<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN" "JATS-journalpublishing1-4.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.4" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">ojce</journal-id>
      <journal-title-group>
        <journal-title>Open Journal of Civil Engineering</journal-title>
      </journal-title-group>
      <issn pub-type="epub">2164-3172</issn>
      <issn pub-type="ppub">2164-3164</issn>
      <publisher>
        <publisher-name>Scientific Research Publishing</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.4236/ojce.2026.163020</article-id>
      <article-id pub-id-type="publisher-id">ojce-152595</article-id>
      <article-categories>
        <subj-group>
          <subject>Article</subject>
        </subj-group>
        <subj-group>
          <subject>Engineering</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Recent Advances in the Mechanical and Thermal Performance of Concrete Sandwich Panels</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <contrib-id contrib-id-type="orcid">0009-0005-3819-0983</contrib-id>
          <name name-style="western">
            <surname>Ali</surname>
            <given-names>Abdelrahman</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Magunda</surname>
            <given-names>Taropafadzwa</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Dikgang</surname>
            <given-names>Olebole</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="aff1"><label>1</label> College of Civil and Transportation Engineering, Hohai University, Nanjing, China </aff>
      <author-notes>
        <fn fn-type="conflict" id="fn-conflict">
          <p>The authors declare no conflicts of interest regarding the publication of this paper.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub">
        <day>01</day>
        <month>09</month>
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="collection">
        <month>09</month>
        <year>2026</year>
      </pub-date>
      <volume>16</volume>
      <issue>03</issue>
      <fpage>383</fpage>
      <lpage>412</lpage>
      <history>
        <date date-type="received">
          <day>05</day>
          <month>06</month>
          <year>2026</year>
        </date>
        <date date-type="accepted">
          <day>14</day>
          <month>07</month>
          <year>2026</year>
        </date>
        <date date-type="published">
          <day>17</day>
          <month>07</month>
          <year>2026</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2026 by the authors and Scientific Research Publishing Inc.</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="open-access">
          <license-p> This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link> ). </license-p>
        </license>
      </permissions>
      <self-uri content-type="doi" xlink:href="https://doi.org/10.4236/ojce.2026.163020">https://doi.org/10.4236/ojce.2026.163020</self-uri>
      <abstract>
        <p>Concrete sandwich panels (CSPs) are increasingly used in energy-efficient building envelopes due to their ability to combine structural load-bearing capacity with thermal insulation. This review provides an integrated assessment of recent advances (2018-2025) in the thermal and mechanical performance of CSPs, with particular emphasis on the trade-off between structural efficiency and thermal performance. The literature indicates a transition from traditional steel connectors, which induce significant thermal bridging, to low-conductivity fiber-reinforced polymer (FRP) connectors and optimized geometrical configurations. These developments, together with advanced insulation materials, have improved overall panel efficiency. However, mechanical performance remains strongly dependent on the degree of composite action, governed by connector stiffness, spacing, and configuration. A key finding of this review is the persistent conflict between mechanical and thermal requirements, where increased structural stiffness may lead to higher thermal-induced stresses and deformation. In addition, current research largely treats thermal and mechanical behaviors separately, with limited consideration of fully coupled thermo-mechanical interactions. Durability aspects, including moisture ingress, freeze-thaw effects, and long-term connector performance, are also insufficiently addressed. This review synthesizes current knowledge, highlights inconsistencies in experimental and modeling approaches, and identifies critical research gaps. Future studies should focus on integrated multi-physics modeling and full-scale experimental validation to improve the long-term performance and reliability of CSP systems.</p>
      </abstract>
      <kwd-group kwd-group-type="author-generated" xml:lang="en">
        <kwd>Concrete Sandwich Panels</kwd>
        <kwd>Mechanical Performance</kwd>
        <kwd>Thermal Performance</kwd>
        <kwd>Shear Connectors</kwd>
        <kwd>Composite Action</kwd>
        <kwd>Thermal Insulation</kwd>
        <kwd>Durability</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>1. Introduction</title>
      <p>Concrete sandwich panels (CSPs) have become a widely adopted structural and thermal solution for modern building envelopes due to their light weight, high stiffness-to-weight ratio, and inherent thermal insulation capability. A typical CSP consists of two concrete wythes (outer layers) separated by an insulation core, with shear connectors embedded to transfer forces between the wythes and enable composite structural action. The growing global demand for energy-efficient and sustainable construction has driven substantial research over the past decade to optimize CSP performance specifically, to improve insulation systems, refine connector design, and understand the interaction between thermal and structural behaviors under realistic service conditions.</p>
      <p>The performance of CSPs is governed by a complex interplay among connector material, geometry, spacing, insulation type, and the resulting degree of composite action (DCA) [<xref ref-type="bibr" rid="B1">1</xref>]-[<xref ref-type="bibr" rid="B4">4</xref>]. Thermally, the primary concern is thermal bridging localized heat flow paths through conductive elements which has traditionally been caused by metallic connectors. This has motivated the development of low-conductivity fiber-reinforced polymer (FRP) connectors and advanced insulation materials such as vacuum insulation panels (VIPs) and phase-change material (PCM) composites [<xref ref-type="bibr" rid="B5">5</xref>]-[<xref ref-type="bibr" rid="B9">9</xref>]. Mechanically, the flexural and shear behavior of panels, the role of connector stiffness in achieving composite action, and the critical failure mechanisms that govern panel capacity have received increasing attention.</p>
      <p>However, a fundamental trade-off has become evident: stiffer connectors that improve structural performance also exacerbate thermal bowing and increase connector stresses under thermal gradients. This conflict between thermal efficiency and mechanical strength is a recurring theme in the literature [<xref ref-type="bibr" rid="B10">10</xref>]-[<xref ref-type="bibr" rid="B12">12</xref>]. Despite its importance, very few studies have addressed the coupled thermo-mechanical behavior of CSPs, even though real buildings are simultaneously exposed to thermal gradients, mechanical loads, moisture transport, and environmental aging. Most existing works rely on simplified or sequentially coupled numerical models that ignore temperature-dependent properties, moisture effects, and the feedback between thermal and mechanical damage. Consequently, significant knowledge gaps remain regarding panel performance under fire conditions, long-term loading, environmental exposure, and dynamic climatic variations.</p>
      <p><xref ref-type="fig" rid="fig1">Figure 1</xref>: is a schematic representation of the thermal-bridge effect in concrete sandwich panels. A CSP consists of two outers concrete wythes and an internal insulation layer that is meant to impede heat transfer. Under a thermal gradient, there is some heat flow through the insulation core by uniform, low-intensity paths. With the addition of a steel shear connector, however, there is now a highly conductive path between the wythes. This connector serves as a thermal short-circuit, drawing heat through the panel and creating a localized spike in heat flux. This is evidenced by the clustered, thick heat-flow arrows concentrated around the connector. The figure provides a reason why steel connectors greatly increase U-values, create cold zones on internal surfaces, and reduce the energy efficiency of CSPs-motivating the transition to FRP connectors and optimized connector layouts in modern design.</p>
      <fig id="fig1">
        <label>Figure 1</label>
        <graphic xlink:href="https://html.scirp.org/file/1882187-rId17.jpeg?20260717104941" />
      </fig>
      <p><bold>Figure 1.</bold> Thermal bridge effect in concrete sandwich panels.</p>
      <sec id="sec1dot1">
        <title>1.1. Novelty and Contribution of This Review</title>
        <p>While most past review papers examine the thermal and mechanical performances of CSPs separately, this paper offers an overview of both the interactions between them. Through a comparison among various types of cores, connectors, and designs, this paper reveals the intrinsic conflicts between the structural and thermal performances of CSPs. Furthermore, through this comprehensive review, several shortcomings have been found in past research efforts, especially the lack of attention to the thermo-mechanical coupling phenomenon, as well as some issues related to the durability, such as water infiltration and freezing-thawing cycles, connector durability, and so on. Finally, this paper summarizes various studies done within the period between 2018 and 2025 to quantify the ranges of mechanical and thermal performances of CSPs and analyze the potential discrepancies among different experimental setups.</p>
        <p>Several studies conducted in recent years have attempted to highlight some of the important performance aspects of CSPs. Tawil <italic>et al</italic>. [<xref ref-type="bibr" rid="B13">13</xref>] have given a detailed discussion regarding the mechanical and thermal properties of PCSPs but have mainly discussed material properties without considering the balance between structural performance and thermal performance. In contrast, Sah <italic>et al</italic>. [<xref ref-type="bibr" rid="B14">14</xref>] have presented a review study on prefabricated concrete sandwich panels in terms of their use as lightweight wall panels but have discussed structural performance without discussing thermal performance in detail. Recently, Pozo-Lora <italic>et al</italic>. [<xref ref-type="bibr" rid="B15">15</xref>] have presented a review study on the construction technology of CSWPs where material aspects and construction technologies of CSWPs have been discussed. This review paper differs from the above-discussed studies because it attempts to evaluate: 1) providing an integrated, side‑by‑side assessment of both thermal and mechanical performance criteria using studies published between 2018 and 2025, 2) explicitly analyzing the trade‑off between structural integrity and thermal insulation as a recurring theme across experimental and numerical studies, 3) critically evaluating the limitations of decoupled thermal and mechanical analyses, and 4) identifying the absence of validated, fully coupled thermo‑mechanical models as a primary research gap. To the best of our knowledge, no previous review has systematically compared thermal and mechanical findings from the period 2018‑2025 to highlight the inherent conflicts and coupled effects that govern real‑world CSP behavior.</p>
      </sec>
      <sec id="sec1dot2">
        <title>1.2. Scope and Structure of the Paper</title>
        <p>Following the literature search methodology described in Section 1.3, this review is structured to provide a systematic and integrated analysis of the thermal and mechanical performance of concrete sandwich panels (CSPs). Section 2 examines the thermal performance of CSPs, with emphasis on the influence of connector materials and geometries, insulation systems, and the quantification of thermal bridging effects. It also reviews relevant numerical modeling approaches and discusses variations in reported thermal properties across different studies. Section 3 focuses on mechanical performance, including the role of connector types, degree of composite action, failure mechanisms, and the contribution of insulation cores to structural behavior. Particular attention is given to discrepancies in experimental findings and their underlying causes. Section 4 presents a critical review of thermo-mechanical coupling studies, distinguishing between fully coupled and sequential modeling approaches. Key phenomena such as thermal bowing and connector-induced stresses under temperature gradients are analyzed to highlight current modeling limitations. Finally, Section 5 provides concluding remarks and outlines recommendations for future research directions aimed at improving the performance and reliability of CSP systems.</p>
        <p>When this review relies upon studies which do not create complete concrete sandwich panel structures (for instance, when looking at the study of new insulating materials, connector degradation in alkaline conditions, or the behavior of similar composite materials during a fire), such studies will be referred to solely as examples in relation to a particular mechanism.</p>
      </sec>
      <sec id="sec1dot3">
        <title>1.3. Literature Search Methodology</title>
        <p>A systematic literature search was conducted in November 2025 to identify relevant studies published between January 2018 and December 2025. The primary search was performed on the Web of Science Core Collection. Google Scholar was subsequently used to locate and download full texts but was not used as a separate source for record counting.</p>
        <p>The search string was constructed using Boolean operators to combine keywords related to panel type, materials, performance metrics, and analysis methods:</p>
        <p>((“sandwich” OR “multilayer”) AND concrete AND (panel* OR wall* OR slab*) AND (“mechanical” OR “flexural” OR “shear” OR “compression”) AND (“thermal” OR “insulation” OR “conductivity” OR “energy performance”) AND (connector* OR “interlayer” OR bond OR core OR foam) AND (“finite element” OR numerical OR simulation OR experimental))</p>
        <p>The initial search returned 154 records from Web of Science. After removing 8 duplicate records (using reference management software), 146 unique records remained.</p>
        <p>These 146 records were screened in two stages:</p>
        <p>1) Title and abstract screening: Records were included if they reported experimental, numerical, or analytical investigations focused on the mechanical or thermal performance of concrete sandwich panels incorporating shear connectors. Records were excluded if they a) used non‑concrete materials (e.g., pure steel or wood sandwich panels), b) lacked quantitative data, or c) addressed acoustic‑only behavior. This stage excluded 90 records, leaving 56 records for full‑text review.</p>
        <p>2) Full‑text screening: The full texts of the remaining 56 records were assessed against the same inclusion criteria, with the additional requirement that studies must report quantifiable outcomes (e.g., load‑deflection behavior, stiffness, U‑value, connector forces, or degree of composite action). A further 11 records were excluded because the full text could not be obtained or was not available.</p>
        <p>This systematic process yielded a final set of 45 primary studies that form the foundation of this review.</p>
        <p>In a small number of cases, studies that did not construct or test full concrete sandwich panels were included as supporting analogies. Specifically, studies investigating novel insulation materials (e.g., phase‑change materials, bio‑based foams), connector ageing in alkaline environments, or fire behavior of related composite panels were retained only when their findings directly informed the interpretation of CSP thermal or mechanical performance. These studies are explicitly identified in the text as supporting evidence rather than primary CSP data.</p>
      </sec>
    </sec>
    <sec id="sec2">
      <title>2. Thermal Performance and Heat Transfer Analysis</title>
      <p>The thermal efficiency of Precast Concrete Sandwich Panels (PCSPs) is governed by the insulation core and the thermal bridging introduced by shear connectors. While the fundamental trade-off between mechanical connectivity and thermal resistance is well-recognized, a critical examination of the literature reveals significant methodological inconsistencies, contradictory findings, and knowledge gaps that this review aims to synthesize.</p>
      <sec id="sec2dot1">
        <title>2.1. The Paramountcy of Connector Material and Design</title>
        <p>Basically, the material selection of shear connectors can be considered the most influential factor for thermal bridging mitigation. There is a significant difference between conventional steel and new FRP shear connectors. Conventional steel connectors have high thermal conductivities (e.g., 16 - 60 W/m·K) that imply a substantial thermal bridge, causing high U-values and point heat loss [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B11">11</xref>]. For example, the replacement of carbon steel (58.2 W/m·K) with stainless steel (16.2 W/m·K) shear connectors reduced the thermal transmittance by 24.5% [<xref ref-type="bibr" rid="B7">7</xref>]. However, an uncritical acceptance of FRP superiority obscures important nuances. Steel connectors, despite their high conductivity, remain viable when geometric optimization is employed. Bida <italic>et al</italic>. [<xref ref-type="bibr" rid="B16">16</xref>] demonstrated that staggering steel plate connectors at 400 mm spacing corresponding to a 127% increase in R-value and a 56.5% reduction in U-value, achieving thermal performance comparable to some FRP designs. This finding directly challenges the implicit assumption that FRP is always necessary for high thermal efficiency. Conversely, Yu <italic>et al</italic>. [<xref ref-type="bibr" rid="B17">17</xref>] showed that even with FRP connectors, improper spacing (≤200 mm) can negate their low-conductivity advantage, producing U-values (0.65 W/m<sup>2</sup>·K) that are worse than optimally staggered steel designs [<xref ref-type="bibr" rid="B16">16</xref>].</p>
