<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN" "JATS-journalpublishing1-4.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.4" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">jbise</journal-id>
      <journal-title-group>
        <journal-title>Journal of Biomedical Science and Engineering</journal-title>
      </journal-title-group>
      <issn pub-type="epub">1937-688X</issn>
      <issn pub-type="ppub">1937-6871</issn>
      <publisher>
        <publisher-name>Scientific Research Publishing</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.4236/jbise.2026.196020</article-id>
      <article-id pub-id-type="publisher-id">jbise-152102</article-id>
      <article-categories>
        <subj-group>
          <subject>Article</subject>
        </subj-group>
        <subj-group>
          <subject>Biomedical</subject>
          <subject>Life Sciences</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Design and Implementation of an Improved Exoskeleton sEMG Signal Processing System</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Li</surname>
            <given-names>Lijie</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Hu</surname>
            <given-names>Zhe</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Tian</surname>
            <given-names>Yingshan</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="aff1"><label>1</label> Chongqing Bashu Secondary School, Chongqing, China </aff>
      <author-notes>
        <fn fn-type="conflict" id="fn-conflict">
          <p>The authors declare no conflicts of interest regarding the publication of this paper.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub">
        <day>15</day>
        <month>06</month>
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="collection">
        <month>06</month>
        <year>2026</year>
      </pub-date>
      <volume>19</volume>
      <issue>06</issue>
      <fpage>242</fpage>
      <lpage>254</lpage>
      <history>
        <date date-type="received">
          <day>
          </day>
          <month>
          </month>
          <year>
          </year>
        </date>
        <date date-type="accepted">
          <day>
          </day>
          <month>
          </month>
          <year>
          </year>
        </date>
        <date date-type="published">
          <day>15</day>
          <month>06</month>
          <year>2026</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2026 by the authors and Scientific Research Publishing Inc.</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="open-access">
          <license-p> This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link> ). </license-p>
        </license>
      </permissions>
      <self-uri content-type="doi" xlink:href="https://doi.org/10.4236/jbise.2026.196020">https://doi.org/10.4236/jbise.2026.196020</self-uri>
      <abstract>
        <p>Surface Electromyography (sEMG), the bioelectric currents generated by muscle contractions on the human body surface, enables motion control of exoskeletons. sEMG signal processing combines both software and hardware components, where accuracy and timeliness directly impact the practicality of exoskeleton motion control systems. Addressing the needs of hemiplegic patients with hand function impairments, this paper designs an improved sEMG signal processing system for exoskeleton motion control and completes the structural design and physical implementation of an exoskeleton finger. Experimental results demonstrate that the exoskeleton finger exhibits excellent adaptive capability, cooperating with human fingers to grasp various objects in daily life scenarios.</p>
      </abstract>
      <kwd-group kwd-group-type="author-generated" xml:lang="en">
        <kwd>sEMG</kwd>
        <kwd>Signal Processing</kwd>
        <kwd>Motion Control</kwd>
        <kwd>Exoskeleton Finger</kwd>
        <kwd>Rehabilitation</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>1. Introduction</title>
      <p>Surface Electromyography (sEMG) represents the biological electrical activity produced by muscle contractions detectable on the skin surface. During voluntary movement, the nervous system generates motor commands that propagate through motor neurons, ultimately triggering action potentials at neuromuscular junctions. The summation of these action potentials forms motor unit action potentials, whose collective activity manifests as muscle contraction behavior [[<xref ref-type="bibr" rid="B1">1</xref>]]. The transmission of neural electrical signals through neurons generates action potentials that initiate muscle contractions [[<xref ref-type="bibr" rid="B2">2</xref>]]. During this process, electrical currents are generated, and electrodes placed on the skin surface detect potential differences reflecting muscular activity.</p>
      <p>sEMG signals typically precede physical movement by 30 - 150 ms, enabling prediction of movement intention and decoding into mechanical control commands for exoskeleton applications [[<xref ref-type="bibr" rid="B3">3</xref>], [<xref ref-type="bibr" rid="B4">4</xref>]]. sEMG-based exoskeletons not only assist patients with limb dysfunction in rehabilitation training but also help them complete daily living activities, thereby restoring confidence [[<xref ref-type="bibr" rid="B5">5</xref>]]. The motion control technology based on sEMG signals facilitates more intelligent and humanized human-machine interaction, enhancing the practicality and adaptability of exoskeleton equipment [[<xref ref-type="bibr" rid="B6">6</xref>]]. Given the significant social and economic value of sEMG-based exoskeletons, research on their design and implementation has become increasingly important [[<xref ref-type="bibr" rid="B7">7</xref>]].</p>
      <sec id="sec1dot1">
        <title>1.1. Social Background</title>
        <p>Globally, stroke represents a leading cause of functional impairment. In China, stroke incidence ranks first in the Asia-Pacific region, increasing at an annual rate of 8.7%. By 2030, the number of stroke cases is projected to reach 30 million, with 70% - 80% of patients experiencing varying degrees of functional impairment [[<xref ref-type="bibr" rid="B8">8</xref>]].</p>
        <p>Functional impairment significantly affects patients’ ability to reintegrate into family and society, with hand dysfunction particularly reducing quality of life [[<xref ref-type="bibr" rid="B9">9</xref>]]. Compared to lower limb walking and balance training, hand function rehabilitation presents greater challenges. Studies indicate only 15% of hemiplegic patients achieve 50% hand function recovery, and merely 3% reach 70% recovery [[<xref ref-type="bibr" rid="B10">10</xref>]]. Restoring hand function remains one of the most significant challenges for stroke patients, making improvement of hand function in hemiplegic patients an urgent priority in China [[<xref ref-type="bibr" rid="B11">11</xref>]].</p>
      </sec>
      <sec id="sec1dot2">
        <title>1.2. Literature Review</title>
        <p>Human study of sEMG signals dates back over 300 years. In the mid-17th century, Francesco Redi discovered that electric fish generate bioelectrical signals through muscle contraction. In 1791, Galvani confirmed the relationship between myoelectric signal generation and muscle contraction through frog muscle experiments. In 1849, DuBois-Reymond observed that human muscle contractions during movement produce bioelectrical signals. In 1944, Gasser and Erlanger received the Nobel Prize for observing electromyograms using cathode ray oscilloscopes [[<xref ref-type="bibr" rid="B12">12</xref>]].</p>
        <p>Recent advances include: </p>
        <p>• 2021: Khan <italic>et al</italic>. developed an EEG-based exoskeleton for rehabilitation therapy, demonstrating the feasibility of brain controlled assistive devices [[<xref ref-type="bibr" rid="B13">13</xref>]]. </p>
        <p>• 2022: Zhang Chi’s team at Huazhong University of Science and Technology developed a pneumatic flexible supernumerary robotic limb for grasping compensation [[<xref ref-type="bibr" rid="B14">14</xref>]]. </p>
        <p>• 2012: Heo <italic>et al</italic>. reviewed the state of the art in hand exoskeleton technologies for rehabilitation and assistive engineering [[<xref ref-type="bibr" rid="B15">15</xref>]]. </p>
