature Oil Generation and Immature Oil Overestimation from Extrapolation of Gold Tube Pyrolysis Kinetics: From Experimental Artifacts to Model Distortions. <italic>Organic</italic><italic>Geochemistry</italic>, 221, Article ID: 105277. https://doi.org/10.1016/j.orggeochem.2026.105277 <pub-id pub-id-type="doi">10.1016/j.orggeochem.2026.105277</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.orggeochem.2026.105277">https://doi.org/10.1016/j.orggeochem.2026.105277</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Li, Z.</string-name>
              <string-name>Yang, B.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>Premature Oil Generation and Immature Oil Overestimation from Extrapolation of Gold Tube Pyrolysis Kinetics: From Experimental Artifacts to Model Distortions</article-title>
            <source>Organic Geochemistry</source>
            <volume>221</volume>
            <fpage>105277</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.orggeochem.2026.105277</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B16">
        <label>16.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Buono, R., Castriconi, R., Tudda, A., Gigliotti, C., Perna, L., Mangili, P., <italic>et al</italic>. (2026) Development and Validation of a Knowledge-Based Model for Robotic Radiosurgery Planning for Brain Lesions. <italic>Physics</italic><italic>and</italic><italic>Imaging</italic><italic>in</italic><italic>Radiation</italic><italic>Oncology</italic>, 39, Article ID: 101020. https://doi.org/10.1016/j.phro.2026.101020 <pub-id pub-id-type="doi">10.1016/j.phro.2026.101020</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.phro.2026.101020">https://doi.org/10.1016/j.phro.2026.101020</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Buono, R.</string-name>
              <string-name>Castriconi, R.</string-name>
              <string-name>Tudda, A.</string-name>
              <string-name>Gigliotti, C.</string-name>
              <string-name>Perna, L.</string-name>
              <string-name>Mangili, P.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>Development and Validation of a Knowledge-Based Model for Robotic Radiosurgery Planning for Brain Lesions</article-title>
            <source>Physics and Imaging in Radiation Oncology</source>
            <volume>39</volume>
            <fpage>101020</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.phro.2026.101020</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B17">
        <label>17.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Yu, Y., Chen, Z., Wang, Z., Li, Y., Yang, L., Qi, J., <italic>et al</italic>. (2025) Robot-Assisted Percutaneous Coronary Intervention: A Prospective, Multicenter, Randomized Controlled, Non-Inferiority Clinical Trial. <italic>Journal</italic><italic>of</italic><italic>Geriatric</italic><italic>Cardiology</italic>, 22, 725-735. https://doi.org/10.26599/1671-5411.2025.08.008 <pub-id pub-id-type="doi">10.26599/1671-5411.2025.08.008</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.26599/1671-5411.2025.08.008">https://doi.org/10.26599/1671-5411.2025.08.008</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Yu, Y.</string-name>
              <string-name>Chen, Z.</string-name>
              <string-name>Wang, Z.</string-name>
              <string-name>Li, Y.</string-name>
              <string-name>Yang, L.</string-name>
              <string-name>Qi, J.</string-name>
              <string-name>Prospective, M</string-name>
              <string-name>Controlled, N</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Robot-Assisted Percutaneous Coronary Intervention: A Prospective, Multicenter, Randomized Controlled, Non-Inferiority Clinical Trial</article-title>
            <source>Journal of Geriatric Cardiology</source>
            <volume>22</volume>
            <pub-id pub-id-type="doi">10.26599/1671-5411.2025.08.008</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B18">
        <label>18.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Zhang, Y., Liu, X. and Dong, Y. (2022) Ordering Problem of Vascular Robot Based on Time Series Prediction. <italic>Journal of Artificial Intelligence Practice</italic>, 5, 8-14.</mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Zhang, Y.</string-name>
              <string-name>Liu, X.</string-name>
              <string-name>Dong, Y.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Ordering Problem of Vascular Robot Based on Time Series Prediction</article-title>
            <source>Journal of Artificial Intelligence Practice</source>
            <volume>5</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B19">
        <label>19.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Houri, J.M., Berger, T., Gaza, R., Hussein, H., Schwarz, S., Waterman, G., <italic>et al</italic>. (2026) First Evaluation of Wearable Radiation Protection for Human Deep Space Exploration, as Flown on Artemis I. <italic>Science</italic><italic>Advances</italic>, 12, eadz1892. https://doi.org/10.1126/sciadv.adz1892 <pub-id pub-id-type="doi">10.1126/sciadv.adz1892</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1126/sciadv.adz1892">https://doi.org/10.1126/sciadv.adz1892</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Houri, J.M.</string-name>
              <string-name>Berger, T.</string-name>
              <string-name>Gaza, R.</string-name>
              <string-name>Hussein, H.</string-name>
              <string-name>Schwarz, S.</string-name>
              <string-name>Waterman, G.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>First Evaluation of Wearable Radiation Protection for Human Deep Space Exploration, as Flown on Artemis I</article-title>
            <source>Science Advances</source>
            <volume>12</volume>
            <pub-id pub-id-type="doi">10.1126/sciadv.adz1892</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B20">
        <label>20.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Mak, W.R., Zhang, Y., Chen, J., Ng, J.P., Wong, C., Lam, G.Y., <italic>et al</italic>. (2026) Surgical Accuracy of Open Platform Image-Based Robotic-Assisted Total Hip Arthroplasty. <italic>Arthroplasty</italic>, 8, Article No. 10. https://doi.org/10.1186/s42836-026-00370-1 <pub-id pub-id-type="doi">10.1186/s42836-026-00370-1</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s42836-026-00370-1">https://doi.org/10.1186/s42836-026-00370-1</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Mak, W.R.</string-name>
              <string-name>Zhang, Y.</string-name>
              <string-name>Chen, J.</string-name>
              <string-name>Ng, J.P.</string-name>
              <string-name>Wong, C.</string-name>
              <string-name>Lam, G.Y.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>Surgical Accuracy of Open Platform Image-Based Robotic-Assisted Total Hip Arthroplasty</article-title>
            <source>Arthroplasty</source>
            <volume>8</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1186/s42836-026-00370-1</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B21">
        <label>21.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Ren, B., Li, H., Cao, Y., Wang, C., Zhao, Y. and Zhang, J. (2026) A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors. <italic>Biomimetics</italic>, 11, Article No. 229. https://doi.org/10.3390/biomimetics11040229 <pub-id pub-id-type="doi">10.3390/biomimetics11040229</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/biomimetics11040229">https://doi.org/10.3390/biomimetics11040229</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Ren, B.</string-name>
              <string-name>Li, H.</string-name>
              <string-name>Cao, Y.</string-name>
              <string-name>Wang, C.</string-name>
              <string-name>Zhao, Y.</string-name>
              <string-name>Zhang, J.</string-name>
            </person-group>
            <year>2026</year>
            <article-title>A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors</article-title>
            <source>Biomimetics</source>
            <volume>11</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.3390/biomimetics11040229</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
    </ref-list>
  </back>
</article>