        <p>In contrast, FRP connectors (e.g., GFRP, BFRP, CFRP), with their inherently low thermal conductivity (typically 0.125 - 1.37 W/m·K), dramatically diminish this effect. Numerical and experimental studies consistently report GFRP connectors result in “minimal” or “negligible” thermal bridging [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B18">18</xref>]. Their use is a main theme in the literature, often cited as the primary strategy to avoid the thermal performance penalties associated with steel [<xref ref-type="bibr" rid="B4">4</xref>][<xref ref-type="bibr" rid="B5">5</xref>][<xref ref-type="bibr" rid="B19">19</xref>]-[<xref ref-type="bibr" rid="B23">23</xref>]. A critical methodological issue emerges when comparing studies: most investigations report steady-state U-values under idealized laboratory conditions, which fail to capture diurnal cycling or solar radiation effects. Only four studies in this review employed transient or dynamic boundary conditions [<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B12">12</xref>][<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B24">24</xref>], and none directly compared steady-state versus transient performance for identical panel configurations. This gap raises questions about the real-world applicability of reported U-value rankings.</p>
        <p>Beyond material, the geometric configuration of connectors is equally important. Research has shown that with increased connector spacing [<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B25">25</xref>] and through the use of a staggered layout, dramatic improvements in thermal resistance can be achieved. Staggering connectors increases the length and tortuosity of the heat flow path, and one study has reported a 127% improvement in R-value resulting from switching from a direct to a 400 mm staggered layout [<xref ref-type="bibr" rid="B16">16</xref>]. Similarly, reducing the cross-sectional area and embedded length of a connector also produces positive thermal benefits [<xref ref-type="bibr" rid="B17">17</xref>]. Furthermore, the thermal performance of hybrid connectors such as steel elements with thermal breaks [<xref ref-type="bibr" rid="B26">26</xref>][<xref ref-type="bibr" rid="B27">27</xref>] remains qualitatively claimed but quantitatively unvalidated. No study to date has experimentally measured the thermal bridge reduction of such novel designs, representing a critical research gap.</p>
        <p><xref ref-type="fig" rid="fig2">Figure 2</xref>. Thermal conductivity comparison of common PCSP materials. The logarithmic scale highlights the orders of magnitude difference between conductive steel connectors and insulating FRP alternatives. Carbon steel exhibits the highest conductivity (58.2 W/m·K), while VIP insulation shows the lowest (0.005 W/m·K). FRP connectors (GFRP: 0.35 W/m·K, CFRP: 8.0 W/m·K) demonstrate significantly reduced thermal bridging potential compared to metallic options, making them preferable for energy-efficient designs [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B6">6</xref>][<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B11">11</xref>][<xref ref-type="bibr" rid="B17">17</xref>].</p>
        <fig id="fig2">
          <label>Figure 2</label>
          <graphic xlink:href="https://html.scirp.org/file/1882187-rId18.jpeg?20260717104943" />
        </fig>
        <p><bold>Figure 2.</bold> Thermal conductivity of PCSP materials.</p>
      </sec>
      <sec id="sec2dot2">
        <title>2.2. Insulation Systems: Core Materials and Advanced Solutions</title>
        <p>The main resistance to heat flow is provided by the insulation core, whose properties are fundamental to the U-value of the panel. By a wide margin, insulation thickness is found to be the most important parameter that can be used to improve thermal performance. One study increased the thickness of XPS insulation from 30 mm to 90 mm and recorded a U-value reduction of approximately 59% [<xref ref-type="bibr" rid="B17">17</xref>], while other researchers have similarly found better performances with 40-50 mm thick solutions compared to thinner ones [<xref ref-type="bibr" rid="B28">28</xref>]. However, the marginal benefit diminishes beyond 100 mm; Li <italic>et al</italic>. [<xref ref-type="bibr" rid="B7">7</xref>] reported only a 5% additional reduction in U-value when increasing thickness from 100 mm to 150 mm, suggesting an economic optimum around 80 - 100 mm for most climates.</p>
        <p>Performance is also affected by insulation type (XPS, EPS, PU, Mineral Wool), although usually to a lesser degree than thickness. Whereas XPS and PU usually have lower conductivity than EPS [<xref ref-type="bibr" rid="B29">29</xref>], several authors have reported that the difference between XPS and EPS has a “negligible influence” on the final inner surface temperature [<xref ref-type="bibr" rid="B28">28</xref>]. This apparent contradiction likely arises from differing boundary conditions. Yu <italic>et al</italic>. [<xref ref-type="bibr" rid="B17">17</xref>] applied a 50˚C temperature differential (40˚C to −10˚C), while Thangarasu and Helena [<xref ref-type="bibr" rid="B28">28</xref>] used a milder 47˚C - 53˚C differential (75˚C outer to 22˚C - 28˚C inner). Under larger thermal gradients, conductivity differences become amplified, explaining the conflicting conclusions.</p>
        <p>This level of performance has driven interest in advanced insulation materials. Examples include Vacuum Insulation Panels (VIPs) that can provide very low conductivity, around 0.005 W/m·K, enabling extremely low U-values such as 0.096 W/m<sup>2</sup>·K [<xref ref-type="bibr" rid="B6">6</xref>]. However, O’Hegarty <italic>et al</italic>. [<xref ref-type="bibr" rid="B6">6</xref>] critically documented that concrete seepage bridges as thin as 1 - 4 mm increases the U-value by a factor of 1.9 to 3.0, and gaps between VIP modules due to non-standard panel dimensions can reduce effective thermal resistance by over 40%. These practical limitations, often overlooked in laboratory studies, severely constrain VIP adoption in real-world prefabrication. Other recent developments include geopolymer concrete composites with Phase Change Material (PCM) capsules: up to 47% U-value reduction was achieved through latent heat storage [<xref ref-type="bibr" rid="B26">26</xref>], though long-term cycling stability of PCMs in alkaline environments remains unverified.</p>
      </sec>
      <sec id="sec2dot3">
        <title>2.3. Quantification and Mitigation of Thermal Bridges</title>
        <p>Thermal bridging is a quantifiable phenomenon, not just a conceptual drawback. FEA studies graphically depict concentrated heat flux paths through conductive connectors [<xref ref-type="bibr" rid="B19">19</xref>][<xref ref-type="bibr" rid="B21">21</xref>] and resultant localized surface temperature depressions, or “islands” [<xref ref-type="bibr" rid="B29">29</xref>]. The extent of the effect has been quantified as a “thermal bridge influence region” extending 80 - 130 mm from a stainless-steel connector [<xref ref-type="bibr" rid="B17">17</xref>]. For FRP connectors, the influence region was deemed “too small to define” using the same methodology, but this does not imply zero thermal bridging; rather, it highlights a measurement limitation.</p>
        <p>A concerning finding is that validation errors between FEA and experiments vary substantially, from as low as 2.3% [<xref ref-type="bibr" rid="B16">16</xref>] to as high as 16% [<xref ref-type="bibr" rid="B2">2</xref>]. Jawdhari and Fam [<xref ref-type="bibr" rid="B2">2</xref>] reported a 16% error for thermal bowing predictions under extreme cold (−50˚C), suggesting that material property assumptions specifically, using constant conductivity versus temperature-dependent values become critical at temperature extremes. Similarly, Li <italic>et al</italic>. [<xref ref-type="bibr" rid="B7">7</xref>] attributed their 11.8% average error to neglecting air gaps between layers, a simplifying assumption common to most FEA models. No study has systematically quantified the error introduced by these assumptions, leaving readers uncertain about the reliability of reported U-values.</p>
        <p>Effective mitigation strategies go beyond the choice of FRP connectors. A particularly successful strategy involves providing a thermal break layer on the inner wythe. A layer of AAC used in place of conventional concrete was found to significantly flatten the temperature distribution around connectors, rendering the wall a 12.5% reduction in thermal bridge influence (<italic>i.e.</italic>, lower sensitivity to connector-induced heat loss) and achieving a 47% lower U-value compared with the conventional panel [<xref ref-type="bibr" rid="B7">7</xref>]. Further, the presence of thermal bridges at the macro-scale, such as panel-to-panel joints, and the interfaces of panels with other building elements, introduces significant heat losses, highlighting the need for optimization to minimize linear thermal transmittance (ψ-value) [<xref ref-type="bibr" rid="B24">24</xref>]. Yang <italic>et al</italic>. [<xref ref-type="bibr" rid="B24">24</xref>] demonstrated that making adjacent walls thermally similar reduced the ψ-value of vertical joints by 28.9%, yet no study has validated these optimizations under full-scale structural loading.</p>
        <p><xref ref-type="fig" rid="fig3">Figure 3</xref>. Thermal bridge visualization and mitigation strategies. (a) Temperature distribution showing localized cold spots at steel connector locations; (b) Heat flux concentration demonstrating preferential heat flow paths through thermal bridges; (c) Comparative effectiveness of mitigation strategies, with AAC thermal break layers providing the most significant U-value reduction (74% improvement over baseline steel connectors) [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B25">25</xref>].</p>
        <fig id="fig3">
          <label>Figure 3</label>
          <graphic xlink:href="https://html.scirp.org/file/1882187-rId19.jpeg?20260717104943" />
        </fig>
        <p><bold>Figure 3.</bold> Thermal bridge visualization and mitigation strategies.</p>
      </sec>
      <sec id="sec2dot4">
        <title>2.4. Numerical Modeling and Experimental Validation</title>
        <p>Numerical modeling, with particular emphasis on 3D FEA, is an important predictor of the complex thermal behavior of PCSPs. Sophisticated models using ANSYS, ABAQUS, and COMSOL have been successfully used to simulate steady-state and transient heat transfer [<xref ref-type="bibr" rid="B2">2</xref>], temperature-dependent material properties [<xref ref-type="bibr" rid="B3">3</xref>], and intricate connector geometries [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B17">17</xref>].</p>
        <p>The validity of such models is very strong, with various studies consistently showing very close agreement with experimental results. The error in the predicted versus the experimentally measured U-value or surface temperatures is often less than 10% [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B16">16</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B29">29</xref>], going as low as 2.5%-5.8% for some cases [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B17">17</xref>]. Experimental validations have mainly been done by means of the standard guarded hot box test [<xref ref-type="bibr" rid="B7">7</xref>][<xref ref-type="bibr" rid="B16">16</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B29">29</xref>] and transient thermal enclosure tests [<xref ref-type="bibr" rid="B12">12</xref>].</p>
        <p>Yet, all these models have their limitations. The most commonly used simplifying assumptions include steady-state conditions [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B28">28</xref>], constant material properties [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B2">2</xref>], perfect interfacial bonds, and neglecting moisture effects and internal air convection [<xref ref-type="bibr" rid="B3">3</xref>][<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B26">26</xref>]. The steady-state assumption, used in twelve of the fourteen modeling studies reviewed, ignores thermal mass effects. Concrete wythes have significant heat capacity (approximately 1000 J/kg·K), which attenuates diurnal temperature swings. Transient analyses [<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B12">12</xref>] show that steady-state models overestimate heat flow by 15% - 25% under cyclic loading, yet no design guidelines currently incorporate this correction. Constant material properties fail to capture conductivity changes with temperature; for XPS, conductivity increases by 30% - 40% from 0˚C to 50˚C [<xref ref-type="bibr" rid="B3">3</xref>], while for concrete, moisture‑dependent conductivity can vary by ±20% [<xref ref-type="bibr" rid="B26">26</xref>]. Fire exposure studies [<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B19">19</xref>] explicitly show that property degradation dramatically alters heat transfer, but ambient‑temperature studies universally ignore this a potentially serious limitation for panels installed in extreme climates. Perfect bond assumptions neglect contact resistance, which can reduce thermal bridging by 5% - 10% due to microscopic air gaps [<xref ref-type="bibr" rid="B17">17</xref>]. These simplifications can lead to discrepancies in real-world scenarios, especially during fire exposure [<xref ref-type="bibr" rid="B18">18</xref>] or dynamic environmental loading.</p>
      </sec>
      <sec id="sec2dot5">
        <title>2.5. Critical Analysis and Future Research Directions</title>
        <p>While the literature establishes the superiority of FRP connectors and the importance of insulation thickness, several gaps are evident. A key limitation is that many studies promote the thermal benefits of FRPs only qualitatively, without quantitative system-level data for assembled panels [<xref ref-type="bibr" rid="B16">16</xref>][<xref ref-type="bibr" rid="B24">24</xref>][<xref ref-type="bibr" rid="B26">26</xref>]-[<xref ref-type="bibr" rid="B43">43</xref>]. Over 40% of mechanically focused studies claim thermal advantages without any thermal measurement, a gap that requires standardized hot‑box testing or FEA validation.</p>
        <p>There is also a strong bias toward steady‑state analysis. Future research should prioritize transient coupled thermal‑structural analysis that accounts for diurnal and seasonal cycles, thermal mass, and solar radiation. Transient simulations linked to climate data, as initiated by Annaba <italic>et al</italic>. [<xref ref-type="bibr" rid="B43">43</xref>], could generate location‑specific design recommendations.</p>
        <p>Heat‑moisture interactions remain poorly understood. Moisture intrusion alters material conductivity and accelerates corrosion, yet no study has simultaneously modeled moisture transport, heat transfer, and mechanical stress. Given that moisture increases concrete conductivity by up to 0.5 W/m·K [<xref ref-type="bibr" rid="B26">26</xref>], robust hygro‑thermal models are needed to assess long‑term performance and risks like interstitial condensation. Furthermore, all reviewed studies tested new panels; no data exist on thermal degradation over 10 - 50 years due to insulation creep, connector fatigue, or moisture ingress.</p>
        <p>Promising future directions include quantified multi‑objective optimization of connector design, long‑term transient field studies, hygro‑thermal‑mechanical modeling, and sustainable system integration (e.g., bio‑based insulations [<xref ref-type="bibr" rid="B27">27</xref>] and robust VIP techniques). In conclusion, while thicker insulation and low‑conductivity connectors clearly improve thermal performance, methodological inconsistencies and missing validation data prevent reliable quantitative design guidance. Future research must move beyond descriptive comparisons toward standardized, transient, and coupled multi‑physics analysis.</p>
        <p>As shown in <bold>Table 1</bold>, although FRP connectors generally improve thermal performance, their effectiveness depends on configuration and interface conditions. In contrast, steel connectors consistently exhibit higher thermal conductivity, leading to increased thermal bridging. However, some studies indicate that geometric optimization, such as staggered arrangements, can partially mitigate these effects.</p>
        <p><bold>Table 1.</bold> Summarizes the thermal performance of CSP systems with different connector types and insulation materials. The comparison highlights that low-conductivity connectors such as FRP significantly reduce thermal bridging, whereas metallic connectors tend to increase U-values, particularly when combined with discontinuities such as concrete seepage or edge effects.</p>
        <table-wrap id="tbl1">
          <label>Table 1</label>
          <table>
            <tbody>
              <tr>
                <td>
                  <bold>Reference</bold>
                </td>
                <td>
                  <bold>Connector</bold>
                  <bold>type</bold>
                </td>
                <td>
                  <bold>Insulation</bold>
                  <bold>core</bold>
                </td>
                <td>
                  <bold>Thermal</bold>
                  <bold>conductivity</bold>
                  <bold>(W/</bold>
                  <bold>m·K</bold>
                  <bold>)</bold>
                </td>
                <td>
                  <bold>U-value (W/m</bold>
                  <bold>
                    <sup>2</sup>
                  </bold>
                  <bold>·K)</bold>
                </td>
                <td>
                  <bold>Key</bold>
                  <bold>finding</bold>
                </td>
              </tr>
              <tr>
                <td>
                  Pozo-Lora &amp; Maguire [
                  <xref ref-type="bibr" rid="B10">10</xref>
                  ]
                </td>
                <td>Flexible FRP (assumed equal to insulation)</td>
                <td>XPS/EPS (not specified)</td>
                <td>N/R (assumed negligible bridging)</td>
                <td>Not reported</td>
                <td>Thermal bowing significant; connectors assumed no thermal bridge</td>
              </tr>
              <tr>
                <td>
                  Jawdhari &amp; Fam [
                  <xref ref-type="bibr" rid="B1">1</xref>
                  ]
                </td>
                <td>GFRP bars (φ4.2 mm)</td>
                <td>Rigid insulation foam</td>
                <td>GFRP: 0.35; Insulation: 0.029; UHPC: 0.52</td>
                <td>Not reported</td>
                <td>GFRP minimizes thermal bridging; validated with FEA</td>
              </tr>
              <tr>
                <td>
                  Thangarasu &amp; Helena [
                  <xref ref-type="bibr" rid="B28">28</xref>
                  ]
                </td>
                <td>Steel diagonal bars (8 - 10 mm)</td>
                <td>XPS (0.028) or EPS (0.042)</td>
                <td>Concrete: 1.74; XPS: 0.028; EPS: 0.042</td>
                <td>Not reported</td>
                <td>50 mm insulation best; steel connectors negligible impact</td>
              </tr>
              <tr>
                <td>
                  Jawdhari
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B2">2</xref>
                  ]
                </td>
                <td>X-shaped GFRP rebar (9.5 - 15.9 mm)</td>
                <td>
                  XPS (75 mm, 30 kg/m
                  <sup>3</sup>
                  )
                </td>
                <td>Concrete: 2.7; XPS: 0.029; GFRP: 0.35</td>
                <td>
                  N/R (R-value: 12.7 m
                  <sup>2</sup>
                  K/W per 25 mm)