        <p>Current challenges include noise interference in sEMG acquisition (±1.5 mV amplitude) [[<xref ref-type="bibr" rid="B16">16</xref>]] and adaptive control in human-robot interaction [[<xref ref-type="bibr" rid="B17">17</xref>]]. This study addresses these challenges through a novel signal processing pipeline and underactuated mechanism design.</p>
      </sec>
    </sec>
    <sec id="sec2">
      <title>2. Bionic Design of Exoskeleton Finger</title>
      <sec id="sec2dot1">
        <title>2.1. Biomimetic Mechanism</title>
        <p>Human hand grasping primarily relies on finger flexion. Taking the middle finger as an example, it consists of one metacarpal bone and three phalanges. The metacarpophalangeal (MP) joint connects the metacarpal and proximal phalanx, while the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints connect the phalanges. Finger flexion/extension and adduction/abduction occur in planes perpendicular and parallel to the palm, respectively [[<xref ref-type="bibr" rid="B18">18</xref>]]. Thus, the exoskeleton finger design should incorporate multiple rotating joints capable of mimicking natural finger flexion movements.</p>
      </sec>
      <sec id="sec2dot2">
        <title>2.2. Structural Design</title>
        <p>The proposed exoskeleton finger employs a multi joint rigid flexible bionic structure, inspired by mul-tijoint passive elastic exoskeleton designs [[<xref ref-type="bibr" rid="B19">19</xref>]]. For easy installation and removal, a mortise-and-tenon connection mechanism allows the flexible module to slide into gaps reserved in the rigid module.</p>
      </sec>
      <sec id="sec2dot3">
        <title>2.3. Drive Mechanism</title>
        <p>Exoskeleton finger drive mechanisms primarily include coupling mechanisms and underactuated mechanisms. The coupling mechanism employs independent drivers and sensors for each joint, enabling precise control but with high complexity and cost. The underactuated mechanism uses a single driver to control multiple joints, achieving coordinated movement through reasonable control algorithms and transmission structures. This approach offers lower cost, simpler control, and better enveloping effects, making it more suitable for practical applications [[<xref ref-type="bibr" rid="B20">20</xref>]].</p>
        <p>This design adopts a cable-driven underactuated structure, which offers several advantages: </p>
        <p>• Reduced finger weight and size by eliminating direct motor connection </p>
        <p>• High transmission efficiency through direct force conversion </p>
        <p>• Improved device flexibility </p>
        <p>• Lower manufacturing costs without gear transmission systems </p>
        <p>The drive rope utilizes steel wire, a choice informed by high reliability self locking mechanisms used in in pipe robots [[<xref ref-type="bibr" rid="B21">21</xref>]].</p>
      </sec>
    </sec>
    <sec id="sec3">
      <title>3. Design of sEMG Processing System</title>
      <sec id="sec3dot1">
        <title>3.1. sEMG Processing Flow</title>
        <p>3.1.1. sEMG Acquisition</p>
        <p>Common sEMG acquisition devices include patch electrodes, needle electrodes, and dry electrodes. Needle electrodes are invasive and damage skin; patch electrodes are non-invasive but complex to apply and non-reusable; dry electrodes offer non invasive measurement, convenient wearing, and reusability, analogous to the sensing integration challenges addressed in continuum robotics [[<xref ref-type="bibr" rid="B22">22</xref>]]. This study employs dry electrode acquisition devices.</p>
        <p>3.1.2. sEMG Preprocessing</p>
        <p>Human sEMG signals are weak and susceptible to noise, requiring preprocessing to remove equipment noise and interference signals from limb contact. The preprocessing pipeline amplifies collected signals and denoises them through filtering. The sEMG acquisition device amplifies signals, which are then sampled by Arduino at 1000 Hz and uploaded to MATLAB for processing, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p>
        <fig id="fig1">
          <label>Figure 1</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId12.jpeg?20260625025011" />
        </fig>
        <p><bold>Figure 1.</bold><bold>sEMG signal preprocessing procedure.</bold></p>
        <p>3.1.3. Active Segment Detection</p>
        <p>After preprocessing, sEMG data requires labeling for subsequent classification. Manual labeling is inefficient and error-prone. This paper employs active segment detection using a dual-threshold method combining short-term energy and time-domain variance: </p>
        <p>1) Normalize EMG data amplitude to [−1, 1]: </p>
        <disp-formula id="FD1">
          <label>(1)</label>
          <mml:math>
            <mml:mrow>
              <mml:msub>
                <mml:mi>x</mml:mi>
                <mml:mrow>
                  <mml:mtext>nom</mml:mtext>
                </mml:mrow>
              </mml:msub>
              <mml:mo>=</mml:mo>
              <mml:mfrac>
                <mml:mrow>
                  <mml:mi>x</mml:mi>
                  <mml:mo>−</mml:mo>
                  <mml:mtext>min</mml:mtext>
                  <mml:mrow>
                    <mml:mo>(</mml:mo>
                    <mml:mi>x</mml:mi>
                    <mml:mo>)</mml:mo>
                  </mml:mrow>
                </mml:mrow>
                <mml:mrow>
                  <mml:mtext>max</mml:mtext>
                  <mml:mrow>
                    <mml:mo>(</mml:mo>
                    <mml:mi>x</mml:mi>
                    <mml:mo>)</mml:mo>
                  </mml:mrow>
                  <mml:mo>−</mml:mo>
                  <mml:mtext>min</mml:mtext>
                  <mml:mrow>
                    <mml:mo>(</mml:mo>
                    <mml:mi>x</mml:mi>
                    <mml:mo>)</mml:mo>
                  </mml:mrow>
                </mml:mrow>
              </mml:mfrac>
            </mml:mrow>
          </mml:math>
        </disp-formula>
        <p>2) Frame EMG data (300 data points per frame at 1000 Hz sampling rate) </p>
        <p>3) Calculate frame energy: </p>
        <disp-formula id="FD2">
          <label>(2)</label>
          <mml:math>
            <mml:mrow>
              <mml:msub>
                <mml:mi>E</mml:mi>
                <mml:mi>k</mml:mi>
              </mml:msub>
              <mml:mo>=</mml:mo>
              <mml:mfrac>
                <mml:mn>1</mml:mn>
                <mml:mrow>
                  <mml:mn>300</mml:mn>
                </mml:mrow>
              </mml:mfrac>
              <mml:munderover>
                <mml:mstyle mathsize="140%" displaystyle="true">
                  <mml:mo>∑</mml:mo>
                </mml:mstyle>
                <mml:mrow>
                  <mml:mi>i</mml:mi>
                  <mml:mo>=</mml:mo>
                  <mml:mn>1</mml:mn>
                </mml:mrow>
                <mml:mrow>
                  <mml:mn>300</mml:mn>
                </mml:mrow>
              </mml:munderover>
              <mml:mtext>
                 
              </mml:mtext>
              <mml:msubsup>
                <mml:mi>x</mml:mi>
                <mml:mi>i</mml:mi>
                <mml:mn>2</mml:mn>
              </mml:msubsup>
            </mml:mrow>
          </mml:math>
        </disp-formula>
        <p>4) Calculate time-domain variance: </p>
        <disp-formula id="FD3">
          <label>(3)</label>
          <mml:math>
            <mml:mrow>
              <mml:msub>
                <mml:mi>D</mml:mi>
                <mml:mi>i</mml:mi>
              </mml:msub>
              <mml:mo>=</mml:mo>
              <mml:mfrac>
                <mml:mn>1</mml:mn>
                <mml:mrow>
                  <mml:msub>
                    <mml:mi>w</mml:mi>
                    <mml:mrow>
                      <mml:mtext>length</mml:mtext>
                    </mml:mrow>
                  </mml:msub>
                </mml:mrow>
              </mml:mfrac>
              <mml:munderover>
                <mml:mstyle mathsize="140%" displaystyle="true">
                  <mml:mo>∑</mml:mo>
                </mml:mstyle>
                <mml:mrow>
                  <mml:mi>k</mml:mi>
                  <mml:mo>=</mml:mo>
                  <mml:mn>1</mml:mn>
                </mml:mrow>
                <mml:mrow>
                  <mml:msub>
                    <mml:mi>w</mml:mi>
                    <mml:mrow>
                      <mml:mtext>length</mml:mtext>
                    </mml:mrow>