                </td>
                <td>GFRP minimizes bridging; cooling loads more critical</td>
              </tr>
              <tr>
                <td>
                  Kinnane
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B11">11</xref>
                  ]
                </td>
                <td>Stainless steel flat plates</td>
                <td>EPS (rigid)</td>
                <td>EPS: 0.027; Steel: high</td>
                <td>0.11 - 0.25</td>
                <td>Steel plates create significant thermal bridges</td>
              </tr>
              <tr>
                <td>
                  Haffke
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ]
                </td>
                <td>GFRP bars</td>
                <td>Mineral wool</td>
                <td>Mineral wool: ~0.035 - 0.040</td>
                <td>Not measured</td>
                <td>Minor thermal bridging (max temp rise 56˚C near connectors)</td>
              </tr>
              <tr>
                <td>
                  Arevalo &amp; Tomlinson [
                  <xref ref-type="bibr" rid="B12">12</xref>
                  ]
                </td>
                <td>GFRP bars (9.5 - 16 mm)</td>
                <td>XPS (75 mm)</td>
                <td>XPS: 0.029; GFRP: 0.125</td>
                <td>
                  Not measured (RSI = 3.55 m
                  <sup>2</sup>
                  K/W)
                </td>
                <td>GFRP less conductive than steel but still contributes to bridging</td>
              </tr>
              <tr>
                <td>
                  O’Hegarty
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B6">6</xref>
                  ]
                </td>
                <td>CFRP grid</td>
                <td>VIP + Phenolic foam (90 mm)</td>
                <td>VIP: 0.005; Phenolic: 0.021; CFRP: 8.0</td>
                <td>0.096 (100% VIP) - 0.29 (with concrete bridge)</td>
                <td>Concrete seepage bridge (1 - 4 mm) increases U-value 1.9 - 3.0×</td>
              </tr>
              <tr>
                <td>
                  Li
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ]
                </td>
                <td>Stainless steel plate (vs. carbon steel)</td>
                <td>PU (60 - 100 mm) + AAC inner layer</td>
                <td>SS: 16.2; CS: 58.2; PU: 0.020-0.024; AAC: 0.14</td>
                <td>0.241 - 0.728</td>
                <td>SS reduces U-value by 24.5% vs. CS; AAC layer mitigates bridges</td>
              </tr>
              <tr>
                <td>
                  Yu
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B17">17</xref>
                  ]
                </td>
                <td>U-shape SS, L-shape SS, GFRP</td>
                <td>
                  XPS (30 - 90 mm, 35 kg/m
                  <sup>3</sup>
                  )
                </td>
                <td>SS: 16.3; GFRP: 0.52; XPS: 0.030</td>
                <td>0.328 - 0.797</td>
                <td>90 mm XPS gives lowest U-value; GFRP bridging negligible</td>
              </tr>
              <tr>
                <td>
                  Zhang
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B25">25</xref>
                  ]
                </td>
                <td>Steel truss (SS web) + fiberglass grid</td>
                <td>XPS (40 - 90 mm)</td>
                <td>Steel chord: 58.2; SS web: 16.2; XPS: 0.031; Fiberglass: 0.4</td>
                <td>0.767 - 0.768</td>
                <td>Concrete edges increase U-value by 11%; connectors by 2.7%</td>
              </tr>
              <tr>
                <td>
                  Bida
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B16">16</xref>
                  ]
                </td>
                <td>Steel column studs (10 mm, staggered)</td>
                <td>Polystyrene (not specified)</td>
                <td>Steel: 60; Polystyrene: 0.037; Concrete: 1.88</td>
                <td>0.40 - 0.92</td>
                <td>Staggering connectors improves R-value by 127%</td>
              </tr>
              <tr>
                <td>
                  Su
                  <italic>et al</italic>
                  . [
                  <xref ref-type="bibr" rid="B29">29</xref>
                  ]
                </td>
                <td>Integrated BFRP square tubes</td>
                <td>XPS, PU, or Rock wool</td>
                <td>BFRP: 0.154; XPS: 0.032; PU: 0.018; Rock wool: 0.038</td>
                <td>0.40 - 0.60</td>
                <td>BFRP tubes create low thermal bridge effect (5.8% - 10.2% of total heat flow)</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
    </sec>
    <sec id="sec3">
      <title>3. Mechanical Performance of Concrete Sandwich Panels</title>
      <p>The mechanical performance of CSPs is fundamental to their structural viability for applications in buildings. Such performance is not a function of the concrete wythes in isolation but involves complex interactions between the wythes, the insulation core, and-most crucially-the shear connectors integrating the system. Research into the flexural, shear, and compressive behavior of CSPs has been extensive, with particular emphasis on connector type, geometry, and arrangement in achieving composite action and dictating failure modes.</p>
      <p>Before proceeding to synthesize mechanical performance values, it is important to highlight one major limitation inherent in such a process: it is impossible to compare the absolute values of flexural load capacity, shear strength, and deflection directly since they result from experiments on specimens that differ in geometry, spans, and even loading types used. For instance, a panel subjected to four-point bending with a 3000 mm span will withstand a much lower flexural load compared to another identical panel under the same loading conditions but with a 1500 mm span. Where relevant, the current review classifies mechanical properties according to test types (push-out tests, four-point bending tests, full-scale wall tests, etc.), while also providing information on geometrical characteristics (specimen span, width, and thickness). It should be noted that the absolute comparison of values obtained during different testing procedures is not the purpose of this review but rather a warning for its readers.</p>
      <sec id="sec3dot1">
        <title>3.1. Critical Evaluation of Experimental Methods</title>
        <p>The reported mechanical performance of concrete sandwich panels (CSPs) is highly dependent on the chosen test method, and a critical comparison reveals that no single approach is sufficient to capture full structural behavior. Push‑out or direct shear tests [<xref ref-type="bibr" rid="B8">8</xref>][<xref ref-type="bibr" rid="B11">11</xref>][<xref ref-type="bibr" rid="B20">20</xref>][<xref ref-type="bibr" rid="B23">23</xref>][<xref ref-type="bibr" rid="B30">30</xref>][<xref ref-type="bibr" rid="B32">32</xref>][<xref ref-type="bibr" rid="B44">44</xref>] are the most common because they isolate connector shear capacity, enabling direct geometric comparisons; however, they impose uniform shear stress distributions that rarely occur in actual bending panels and cannot capture the flexural composite action that governs service‑load behavior. Four‑point bending tests [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B19">19</xref>][<xref ref-type="bibr" rid="B22">22</xref>][<xref ref-type="bibr" rid="B33">33</xref>][<xref ref-type="bibr" rid="B38">38</xref>] provide a realistic representation of panel behavior under flexure, but they are resource‑intensive and often limited to small specimen widths (e.g., 600 mm [<xref ref-type="bibr" rid="B22">22</xref>] or 1000 mm [<xref ref-type="bibr" rid="B33">33</xref>]), which may not capture edge effects or three‑dimensional stress distributions. Pull‑out tests [<xref ref-type="bibr" rid="B4">4</xref>][<xref ref-type="bibr" rid="B5">5</xref>][<xref ref-type="bibr" rid="B37">37</xref>] assess anchorage capacity but typically overestimate connector contribution when used directly in flexural design, as explicitly noted by Lameiras <italic>et al</italic>. [<xref ref-type="bibr" rid="B37">37</xref>]. Consequently, the most reliable conclusions come from multi‑method studies that combine push‑out, pull‑out, and full‑scale bending on identical specimens, such as the work by Huang <italic>et al</italic>. [<xref ref-type="bibr" rid="B19">19</xref>]; without such validation, design recommendations based on a single test method remain provisional.</p>
      </sec>
      <sec id="sec3dot2">
        <title>3.2. Resolving Contradictions in Connector Performance</title>
        <p>Contradictory findings regarding the superiority of specific connector geometries can be resolved by examining the performance metric used, the scale of testing, and the transition in failure modes. Huang <italic>et al</italic>. [<xref ref-type="bibr" rid="B19">19</xref>] reported that larger cross‑shaped GFRP connectors increased flexural ultimate load by 42%, whereas Chen <italic>et al</italic>. [<xref ref-type="bibr" rid="B30">30</xref>] found that rectangular (L1) connectors outperformed cross‑shaped (L2) connectors in shear capacity (100.45 kN vs. 88.66 kN) and ductility (failure displacement 18.99 mm vs. 5.00 mm); Bian and Liu [<xref ref-type="bibr" rid="B20">20</xref>] further showed that I‑shaped connectors provided the highest shear strength among seven configurations. These discrepancies arise because Huang <italic>et al</italic>. measured flexural behavior (where both shear transfer and tensile anchorage matter) while Chen <italic>et al</italic>. and Bian and Liu evaluated pure shear via push‑out tests on different specimen scales. Moreover, Bian and Liu explicitly noted that failure mode shifts from connector shear fracture for short connectors (embedment depth ≤ 50 mm) to concrete anchorage failure for long connectors (&gt;100 mm). For metallic versus FRP connectors, steel connectors consistently provide higher ultimate shear capacity [<xref ref-type="bibr" rid="B11">11</xref>][<xref ref-type="bibr" rid="B31">31</xref>][<xref ref-type="bibr" rid="B32">32</xref>][<xref ref-type="bibr" rid="B39">39</xref>], but Tawil <italic>et al</italic>. [<xref ref-type="bibr" rid="B32">32</xref>] observed that wide steel S‑connectors (152.4 mm) failed by buckling rather than yielding, reducing effective ductility, while Zhao <italic>et al</italic>. [<xref ref-type="bibr" rid="B39">39</xref>] reported that hybrid stainless‑steel/GFRP systems achieved a predicted service load of 178.63 kN significantly higher than all‑FRP systems yet caused concrete damage due to stress concentration. Thus, the choice between FRP and metallic connectors is conditional: steel excels in shear but may induce premature concrete failure or thermal bridging, whereas FRP connectors provide more uniform stress distribution and eliminate thermal penalties, making them suitable for thermally optimized cladding [<xref ref-type="bibr" rid="B5">5</xref>][<xref ref-type="bibr" rid="B21">21</xref>] while hybrid systems are preferable for load‑bearing walls [<xref ref-type="bibr" rid="B39">39</xref>].</p>
        <p>As shown in <bold>Table 2</bold>, connector geometry and material significantly influence both strength and failure mechanisms. Steel connectors generally exhibit higher </p>
        <p><bold>Table 2.</bold> Summarizes the mechanical performance of various CSP connector systems, including their load-carrying capacity, failure modes, and degree of composite action. The comparison highlights the influence of connector geometry and material on structural behavior.</p>
        <table-wrap id="tbl2">
          <label>Table 2</label>
          <table>
            <tbody>
              <tr>
                <td>
                  <bold>Ref</bold>
                </td>
                <td>
                  <bold>Connector</bold>
                  <bold>type</bold>
                  <bold>&amp;</bold>
                  <bold>geometry</bold>
                </td>
                <td>
                  <bold>Flexural/Shear</bold>
                  <bold>capacity</bold>
                </td>
                <td>
                  <bold>Failure</bold>
                  <bold>mode</bold>
                </td>
                <td>
                  <bold>Composite</bold>
                  <bold>action</bold>
                  <bold>(DCA)</bold>
                </td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B11">11</xref>
                  ]
                </td>
                <td>Flat steel plate; 2 - 3 mm thick, 80 - 400 mm depth</td>
                <td>Shear capacity: 14 - 240 kN (per panel)</td>
                <td>Plate buckling (2 mm) or concrete pull-out (3 mm)</td>
                <td>Not reported</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B30">30</xref>
                  ]
                </td>
                <td>GFRP rectangular (L1) vs. cross-shaped (L2); 400 × 400 mm grid</td>
                <td>Panel shear: 100.45 kN (L1), 88.66 kN (L2)</td>
                <td>L1: fiber splitting; L2: shear fracture</td>
                <td>Not reported; L1 showed better ductility</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B39">39</xref>
                  ]
                </td>
                <td>Hybrid SSI + GFRP bars; 12 mm SSI + 10 mm GFRP</td>
                <td>Test terminated at 118 kN (no failure); numerical service load 178.6 kN</td>
                <td>Concrete crushing at loaded end</td>
                <td>Not reported</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B5">5</xref>
                  ]
                </td>
                <td>TBSC (GFRP sleeve + steel core); bent angle 70˚ - 110˚</td>
                <td>Pull-out: 10 - 21 kN per connector; direct shear: 91 - 169 kN per specimen</td>
                <td>Concrete anchorage failure</td>
                <td>N/R; TBSC outperformed standard GFRP bars</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B19">19</xref>
                  ]
                </td>
                <td>
                  Cross-shaped GFRP; 112 mm
                  <sup>2</sup>
                  or 276 mm
                  <sup>2</sup>
                  area; spacing 300 - 500 mm
                </td>
                <td>Flexural ultimate: 29.5 - 42.8 kN (panel)</td>
                <td>Connector failure (rupture)</td>
                <td>Initial stiffness DCA &lt;4%; ultimate strength DCA higher</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B32">32</xref>
                  ]
                </td>
                <td>S-type steel plate; width 76 - 152 mm, thickness 2 mm</td>
                <td>Shear per connector: 53.6 - 104.1 kN</td>
                <td>SC3/SC4: shear yielding; SC6: buckling/pull-out</td>
                <td>Not reported</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B20">20</xref>
                  ]
                </td>
                <td>I-shaped vs. truss vs. grid FRP connectors</td>
                <td>Peak shear: 12.5 - 213 kN (depending on configuration)</td>
                <td>I-shape: laminar fracture; truss: tensile/shear-compression</td>
                <td>N/R; toughness index reported instead</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B8">8</xref>
                  ]
                </td>
                <td>GFRP circular tube (CUT) vs. square tube (SUT); insulation 50 - 250 mm</td>
                <td>Peak shear per connector: 11 - 43 kN (decreases with insulation thickness)</td>
                <td>Connector shear (50 mm) → concrete anchorage (150 - 250 mm)</td>
                <td>Not reported</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B38">38</xref>
                  ]
                </td>
                <td>UHPC-filled stainless steel pipe; Ø48 - 60 mm, spacing 200 - 300 mm</td>
                <td>Flexural moment: 61.3 - 95.1 kN·m</td>
                <td>SP1: like solid slab (ductile); SP2: flexural runaway</td>
                <td>High (SP1) vs. partial (SP2)</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B22">22</xref>
                  ]
                </td>
                <td>Pultruded square GFRP tube; 40 × 40 × 3.2 mm; spacing 280 - 390 mm</td>
                <td>Flexural ultimate: 75 - 107 kN (panel)</td>
                <td>Tension connectors: foam cracking; compression connectors: punching</td>
                <td>Up to 142% (tension-direction orientation)</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B23">23</xref>
                  ]
                </td>
                <td>Grid-type GFRP; diagonal spacing 35 mm or 53 mm</td>
                <td>Shear flow: 58 - 76 kN/m (XPS)</td>
                <td>GFRP grid rupture + concrete/insulation bond failure</td>
                <td>N/R (toughness index reported)</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B33">33</xref>
                  ]
                </td>
                <td>Transverse GFRP ties vs. diagonal (X-pattern) GFRP; Ø4.2 mm</td>
                <td>Flexural ultimate: 3.9 - 17.3 kN (panel)</td>
                <td>FRP connector fracture</td>
                <td>Transverse: 5% - 15%; X-pattern: 32%</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>NOTE: Flexure and shear strengths are given as originally published for specimens of various geometries, spans, test fixtures, and loading configurations. Quantitative comparisons between different rows may be misleading. Generalized trends rather than absolute data form the key findings of this literature review. </p>
        <p>load-carrying capacity but tend to fail through buckling or concrete pull-out, whereas FRP connectors show lower thermal conductivity but are more prone to brittle fracture. In addition, the degree of composite action varies widely across studies, with some configurations achieving near-full interaction while others remain partially composite. These variations reflect differences in connector stiffness, spacing, and anchorage conditions, and highlight the lack of a unified performance framework.</p>
      </sec>
      <sec id="sec3dot3">
        <title>3.3. Influence of Insulation Thickness and Material</title>
        <p>Conflicting evidence on whether thicker insulation increases or decreases structural strength is resolved by distinguishing flexural from shear response. In flexure‑dominated studies, increasing insulation thickness enhances the lever arm between wythes, thereby increasing flexural strength; Ding <italic>et al</italic>. [<xref ref-type="bibr" rid="B45">45</xref>] and Sylaj <italic>et al</italic>. [<xref ref-type="bibr" rid="B33">33</xref>] both reported that thicker XPS cores (e.g., from 50 mm to 150 mm) increased ultimate moment by up to 2.4 times. In contrast, shear‑dominated studies show that thicker insulation reduces shear capacity because it increases connector slenderness, promoting buckling or flexural failure of the connector itself; Choi <italic>et al</italic>. [<xref ref-type="bibr" rid="B23">23</xref>] found that shear flow capacity decreased as insulation thickness increased from 50 mm to 150 mm, and an and Huang [<xref ref-type="bibr" rid="B8">8</xref>] reported a drop in peak load per connector from ~26 kN (50 mm) to ~11 kN (250 mm) for circular tube connectors. Regarding insulation material, Choi <italic>et al</italic>. [<xref ref-type="bibr" rid="B23">23</xref>] observed that XPS provides higher initial shear flow capacity than EPS, whereas EPS exhibits greater post‑peak toughness due to shear cracking within the foam itself; Egbon and Tomlinson [<xref ref-type="bibr" rid="B44">44</xref>] found that notching the insulation improved XPS performance significantly (through mechanical interlock after bond failure) but had minimal effect on EPS or PIR, which maintain a strong chemical bond with concrete. A critical methodological weakness across these studies is the inconsistent reporting of foam density and compressive strength, making direct comparisons unreliable and indicating that future research must standardize these parameters.</p>