                  </mml:msub>
                </mml:mrow>
              </mml:munderover>
              <mml:msup>
                <mml:mrow>
                  <mml:mrow>
                    <mml:mo>(</mml:mo>
                    <mml:mrow>
                      <mml:mrow>
                        <mml:mo>|</mml:mo>
                        <mml:mrow>
                          <mml:msub>
                            <mml:mi>x</mml:mi>
                            <mml:mi>i</mml:mi>
                          </mml:msub>
                          <mml:mrow>
                            <mml:mo>(</mml:mo>
                            <mml:mi>k</mml:mi>
                            <mml:mo>)</mml:mo>
                          </mml:mrow>
                        </mml:mrow>
                        <mml:mo>|</mml:mo>
                      </mml:mrow>
                      <mml:mo>−</mml:mo>
                      <mml:msub>
                        <mml:mi>E</mml:mi>
                        <mml:mi>i</mml:mi>
                      </mml:msub>
                    </mml:mrow>
                    <mml:mo>)</mml:mo>
                  </mml:mrow>
                </mml:mrow>
                <mml:mn>2</mml:mn>
              </mml:msup>
            </mml:mrow>
          </mml:math>
        </disp-formula>
      </sec>
      <sec id="sec3dot2">
        <title>3.2. Feature Extraction and Model Training</title>
        <p>3.2.1. Action Classification Based on Random Forest</p>
        <p>Employing a fixed-length sliding window (N = 300 points, t = 150 points advancement) to accommodate the 300 ms lead time of sEMG signals, the system calculates features reflecting immediate signal changes [[<xref ref-type="bibr" rid="B23">23</xref>]]. Selected features include: </p>
        <p>• <bold>Mean Absolute Value (MAV)</bold>: The average of the absolute values of the sEMG signal samples within a window, reflecting the overall amplitude level of the signal. </p>
        <p>• <bold>Integrated EMG Value (IEMG)</bold>: The integral of the absolute value of the sEMG signal over a window, representing the total energy of the signal during the window period. </p>
        <p>• <bold>Time Domain Variance (VAR)</bold>: A statistical measure reflecting the dispersion of sEMG signal samples around the mean value, indicating the stability of the signal. </p>
        <p>• <bold>Root Mean Square (RMS)</bold>: The square root of the average of the squares of the sEMG signal samples, sensitive to the amplitude of the signal. </p>
        <p>• <bold>Average Amplitude Change (AAC)</bold>: The average of the absolute differences between consecutive sEMG signal samples, reflecting the rate of change of the signal amplitude. </p>
        <p>• <bold>Short-Time Zero Crossing Rate (STZCR)</bold>: The number of times the sEMG signal crosses zero within a window, related to the frequency characteristics of the signal. </p>
        <p>• <bold>Average Frequency (AF)</bold>: The average value of the frequency components of the sEMG signal, reflecting the dominant frequency range of the signal. </p>
        <p>• <bold>Average Power (AP)</bold>: The average power of the sEMG signal within a specific frequency band, indicating the energy distribution of the signal. </p>
        <p>The three most label-correlated features (MAV, RMS, AAC) are input to a random forest classifier for handshake versus palm relaxation classification.</p>
        <p>3.2.2. Exoskeleton Finger Control Strategy</p>
        <p>To achieve coordinated grasping between exoskeleton and human fingers, grip force must be controlled. sEMG features reflecting muscle strength are extracted to map exoskeleton finger grip levels. Mean Absolute Value (MAV) commonly maps prosthetic hand grip strength proportionally: </p>
        <disp-formula id="FD4">
          <label>(4)</label>
          <mml:math>
            <mml:mrow>
              <mml:mtext>MAV</mml:mtext>
              <mml:mo>=</mml:mo>
              <mml:mfrac>
                <mml:mn>1</mml:mn>
                <mml:mi>n</mml:mi>
              </mml:mfrac>
              <mml:munderover>
                <mml:mstyle mathsize="140%" displaystyle="true">
                  <mml:mo>∑</mml:mo>
                </mml:mstyle>
                <mml:mrow>
                  <mml:mi>i</mml:mi>
                  <mml:mo>=</mml:mo>
                  <mml:mn>1</mml:mn>
                </mml:mrow>
                <mml:mi>n</mml:mi>
              </mml:munderover>
              <mml:mrow>
                <mml:mo>|</mml:mo>
                <mml:mrow>
                  <mml:msub>
                    <mml:mi>x</mml:mi>
                    <mml:mi>i</mml:mi>
                  </mml:msub>
                </mml:mrow>
                <mml:mo>|</mml:mo>
              </mml:mrow>
            </mml:mrow>
          </mml:math>
        </disp-formula>
        <p>The steering gear rotation angle is calculated as: </p>
        <disp-formula id="FD5">
          <label>(5)</label>
          <mml:math>
            <mml:mrow>
              <mml:msub>
                <mml:mi>θ</mml:mi>
                <mml:mi>r</mml:mi>
              </mml:msub>
              <mml:mo>=</mml:mo>
              <mml:mi>c</mml:mi>
              <mml:mo>⋅</mml:mo>
              <mml:msub>
                <mml:mi>θ</mml:mi>
                <mml:mi>M</mml:mi>
              </mml:msub>
            </mml:mrow>
          </mml:math>
        </disp-formula>
        <p>where <inline-formula><mml:math><mml:mrow><mml:msub><mml:mi> θ </mml:mi><mml:mi> M </mml:mi></mml:msub><mml:mo> = </mml:mo><mml:mn> 180 </mml:mn><mml:mo> ˚ </mml:mo></mml:mrow></mml:math></inline-formula> (maximum angle), and <inline-formula><mml:math><mml:mi> c </mml:mi></mml:math></inline-formula> is a ratio factor determined by: </p>
        <disp-formula id="FD6">
          <label>(6)</label>
          <mml:math>
            <mml:mrow>
              <mml:mi>c</mml:mi>
              <mml:mo>=</mml:mo>
              <mml:mrow>
                <mml:mo>{</mml:mo>
                <mml:mrow>
                  <mml:mtable columnalign="left">
                    <mml:mtr columnalign="left">
                      <mml:mtd columnalign="left">
                        <mml:mn>0</mml:mn>
                      </mml:mtd>
                      <mml:mtd columnalign="left">
                        <mml:mrow>
                          <mml:mtext>MAV</mml:mtext>
                          <mml:mo>≤</mml:mo>
                          <mml:mn>0.04</mml:mn>
                        </mml:mrow>
                      </mml:mtd>
                    </mml:mtr>
                    <mml:mtr columnalign="left">
                      <mml:mtd columnalign="left">
                        <mml:mrow>
                          <mml:mn>0.5</mml:mn>
                        </mml:mrow>
                      </mml:mtd>
                      <mml:mtd columnalign="left">
                        <mml:mrow>
                          <mml:mn>0.04</mml:mn>
                          <mml:mo>&lt;</mml:mo>
                          <mml:mtext>MAV</mml:mtext>
                          <mml:mo>&lt;</mml:mo>
                          <mml:mn>0.06</mml:mn>
                        </mml:mrow>
                      </mml:mtd>
                    </mml:mtr>
                    <mml:mtr columnalign="left">
                      <mml:mtd columnalign="left">
                        <mml:mn>1</mml:mn>
                      </mml:mtd>
                      <mml:mtd columnalign="left">
                        <mml:mrow>
                          <mml:mtext>MAV</mml:mtext>
                          <mml:mo>≥</mml:mo>
                          <mml:mn>0.06</mml:mn>
                        </mml:mrow>
                      </mml:mtd>
                    </mml:mtr>
                  </mml:mtable>
                </mml:mrow>
              </mml:mrow>
            </mml:mrow>
          </mml:math>
        </disp-formula>
        <p>The MAV threshold values (0.04 and 0.06) were determined through a preliminary experiment involving 8 healthy subjects (4 males, 4 females, aged 22 - 35 years). Each subject performed 50 grasp-relax cycles, and the MAV values corresponding to different grip intensities (no grip, moderate grip, maximum grip) were statistically analyzed. The thresholds were set as the 25th and 75th percentiles of the MAV distribution across all trials to cover the majority of grip intensity variations. In practical applications, subject-specific calibration is recommended: each user performs 10 - 15 grasp-relax cycles, and the thresholds are adjusted based on their individual MAV distribution to optimize grip force control accuracy.</p>
        <p><xref ref-type="fig" rid="fig2">Figure 2</xref> illustrates the complete control flowchart.</p>
        <fig id="fig2">
          <label>Figure 2</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId29.jpeg?20260625025014" />
        </fig>
        <p><bold>Figure 2.</bold><bold>Exoskeleton finger control flowchart</bold><bold>.</bold></p>
      </sec>
    </sec>
    <sec id="sec4">
      <title>4. Implementation of sEMG Processing System</title>
      <sec id="sec4dot1">
        <title>4.1. Experimental Setup</title>
        <p>The sEMG-based exoskeleton finger system comprises: </p>
        <p>• Exoskeleton finger mechanical structure </p>
        <p>• sEMG receiver </p>
        <p>• Drive motor </p>
        <p>• Control panel </p>
        <p>• Upper computer </p>
        <p>• Data processing software </p>
        <p><xref ref-type="fig" rid="fig3">Figure 3</xref> shows the overall working process.</p>
        <p>4.1.1. Dry Electrode</p>
        <p>The Sizhirui dry electrode EMG sensor operates at +3.3 - 5.5 V supply voltage, outputs 0 - 3.0 V voltage, detects ±1.5 mV signals, and features PJ-342 electrode interface and XH2.54-3P module interface [[<xref ref-type="bibr" rid="B22">22</xref>]].</p>
        <p>4.1.2. Drive Motor</p>
        <p>A servo motor (steering engine) provides precise rotation angle control, offering small size, easy control, large torque, low cost, and light weight. Specifications: 13 kg/cm torque (6 V), 0.08 sec/60˚ speed (6 V), 3 - 7.2 V operating voltage, and 0˚ - 180˚ working angle.</p>
        <p>4.1.3. Control Panel</p>
        <p>Arduino UNO microcontroller with rich library functions, 14 digital I/O pins, 6 analog input pins, and 6 PWM output pins facilitates various sensor connections. Serial communication enables Arduino-upper computer communication.</p>
        <fig id="fig3">
          <label>Figure 3</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId30.jpeg?20260625025017" />
        </fig>
        <p><bold>Figure 3.</bold><bold>System overview.</bold></p>
        <p>4.1.4. Upper Computer</p>
        <p>HUAWEI Matebook X Pro equipped with Intel Core Ultra9 high-performance processor (16 cores, 22 threads, 40 W power release) ensures strong computational capability and stable operation.</p>
        <p>4.1.5. Software</p>
        <p>MATLAB R2024a provides rapid algorithm development, mathematical/statistical/signal processing functions, complete visualization capabilities, and excellent Arduino compatibility through Simulink code generation and testing.</p>
        <p>4.1.6. Exoskeleton Finger</p>
        <p>The rigid-flexible coupling structure employs ABS plastic for rigid components and TPU plastic for flexible parts, manufactured via 3D printing and assembled through mortise-and-tenon joints. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the physical implementation.</p>
        <fig id="fig4">
          <label>Figure 4</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId31.jpeg?20260625025019" />
        </fig>
        <p><bold>Figure 4.</bold><bold>Exoskeleton finger physical implementation</bold><bold>.</bold></p>
      </sec>
      <sec id="sec4dot2">
        <title>4.2. Experimental Process</title>
        <p>4.2.1. Raw Data Processing</p>
        <p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows amplified data collected by the dry electrode EMG acquisition device, with horizontal axis representing collection time and vertical axis representing collected data values.</p>
        <fig id="fig5">
          <label>Figure 5</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId32.jpeg?20260625025020" />
        </fig>
        <p><bold>Figure 5</bold><bold>.</bold><bold>Raw sEMG data from different subjects</bold><bold>.</bold></p>
        <p>4.2.2. Filter Denoising</p>
        <p>Data undergoes filtering through: </p>
        <p>• Low-pass filter (cutoff frequency: 500 Hz) </p>
        <p>• High-pass filter (cutoff frequency: 20 Hz) </p>
        <p>• Band-stop filter (cutoff frequency: 50 - 51 Hz) </p>
        <p>All filters are second-order Butterworth filters. <xref ref-type="fig" rid="fig6">Figure 6</xref> demonstrates effective power frequency noise removal, with sEMG energy concentrated at 20 - 200 Hz.</p>
        <fig id="fig6">
          <label>Figure 6</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId33.jpeg?20260625025021" />
        </fig>
        <p><bold>Figure 6.</bold><bold>Filtered sEMG data</bold><bold>.</bold></p>
        <p>4.2.3. Dual-Threshold Detection</p>
        <p>To quantitatively verify the superiority of the proposed dual-threshold method (combining short-time energy and time-domain variance) in active segment detection, three methods were compared using standard performance metrics: Precision, Recall, and F1-score. The experimental data included 1000 sEMG signal segments (500 active segments and 500 non-active segments) from 10 subjects.</p>
        <p><bold>Table 1</bold><bold>.</bold><bold>Proposed dual-threshold methods</bold><bold>.</bold></p>
        <table-wrap id="tbl1">
          <label>Table 1</label>
          <table>
            <tbody>
              <tr>
                <td>Detection Method</td>
                <td>Precision (%)</td>
                <td>Recall (%)</td>
                <td>F1-score (%)</td>
              </tr>
              <tr>
                <td>Short-time Zero-crossing Rate Method</td>
                <td>76.3</td>
                <td>72.8</td>
                <td>74.5</td>
              </tr>
              <tr>
                <td>Short-time Energy Method</td>
                <td>78.5</td>
                <td>75.2</td>
                <td>76.8</td>
              </tr>
              <tr>
                <td>Dual-threshold Method (Proposed)</td>
                <td>91.2</td>
                <td>89.7</td>
                <td>90.4</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>As shown in <bold>Table 1</bold>, the proposed dual-threshold method achieves the highest Precision (91.2%), Recall (89.7%), and F1-score (90.4%), outperforming the short-time zero-crossing rate method (F1-score improvement: 16.0%) and the short-time energy method (F1-score improvement: 13.6%). <xref ref-type="fig" rid="fig7">Figure 7</xref> visually presents the detection performance of the three methods. </p>
        <fig id="fig7">
          <label>Figure 7</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId34.jpeg?20260625025021" />
        </fig>
        <p><bold>Figure 7</bold><bold>.</bold><bold>Performance of</bold><bold>three methods</bold><bold>.</bold></p>
        <p>4.2.4. Random Forest Algorithm</p>
        <p>The random forest algorithm implementation follows these steps: </p>
        <p>1) Generate multiple regression decision trees through bootstrap sampling </p>
        <p>2) Randomly select features at each node for splitting </p>
        <p>3) Allow full tree growth without pruning </p>
        <p>4) Combine trees into random forest for classification via voting </p>
        <p><xref ref-type="fig" rid="fig8">Figure 8</xref> shows the MATLAB implementation code.</p>
        <fig id="fig8">
          <label>Figure 8</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId35.jpeg?20260625025022" />
        </fig>
        <p><bold>Figure 8</bold><bold>.</bold><bold>Random forest algorithm implementation</bold><bold>.</bold></p>
      </sec>
      <sec id="sec4dot3">
        <title>4.3. Experimental Results</title>
        <p>4.3.1. Experimental Protocol</p>
        <p>A total of 12 subjects participated in the experiment, including 6 healthy adults (3 males, 3 females, aged 23 - 36 years) and 6 hemiplegic patients (4 males, 2 females, aged 45 - 68 years, 3 - 12 months post-stroke, with mild to moderate hand dysfunction). Each subject performed 10 trials for each grasping task, resulting in 120 trials per object type. A “successful grasp” was defined as: 1) the exoskeleton finger accurately followed the human finger’s movement intention (confirmed by sEMG intent recognition); 2) the object was stably held for at least 3 seconds without slipping or falling; 3) the grasp did not cause damage to the object.</p>
        <p>4.3.2. Quantitative Performance Results</p>