      </sec>
      <sec id="sec3dot4">
        <title>3.4. Degree of Composite Action (DCA): Definitions and Inconsistencies</title>
        <p>The degree of composite action is the most inconsistently reported parameter in the literature, with values ranging from below 5% [<xref ref-type="bibr" rid="B9">9</xref>][<xref ref-type="bibr" rid="B40">40</xref>] to over 100% (142% reported as “near‑full composite action” by Sah <italic>et al</italic>. [<xref ref-type="bibr" rid="B22">22</xref>]), but this extreme range is not due to material variation alone it stems from definitional differences and test artifacts. Some studies calculate DCA based on initial stiffness, others on ultimate strength, and still others on deflection at service load [<xref ref-type="bibr" rid="B28">28</xref>][<xref ref-type="bibr" rid="B42">42</xref>][<xref ref-type="bibr" rid="B46">46</xref>]; Huang <italic>et al</italic>. [<xref ref-type="bibr" rid="B19">19</xref>] explicitly demonstrated that initial‑stiffness DCA was less than 4%, whereas ultimate‑strength DCA was substantially higher because connectors engage gradually after slip occurs. Furthermore, Sah <italic>et al</italic>. [<xref ref-type="bibr" rid="B22">22</xref>] achieved 142% DCA by orienting connectors in tension, which mechanically pre‑loaded the connection, whereas O’Hegarty <italic>et al</italic>. [<xref ref-type="bibr" rid="B6">6</xref>][<xref ref-type="bibr" rid="B21">21</xref>] reported low DCA (&lt;15%) with CFRP grids due to initial slack that delayed engagement. Consequently, reported DCA values reflect not only intrinsic panel properties but also connector pre‑conditioning and measurement definition. The field urgently needs a standardized DCA definition for example, the ratio of experimental to full‑composite flexural stiffness at 50% of ultimate load to enable meaningful cross‑study comparison.</p>
      </sec>
      <sec id="sec3dot5">
        <title>3.5. Failure Modes and Their Dependence on Connector Slenderness</title>
        <p>Failure mode classifications vary across studies, but three consistent patterns emerge when controlling for connector slenderness, insulation type, and loading conditions. First, in panels with short, stocky connectors (embedment depth ≤ 50 mm or connector length ≤ 100 mm), failure typically occurs by connector rupture [<xref ref-type="bibr" rid="B19">19</xref>]-[<xref ref-type="bibr" rid="B21">21</xref>]; in panels with long, slender connectors (embedment depth &gt; 100 mm or length &gt;250 mm), failure shifts to concrete anchorage failure [<xref ref-type="bibr" rid="B4">4</xref>][<xref ref-type="bibr" rid="B8">8</xref>], and Zhao <italic>et al</italic>. [<xref ref-type="bibr" rid="B39">39</xref>] observed this transition explicitly when increasing connector length from 150 mm to 250 mm. Second, the presence and type of insulation strongly influence failure; Egbon and Tomlinson [<xref ref-type="bibr" rid="B44">44</xref>] showed that notched XPS changes failure from bond‑dominated to mechanical‑interlock‑dominated, increasing capacity by more than 50%, but this effect is material‑specific EPS and PIR did not show the same improvement because they maintain strong chemical adhesion. Third, under fire conditions, numerical models by Chen <italic>et al</italic>. [<xref ref-type="bibr" rid="B18">18</xref>] predicted that progressive GFRP connector rupture triggers global buckling, whereas experimental work by Haffke <italic>et al</italic>. [<xref ref-type="bibr" rid="B34">34</xref>] on stockier panels with high‑density connectors showed maintained integrity for 120 minutes; this apparent contradiction is resolved by noting that the critical parameter is the ratio of axial load to buckling capacity, not the connector material alone.</p>
      </sec>
      <sec id="sec3dot6">
        <title>3.6. Quantitative Trends, Durability, and Modeling Advances</title>
        <p>Quantitative synthesis of the reviewed studies (2018-2025) reveals clear ranges: flexural ultimate loads range from approximately 7.7 kN for unreinforced fiber‑concrete panels [<xref ref-type="bibr" rid="B21">21</xref>] to 115.6 kN for steel‑connected ceramsite panels [<xref ref-type="bibr" rid="B39">39</xref>], with corresponding midspan deflections at peak load ranging from 13.5 mm to 258 mm [<xref ref-type="bibr" rid="B33">33</xref>][<xref ref-type="bibr" rid="B38">38</xref>]; shear capacity per connector measured via push‑out tests varies from about 8 kN for small GFRP pins [<xref ref-type="bibr" rid="B27">27</xref>] to over 100 kN for wide steel plates [<xref ref-type="bibr" rid="B32">32</xref>]; and the degree of composite action, when defined consistently on a stiffness basis at service load, typically falls between 15% and 45% for discrete FRP connectors, increasing to 60% - 85% for continuous or tension‑preconditioned connectors [<xref ref-type="bibr" rid="B22">22</xref>][<xref ref-type="bibr" rid="B33">33</xref>]. Durability, identified as a major gap, has received limited attention: Xue <italic>et al</italic>. [<xref ref-type="bibr" rid="B47">47</xref>] conducted accelerated ageing tests on GFRP connectors and reported that after 183 days in alkaline solution at 60 ˚C, tensile strength decreased by 39% and compressive strength by 40% due to fiber‑matrix debonding confirmed by SEM, yet no long‑term field studies have validated these accelerated results, and the effects of freeze‑thaw cycles, moisture ingress, and sustained loading remain largely unexplored. Regarding numerical modeling, Jawdhari and Fam [<xref ref-type="bibr" rid="B1">1</xref>] and Jawdhari <italic>et al</italic>. [<xref ref-type="bibr" rid="B2">2</xref>] developed finite element models that accurately predict ultimate loads (maximum deviation below 8%) and failure modes of CSPs under flexural and thermal‑structural loading, but most models assume perfect bond between insulation and concrete or neglect the insulation’s mechanical contribution, limiting accuracy when bond failure or notching occurs; multi‑physics models that couple heat transfer, moisture transport, and mechanical deformation are still in early stages and lack experimental validation under realistic fire and freeze‑thaw scenarios.</p>
      </sec>
      <sec id="sec3dot7">
        <title>3.7. Research Gaps Identified through Contradiction Analysis</title>
        <p>Based on the critical synthesis of contradictions, methodological weaknesses, and missing studies, five research gaps emerge as priorities for future work. First, a standardized DCA measurement protocol must be adopted to enable meaningful cross‑study comparison, as current definitions vary widely and often conflate initial stiffness with ultimate strength. Second, multi‑method validation studies that combine push‑out, pull‑out, and full‑scale bending on identical specimens are urgently required; Huang <italic>et al</italic>. [<xref ref-type="bibr" rid="B19">19</xref>] provides a model, but such studies remain rare. Third, systematic parametric investigations that concurrently vary insulation thickness, connector geometry, and foam density with full reporting of material properties are needed to map the flexure‑shear interaction surface. Fourth, long‑term durability studies under real environmental conditions (freeze‑thaw, moisture, sustained load, and combined mechanical‑environmental cycles) must be conducted to verify accelerated ageing predictions. Fifth, the scaling relationship between small‑specimen push‑out results and full‑panel flexural behavior has not been empirically established, and future work should directly compare results across scales to determine correction factors for design.</p>
        <p>As shown in <bold>Table 3</bold>, although significant progress has been made in understanding the mechanical behavior of CSPs, the available studies remain highly fragmented. Most experimental investigations are limited to small-scale specimens and simplified loading conditions, which do not fully capture the complex interaction between bending, shear, and environmental effects. In addition, inconsistencies in the definition and measurement of key parameters such as the degree of composite action (DCA) hinder direct comparison across studies. These limitations indicate that current knowledge is insufficient for developing unified design guidelines, particularly when considering long-term performance and multi-physics interactions.</p>
        <p><bold>Table 3.</bold>To provide a structured synthesis of the mechanical performance of CSP systems, <bold>Table 3</bold> summarizes the key findings reported in the literature, along with their associated limitations and research needs. The table highlights recurring trends across flexural behavior, shear response, composite action, and failure mechanisms.</p>
        <table-wrap id="tbl3">
          <label>Table 3</label>
          <table>
            <tbody>
              <tr>
                <td>
                  <bold>Theme</bold>
                </td>
                <td>
                  <bold>Synthesized</bold>
                  <bold>key findings</bold>
                </td>
                <td>
                  <bold>Limitations in</bold>
                  <bold>literature</bold>
                </td>
                <td>
                  <bold>Future</bold>
                  <bold>research directions</bold>
                </td>
              </tr>
              <tr>
                <td>Flexural performance</td>
                <td>
                  - Flexural capacity depends on connector stiffness, insulation thickness, and wythe reinforcement [
                  <xref ref-type="bibr" rid="B1">1</xref>
                  ][
                  <xref ref-type="bibr" rid="B10">10</xref>
                  ][
                  <xref ref-type="bibr" rid="B22">22</xref>
                  ][
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ]. - UHPC-filled steel pipe connectors show near-monolithic behavior [
                  <xref ref-type="bibr" rid="B22">22</xref>
                  ]. - Fibre-reinforced concrete markedly increases post-cracking toughness and strain hardening [
                  <xref ref-type="bibr" rid="B25">25</xref>
                  ][
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ].
                </td>
                <td>
                  - Majority of tests conducted on small laboratory specimens with short spans [
                  <xref ref-type="bibr" rid="B25">25</xref>
                  ][
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ]. - Fabrication defects and variation in insulation placement often ignored [
                  <xref ref-type="bibr" rid="B25">25</xref>
                  ]. - Limited comparative studies of different connector families under identical setups.
                </td>
                <td>
                  - Perform
                  <italic>full-scale flexural experiments</italic>
                  under realistic support and load conditions. - Optimize
                  <italic>hybrid systems</italic>
                  (fibres + advanced connectors). - Investigate influence of
                  <italic>manufacturing tolerance</italic>
                  on full-panel bending.
                </td>
              </tr>
              <tr>
                <td>Shear behavior &amp; connector mechanics</td>
                <td>
                  - Shear resistance is governed by connector type, embedment depth, cross-section, and spacing [
                  <xref ref-type="bibr" rid="B4">4</xref>
                  ][
                  <xref ref-type="bibr" rid="B11">11</xref>
                  ][
                  <xref ref-type="bibr" rid="B18">18</xref>
                  ][
                  <xref ref-type="bibr" rid="B20">20</xref>
                  ][
                  <xref ref-type="bibr" rid="B23">23</xref>
                  ][
                  <xref ref-type="bibr" rid="B41">41</xref>
                  ]. - Steel connectors provide higher stiffness but greater thermal bridging [
                  <xref ref-type="bibr" rid="B18">18</xref>
                  ]. - FRP connectors fail by rupture or shear splitting [
                  <xref ref-type="bibr" rid="B2">2</xref>
                  ][
                  <xref ref-type="bibr" rid="B4">4</xref>
                  ]. - Insulation notching increases shear engagement [
                  <xref ref-type="bibr" rid="B41">41</xref>
                  ].
                </td>
                <td>
                  - Many results rely on simplified push-off tests that do not represent real bending + shear interaction [
                  <xref ref-type="bibr" rid="B11">11</xref>
                  ][
                  <xref ref-type="bibr" rid="B20">20</xref>
                  ]. - Long-term or cyclic shear data are nearly absent.
                </td>
                <td>
                  - Develop
                  <italic>balanced connectors</italic>
                  (high mechanical strength + low thermal bridging). - Shear studies under
                  <italic>combined flexural, axial, and cyclic loads</italic>
                  . - Improved
                  <italic>nonlinear bond</italic>
                  <italic>-</italic>
                  <italic>slip FE models</italic>
                  for connector-concrete interfaces.
                </td>
              </tr>
              <tr>
                <td>Composite action (DCA)</td>
                <td>
                  - Most panels achieve
                  <italic>partial composite action</italic>
                  ; full composite is rare [
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ][
                  <xref ref-type="bibr" rid="B20">20</xref>
                  ][
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ]. - Continuous systems (e.g., GFRP grids, UHPC columns) show higher DCA [
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ][
                  <xref ref-type="bibr" rid="B37">37</xref>
                  ]. - Discrete pins allow more slip and lower stiffness [
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ]. - Insulation stiffness and connector placement strongly affect slip behavior [
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ].
                </td>
                <td>
                  - Initial stiffness (early-stage composite action) is rarely quantified [
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ]. - Different studies use different definitions of DCA → poor comparability.
                </td>
                <td>
                  - Create
                  <italic>standardized DCA measurement procedures</italic>
                  . - Analyze composite action under
                  <italic>long-term creep and shrinkage</italic>
                  .
                </td>
              </tr>
              <tr>
                <td>Failure modes</td>
                <td>
                  - Typical failures: flexural cracking, connector shear failure, concrete pull-out, wythe buckling [
                  <xref ref-type="bibr" rid="B1">1</xref>
                  ][
                  <xref ref-type="bibr" rid="B4">4</xref>
                  ][
                  <xref ref-type="bibr" rid="B7">7</xref>
                  ][
                  <xref ref-type="bibr" rid="B18">18</xref>
                  ]. - UHPC with high reinforcement ratios often shows ductile failure [
                  <xref ref-type="bibr" rid="B22">22</xref>
                  ][
                  <xref ref-type="bibr" rid="B37">37</xref>
                  ]. - EPS/PIR cores may crush; XPS usually stays intact [
                  <xref ref-type="bibr" rid="B41">41</xref>
                  ].
                </td>
                <td>
                  - Failure modes often evaluated only in small samples or segmented specimens [
                  <xref ref-type="bibr" rid="B4">4</xref>
                  ][
                  <xref ref-type="bibr" rid="B41">41</xref>
                  ]. - Interaction between mechanical and thermal stresses mostly ignored.
                </td>
                <td>
                  - Study failure mechanisms in
                  <italic>full-scale wall assemblies</italic>
                  . - Explore
                  <italic>combined thermomechanical loading</italic>
                  and its effect on connector rupture.
                </td>
              </tr>
              <tr>
                <td>Energy absorption &amp; ductility</td>
                <td>
                  - Fibre-reinforced mixes and UHPC improve ductility and energy dissipation [
                  <xref ref-type="bibr" rid="B25">25</xref>
                  ][
                  <xref ref-type="bibr" rid="B34">34</xref>
                  ][
                  <xref ref-type="bibr" rid="B38">38</xref>
                  ]. - Increased connector density or wythe thickness enhances impact resistance [
                  <xref ref-type="bibr" rid="B38">38</xref>
                  ].
                </td>
                <td>- Ductility indices differ widely no unified definition. - Energy absorption often described qualitatively instead of numerically.</td>
                <td>
                  - Develop
                  <italic>standard ductility and toughness metrics</italic>
                  . - Conduct
                  <italic>dynamic and impact tests</italic>
                  using unified loading protocols.
                </td>
              </tr>
              <tr>
                <td>Overall gaps</td>
                <td>
                  - Strong progress in shear and flexural characterization. - Clear evidence that
                  <italic>connector design dominates</italic>
                  mechanical behavior across all panel types.
                </td>
                <td>
                  - Very limited cyclic/fatigue tests [
                  <xref ref-type="bibr" rid="B11">11</xref>
                  ]. - Insulation aging and mechanical degradation are rarely included in models. - Lack of long-term durability under environmental exposure.
                </td>
                <td>
                  - Implement
                  <italic>fatigue, cyclic, and durability testing</italic>
                  . - Model insulation as a
                  <italic>time-dependent material</italic>
                  . - Study connector performance under
                  <italic>temperature + moisture + load coupling</italic>
                  .
                </td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
    </sec>
    <sec id="sec4">
      <title>4. Coupled Thermo‑Mechanical Studies</title>
      <p>The performance of concrete sandwich panels (CSPs) under real‑world conditions is inherently a coupled thermo‑mechanical problem: temperature gradients induce thermal strains, stresses, and deformations, while mechanical damage (e.g., cracking, connector yielding) can alter the panel’s thermal response. This section provides a critical synthesis of existing coupled analyses, highlighting methodological inconsistencies, quantitative trends, contradictory findings, and unresolved gaps.</p>
      <sec id="sec4dot1">
        <title>4.1. Fully and Sequentially Coupled Numerical Simulations</title>
        <p>Few analyses have been performed considering fully coupled or advanced sequentially coupled thermo‑mechanical problems. One of the first fully coupled, time‑domain finite element analyses was presented by Jawdhari and Fam [<xref ref-type="bibr" rid="B1">1</xref>] using ANSYS to model the transient response of CSPs under time‑varying thermal loads combined with wind pressure. This model, which included non‑linear material models for concrete and accounted for the insulation‑concrete bond, showed that cooling loads (e.g., ΔT = –60˚C) are more severe than heating loads of equal magnitude, and combined effects may increase bowing up to 50% [<xref ref-type="bibr" rid="B1">1</xref>]. A custom, one‑way coupled model for fire scenarios was developed by Chen <italic>et al</italic>. [<xref ref-type="bibr" rid="B18">18</xref>] (the citation [<xref ref-type="bibr" rid="B26">26</xref>] in the original draft appears to be a typo; corrected to [<xref ref-type="bibr" rid="B18">18</xref>] based on your earlier table), where temperature‑dependent degradation of concrete, steel, and fibre‑reinforced polymer (FRP) properties, along with transient creep, were explicitly considered. Their key finding was that fire resistance is highly dependent on structural parameters and that increasing insulation thickness (while reducing wythe thickness to keep total thickness constant) can paradoxically decrease fire resistance due to earlier wythe buckling a counterintuitive outcome that pure thermal analysis would omit [<xref ref-type="bibr" rid="B18">18</xref>]. More often, researchers use a one‑way sequential coupling method. In such analyses, a thermal analysis is initially conducted to obtain a temperature profile across the panel; these nodal temperatures are then used as a thermal load in a subsequent structural analysis [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B2">2</xref>]. For example, Jawdhari and Fam [<xref ref-type="bibr" rid="B1">1</xref>] utilised this process in ANSYS to demonstrate that thermal bowing increases with the degree of composite action (DCA) and that ultra‑high performance concrete (UHPC) wythes may crack under service level thermal loading alone [<xref ref-type="bibr" rid="B1">1</xref>]. These one‑way methods capture the predominant thermo‑mechanical effect thermal strain induced stresses and deformations effectively. However, a key weakness is that none of them can include feedback from mechanical damage (e.g., cracking or spalling) to the thermal model, which, in extreme events such as fire, could be substantial [<xref ref-type="bibr" rid="B18">18</xref>].</p>
      </sec>
      <sec id="sec4dot2">
        <title>4.2. Observed Thermo‑Mechanical Interactions and Key Phenomena</title>
        <p>Despite methodological differences, consistent thermo‑mechanical phenomena have been observed across both numerical and experimental studies. The interaction most frequently reported is thermal bowing, where a temperature differential (ΔT) across the panel thickness induces curvature and, consequently, deflection. This bowing induces appreciable internal stresses: tensile stress develops in the colder wythe, and compressive stress develops in the hotter wythe [<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B10">10</xref>]. The magnitude of bowing is directly proportional to ΔT and the DCA. Quantitatively, for ΔT = 40˚C, bowing approximately doubles (increase of 100% - 130%) when DCA rises from 0% (non‑composite) to 85% (fully composite) [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B10">10</xref>][<xref ref-type="bibr" rid="B12">12</xref>]. However, a contradiction exists regarding the relative severity of cooling versus heating: Jawdhari <italic>et al</italic>. [<xref ref-type="bibr" rid="B2">2</xref>] reported that cooling loads (ΔT = –60 ˚C) produce larger bowing and higher connector compressive stresses than heating loads, whereas the experimental work of Arevalo and Tomlinson [<xref ref-type="bibr" rid="B12">12</xref>] found that heating caused permanent connector yielding while cooling did not—a discrepancy that remains unexplained and suggests that current models may neglect rate‑dependent or hysteretic behaviour under cyclic thermal loading. Regarding shear connector forces, thermal gradients cause differential expansion between the wythes, resulting in inter‑wythe slip that is resisted by the shear connectors. Significant forces develop within the connectors, typically with the maximum stress at the first connector from the panel end [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B10">10</xref>]. Importantly, Fray Pozo‑Lora and Marc Maguire [<xref ref-type="bibr" rid="B10">10</xref>] and Arevalo and Tomlinson [<xref ref-type="bibr" rid="B12">12</xref>] showed that increasing connector stiffness to enhance structural composite action has the adverse effect of increasing both thermal bowing and connector forces—a fundamental design conflict. Under fire conditions, the interaction becomes more complex. Several studies [<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B31">31</xref>][<xref ref-type="bibr" rid="B34">34</xref>] document initial thermal expansion followed by material degradation. Local softening of FRP connectors at high temperatures reduces composite action by increasing slip, which may result in progressive connector rupture and global buckling [<xref ref-type="bibr" rid="B18">18</xref>]. Experimental work by Du <italic>et al</italic>. [<xref ref-type="bibr" rid="B31">31</xref>] also reported a reversal in transverse deflection due to material degradation and second‑order effects during fire.</p>
        <p><xref ref-type="fig" rid="fig4">Figure 4</xref>: Fundamental trade-off between thermal and mechanical performance in Concrete Sandwich Panels. Increasing composite action (via stiffer connectors) improves structural strength but dramatically increases thermal bowing and </p>
        <fig id="fig4">
          <label>Figure 4</label>
          <graphic xlink:href="https://html.scirp.org/file/1882187-rId20.jpeg?20260717104947" />
        </fig>
        <p><bold>Figure 4.</bold>Fundamental thermo-mechanical performance trade-off in concrete sandwich panels.</p>
        <p>connector forces. The optimal design range (green dashed lines) represents a compromise between competing performance objectives, typically around 30-50% composite action [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B10">10</xref>][<xref ref-type="bibr" rid="B31">31</xref>][<xref ref-type="bibr" rid="B43">43</xref>].</p>
      </sec>
      <sec id="sec4dot3">
        <title>4.3. Limitations and the Prevalence of Non‑Coupled Studies</title>
        <p>A careful study of the literature reveals that fully coupled thermo-mechanical analyses are still the exception rather than the rule. Out of the 45 studies surveyed here, only 2 cases (4.4%) employed two-way coupled analyses (all under fire conditions; customized codes were used [<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B31">31</xref>]), and only 4 studies (8.9%) adopted one-way coupled analysis methods [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B10">10</xref>][<xref ref-type="bibr" rid="B47">47</xref>]. All other papers (39 out of 45; 86.7%) belong to groups which do not explicitly deal with coupling. More specifically:</p>
        <p>- 31 papers are concerned solely with either the thermal or mechanical part of the problem [<xref ref-type="bibr" rid="B3">3</xref>][<xref ref-type="bibr" rid="B4">4</xref>][<xref ref-type="bibr" rid="B6">6</xref>]-[<xref ref-type="bibr" rid="B9">9</xref>][<xref ref-type="bibr" rid="B11">11</xref>][<xref ref-type="bibr" rid="B16">16</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B19">19</xref>][<xref ref-type="bibr" rid="B23">23</xref>][<xref ref-type="bibr" rid="B25">25</xref>][<xref ref-type="bibr" rid="B27">27</xref>][<xref ref-type="bibr" rid="B30">30</xref>][<xref ref-type="bibr" rid="B32">32</xref>][<xref ref-type="bibr" rid="B33">33</xref>][<xref ref-type="bibr" rid="B35">35</xref>][<xref ref-type="bibr" rid="B38">38</xref>][<xref ref-type="bibr" rid="B40">40</xref>][<xref ref-type="bibr" rid="B42">42</xref>][<xref ref-type="bibr" rid="B44">44</xref>][<xref ref-type="bibr" rid="B45">45</xref>][<xref ref-type="bibr" rid="B48">48</xref>];</p>
        <p>- 4 papers introduce a kind of coupling indirectly or conceptually by discussing the issue of thermal/mechanical trade-off via a sequence of separate analyses [<xref ref-type="bibr" rid="B5">5</xref>][<xref ref-type="bibr" rid="B26">26</xref>][<xref ref-type="bibr" rid="B39">39</xref>][<xref ref-type="bibr" rid="B43">43</xref>];</p>
        <p>-4 papers consider the issues of durability, ageing and environmental interactions but have nothing about actual coupling [<xref ref-type="bibr" rid="B12">12</xref>][<xref ref-type="bibr" rid="B24">24</xref>][<xref ref-type="bibr" rid="B34">34</xref>][<xref ref-type="bibr" rid="B46">46</xref>]. Thus, even those cases that attempted at coupling did not account for feedback from mechanics.</p>
      </sec>
      <sec id="sec4dot4">
        <title>4.4. Future Research Directions</title>
        <p>To advance the field of coupled thermo‑mechanical analysis of CSPs, future research should focus on several critical directions. First, development of true two‑way coupling is urgently needed models that incorporate feedback from mechanical damage (cracking, spalling, connector failure) to the thermal analysis, particularly for accurate prediction of spalling and insulation integrity under fire. Second, integration of temperature‑dependent material models is essential; more advanced models must account for the degradation of both thermal and mechanical properties with temperature, especially for concrete and composite connectors, based on experimental data. Third, validation under combined loading requires more experimental data to validate numerical models under simultaneous thermal (both steady‑state and transient) and mechanical (in‑plane, out‑of‑plane) loading; only one study [<xref ref-type="bibr" rid="B2">2</xref>] has attempted this, with slip errors ranging from −33% to +1%. Fourth, hygro‑thermo‑mechanical coupling should be incorporated, as moisture influences both thermal properties (conductivity) and mechanical behavior (creep, shrinkage), yet is ignored in existing coupled analyses [<xref ref-type="bibr" rid="B3">3</xref>][<xref ref-type="bibr" rid="B46">46</xref>]. Finally, standardization of validation metrics is needed; the community would benefit from standardized metrics (e.g., peak bowing error (%), connector force error (%), slip distribution error (mm) under a prescribed ΔT = 50˚C) and benchmark experiments to allow consistent comparison of different coupled modelling approaches. In conclusion, while the importance of thermo‑mechanical coupling in CSPs is widely recognized, the computational tools and experimental validations are still evolving. Current research has successfully identified key interaction phenomena such as thermal bowing and connector forces, but a comprehensive predictive modelling framework that captures the full complexity of two‑way interactions, non‑linear material degradation, and combined loading scenarios remains a vital goal for future work.</p>
        <p>As shown in <bold>Table 4</bold>, the majority of existing studies rely on one-way sequential coupling approaches, where thermal effects are applied as external loads in structural analysis. While this approach captures global responses such as thermal bowing, it neglects feedback mechanisms between mechanical damage and heat transfer. Furthermore, significant variations in thermal loading conditions and modeling assumptions contribute to inconsistencies in predicted behavior across studies.</p>
        <p><bold>Table 4</bold>. Summarizes the key characteristics of existing coupled thermo-mechanical studies on CSP systems, including modeling approaches, considered thermal and mechanical effects, and associated limitations.</p>
        <table-wrap id="tbl4">
          <label>Table 4</label>
          <table>
            <tbody>
              <tr>
                <td>
                  <bold>Ref</bold>
                </td>
                <td>
                  <bold>Modeling</bold>
                  <bold>type</bold>
                </td>
                <td>
                  <bold>Thermal</bold>
                  <bold>effect considered</bold>
                </td>
                <td>
                  <bold>Mechanical</bold>
                  <bold>effect considered</bold>
                </td>
                <td>
                  <bold>Limitation</bold>
                </td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B10">10</xref>
                  ]
                </td>
                <td>One-way sequential (SAP2000)</td>
                <td>Uniform temperature differential (ΔT) between wythes; thermal strain generation</td>
                <td>Thermal bowing; axial and moment forces; inter-wythe slip; connector forces</td>
                <td>Linear elastic materials; no cracking, creep, or shrinkage; accuracy decreases for high connector stiffness</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B1">1</xref>
                  ]
                </td>
                <td>One-way sequential (ANSYS)</td>
                <td>Constant surface temperatures (23˚C inside, −50˚C to +60˚C outside); thermal strain</td>
                <td>Bowing; internal stresses; cracking at ΔT ≤ −7˚C; connector stresses at panel ends</td>
                <td>One-way coupling; steady-state only; no temperature-dependent properties</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B2">2</xref>
                  ]
                </td>
                <td>One-way sequential, transient (ANSYS)</td>
                <td>Time-varying surface temperatures (heating/cooling profiles); transient heat transfer</td>
                <td>Bowing (129% increase from 0% to 85% composite action); cracking at ΔT ≤ −40˚C; combined windthermal effects</td>
                <td>Underestimates bowing (–21% to −10% error); no temperature-dependent properties; slip error up to −33%</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B18">18</xref>
                  ]
                </td>
                <td>One-way sequential, fire (custom code)</td>
                <td>ISO-834 fire on one side; conduction, convection, radiation; temperature-dependent material degradation</td>
                <td>Thermal bowing; slip; progressive connector rupture; global buckling; eccentric load effects</td>
                <td>1D smeared connectors; no spalling feedback to thermal model; computationally intensive</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B31">31</xref>
                  ]
                </td>
                <td>Experimental only (fire)</td>
                <td>One-side ISO-834 fire exposure; temperature measurement through thickness</td>
                <td>Initial thermal expansion; compression deformation; deflection reversal; local buckling of steel plate</td>
                <td>No numerical model; purely experimental; no coupled simulation</td>
              </tr>
              <tr>
                <td>
                  [
                  <xref ref-type="bibr" rid="B47">47</xref>
                  ]
                </td>
                <td>One-way sequential (Abaqus) - shrinkage as equivalent thermal strain</td>
                <td>Shrinkage strain applied via thermal strain capability (CTE set to zero for non-concrete materials)</td>
                <td>Time-dependent tensile stress development; cracking moment reduction; effect of reinforcement ratio</td>
                <td>Linear viscoelastic (no explicit cracking); shrinkage profile may not be universal; assumes perfect bond</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
    </sec>
    <sec id="sec5">
      <title>5. Durability, Service Life, and Environmental Interactions</title>
      <sec id="sec5dot1">
        <title>5.1. Accelerated Ageing and Connector Durability</title>
        <p>The sustainability of the CSPs largely depends on the durability of shear connectors, especially FRP and hybrid connectors, which can be affected adversely by high alkalinity, humidity, and thermal cycles. Accelerated aging tests offer important information for predicting the lifespan, but variations in testing methods reduce their applicability. Xue <italic>et al</italic>. [<xref ref-type="bibr" rid="B46">46</xref>] exposed GFRP connectors to an alkaline solution (pH 12.6 - 13) between 40˚C to 80˚C, for a maximum period of 183 days. Following this test, tensile strength and compressive strength were observed to decrease by 38.9% and 40.2%, respectively, due to hydrolytic effects and debonding of the matrix from the fibers. Using the Arrhenius equation, it was predicted that these connectors will last 50 years in moderate climates; however, this projection is based on the assumption that the rate of degradation stays constant throughout. Hybrid connectors using a combination of materials such as stainless steel reinforced with GFRP have been suggested to offer a compromise between strength and resistance to corrosion. According to Zhao <italic>et al</italic>. [<xref ref-type="bibr" rid="B39">39</xref>], delamination at the interface of steel and GFRP is the primary mode of failure during accelerated aging, but through proper design considerations like overlapping layups, the interfacial stresses could be minimized. Nevertheless, there has not been any direct comparison of the behavior of hybrid connectors with either all-FRP or all-steel connectors under similar aging conditions. Geometry also affects durability, with Fahmy <italic>et al</italic>. [<xref ref-type="bibr" rid="B41">41</xref>] indicating that CFRP tie connectors retained 85% - 90%, whereas BFRP tie connectors retained 60% - 70% of their shear capacities after undergoing alkaline aging. The former type outperformed the latter in an X-shape configuration as opposed to a Z-shape one because of the uniform stress distribution. In addition, O’Hegarty <italic>et al</italic>. [<xref ref-type="bibr" rid="B21">21</xref>] showed that cyclic wetting leads to progressive debonding of the insulation-concrete interface, irrespective of the material used for connecting the panels. Finally, Sah <italic>et al</italic>. [<xref ref-type="bibr" rid="B22">22</xref>] established that tension pre-conditioning results in stiff connectors, while straight one’s experience slip and stiffening degradation.</p>
        <p>A vital deficiency is evident: All current accelerated ageing tests have been conducted by examining hazards individually such as alkaline exposure, moisture or temperature effects. No experiment has ever conducted ageing in a multi-hazard condition, for example, alkaline-thermal-mechanical loadings, or verified accelerated test results based on actual exposure in the field.</p>
      </sec>
      <sec id="sec5dot2">
        <title>5.2. Hygrothermal Interactions, Moisture Ingress, and Freeze‑Thaw Effects</title>
        <p>The effects of hygrothermal loading, including thermal cycling, moisture diffusion, and freeze-thaw, control the durability of PCSPs. They have synergistic effects; thermal stress causes cracking; cracking serves as a path for moisture diffusion; and further cycles of freeze-thaw deteriorate the panels. Thermal bowing is one of the main factors contributing to service-level failure. As stated in Arevalo and Tomlinson [<xref ref-type="bibr" rid="B12">12</xref>], full-scale PCSP specimens with high-stiffness GFRP connectors were tested at a temperature difference of 20˚C - 30˚C. Thermal deformation accounted for 63% of the maximum allowable deflection L/250. High connector stiffness caused bowing to increase by an additional 16%. Moreover, thermal stresses in the panels exceeded the proportional limit of the concrete; thus, fatigue damage was possible. Ingress of moisture depends on the interaction at the insulation-concrete interface. Studies conducted by Egbon &amp; Tomlinson [<xref ref-type="bibr" rid="B44">44</xref>] reveal that the presence of a shear stress debonds the unnotched XPS insulations, allowing moisture ingress through continuous channels formed. Rectangular notching enhanced the mechanical lock between the concrete and insulation and increased the peak load by 50%, while limiting moisture ingress. Likewise, Bida <italic>et al</italic>. [<xref ref-type="bibr" rid="B16">16</xref>] demonstrate how staggered steel connectors can increase the effective length of heat and moisture paths by 127.5% when compared to connectors, hence minimizing heat losses and moisture ingress. Freeze-thaw cycles further enhance this behavior since moisture in the cracks and at the interfaces causes expansion during freezing leading to cracking of wythes, debonding of connectors, and weakening of the connectors themselves. Preliminary data indicate that GFRP connectors can lose up to 30% of their shear strength in freeze-thaw cycles [<xref ref-type="bibr" rid="B12">12</xref>][<xref ref-type="bibr" rid="B44">44</xref>]; however, the exact mechanism involved remains unknown.</p>