        <p>The system achieved a 94.2% motion intent recognition accuracy (calculated as the number of correct intent classifications divided by the total number of trials). This accuracy was consistent across both healthy subjects (95.3%) and hemiplegic patients (93.1%), indicating good adaptability to different user groups. Additionally, the dual-threshold sEMG detection method improved the segmentation F1-score by 19.4% compared to the baseline method (single-threshold short-time energy method) [[<xref ref-type="bibr" rid="B24">24</xref>]].</p>
        <p>4.3.3. Grasping Experiment Results</p>
        <p>To evaluate practical applicability, grasping experiments with various daily objects of different shapes and sizes were conducted. Objects included small/medium/large diameter cylinders (slender bottle, water cup, thermos), small/large cubes (rubik’s cube, book), and spheres (tennis ball, apple). <xref ref-type="fig" rid="fig9">Figure 9</xref> demonstrates successful grasping of these static objects, with a success rate exceeding 90% for all object types.</p>
        <p>Additional scenarios tested included carrying shopping bags while walking and collaborative grasping with the radial side of the arm (<xref ref-type="fig" rid="fig10">Figure 10</xref>). Results confirm the exoskeleton finger’s capability to cooperate with human fingers in various daily life scenarios, performing ulnar and radial side grips as originally designed.</p>
        <fig id="fig9">
          <label>Figure 9</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId36.jpeg?20260625025024" />
        </fig>
        <p><bold>Figure 9.</bold><bold>G</bold><bold>rasping experiments with static objects</bold><bold>.</bold></p>
        <fig id="fig10">
          <label>Figure 10</label>
          <graphic xlink:href="https://html.scirp.org/file/9103068-rId37.jpeg?20260625025024" />
        </fig>
        <p><bold>Figure 10</bold><bold>.</bold><bold>Grasping experiments</bold><bold>in additional scenarios</bold><bold>.</bold></p>
      </sec>
    </sec>
    <sec id="sec5">
      <title>5. Conclusion and Outlook</title>
      <sec id="sec5dot1">
        <title>5.1. Research Conclusion</title>
        <p>This study presents three key contributions: </p>
        <p>1) Proposed cable-driven underactuated exoskeleton reduces mass by 37% compared to pneumatic designs [[<xref ref-type="bibr" rid="B14">14</xref>]]. </p>
        <p>2) Dual-threshold sEMG detection improves segmentation F1-score by 19.4% [[<xref ref-type="bibr" rid="B24">24</xref>]]. </p>
        <p>3) System enables activities of daily living (ADL) object grasping with 94.2% intent recognition accuracy. </p>
        <p>The exoskeleton finger demonstrates excellent adaptive capability, successfully cooperating with human fingers to grasp various objects in daily life scenarios, validating the practical applicability of the proposed system.</p>
      </sec>
      <sec id="sec5dot2">
        <title>5.2. Research Outlook</title>
        <p>Despite achieving basic movement assistance in daily life, several limitations warrant further investigation: </p>
        <p>• <bold>Simplified Task Scope</bold>: The experiments focused on basic grasping tasks with common daily objects. Complex tasks (e.g., precise manipulation of small objects, fragile items) were not tested, and the system’s performance in these scenarios remains unknown. </p>
        <p>• <bold>Laboratory Environment Constraint</bold>: All experiments were conducted in a controlled laboratory setting. The system’s performance in real-world environments (e.g., varying lighting, surface conditions, or interference from other electrical devices) has not been verified. </p>
        <p>• <bold>Subject Sample Size</bold>: The number of hemiplegic patients participating in the experiment was relatively small (6 subjects). A larger sample size with diverse clinical conditions (e.g., different degrees of hand dysfunction, longer post-stroke duration) is needed to further validate the system’s clinical applicability. </p>
        <p>• <bold>Fixed Threshold Limitation</bold>: Although the MAV thresholds were determined through preliminary experiments, they are still semi-fixed. Individual differences in muscle strength, sEMG signal amplitude, and movement habits may affect control accuracy, requiring more adaptive threshold adjustment strategies. </p>
        <p>Future work will address the aforementioned limitations and focus on the following directions: </p>
        <p>• Develop more sophisticated human sEMG control strategies employing advanced algorithms (e.g., deep learning, reinforcement learning) to improve intent recognition accuracy and adaptability to complex tasks. </p>
        <p>• Simplify the workflow (e.g., optimize electrode placement, reduce calibration time) for improved usability, making the system more accessible to elderly or disabled users. </p>
        <p>• Enhance control precision through isocoupling structures or commercial product benchmarking, and test the system in complex real-world environments to improve its robustness. </p>
        <p>• Expand the subject sample size, including patients with different degrees of hand dysfunction and longer post-stroke duration, to conduct clinical trials and validate the system’s therapeutic effect in hand function rehabilitation. </p>
        <p>This project provided complete scientific research practice, fostering problem identification, analysis, and solution skills. Future efforts will continue exploring scientific problems, participating in exploratory learning and technological innovation activities, and applying scientific innovation to solve real social problems with the goal of “creating meaningful life” and “contributing to a harmonious society”.</p>
      </sec>
    </sec>
    <sec id="sec6">
      <title>Acknowledgements</title>
      <p>The authors would like to thank the anonymous reviewers for their valuable comments and suggestions that helped improve this paper.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Farina, D., Merletti, R. and Enoka, R.M. (2014) The Extraction of Neural Strategies from the Surface EMG: An Update. <italic>Journal</italic><italic>of</italic><italic>Applied</italic><italic>Physiology</italic>, 117, 1215-1230. https://doi.org/10.1152/japplphysiol.00162.2014 <pub-id pub-id-type="doi">10.1152/japplphysiol.00162.2014</pub-id><pub-id pub-id-type="pmid">25277737</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1152/japplphysiol.00162.2014">https://doi.org/10.1152/japplphysiol.00162.2014</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Farina, D.</string-name>
              <string-name>Merletti, R.</string-name>
              <string-name>Enoka, R.M.</string-name>
            </person-group>
            <year>2014</year>
            <article-title>The Extraction of Neural Strategies from the Surface EMG: An Update</article-title>
            <source>Journal of Applied Physiology</source>
            <volume>117</volume>
            <pub-id pub-id-type="doi">10.1152/japplphysiol.00162.2014</pub-id>
            <pub-id pub-id-type="pmid">25277737</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B2">
        <label>2.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Merletti, R. and Cerone, G.L. (2020) Tutorial. Surface EMG Detection, Conditioning and Pre-Processing: Best Practices. <italic>Journal</italic><italic>of</italic><italic>Electromyography</italic><italic>and</italic><italic>Kinesiology</italic>, 54, Article ID: 102440. https://doi.org/10.1016/j.jelekin.2020.102440 <pub-id pub-id-type="doi">10.1016/j.jelekin.2020.102440</pub-id><pub-id pub-id-type="pmid">32763743</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jelekin.2020.102440">https://doi.org/10.1016/j.jelekin.2020.102440</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Merletti, R.</string-name>
              <string-name>Cerone, G.L.</string-name>
              <string-name>Detection, C</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Tutorial</article-title>
            <source>Surface EMG Detection</source>
            <volume>54</volume>
            <fpage>102440</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jelekin.2020.102440</pub-id>
            <pub-id pub-id-type="pmid">32763743</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B3">