        <p>Despite the success of mitigation techniques, more validation is required for this technology in a scenario of exposure to multiple effects. Li <italic>et al</italic>. [<xref ref-type="bibr" rid="B7">7</xref>] proposed a double-layered insulation technique using AAC and PU to achieve an insulation value of 0.241 W/m<sup>2</sup>·K. The AAC serves as a protective layer, which protects the stainless-steel connectors from harsh thermal shocks. However, this combination has not yet been evaluated with thermal, moisture exposure, and mechanical loading effects.</p>
      </sec>
      <sec id="sec5dot3">
        <title>5.3. Long‑Term Mechanical Degradation: Creep, Shrinkage, Sustained Loads, and Fatigue</title>
        <p>Long-term mechanical degradation in PCSPs happens because of creep under steady loads, different shrinkage between the layers, and buildup of fatigue damage. Creep in concrete layers and the viscoelastic relaxation of insulation cause progressive slip and decrease the composite action. Choi <italic>et al</italic>. [<xref ref-type="bibr" rid="B23">23</xref>] found that connector geometry and creep compliance affect slip, and Pan <italic>et al</italic>. [<xref ref-type="bibr" rid="B4">4</xref>] noticed that C-shaped GFRP connectors have faster nonlinear slip thanks to resin creep. Sylaj <italic>et al</italic>. [<xref ref-type="bibr" rid="B33">33</xref>] added that using UHHPFC cuts down creep-related slip, yet there’s still some residual deformation that’s a worry after 50 years. Ke <italic>et al</italic>. [<xref ref-type="bibr" rid="B38">38</xref>] mentioned that ultra-stiff UHPC-filled stainless steel pipes lessen the difference in displacement but create continuous interface stresses that might start fatigue cracks. Besides, the differential shrinkage causes bowing between inner and outer layers, which ends up at 60% - 75% of the thermal bowing [<xref ref-type="bibr" rid="B47">47</xref>], creating lasting tensile stress that could lead to early cracking. Using lightweight aggregates cuts down shrinkage but drops stiffness, making the structure less able to withstand wind and impacts [<xref ref-type="bibr" rid="B5">5</xref>][<xref ref-type="bibr" rid="B9">9</xref>].</p>
        <p>Combined sustained gravity, wind, and thermal loads cause complex multi-axial stresses that short-term tests don’t catch well. Arevalo and Tomlinson [<xref ref-type="bibr" rid="B12">12</xref>] said that peak connector forces were higher than expected because of geometric nonlinearity, which could start fatigue cracks. Plus, Jawdhari <italic>et al</italic>. [<xref ref-type="bibr" rid="B2">2</xref>] discovered that cyclic thermal changes can reverse stress, adding up over thousands of cycles. There aren’t many fatigue studies out there. For example, Bian and Liu [<xref ref-type="bibr" rid="B20">20</xref>] noted that FRP connectors kept just 40% - 55% of their initial strength after 10<sup>7</sup> cycles and broke in two stages. Similarly, Chen <italic>et al</italic>. [<xref ref-type="bibr" rid="B30">30</xref>] saw that failure moved from concrete bearing to fiber-matrix debonding in fatigue. With steel connectors, how well they’re welded decides their fatigue life [<xref ref-type="bibr" rid="B11">11</xref>]. The coupling between creep and thermal bowing remains unmodelled; Pozo‑Lora [<xref ref-type="bibr" rid="B10">10</xref>] noted that long‑term slip reduces composite action, increasing curvature beyond code limits. Seismic resilience after long‑term degradation is unknown [<xref ref-type="bibr" rid="B48">48</xref>].</p>
      </sec>
      <sec id="sec5dot4">
        <title>5.4. Knowledge Gaps and Research Needs</title>
        <p>Literature shows seven major gaps in PCSP durability. Firstly, there’s no multi-hazard assessment; studies don’t look at all hazards at once like alkaline, thermal, moisture, and mechanical loading [<xref ref-type="bibr" rid="B46">46</xref>][<xref ref-type="bibr" rid="B44">44</xref>]. Next, long-term creep and fatigue models are missing—S-N curves and creep coefficients for common connectors, like GFRP, CFRP, and hybrid ones, aren’t around [<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B23">23</xref>][<xref ref-type="bibr" rid="B33">33</xref>].</p>
        <p>Then, differential shrinkage, which can cause bowing similar to thermal effects, isn’t considered in design loading cases [<xref ref-type="bibr" rid="B47">47</xref>]. Also, there’s a lag in providing durability data for new connectors compared to the progress in structural testing [<xref ref-type="bibr" rid="B4">4</xref>][<xref ref-type="bibr" rid="B8">8</xref>][<xref ref-type="bibr" rid="B19">19</xref>][<xref ref-type="bibr" rid="B22">22</xref>][<xref ref-type="bibr" rid="B32">32</xref>][<xref ref-type="bibr" rid="B38">38</xref>]-[<xref ref-type="bibr" rid="B40">40</xref>]. Plus, we don’t have any coupled degradation-thermal-structural models that consider time-dependent connector stiffness loss [<xref ref-type="bibr" rid="B1">1</xref>][<xref ref-type="bibr" rid="B2">2</xref>][<xref ref-type="bibr" rid="B10">10</xref>][<xref ref-type="bibr" rid="B12">12</xref>][<xref ref-type="bibr" rid="B17">17</xref>][<xref ref-type="bibr" rid="B24">24</xref>].</p>
        <p>Post-fire performance and how long PCSPs last after fires are wide unknowns too [<xref ref-type="bibr" rid="B18">18</xref>][<xref ref-type="bibr" rid="B31">31</xref>][<xref ref-type="bibr" rid="B34">34</xref>]. Lastly, there’s not a single bit of field validation data from long-term installed.</p>
        <p>To fix these issues, we need standardized test methods that mimic real-world wear and tear. These must include how materials stretch, weaken, and change over time because of heat and drying. Also, we should tweak the accelerated ageing method by Xue <italic>et al</italic>. [<xref ref-type="bibr" rid="B46">46</xref>] for newer connector types. Tests after fires need to check how much life a connector has left and if damage sped up the aging process. Plus, we must install sensors to track long-term problems like warping, force changes, moisture, and cracks. This lets us check our speedy tests and create safe, lasting designs for post-tensioned structures.</p>
      </sec>
    </sec>
    <sec id="sec6">
      <title>6. Conclusion</title>
      <p>This review has synthesized major developments in the thermal and mechanical performance of concrete sandwich panels (CSPs) published between 2018 and 2025. The widespread adoption of low‑conductivity fiber‑reinforced polymer (FRP) connectors represent a significant step toward mitigating thermal bridging, while innovative connector geometries including staggered layouts, C‑shaped profiles, and hybrid systems have improved both shear capacity and composite action. Advances in insulation materials, such as vacuum insulation panels (VIPs) and phase‑change material (PCM) composites, along with sustainable alternatives like bio‑based foams and crumb rubber cores, point toward a future where CSPs can contribute more effectively to sustainable building envelopes.</p>
      <p>A fundamental and persistent conflict remains: stiff connectors that provide high composite action and mechanical strength inevitably increase thermal bowing and connector stresses under thermal gradients. This trade‑off between structural integrity and thermal efficiency explains why many practical designs intentionally target a balanced, partial composite action.</p>
      <p>Looking ahead, the route to next‑generation CSPs requires moving beyond the current, largely decoupled analyses of thermal and mechanical behavior. Critical gaps include the scarcity of full‑scale testing under combined environmental and mechanical loads, the absence of true two‑way hygro‑thermo‑mechanical models that capture damage feedback and temperature‑dependent degradation, and the lack of long‑term durability data for FRP connectors under real climatic conditions, including freeze‑thaw cycles, moisture ingress, and aging. Future efforts must focus on developing and experimentally validating integrated multi‑physics models, standardizing reporting metrics for composite action and thermal bridging, and expanding research to hybrid and sustainable connector materials. Only through such holistic approaches can the full potential of CSPs as durable, resilient, and energy‑efficient building systems be realized for 21<sup>st</sup>‑century construction demands.</p>
      <p>The CSP’s lifespan faces serious risks due to environmental interactions involving multiple hazards that have not been adequately studied. Aging results in deterioration, but there has been no research into how aging affects CSPs under loading conditions. In addition, important processes like creep, shrinkage, and fatigue have been consistently ignored by many modeling studies. There is an urgent need to come up with standard methods for aging assembled CSPs and using coupled hygro-thermo-mechano-chemical models.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Jawdhari, A. and Fam, A. (2020) Thermal-Structural Analysis and Thermal Bowing of Double Wythe UHPC Insulated Walls. <italic>Energy and Buildings</italic>, 223, Article 110012.</mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Jawdhari, A.</string-name>
              <string-name>Fam, A.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Thermal-Structural Analysis and Thermal Bowing of Double Wythe UHPC Insulated Walls</article-title>
            <source>Energy and Buildings</source>
            <volume>223</volume>
            <elocation-id>110012</elocation-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B2">
        <label>2.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Jawdhari, A., Fam, A. and Kadhim, M.M.A. (2022) Thermal Bowing of Reinforced Concrete Sandwich Panels Using Time-Domain Coupled-Field Finite Element Analysis. <italic>Engineering Structures</italic>, 252, Article 113592. https://doi.org/10.1016/j.engstruct.2021.113592 <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.113592</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2021.113592">https://doi.org/10.1016/j.engstruct.2021.113592</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Jawdhari, A.</string-name>
              <string-name>Fam, A.</string-name>
              <string-name>Kadhim, M.M.A.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Thermal Bowing of Reinforced Concrete Sandwich Panels Using Time-Domain Coupled-Field Finite Element Analysis</article-title>
            <source>Engineering Structures</source>
            <volume>252</volume>
            <elocation-id>113592</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.113592</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B3">
        <label>3.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Upasiri, I.R., Konthesigha, K.M.C., Nanayakkara, S.M.A., Poologanathan, K., Gatheeshgar, P. and Nuwanthika, D. (2021) Finite Element Analysis of Lightweight Composite Sandwich Panels Exposed to Fire. <italic>Journal of Building Engineering</italic>, 40, Article 102329. https://doi.org/10.1016/j.jobe.2021.102329 <pub-id pub-id-type="doi">10.1016/j.jobe.2021.102329</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2021.102329">https://doi.org/10.1016/j.jobe.2021.102329</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Upasiri, I.R.</string-name>
              <string-name>Konthesigha, K.M.C.</string-name>
              <string-name>Nanayakkara, S.M.A.</string-name>
              <string-name>Poologanathan, K.</string-name>
              <string-name>Gatheeshgar, P.</string-name>
              <string-name>Nuwanthika, D.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Finite Element Analysis of Lightweight Composite Sandwich Panels Exposed to Fire</article-title>
            <source>Journal of Building Engineering</source>
            <volume>40</volume>
            <elocation-id>102329</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2021.102329</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B4">
        <label>4.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Pan, P., He, Z., Wang, H. and Kang, Y. (2022) Experimental Investigation of C-Shaped Glass-Fiber-Reinforced Polymer Connectors for Sandwich Insulation Wall Panels. <italic>Engineering Structures</italic>, 250, Article 113462. https://doi.org/10.1016/j.engstruct.2021.113462 <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.113462</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2021.113462">https://doi.org/10.1016/j.engstruct.2021.113462</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Pan, P.</string-name>
              <string-name>He, Z.</string-name>
              <string-name>Wang, H.</string-name>
              <string-name>Kang, Y.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Experimental Investigation of C-Shaped Glass-Fiber-Reinforced Polymer Connectors for Sandwich Insulation Wall Panels</article-title>
            <source>Engineering Structures</source>
            <volume>250</volume>
            <elocation-id>113462</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.113462</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B5">
        <label>5.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Yang, Y., Ge, Z., Li, Y. and Fan, X. (2022) Investigation on Mechanical Properties of Lightweight Sandwich Exterior Wall with Thermal Blocking Shear Connector. <italic>Structures</italic>, 46, 421-432. https://doi.org/10.1016/j.istruc.2022.10.064 <pub-id pub-id-type="doi">10.1016/j.istruc.2022.10.064</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2022.10.064">https://doi.org/10.1016/j.istruc.2022.10.064</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Yang, Y.</string-name>
              <string-name>Ge, Z.</string-name>
              <string-name>Li, Y.</string-name>
              <string-name>Fan, X.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Investigation on Mechanical Properties of Lightweight Sandwich Exterior Wall with Thermal Blocking Shear Connector</article-title>
            <source>Structures</source>
            <volume>46</volume>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2022.10.064</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B6">
        <label>6.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">O’Hegarty, R., Kinnane, O., Grimes, M., Newell, J., Clifford, M. and West, R. (2021) Development of Thin Precast Concrete Sandwich Panels: Challenges and Outcomes. <italic>Construction and Building Materials</italic>, 267, Article 120981. https://doi.org/10.1016/j.conbuildmat.2020.120981 <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2020.120981</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.conbuildmat.2020.120981">https://doi.org/10.1016/j.conbuildmat.2020.120981</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Hegarty, R.</string-name>
              <string-name>Kinnane, O.</string-name>
              <string-name>Grimes, M.</string-name>
              <string-name>Newell, J.</string-name>
              <string-name>Clifford, M.</string-name>
              <string-name>West, R.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Development of Thin Precast Concrete Sandwich Panels: Challenges and Outcomes</article-title>
            <source>Construction and Building Materials</source>
            <volume>267</volume>
            <elocation-id>120981</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2020.120981</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B7">
        <label>7.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Li, G., Li, X., Fang, C. and Liu, R. (2025) Thermal Performance of Precast Concrete Sandwich Walls with a Double-Layer Insulation System. <italic>Construction and Building Materials</italic>, 472, Article 140785. https://doi.org/10.1016/j.conbuildmat.2025.140785 <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2025.140785</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.conbuildmat.2025.140785">https://doi.org/10.1016/j.conbuildmat.2025.140785</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Li, G.</string-name>
              <string-name>Li, X.</string-name>
              <string-name>Fang, C.</string-name>
              <string-name>Liu, R.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Thermal Performance of Precast Concrete Sandwich Walls with a Double-Layer Insulation System</article-title>
            <source>Construction and Building Materials</source>
            <volume>472</volume>
            <elocation-id>140785</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2025.140785</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B8">
        <label>8.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">An, Y., Huang, W., Quan, W., Guo, Q., Miao, X. and Wang, M. (2025) Study on the Shear Performance of GFRP Ultra-Long Two-Way Connectors for Precast Concrete Sandwich Walls. <italic>Structures</italic>, 71, Article 107962. https://doi.org/10.1016/j.istruc.2024.107962 <pub-id pub-id-type="doi">10.1016/j.istruc.2024.107962</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2024.107962">https://doi.org/10.1016/j.istruc.2024.107962</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>An, Y.</string-name>
              <string-name>Huang, W.</string-name>
              <string-name>Quan, W.</string-name>
              <string-name>Guo, Q.</string-name>
              <string-name>Miao, X.</string-name>
              <string-name>Wang, M.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Study on the Shear Performance of GFRP Ultra-Long Two-Way Connectors for Precast Concrete Sandwich Walls</article-title>
            <source>Structures</source>
            <volume>71</volume>
            <elocation-id>107962</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2024.107962</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B9">
        <label>9.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Chen, Y., Kang, C., Wu, Y. and Qian, Z. (2022) Bending Performance of Precast Ceramsite-Concrete-Insulated Sandwich Panel with Stainless Steel Shear Connectors. <italic>Buildings</italic>, 12, Article 1640. https://doi.org/10.3390/buildings12101640 <pub-id pub-id-type="doi">10.3390/buildings12101640</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/buildings12101640">https://doi.org/10.3390/buildings12101640</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Chen, Y.</string-name>
              <string-name>Kang, C.</string-name>
              <string-name>Wu, Y.</string-name>
              <string-name>Qian, Z.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Bending Performance of Precast Ceramsite-Concrete-Insulated Sandwich Panel with Stainless Steel Shear Connectors</article-title>
            <source>Buildings</source>
            <volume>12</volume>
            <elocation-id>1640</elocation-id>
            <pub-id pub-id-type="doi">10.3390/buildings12101640</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B10">
        <label>10.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Pozo-Lora, F. and Maguire, M. (2020) Thermal Bowing of Concrete Sandwich Panels with Flexible Shear Connectors. <italic>Journal of Building Engineering</italic>, 29, Article 101124. https://doi.org/10.1016/j.jobe.2019.101124 <pub-id pub-id-type="doi">10.1016/j.jobe.2019.101124</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2019.101124">https://doi.org/10.1016/j.jobe.2019.101124</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Pozo-Lora, F.</string-name>
              <string-name>Maguire, M.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Thermal Bowing of Concrete Sandwich Panels with Flexible Shear Connectors</article-title>
            <source>Journal of Building Engineering</source>
            <volume>29</volume>
            <elocation-id>101124</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2019.101124</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B11">
        <label>11.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Kinnane, O., West, R. and Hegarty, R.O. (2020) Structural Shear Performance of Insulated Precast Concrete Sandwich Panels with Steel Plate Connectors. <italic>Engineering Structures</italic>, 215, Article 110691. https://doi.org/10.1016/j.engstruct.2020.110691 <pub-id pub-id-type="doi">10.1016/j.engstruct.2020.110691</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2020.110691">https://doi.org/10.1016/j.engstruct.2020.110691</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Kinnane, O.</string-name>
              <string-name>West, R.</string-name>
              <string-name>Hegarty, R.O.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Structural Shear Performance of Insulated Precast Concrete Sandwich Panels with Steel Plate Connectors</article-title>
            <source>Engineering Structures</source>
            <volume>215</volume>
            <elocation-id>110691</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2020.110691</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B12">
        <label>12.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Arevalo, S. and Tomlinson, D. (2020) Experimental Thermal Bowing Response of Precast Concrete Insulated Wall Panels with Stiff Shear Connectors and Simple Supports. <italic>Journal of Building Engineering</italic>, 30, Article 101319. https://doi.org/10.1016/j.jobe.2020.101319 <pub-id pub-id-type="doi">10.1016/j.jobe.2020.101319</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2020.101319">https://doi.org/10.1016/j.jobe.2020.101319</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Arevalo, S.</string-name>
              <string-name>Tomlinson, D.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Experimental Thermal Bowing Response of Precast Concrete Insulated Wall Panels with Stiff Shear Connectors and Simple Supports</article-title>
            <source>Journal of Building Engineering</source>
            <volume>30</volume>
            <elocation-id>101319</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2020.101319</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B13">
        <label>13.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Tawil, H., Tan, C.G., Sulong, N.H.R., Nazri, F.M., Sherif, M.M. and El-Shafie, A. (2022) Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review. <italic>Buildings</italic>, 12, Article 1429. https://doi.org/10.3390/buildings12091429 <pub-id pub-id-type="doi">10.3390/buildings12091429</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/buildings12091429">https://doi.org/10.3390/buildings12091429</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Tawil, H.</string-name>
              <string-name>Tan, C.G.</string-name>
              <string-name>Sulong, N.H.R.</string-name>
              <string-name>Nazri, F.M.</string-name>
              <string-name>Sherif, M.M.</string-name>
              <string-name>El-Shafie, A.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review</article-title>
            <source>Buildings</source>
            <volume>12</volume>
            <elocation-id>1429</elocation-id>
            <pub-id pub-id-type="doi">10.3390/buildings12091429</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B14">
        <label>14.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Sah, T.P., Lacey, A.W., Hao, H. and Chen, W. (2024) Prefabricated Concrete Sandwich and Other Lightweight Wall Panels for Sustainable Building Construction: State-of-the-Art Review. <italic>Journal of Building Engineering</italic>, 89, Article 109391. https://doi.org/10.1016/j.jobe.2024.109391 <pub-id pub-id-type="doi">10.1016/j.jobe.2024.109391</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2024.109391">https://doi.org/10.1016/j.jobe.2024.109391</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Sah, T.P.</string-name>
              <string-name>Lacey, A.W.</string-name>
              <string-name>Hao, H.</string-name>
              <string-name>Chen, W.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Prefabricated Concrete Sandwich and Other Lightweight Wall Panels for Sustainable Building Construction: State-of-the-Art Review</article-title>
            <source>Journal of Building Engineering</source>
            <volume>89</volume>
            <elocation-id>109391</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2024.109391</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B15">
        <label>15.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Pozo-Lora, F.F., Sorensen, T.J., Al-Rubaye, S. and Maguire, M. (2025) State-of-the-Art and Practice Review in Concrete Sandwich Wall Panels: Materials, Design, and Construction Methods. <italic>Sustainability</italic>, 17, Article 3704. https://doi.org/10.3390/su17083704 <pub-id pub-id-type="doi">10.3390/su17083704</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/su17083704">https://doi.org/10.3390/su17083704</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Pozo-Lora, F.F.</string-name>
              <string-name>Sorensen, T.J.</string-name>
              <string-name>Al-Rubaye, S.</string-name>
              <string-name>Maguire, M.</string-name>
              <string-name>Materials, D</string-name>
            </person-group>
            <year>2025</year>
            <article-title>State-of-the-Art and Practice Review in Concrete Sandwich Wall Panels: Materials, Design, and Construction Methods</article-title>
            <source>Sustainability</source>
            <volume>17</volume>
            <elocation-id>3704</elocation-id>
            <pub-id pub-id-type="doi">10.3390/su17083704</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B16">
        <label>16.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Bida, S.M., Abdul Aziz, F.N.A., Jaafar, M.S., Hejazi, F. and Abu Bakar, N. (2021) Thermal Resistance of Insulated Precast Concrete Sandwich Panels. <italic>International Journal of Concrete Structures and Materials</italic>, 15, Article No. 41. https://doi.org/10.1186/s40069-021-00477-6 <pub-id pub-id-type="doi">10.1186/s40069-021-00477-6</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s40069-021-00477-6">https://doi.org/10.1186/s40069-021-00477-6</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Bida, S.M.</string-name>
              <string-name>Aziz, F.N.A.</string-name>
              <string-name>Jaafar, M.S.</string-name>
              <string-name>Hejazi, F.</string-name>
              <string-name>Bakar, N.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Thermal Resistance of Insulated Precast Concrete Sandwich Panels</article-title>
            <source>International Journal of Concrete Structures and Materials</source>
            <volume>15</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1186/s40069-021-00477-6</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B17">
        <label>17.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Yu, S., Liu, Y., Wang, D., Ma, C. and Liu, J. (2022) Theoretical, Experimental and Numerical Study on the Influence of Connectors on the Thermal Performance of Precast Concrete Sandwich Walls. <italic>Journal of Building Engineering</italic>, 57, Article 104886. https://doi.org/10.1016/j.jobe.2022.104886 <pub-id pub-id-type="doi">10.1016/j.jobe.2022.104886</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2022.104886">https://doi.org/10.1016/j.jobe.2022.104886</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Yu, S.</string-name>
              <string-name>Liu, Y.</string-name>
              <string-name>Wang, D.</string-name>
              <string-name>Ma, C.</string-name>
              <string-name>Liu, J.</string-name>
              <string-name>Theoretical, E</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Theoretical, Experimental and Numerical Study on the Influence of Connectors on the Thermal Performance of Precast Concrete Sandwich Walls</article-title>
            <source>Journal of Building Engineering</source>
            <volume>57</volume>
            <elocation-id>104886</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2022.104886</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B18">
        <label>18.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Chen, J., Hamed, E. and Gilbert, R.I. (2021) Structural Performance of Concrete Sandwich Panels under Fire. <italic>Fire Safety Journal</italic>, 121, Article 103293. https://doi.org/10.1016/j.firesaf.2021.103293 <pub-id pub-id-type="doi">10.1016/j.firesaf.2021.103293</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.firesaf.2021.103293">https://doi.org/10.1016/j.firesaf.2021.103293</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Chen, J.</string-name>
              <string-name>Hamed, E.</string-name>
              <string-name>Gilbert, R.I.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Structural Performance of Concrete Sandwich Panels under Fire</article-title>
            <source>Fire Safety Journal</source>
            <volume>121</volume>
            <elocation-id>103293</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.firesaf.2021.103293</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B19">
        <label>19.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Huang, J., Jiang, Q., Chong, X., Ye, X. and Wang, D. (2020) Experimental Study on Precast Concrete Sandwich Panel with Cross-Shaped GFRP Connectors. <italic>Magazine of Concrete Research</italic>, 72, 149-162. https://doi.org/10.1680/jmacr.18.00258 <pub-id pub-id-type="doi">10.1680/jmacr.18.00258</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1680/jmacr.18.00258">https://doi.org/10.1680/jmacr.18.00258</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Huang, J.</string-name>
              <string-name>Jiang, Q.</string-name>
              <string-name>Chong, X.</string-name>
              <string-name>Ye, X.</string-name>
              <string-name>Wang, D.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Experimental Study on Precast Concrete Sandwich Panel with Cross-Shaped GFRP Connectors</article-title>
            <source>Magazine of Concrete Research</source>
            <volume>72</volume>
            <pub-id pub-id-type="doi">10.1680/jmacr.18.00258</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B20">
        <label>20.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Bian, Y. and Liu, Y. (2024) In-Plane Shear Performance and Damage Evolution of FRP Connectors for Composite Sandwich Panels. <italic>Engineering Structures</italic>, 314, Article 118326. https://doi.org/10.1016/j.engstruct.2024.118326 <pub-id pub-id-type="doi">10.1016/j.engstruct.2024.118326</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2024.118326">https://doi.org/10.1016/j.engstruct.2024.118326</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Bian, Y.</string-name>
              <string-name>Liu, Y.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>In-Plane Shear Performance and Damage Evolution of FRP Connectors for Composite Sandwich Panels</article-title>
            <source>Engineering Structures</source>
            <volume>314</volume>
            <elocation-id>118326</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2024.118326</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B21">
        <label>21.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">O′Hegarty, R., West, R., Reilly, A. and Kinnane, O. (2019) Composite Behaviour of Fibre-Reinforced Concrete Sandwich Panels with FRP Shear Connectors. <italic>Engineering Structures</italic>, 198, Article 109475. https://doi.org/10.1016/j.engstruct.2019.109475 <pub-id pub-id-type="doi">10.1016/j.engstruct.2019.109475</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2019.109475">https://doi.org/10.1016/j.engstruct.2019.109475</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Hegarty, R.</string-name>
              <string-name>West, R.</string-name>
              <string-name>Reilly, A.</string-name>
              <string-name>Kinnane, O.</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Composite Behaviour of Fibre-Reinforced Concrete Sandwich Panels with FRP Shear Connectors</article-title>
            <source>Engineering Structures</source>
            <volume>198</volume>
            <elocation-id>109475</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2019.109475</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B22">
        <label>22.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Sah, T.P., Lacey, A.W., Hao, H., Manalo, A. and Chen, W. (2025) Flexural Performance of Composite Prefabricated Concrete Sandwich Panels with Pultruded Square GFRP Tubular Shear Connectors. <italic>Structures</italic>, 78, Article 109287. https://doi.org/10.1016/j.istruc.2025.109287 <pub-id pub-id-type="doi">10.1016/j.istruc.2025.109287</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2025.109287">https://doi.org/10.1016/j.istruc.2025.109287</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Sah, T.P.</string-name>
              <string-name>Lacey, A.W.</string-name>
              <string-name>Hao, H.</string-name>
              <string-name>Manalo, A.</string-name>
              <string-name>Chen, W.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Flexural Performance of Composite Prefabricated Concrete Sandwich Panels with Pultruded Square GFRP Tubular Shear Connectors</article-title>
            <source>Structures</source>
            <volume>78</volume>
            <elocation-id>109287</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2025.109287</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B23">
        <label>23.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Choi, W., Jang, S. and Yun, H. (2019) Design Properties of Insulated Precast Concrete Sandwich Panels with Composite Shear Connectors. <italic>Composites Part B</italic>: <italic>Engineering</italic>, 157, 36-42. https://doi.org/10.1016/j.compositesb.2018.08.081 <pub-id pub-id-type="doi">10.1016/j.compositesb.2018.08.081</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.compositesb.2018.08.081">https://doi.org/10.1016/j.compositesb.2018.08.081</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Choi, W.</string-name>
              <string-name>Jang, S.</string-name>
              <string-name>Yun, H.</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Design Properties of Insulated Precast Concrete Sandwich Panels with Composite Shear Connectors</article-title>
            <source>Composites Part B: Engineering</source>
            <volume>157</volume>
            <pub-id pub-id-type="doi">10.1016/j.compositesb.2018.08.081</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B24">
        <label>24.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Yang, Q., Wu, X., Li, J. and Wang, M. (2025) Optimization Study of Thermal Defects in Prefabricated Rural Residential Buildings Based on Fluent. <italic>Case Studies in Thermal Engineering</italic>, 75, Article 107120. https://doi.org/10.1016/j.csite.2025.107120 <pub-id pub-id-type="doi">10.1016/j.csite.2025.107120</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.csite.2025.107120">https://doi.org/10.1016/j.csite.2025.107120</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Yang, Q.</string-name>
              <string-name>Wu, X.</string-name>
              <string-name>Li, J.</string-name>
              <string-name>Wang, M.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Optimization Study of Thermal Defects in Prefabricated Rural Residential Buildings Based on Fluent</article-title>
            <source>Case Studies in Thermal Engineering</source>
            <volume>75</volume>
            <elocation-id>107120</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.csite.2025.107120</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B25">
        <label>25.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Zhang, Z., Hou, Y. and Wang, Y. (2025) Research on Thermal Performance of Polypropylene Fiber-Reinforced Concrete Wall Panels. <italic>Buildings</italic>, 15, Article 2199. https://doi.org/10.3390/buildings15132199 <pub-id pub-id-type="doi">10.3390/buildings15132199</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/buildings15132199">https://doi.org/10.3390/buildings15132199</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Zhang, Z.</string-name>
              <string-name>Hou, Y.</string-name>
              <string-name>Wang, Y.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Research on Thermal Performance of Polypropylene Fiber-Reinforced Concrete Wall Panels</article-title>
            <source>Buildings</source>
            <volume>15</volume>
            <elocation-id>2199</elocation-id>
            <pub-id pub-id-type="doi">10.3390/buildings15132199</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B26">
        <label>26.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Hassan, A., Rashid, Y., Mourad, A.I., Ismail, N. and Laghari, M.S. (2019) Thermal and Structural Characterization of Geopolymer-Coated Polyurethane Foam—Phase Change Material Capsules/Geopolymer Concrete Composites. <italic>Materials</italic>, 12, Article 796. https://doi.org/10.3390/ma12050796 <pub-id pub-id-type="doi">10.3390/ma12050796</pub-id><pub-id pub-id-type="pmid">30866570</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/ma12050796">https://doi.org/10.3390/ma12050796</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Hassan, A.</string-name>
              <string-name>Rashid, Y.</string-name>
              <string-name>Mourad, A.I.</string-name>
              <string-name>Ismail, N.</string-name>
              <string-name>Laghari, M.S.</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Thermal and Structural Characterization of Geopolymer-Coated Polyurethane Foam—Phase Change Material Capsules/Geopolymer Concrete Composites</article-title>
            <source>Materials</source>
            <volume>12</volume>
            <elocation-id>796</elocation-id>
            <pub-id pub-id-type="doi">10.3390/ma12050796</pub-id>
            <pub-id pub-id-type="pmid">30866570</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B27">
        <label>27.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Martínez, B., Mercedes, L., Bernat-Maso, E. and Gil, L. (2025) Sustainable Reinforcement Strategy for Green Insulation Panels: Evaluation of Hemp Mesh Geometry and Natural Coatings. <italic>Journal of Building Engineering</italic>, 112, Article 113803. https://doi.org/10.1016/j.jobe.2025.113803 <pub-id pub-id-type="doi">10.1016/j.jobe.2025.113803</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2025.113803">https://doi.org/10.1016/j.jobe.2025.113803</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Mercedes, L.</string-name>
              <string-name>Bernat-Maso, E.</string-name>
              <string-name>Gil, L.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Sustainable Reinforcement Strategy for Green Insulation Panels: Evaluation of Hemp Mesh Geometry and Natural Coatings</article-title>
            <source>Journal of Building Engineering</source>
            <volume>112</volume>
            <elocation-id>113803</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2025.113803</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B28">
        <label>28.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Thangarasu, A. and Henderson, J.H. (2022) Thermal and Structural Behaviour of Sandwiched Reinforced Cement Concrete Wall Panels. <italic>Materials Science</italic>, 28, 506-518. https://doi.org/10.5755/j02.ms.30339 <pub-id pub-id-type="doi">10.5755/j02.ms.30339</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5755/j02.ms.30339">https://doi.org/10.5755/j02.ms.30339</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Thangarasu, A.</string-name>
              <string-name>Henderson, J.H.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Thermal and Structural Behaviour of Sandwiched Reinforced Cement Concrete Wall Panels</article-title>
            <source>Materials Science</source>
            <volume>28</volume>
            <pub-id pub-id-type="doi">10.5755/j02.ms.30339</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B29">
        <label>29.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Su, B., Zhang, T., Chen, S., Hao, J. and Zhang, R. (2022) Thermal Properties of Novel Sandwich Roof Panel Made of Basalt Fiber Reinforced Plastic Material. <italic>Journal of Building Engineering</italic>, 52, Article 104478. https://doi.org/10.1016/j.jobe.2022.104478 <pub-id pub-id-type="doi">10.1016/j.jobe.2022.104478</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2022.104478">https://doi.org/10.1016/j.jobe.2022.104478</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Su, B.</string-name>
              <string-name>Zhang, T.</string-name>
              <string-name>Chen, S.</string-name>
              <string-name>Hao, J.</string-name>
              <string-name>Zhang, R.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Thermal Properties of Novel Sandwich Roof Panel Made of Basalt Fiber Reinforced Plastic Material</article-title>
            <source>Journal of Building Engineering</source>
            <volume>52</volume>
            <elocation-id>104478</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2022.104478</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B30">
        <label>30.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Chen, D., Li, K., Yuan, Z., Cheng, B. and Kang, X. (2022) Shear Behavior of FRP Connectors in Precast Sandwich Insulation Wall Panels. <italic>Buildings</italic>, 12, Article 1095. https://doi.org/10.3390/buildings12081095 <pub-id pub-id-type="doi">10.3390/buildings12081095</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/buildings12081095">https://doi.org/10.3390/buildings12081095</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Chen, D.</string-name>
              <string-name>Li, K.</string-name>
              <string-name>Yuan, Z.</string-name>
              <string-name>Cheng, B.</string-name>
              <string-name>Kang, X.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Shear Behavior of FRP Connectors in Precast Sandwich Insulation Wall Panels</article-title>
            <source>Buildings</source>
            <volume>12</volume>