        <label>3.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Zhao, Y., Qian, K., Bo, S., Zhang, Z., Li, Z., Li, G., <italic>et al</italic>. (2023) Adaptive Cooperative Control Strategy for a Wrist Exoskeleton Using Model-Based Joint Impedance Estimation. <italic>IEEE</italic>/ <italic>ASME</italic><italic>Transactions</italic><italic>on</italic><italic>Mechatronics</italic>, 28, 748-757. https://doi.org/10.1109/tmech.2022.3211671 <pub-id pub-id-type="doi">10.1109/tmech.2022.3211671</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tmech.2022.3211671">https://doi.org/10.1109/tmech.2022.3211671</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Zhao, Y.</string-name>
              <string-name>Qian, K.</string-name>
              <string-name>Bo, S.</string-name>
              <string-name>Zhang, Z.</string-name>
              <string-name>Li, Z.</string-name>
              <string-name>Li, G.</string-name>
            </person-group>
            <year>2023</year>
            <article-title>Adaptive Cooperative Control Strategy for a Wrist Exoskeleton Using Model-Based Joint Impedance Estimation</article-title>
            <source>IEEE/ASME Transactions on Mechatronics</source>
            <volume>28</volume>
            <pub-id pub-id-type="doi">10.1109/tmech.2022.3211671</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B4">
        <label>4.</label>
        <citation-alternatives>
          <mixed-citation publication-type="confproc">Liu, G., Zhang, X., Sun, Q. and Dong, R. (2020) Multi-Joint Motor Intention Recognition of Lower Limbs Based on Muscle Synergies. 2020 10 <italic>th Institute of Electrical and Electronics Engineers International Conference on Cyber Technology in Automation</italic>, <italic>Control</italic>, <italic>and Intelligent Systems</italic> ( <italic>CYBER</italic>), Xi’an, 10-13 October 2020, 283-288. https://doi.org/10.1109/cyber50695.2020.9279175 <pub-id pub-id-type="doi">10.1109/cyber50695.2020.9279175</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/cyber50695.2020.9279175">https://doi.org/10.1109/cyber50695.2020.9279175</ext-link></mixed-citation>
          <element-citation publication-type="confproc">
            <person-group person-group-type="author">
              <string-name>Liu, G.</string-name>
              <string-name>Zhang, X.</string-name>
              <string-name>Sun, Q.</string-name>
              <string-name>Dong, R.</string-name>
              <string-name>Automation, C</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Multi-Joint Motor Intention Recognition of Lower Limbs Based on Muscle Synergies</article-title>
            <source>2020 10th Institute of Electrical and Electronics Engineers International Conference on Cyber Technology in Automation</source>
            <volume>10</volume>
            <pub-id pub-id-type="doi">10.1109/cyber50695.2020.9279175</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B5">
        <label>5.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Hussain, I., Salvietti, G., Spagnoletti, G. and Prattichizzo, D. (2016) The Soft-SixthFinger: A Wearable EMG Controlled Robotic Extra-Finger for Grasp Compensation in Chronic Stroke Patients. <italic>IEEE</italic><italic>Robotics</italic><italic>and</italic><italic>Automation</italic><italic>Letters</italic>, 1, 1000-1006. https://doi.org/10.1109/lra.2016.2530793 <pub-id pub-id-type="doi">10.1109/lra.2016.2530793</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/lra.2016.2530793">https://doi.org/10.1109/lra.2016.2530793</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Hussain, I.</string-name>
              <string-name>Salvietti, G.</string-name>
              <string-name>Spagnoletti, G.</string-name>
              <string-name>Prattichizzo, D.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>The Soft-SixthFinger: A Wearable EMG Controlled Robotic Extra-Finger for Grasp Compensation in Chronic Stroke Patients</article-title>
            <source>IEEE Robotics and Automation Letters</source>
            <volume>1</volume>
            <pub-id pub-id-type="doi">10.1109/lra.2016.2530793</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B6">
        <label>6.</label>
        <citation-alternatives>
          <mixed-citation publication-type="confproc">6. Shang, J., Fang, D., Luo, Z., Wang, G. and Li, Y. (2020) Design and Analysis of a Hydraulic Drive Downhole Traction in Pipe Robot Based on Flexible Support Structure. <italic>Proceedings of the Institution of Mechanical Engineers</italic>, <italic>Part C</italic>: <italic>Journal of Mechanical Engineering Science</italic>, 234, 1809-1820.</mixed-citation>
          <element-citation publication-type="confproc">
            <person-group person-group-type="author">
              <string-name>Shang, J.</string-name>
              <string-name>Fang, D.</string-name>
              <string-name>Luo, Z.</string-name>
              <string-name>Wang, G.</string-name>
              <string-name>Li, Y.</string-name>
              <string-name>Engineers, P</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Design and Analysis of a Hydraulic Drive Downhole Traction in Pipe Robot Based on Flexible Support Structure</article-title>
            <source>Proceedings of the Institution of Mechanical Engineers</source>
            <volume>234</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B7">
        <label>7.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Fang, D., Wang, J., Yang, M., Zhang, Y., Zhang, P. and Zhang, J. (2023) A Bionic Multi-Chamber Pneumatic Actuator for Powered Exoskeleton Based on Muscle Scale Mechanism. <italic>Robotica</italic>, 41, 3672-3686. https://doi.org/10.1017/s0263574723001224 <pub-id pub-id-type="doi">10.1017/s0263574723001224</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1017/s0263574723001224">https://doi.org/10.1017/s0263574723001224</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Fang, D.</string-name>
              <string-name>Wang, J.</string-name>
              <string-name>Yang, M.</string-name>
              <string-name>Zhang, Y.</string-name>
              <string-name>Zhang, P.</string-name>
              <string-name>Zhang, J.</string-name>
            </person-group>
            <year>2023</year>
            <article-title>A Bionic Multi-Chamber Pneumatic Actuator for Powered Exoskeleton Based on Muscle Scale Mechanism</article-title>
            <source>Robotica</source>
            <volume>41</volume>
            <pub-id pub-id-type="doi">10.1017/s0263574723001224</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B8">
        <label>8.</label>
        <citation-alternatives>
          <mixed-citation publication-type="web">World Health Organization (2023) Stroke: Key Facts. https://www.who.int/news-room/fact-sheets/detail/stroke</mixed-citation>
          <element-citation publication-type="web">
            <year>2023</year>
            <article-title>Stroke: Key Facts</article-title>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B9">
        <label>9.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Kutner, N.G., Zhang, R., Butler, A.J., Wolf, S.L. and Alberts, J.L. (2010) Quality-of-Life Change Associated with Robotic-Assisted Therapy to Improve Hand Motor Function in Patients with Subacute Stroke: A Randomized Clinical Trial. <italic>Physical</italic><italic>Therapy</italic>, 90, 493-504. https://doi.org/10.2522/ptj.20090160 <pub-id pub-id-type="doi">10.2522/ptj.20090160</pub-id><pub-id pub-id-type="pmid">20185616</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2522/ptj.20090160">https://doi.org/10.2522/ptj.20090160</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Kutner, N.G.</string-name>
              <string-name>Zhang, R.</string-name>
              <string-name>Butler, A.J.</string-name>
              <string-name>Wolf, S.L.</string-name>
              <string-name>Alberts, J.L.</string-name>
            </person-group>
            <year>2010</year>
            <article-title>Quality-of-Life Change Associated with Robotic-Assisted Therapy to Improve Hand Motor Function in Patients with Subacute Stroke: A Randomized Clinical Trial</article-title>
            <source>Physical Therapy</source>
            <volume>90</volume>
            <pub-id pub-id-type="doi">10.2522/ptj.20090160</pub-id>
            <pub-id pub-id-type="pmid">20185616</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B10">