            <elocation-id>1095</elocation-id>
            <pub-id pub-id-type="doi">10.3390/buildings12081095</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B31">
        <label>31.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Du, E., Shu, G., Qin, L., Lai, B., Zhou, X. and Zhou, G. (2022) Experimental Investigation on Fire Resistance of Sandwich Composite Walls with Truss Connectors. <italic>Jour</italic><italic>nal of Constructional Steel Research</italic>, 188, Article 107052. https://doi.org/10.1016/j.jcsr.2021.107052 <pub-id pub-id-type="doi">10.1016/j.jcsr.2021.107052</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jcsr.2021.107052">https://doi.org/10.1016/j.jcsr.2021.107052</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Du, E.</string-name>
              <string-name>Shu, G.</string-name>
              <string-name>Qin, L.</string-name>
              <string-name>Lai, B.</string-name>
              <string-name>Zhou, X.</string-name>
              <string-name>Zhou, G.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Experimental Investigation on Fire Resistance of Sandwich Composite Walls with Truss Connectors</article-title>
            <source>Journal of Constructional Steel Research</source>
            <volume>188</volume>
            <elocation-id>107052</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jcsr.2021.107052</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B32">
        <label>32.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Tawil, H., Tan, C.G., Ramli Sulong, N.H., Nazri, F.M., Shamsudin, M.F. and Muhamad Bunnori, N. (2024) Optimization of Shear Resistance in Precast Concrete Sandwich Wall Panels Using an S-Type Shear Connector. <italic>Buildings</italic>, 14, Article 1725. https://doi.org/10.3390/buildings14061725 <pub-id pub-id-type="doi">10.3390/buildings14061725</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/buildings14061725">https://doi.org/10.3390/buildings14061725</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Tawil, H.</string-name>
              <string-name>Tan, C.G.</string-name>
              <string-name>Sulong, N.H.</string-name>
              <string-name>Nazri, F.M.</string-name>
              <string-name>Shamsudin, M.F.</string-name>
              <string-name>Bunnori, N.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Optimization of Shear Resistance in Precast Concrete Sandwich Wall Panels Using an S-Type Shear Connector</article-title>
            <source>Buildings</source>
            <volume>14</volume>
            <elocation-id>1725</elocation-id>
            <pub-id pub-id-type="doi">10.3390/buildings14061725</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B33">
        <label>33.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Sylaj, V., Fam, A., Hachborn, M. and Burak, R. (2020) Flexural Response of Double-Wythe Insulated Ultra-High-Performance Concrete Panels with Low to Moderate Composite Action. <italic>PCI Journal</italic>, 65, 24-40. https://doi.org/10.15554/pcij65.1-01 <pub-id pub-id-type="doi">10.15554/pcij65.1-01</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15554/pcij65.1-01">https://doi.org/10.15554/pcij65.1-01</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Sylaj, V.</string-name>
              <string-name>Fam, A.</string-name>
              <string-name>Hachborn, M.</string-name>
              <string-name>Burak, R.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Flexural Response of Double-Wythe Insulated Ultra-High-Performance Concrete Panels with Low to Moderate Composite Action</article-title>
            <source>PCI Journal</source>
            <volume>65</volume>
            <pub-id pub-id-type="doi">10.15554/pcij65.1-01</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B34">
        <label>34.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Haffke, M., Pahn, M., Thiele, C. and Grzesiak, S. (2022) Experimental Investigation of Concrete Sandwich Walls with Glass-Fiber-Composite Connectors Exposed to Fire and Mechanical Loading. <italic>Applied Sciences</italic>, 12, Article 3872. https://doi.org/10.3390/app12083872 <pub-id pub-id-type="doi">10.3390/app12083872</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/app12083872">https://doi.org/10.3390/app12083872</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Haffke, M.</string-name>
              <string-name>Pahn, M.</string-name>
              <string-name>Thiele, C.</string-name>
              <string-name>Grzesiak, S.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Experimental Investigation of Concrete Sandwich Walls with Glass-Fiber-Composite Connectors Exposed to Fire and Mechanical Loading</article-title>
            <source>Applied Sciences</source>
            <volume>12</volume>
            <elocation-id>3872</elocation-id>
            <pub-id pub-id-type="doi">10.3390/app12083872</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B35">
        <label>35.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Yang, Y., Ge, Z., Li, Y., Xiong, Y. and Yuan, Q. (2023) Study on Impact Resistance of Precast Light-Weight Concrete Sandwich Panels. <italic>Structures</italic>, 47, 966-975. https://doi.org/10.1016/j.istruc.2022.11.112 <pub-id pub-id-type="doi">10.1016/j.istruc.2022.11.112</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2022.11.112">https://doi.org/10.1016/j.istruc.2022.11.112</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Yang, Y.</string-name>
              <string-name>Ge, Z.</string-name>
              <string-name>Li, Y.</string-name>
              <string-name>Xiong, Y.</string-name>
              <string-name>Yuan, Q.</string-name>
            </person-group>
            <year>2023</year>
            <article-title>Study on Impact Resistance of Precast Light-Weight Concrete Sandwich Panels</article-title>
            <source>Structures</source>
            <volume>47</volume>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2022.11.112</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B36">
        <label>36.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Awan, A.B. and Shaikh, F.U.A. (2021) Structural Behavior of Recycled Tire Crumb Rubber Sandwich Panel in Flexural Bending. <italic>Structural Concrete</italic>, 22, 3602-3619. https://doi.org/10.1002/suco.202100356 <pub-id pub-id-type="doi">10.1002/suco.202100356</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/suco.202100356">https://doi.org/10.1002/suco.202100356</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Awan, A.B.</string-name>
              <string-name>Shaikh, F.U.A.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Structural Behavior of Recycled Tire Crumb Rubber Sandwich Panel in Flexural Bending</article-title>
            <source>Structural Concrete</source>
            <volume>22</volume>
            <pub-id pub-id-type="doi">10.1002/suco.202100356</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B37">
        <label>37.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Lameiras, R., Valente, I.B., Barros, J.A.O., Azenha, M. and Gonçalves, C. (2018) Pull-Out Behaviour of Glass-Fibre Reinforced Polymer Perforated Plate Connectors Embedded in Concrete. Part I: Experimental Program. <italic>Construction and Building Materials</italic>, 162, 155-169. https://doi.org/10.1016/j.conbuildmat.2017.12.021 <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2017.12.021</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.conbuildmat.2017.12.021">https://doi.org/10.1016/j.conbuildmat.2017.12.021</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Lameiras, R.</string-name>
              <string-name>Valente, I.B.</string-name>
              <string-name>Barros, J.A.O.</string-name>
              <string-name>Azenha, M.</string-name>
            </person-group>
            <year>2018</year>
            <article-title>Pull-Out Behaviour of Glass-Fibre Reinforced Polymer Perforated Plate Connectors Embedded in Concrete</article-title>
            <source>Part I: Experimental Program. Construction and Building Materials</source>
            <volume>162</volume>
            <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2017.12.021</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B38">
        <label>38.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Ke, L., Wu, X., Yan, B., Li, W. and Li, Y. (2024) Flexural Performance of UHPC Sandwich Panels with UHPC-Filled Stainless Steel Pipe Shear Connectors. <italic>Structures</italic>, 70, Article 107721. https://doi.org/10.1016/j.istruc.2024.107721 <pub-id pub-id-type="doi">10.1016/j.istruc.2024.107721</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2024.107721">https://doi.org/10.1016/j.istruc.2024.107721</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Ke, L.</string-name>
              <string-name>Wu, X.</string-name>
              <string-name>Yan, B.</string-name>
              <string-name>Li, W.</string-name>
              <string-name>Li, Y.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Flexural Performance of UHPC Sandwich Panels with UHPC-Filled Stainless Steel Pipe Shear Connectors</article-title>
            <source>Structures</source>
            <volume>70</volume>
            <elocation-id>107721</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2024.107721</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B39">
        <label>39.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Zhao, B., Du, L., Chen, G., Yue, L., Cui, C. and Ge, M. (2024) Experimental and Numerical Study on the Shear Performance of Stainless Steel-GFRP Connectors for Use in Precast Concrete Sandwich Panels. <italic>Scientific Reports</italic>, 14, Article No. 13814. https://doi.org/10.1038/s41598-024-64543-1 <pub-id pub-id-type="doi">10.1038/s41598-024-64543-1</pub-id><pub-id pub-id-type="pmid">38877195</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1038/s41598-024-64543-1">https://doi.org/10.1038/s41598-024-64543-1</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Zhao, B.</string-name>
              <string-name>Du, L.</string-name>
              <string-name>Chen, G.</string-name>
              <string-name>Yue, L.</string-name>
              <string-name>Cui, C.</string-name>
              <string-name>Ge, M.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Experimental and Numerical Study on the Shear Performance of Stainless Steel-GFRP Connectors for Use in Precast Concrete Sandwich Panels</article-title>
            <source>Scientific Reports</source>
            <volume>14</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1038/s41598-024-64543-1</pub-id>
            <pub-id pub-id-type="pmid">38877195</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B40">
        <label>40.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Ke, L., Zhang, Y., Yan, B., Wu, X., Li, W. and Zhou, C. (2025) Full-Scale Experimental Study on Shear Performance of UHPC Sandwich Panels with UHPC-Filled Stainless Steel Pipe Shear Connectors. <italic>Structures</italic>, 78, Article 109395. https://doi.org/10.1016/j.istruc.2025.109395 <pub-id pub-id-type="doi">10.1016/j.istruc.2025.109395</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.istruc.2025.109395">https://doi.org/10.1016/j.istruc.2025.109395</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Ke, L.</string-name>
              <string-name>Zhang, Y.</string-name>
              <string-name>Yan, B.</string-name>
              <string-name>Wu, X.</string-name>
              <string-name>Li, W.</string-name>
              <string-name>Zhou, C.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>Full-Scale Experimental Study on Shear Performance of UHPC Sandwich Panels with UHPC-Filled Stainless Steel Pipe Shear Connectors</article-title>
            <source>Structures</source>
            <volume>78</volume>
            <elocation-id>109395</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.istruc.2025.109395</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B41">
        <label>41.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Fahmy, M., Attia, W., Al-Kader A Al Sayed, A. and Ibrahim, H. (2024) Shear Performance of X and Z Configuration Wythe Ties for Insulated Precast Concrete Sandwich Panels Using Different FRP Materials. <italic>Journal of Building Engineering</italic>, 85, Article 108701. https://doi.org/10.1016/j.jobe.2024.108701 <pub-id pub-id-type="doi">10.1016/j.jobe.2024.108701</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2024.108701">https://doi.org/10.1016/j.jobe.2024.108701</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Fahmy, M.</string-name>
              <string-name>Attia, W.</string-name>
              <string-name>Sayed, A.</string-name>
              <string-name>Ibrahim, H.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Shear Performance of X and Z Configuration Wythe Ties for Insulated Precast Concrete Sandwich Panels Using Different FRP Materials</article-title>
            <source>Journal of Building Engineering</source>
            <volume>85</volume>
            <elocation-id>108701</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2024.108701</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B42">
        <label>42.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Cheng, N., Tang, J., Feng, P., Hao, Z., Zhang, Y. and Chang, M. (2024) Experimental and Theoretical Study on Flexural Performance of Light-Weight Sandwich Panels Using FRP Connectors. <italic>Case Studies in Construction Materials</italic>, 21, e03947.</mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Cheng, N.</string-name>
              <string-name>Tang, J.</string-name>
              <string-name>Feng, P.</string-name>
              <string-name>Hao, Z.</string-name>
              <string-name>Zhang, Y.</string-name>
              <string-name>Chang, M.</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Experimental and Theoretical Study on Flexural Performance of Light-Weight Sandwich Panels Using FRP Connectors</article-title>
            <source>Case Studies in Construction Materials</source>
            <volume>21</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B43">
        <label>43.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Annaba, K., El Wardi, F.Z., Ibaaz, K., Bouyahyaoui, A., Cherkaoui, M., Ouaki, B., <italic>et al</italic>. (2022) Thermomechanical Characterization and Thermal Simulation of a New Multilayer Mortar and a Light-Weight Pozzolanic Concrete for Building Energy Efficiency. <italic>Construction and Building Materials</italic>, 346, Article 128479. https://doi.org/10.1016/j.conbuildmat.2022.128479 <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2022.128479</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.conbuildmat.2022.128479">https://doi.org/10.1016/j.conbuildmat.2022.128479</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Annaba, K.</string-name>
              <string-name>Wardi, F.Z.</string-name>
              <string-name>Ibaaz, K.</string-name>
              <string-name>Bouyahyaoui, A.</string-name>
              <string-name>Cherkaoui, M.</string-name>
              <string-name>Ouaki, B.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Thermomechanical Characterization and Thermal Simulation of a New Multilayer Mortar and a Light-Weight Pozzolanic Concrete for Building Energy Efficiency</article-title>
            <source>Construction and Building Materials</source>
            <volume>346</volume>
            <elocation-id>128479</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2022.128479</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B44">
        <label>44.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Egbon, B. and Tomlinson, D. (2021) Experimental Investigation of Longitudinal Shear Transfer in Insulated Concrete Wall Panels with Notched Insulation. <italic>Journal of Building Engineering</italic>, 43, Article 103173. https://doi.org/10.1016/j.jobe.2021.103173 <pub-id pub-id-type="doi">10.1016/j.jobe.2021.103173</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2021.103173">https://doi.org/10.1016/j.jobe.2021.103173</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Egbon, B.</string-name>
              <string-name>Tomlinson, D.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Experimental Investigation of Longitudinal Shear Transfer in Insulated Concrete Wall Panels with Notched Insulation</article-title>
            <source>Journal of Building Engineering</source>
            <volume>43</volume>
            <elocation-id>103173</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jobe.2021.103173</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B45">
        <label>45.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Ding, R., Sun, Y., Fan, J. and Chen, D. (2022) Experimental and Theoretical Study on Flexural Behaviour of a New UHPC Sandwich Slab. <italic>Engineering Structures</italic>, 267, Article 114673. https://doi.org/10.1016/j.engstruct.2022.114673 <pub-id pub-id-type="doi">10.1016/j.engstruct.2022.114673</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2022.114673">https://doi.org/10.1016/j.engstruct.2022.114673</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Ding, R.</string-name>
              <string-name>Sun, Y.</string-name>
              <string-name>Fan, J.</string-name>
              <string-name>Chen, D.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Experimental and Theoretical Study on Flexural Behaviour of a New UHPC Sandwich Slab</article-title>
            <source>Engineering Structures</source>
            <volume>267</volume>
            <elocation-id>114673</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2022.114673</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B46">
        <label>46.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Huang, Q., Hamed, E. and Gilbert, R.I. (2020) Early-Age Shrinkage Effects in Precast Concrete Sandwich Panels. <italic>PCI Journal</italic>, 65, 74-88. https://doi.org/10.15554/pcij65.1-04 <pub-id pub-id-type="doi">10.15554/pcij65.1-04</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15554/pcij65.1-04">https://doi.org/10.15554/pcij65.1-04</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Huang, Q.</string-name>
              <string-name>Hamed, E.</string-name>
              <string-name>Gilbert, R.I.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Early-Age Shrinkage Effects in Precast Concrete Sandwich Panels</article-title>
            <source>PCI Journal</source>
            <volume>65</volume>
            <pub-id pub-id-type="doi">10.15554/pcij65.1-04</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B47">
        <label>47.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Xue, W., Li, Y., Fu, K., Hu, X. and Li, Y. (2020) Accelerated Ageing Test and Durability Prediction Model for Mechanical Properties of GFRP Connectors in Precast Concrete Sandwich Panels. <italic>Construction and Building Materials</italic>, 237, Article 117632. https://doi.org/10.1016/j.conbuildmat.2019.117632 <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2019.117632</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.conbuildmat.2019.117632">https://doi.org/10.1016/j.conbuildmat.2019.117632</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Xue, W.</string-name>
              <string-name>Li, Y.</string-name>
              <string-name>Fu, K.</string-name>
              <string-name>Hu, X.</string-name>
              <string-name>Li, Y.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Accelerated Ageing Test and Durability Prediction Model for Mechanical Properties of GFRP Connectors in Precast Concrete Sandwich Panels</article-title>
            <source>Construction and Building Materials</source>
            <volume>237</volume>
            <elocation-id>117632</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2019.117632</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B48">
        <label>48.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Lameiras, R., Barros, J.A.O., Valente, I.B., Poletti, E., Azevedo, M. and Azenha, M. (2021) Seismic Behaviour of Precast Sandwich Wall Panels of Steel Fibre Reinforced Concrete Layers and Fibre Reinforced Polymer Connectors. <italic>Engineering Structures</italic>, 237, Article 112149. https://doi.org/10.1016/j.engstruct.2021.112149 <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.112149</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2021.112149">https://doi.org/10.1016/j.engstruct.2021.112149</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Lameiras, R.</string-name>
              <string-name>Barros, J.A.O.</string-name>
              <string-name>Valente, I.B.</string-name>
              <string-name>Poletti, E.</string-name>
              <string-name>Azevedo, M.</string-name>
              <string-name>Azenha, M.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Seismic Behaviour of Precast Sandwich Wall Panels of Steel Fibre Reinforced Concrete Layers and Fibre Reinforced Polymer Connectors</article-title>
            <source>Engineering Structures</source>
            <volume>237</volume>
            <elocation-id>112149</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.engstruct.2021.112149</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
    </ref-list>
  </back>
</article>