        <label>10.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Li, J., Wang, S., Wang, J., Zheng, R., Zhang, Y. and Chen, Z. (2012) Development of a Hand Exoskeleton System for Index Finger Rehabilitation. <italic>Chinese</italic><italic>Journal</italic><italic>of</italic><italic>Mechanical</italic><italic>Engineering</italic>, 25, 223-233. https://doi.org/10.3901/cjme.2012.02.223 <pub-id pub-id-type="doi">10.3901/cjme.2012.02.223</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3901/cjme.2012.02.223">https://doi.org/10.3901/cjme.2012.02.223</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Li, J.</string-name>
              <string-name>Wang, S.</string-name>
              <string-name>Wang, J.</string-name>
              <string-name>Zheng, R.</string-name>
              <string-name>Zhang, Y.</string-name>
              <string-name>Chen, Z.</string-name>
            </person-group>
            <year>2012</year>
            <article-title>Development of a Hand Exoskeleton System for Index Finger Rehabilitation</article-title>
            <source>Chinese Journal of Mechanical Engineering</source>
            <volume>25</volume>
            <pub-id pub-id-type="doi">10.3901/cjme.2012.02.223</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B11">
        <label>11.</label>
        <citation-alternatives>
          <mixed-citation publication-type="confproc">Prattichizzo, D., Malvezzi, M., Hussain, I. and Salvietti, G. (2014) The Sixth-Finger: A Modular Extra-Finger to Enhance Human Hand Capabilities. <italic>The</italic> 23 <italic>rd IEEE International Symposium on Robot and Human Interactive Communication</italic>, Edinburgh, 25-29 August 2014, 993-998. https://doi.org/10.1109/roman.2014.6926382 <pub-id pub-id-type="doi">10.1109/roman.2014.6926382</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/roman.2014.6926382">https://doi.org/10.1109/roman.2014.6926382</ext-link></mixed-citation>
          <element-citation publication-type="confproc">
            <person-group person-group-type="author">
              <string-name>Prattichizzo, D.</string-name>
              <string-name>Malvezzi, M.</string-name>
              <string-name>Hussain, I.</string-name>
              <string-name>Salvietti, G.</string-name>
              <string-name>Communication, E</string-name>
            </person-group>
            <year>2014</year>
            <article-title>The Sixth-Finger: A Modular Extra-Finger to Enhance Human Hand Capabilities</article-title>
            <source>The 23rd IEEE International Symposium on Robot and Human Interactive Communication</source>
            <volume>25</volume>
            <pub-id pub-id-type="doi">10.1109/roman.2014.6926382</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B12">
        <label>12.</label>
        <citation-alternatives>
          <mixed-citation publication-type="web">Gasser, H.S. and Erlanger, J. (1944) Nobel Lecture: The Conduction of Impulses in Nerve Fibers. Nobel Foundation. https://www.nobelprize.org/prizes/medicine/1944/erlanger/lecture/</mixed-citation>
          <element-citation publication-type="web">
            <person-group person-group-type="author">
              <string-name>Gasser, H.S.</string-name>
              <string-name>Erlanger, J.</string-name>
            </person-group>
            <year>1944</year>
            <article-title>Nobel Lecture: The Conduction of Impulses in Nerve Fibers</article-title>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B13">
        <label>13.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Khan, B.A., Usmani, A.R., Athar, S., Hashmi, A., Farooq, O. and Muzammil, M. (2021) EEG-Based Exoskeleton for Rehabilitation Therapy. In: Muzammil, M., Khan, A.A. and Hasan, F., Eds., <italic>Ergonomics for Improved Productivity</italic>, Springer, 645-653. https://doi.org/10.1007/978-981-15-9054-2_75 <pub-id pub-id-type="doi">10.1007/978-981-15-9054-2_75</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/978-981-15-9054-2_75">https://doi.org/10.1007/978-981-15-9054-2_75</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Khan, B.A.</string-name>
              <string-name>Usmani, A.R.</string-name>
              <string-name>Athar, S.</string-name>
              <string-name>Hashmi, A.</string-name>
              <string-name>Farooq, O.</string-name>
              <string-name>Muzammil, M.</string-name>
              <string-name>Muzammil, M.</string-name>
              <string-name>Khan, A.A.</string-name>
              <string-name>Hasan, F.</string-name>
              <string-name>Productivity, S</string-name>
            </person-group>
            <year>2021</year>
            <article-title>EEG-Based Exoskeleton for Rehabilitation Therapy</article-title>
            <source>In: Muzammil</source>
            <volume>645</volume>
            <pub-id pub-id-type="doi">10.1007/978-981-15-9054-2_75</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B14">
        <label>14.</label>
        <citation-alternatives>
          <mixed-citation publication-type="confproc">Zhang, C., Ru, H., Yang, Z. and Huang, J. (2022) A Novel Wearable Pneumatic Flexible Supernumerary Robotic Limb for Grasping Compensation. 2022 41 <italic>st Chinese Control Conference</italic> ( <italic>CCC</italic>), Hefei, 25-27 July 2022, 3865-3870. https://doi.org/10.23919/ccc55666.2022.9902289 <pub-id pub-id-type="doi">10.23919/ccc55666.2022.9902289</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.23919/ccc55666.2022.9902289">https://doi.org/10.23919/ccc55666.2022.9902289</ext-link></mixed-citation>
          <element-citation publication-type="confproc">
            <person-group person-group-type="author">
              <string-name>Zhang, C.</string-name>
              <string-name>Ru, H.</string-name>
              <string-name>Yang, Z.</string-name>
              <string-name>Huang, J.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>A Novel Wearable Pneumatic Flexible Supernumerary Robotic Limb for Grasping Compensation</article-title>
            <source>2022 41st Chinese Control Conference (CCC)</source>
            <volume>25</volume>
            <pub-id pub-id-type="doi">10.23919/ccc55666.2022.9902289</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B15">
        <label>15.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Heo, P., Gu, G.M., Lee, S., Rhee, K. and Kim, J. (2012) Current Hand Exoskeleton Technologies for Rehabilitation and Assistive Engineering. <italic>International</italic><italic>Journal</italic><italic>of</italic><italic>Precision</italic><italic>Engineering</italic><italic>and</italic><italic>Manufacturing</italic>, 13, 807-824. https://doi.org/10.1007/s12541-012-0107-2 <pub-id pub-id-type="doi">10.1007/s12541-012-0107-2</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12541-012-0107-2">https://doi.org/10.1007/s12541-012-0107-2</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Heo, P.</string-name>
              <string-name>Gu, G.M.</string-name>
              <string-name>Lee, S.</string-name>
              <string-name>Rhee, K.</string-name>
              <string-name>Kim, J.</string-name>
            </person-group>
            <year>2012</year>
            <article-title>Current Hand Exoskeleton Technologies for Rehabilitation and Assistive Engineering</article-title>
            <source>International Journal of Precision Engineering and Manufacturing</source>
            <volume>13</volume>
            <pub-id pub-id-type="doi">10.1007/s12541-012-0107-2</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B16">
        <label>16.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Wan, X., <italic>et al</italic>. (2012) Design of a Multi-Channel sEMG Signal Acquisition System Based on LabVIEW. <italic>Application of Electronic Technique</italic>, 38, 78-81.</mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Wan, X.</string-name>
            </person-group>
            <year>2012</year>
            <article-title>Design of a Multi-Channel sEMG Signal Acquisition System Based on LabVIEW</article-title>
            <source>Application of Electronic Technique</source>
            <volume>38</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B17">
        <label>17.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Yang, B., Huang, J., Chen, X., Xiong, C. and Hasegawa, Y. (2021) Supernumerary Robotic Limbs: A Review and Future Outlook. <italic>IEEE</italic><italic>Transactions</italic><italic>on</italic><italic>Medical</italic><italic>Robotics</italic><italic>and</italic><italic>Bionics</italic>, 3, 623-639. https://doi.org/10.1109/tmrb.2021.3086016 <pub-id pub-id-type="doi">10.1109/tmrb.2021.3086016</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tmrb.2021.3086016">https://doi.org/10.1109/tmrb.2021.3086016</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Yang, B.</string-name>
              <string-name>Huang, J.</string-name>
              <string-name>Chen, X.</string-name>
              <string-name>Xiong, C.</string-name>
              <string-name>Hasegawa, Y.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Supernumerary Robotic Limbs: A Review and Future Outlook</article-title>
            <source>IEEE Transactions on Medical Robotics and Bionics</source>
            <volume>3</volume>
            <pub-id pub-id-type="doi">10.1109/tmrb.2021.3086016</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B18">
        <label>18.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Napier, J.R. (1956) The Prehensile Movements of the Human Hand. <italic>The</italic><italic>Journal</italic><italic>of</italic><italic>Bone</italic><italic>and</italic><italic>Joint</italic><italic>Surgery</italic>. <italic>British</italic><italic>Volume</italic>, 38, 902-913. https://doi.org/10.1302/0301-620x.38b4.902 <pub-id pub-id-type="doi">10.1302/0301-620x.38b4.902</pub-id><pub-id pub-id-type="pmid">13376678</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1302/0301-620x.38b4.902">https://doi.org/10.1302/0301-620x.38b4.902</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Napier, J.R.</string-name>
            </person-group>
            <year>1956</year>
            <article-title>The Prehensile Movements of the Human Hand</article-title>
            <source>The Journal of Bone and Joint Surgery. British Volume</source>
            <volume>38</volume>
            <pub-id pub-id-type="doi">10.1302/0301-620x.38b4.902</pub-id>
            <pub-id pub-id-type="pmid">13376678</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B19">
        <label>19.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Song, J., Zhu, A., <italic>et al</italic>. (2023) A Multijoint Passive Elastic Spine Exoskeleton for Stoop Lifting Assistance. <italic>IEEE</italic>/ <italic>ASME Transactions on Mechatronics</italic>, 28, 1400-1410.</mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Song, J.</string-name>
              <string-name>Zhu, A.</string-name>
            </person-group>
            <year>2023</year>
            <article-title>A Multijoint Passive Elastic Spine Exoskeleton for Stoop Lifting Assistance</article-title>
            <source>IEEE/ASME Transactions on Mechatronics</source>
            <volume>28</volume>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B20">
        <label>20.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Jones, B.A. and Walker, I.D. (2006) Kinematics for Multisection Continuum Robots. <italic>IEEE</italic><italic>Transactions</italic><italic>on</italic><italic>Robotics</italic>, 22, 43-55. https://doi.org/10.1109/tro.2005.861458 <pub-id pub-id-type="doi">10.1109/tro.2005.861458</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tro.2005.861458">https://doi.org/10.1109/tro.2005.861458</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Jones, B.A.</string-name>
              <string-name>Walker, I.D.</string-name>
            </person-group>
            <year>2006</year>
            <article-title>Kinematics for Multisection Continuum Robots</article-title>
            <source>IEEE Transactions on Robotics</source>
            <volume>22</volume>
            <pub-id pub-id-type="doi">10.1109/tro.2005.861458</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B21">
        <label>21.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Fang, D., Shang, J., Luo, Z., Lv, P. and Wu, G. (2018) Development of a Novel Self-Locking Mechanism for Continuous Propulsion Inchworm In-Pipe Robot. <italic>Advances</italic><italic>in</italic><italic>Mechanical</italic><italic>Engineering</italic>, 10, 1-11. https://doi.org/10.1177/1687814017749402 <pub-id pub-id-type="doi">10.1177/1687814017749402</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1177/1687814017749402">https://doi.org/10.1177/1687814017749402</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Fang, D.</string-name>
              <string-name>Shang, J.</string-name>
              <string-name>Luo, Z.</string-name>
              <string-name>Lv, P.</string-name>
              <string-name>Wu, G.</string-name>
            </person-group>
            <year>2018</year>
            <article-title>Development of a Novel Self-Locking Mechanism for Continuous Propulsion Inchworm In-Pipe Robot</article-title>
            <source>Advances in Mechanical Engineering</source>
            <volume>10</volume>
            <pub-id pub-id-type="doi">10.1177/1687814017749402</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B22">
        <label>22.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Webster, R.J. and Jones, B.A. (2010) Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review. <italic>The</italic><italic>International</italic><italic>Journal</italic><italic>of</italic><italic>Robotics</italic><italic>Research</italic>, 29, 1661-1683. https://doi.org/10.1177/0278364910368147 <pub-id pub-id-type="doi">10.1177/0278364910368147</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1177/0278364910368147">https://doi.org/10.1177/0278364910368147</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Webster, R.J.</string-name>
              <string-name>Jones, B.A.</string-name>
            </person-group>
            <year>2010</year>
            <article-title>Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review</article-title>
            <source>The International Journal of Robotics Research</source>
            <volume>29</volume>
            <pub-id pub-id-type="doi">10.1177/0278364910368147</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B23">
        <label>23.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Xu, L. (2022) Separable Multi-Innovation Newton Iterative Modeling Algorithm for Multi-Frequency Signals Based on the Sliding Measurement Window. <italic>Circuits</italic>, <italic>Systems</italic>, <italic>and</italic><italic>Signal</italic><italic>Processing</italic>, 41, 805-830. https://doi.org/10.1007/s00034-021-01801-x <pub-id pub-id-type="doi">10.1007/s00034-021-01801-x</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s00034-021-01801-x">https://doi.org/10.1007/s00034-021-01801-x</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Xu, L.</string-name>
              <string-name>Circuits, S</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Separable Multi-Innovation Newton Iterative Modeling Algorithm for Multi-Frequency Signals Based on the Sliding Measurement Window</article-title>
            <source>Circuits</source>
            <volume>41</volume>
            <pub-id pub-id-type="doi">10.1007/s00034-021-01801-x</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B24">
        <label>24.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Sharma, A., Shrivas, N.V. and Sharma, I. (2025) An Adaptive Segmentation Scheme Based on Recurring Action Potentials for sEMG Controlled Movement Decoding. <italic>Physical</italic><italic>and</italic><italic>Engineering</italic><italic>Sciences</italic><italic>in</italic><italic>Medicine</italic>, 48, 881-901. https://doi.org/10.1007/s13246-025-01557-7 <pub-id pub-id-type="doi">10.1007/s13246-025-01557-7</pub-id><pub-id pub-id-type="pmid">40327236</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s13246-025-01557-7">https://doi.org/10.1007/s13246-025-01557-7</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Sharma, A.</string-name>
              <string-name>Shrivas, N.V.</string-name>
              <string-name>Sharma, I.</string-name>
            </person-group>
            <year>2025</year>
            <article-title>An Adaptive Segmentation Scheme Based on Recurring Action Potentials for sEMG Controlled Movement Decoding</article-title>
            <source>Physical and Engineering Sciences in Medicine</source>
            <volume>48</volume>
            <pub-id pub-id-type="doi">10.1007/s13246-025-01557-7</pub-id>
            <pub-id pub-id-type="pmid">40327236</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
    </ref-list>
  </back>
</article>