<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN" "JATS-journalpublishing1-4.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.4" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">jbise</journal-id>
      <journal-title-group>
        <journal-title>Journal of Biomedical Science and Engineering</journal-title>
      </journal-title-group>
      <issn pub-type="epub">1937-688X</issn>
      <issn pub-type="ppub">1937-6871</issn>
      <publisher>
        <publisher-name>Scientific Research Publishing</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.4236/jbise.2026.196019</article-id>
      <article-id pub-id-type="publisher-id">jbise-152073</article-id>
      <article-categories>
        <subj-group>
          <subject>Article</subject>
        </subj-group>
        <subj-group>
          <subject>Biomedical</subject>
          <subject>Life Sciences</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Numerical Simulation of the Mitral Valve Repair</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Pigeon</surname>
            <given-names>Tévy Julie</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Kulisa</surname>
            <given-names>Pascale</given-names>
          </name>
          <xref ref-type="aff" rid="aff2">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Morestin</surname>
            <given-names>Fabrice</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name name-style="western">
            <surname>Bou-Saïd</surname>
            <given-names>Benyebka</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="aff1"><label>1</label> INSA Lyon, CNRS, LaMCoS, Villeurbanne, France </aff>
      <aff id="aff2"><label>2</label> Univ Lyon, INSA Lyon, Ecole Centrale de Lyon, Claude Bernard Univ Lyon 1, CNRS, LMFA, Villeurbanne, France </aff>
      <author-notes>
        <fn fn-type="conflict" id="fn-conflict">
          <p>The authors declare no conflicts of interest regarding the publication of this paper.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub">
        <day>15</day>
        <month>06</month>
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="collection">
        <month>06</month>
        <year>2026</year>
      </pub-date>
      <volume>19</volume>
      <issue>06</issue>
      <fpage>227</fpage>
      <lpage>241</lpage>
      <history>
        <date date-type="received">
          <day>
          </day>
          <month>
          </month>
          <year>
          </year>
        </date>
        <date date-type="accepted">
          <day>
          </day>
          <month>
          </month>
          <year>
          </year>
        </date>
        <date date-type="published">
          <day>15</day>
          <month>06</month>
          <year>2026</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2026 by the authors and Scientific Research Publishing Inc.</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="open-access">
          <license-p> This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link> ). </license-p>
        </license>
      </permissions>
      <self-uri content-type="doi" xlink:href="https://doi.org/10.4236/jbise.2026.196019">https://doi.org/10.4236/jbise.2026.196019</self-uri>
      <abstract>
        <p>This paper presents a customizable finite element framework of the mitral valve and surrounding structures for the numerical study of transcatheter annuloplasty. The geometry used in this work corresponds to a single reference left-heart model provided by KIT and was preprocessed using CAD tools. The present study focuses on the mechanical response of the valve region during prosthetic ring positioning and annular downsizing. In the complete annuloplasty model, prosthesis positioning and downsizing were completed sequentially in Abaqus. Because severe mesh distortion prevented completion of physiological loading after downsizing in the prosthesis-including model, ventricular contraction and pressure loading were implemented in a separate “Physio” configuration without the prosthesis. The resulting deformation and stress patterns are consistent with previously reported computational trends, with elevated stresses in the atrioventricular-junction region near the fibrous trigones and posterior annular region. The model should therefore be considered a methodological framework and proof of concept, rather than a fully validated patient-specific planning tool. Future work will focus on mesh convergence, experimental validation, and reintegration of physiological loading into the complete annuloplasty model.</p>
      </abstract>
      <kwd-group kwd-group-type="author-generated" xml:lang="en">
        <kwd>Annuloplasty Device</kwd>
        <kwd>Biomechanics</kwd>
        <kwd>Finite Element Method</kwd>
        <kwd>Native Annulus</kwd>
        <kwd>Percutaneous Surgery</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>1. Introduction</title>
      <sec id="sec1dot1">
        <title>1.1. Clinical Context</title>
        <p>Cardiovascular disease remains the leading cause of death worldwide, accounting for 31% of all global deaths. Mitral regurgitation (MR) is the second most prevalent valve disorder in Europe, affecting 2% of the global population [[<xref ref-type="bibr" rid="B1">1</xref>]]. This pathology is characterized by an enlargement of the mitral valve (MV) diameter, which compromises the coaptation of the leaflets during systole. Consequently, a leak in the valve allows retrograde blood flow from the left ventricle into the left atrium. First introduced by Alain Carpentier in 1983 [[<xref ref-type="bibr" rid="B2">2</xref>]], annuloplasty is a surgical technique aimed at reducing the mitral valve’s diameter and stabilizing the repair through the implantation of a prosthetic ring. This ring is anchored to the native annulus using nitinol threads or surgical anchors. Despite being regarded as the gold standard for the surgical repair of pathological valve [[<xref ref-type="bibr" rid="B3">3</xref>]], open-heart annuloplasty remains a highly invasive procedure, often unsuitable for high-risk patients. In contrast, transcatheter techniques, considered minimally invasive, allow surgeons to operate internally without halting cardiac function [[<xref ref-type="bibr" rid="B4">4</xref>]]. One such approach, MitraClip<sup>®</sup>, addresses MR by clamping the leaflets together. Our study focuses on transcatheter annuloplasty, with particular attention to prosthetic durability. The Cardioband<sup>®</sup> is another minimally invasive annuloplasty device. It features a flexible anchoring system that accommodates various mitral annulus geometries [[<xref ref-type="bibr" rid="B5">5</xref>]]. Parametric and numerical simulations of the Cardioband on patient-specific anatomies [[<xref ref-type="bibr" rid="B6">6</xref>]], along with experimental campaigns on anchor dehiscence [[<xref ref-type="bibr" rid="B7">7</xref>]], have been conducted. Nevertheless, despite obtaining CE certification, the device has not achieved widespread success [[<xref ref-type="bibr" rid="B8">8</xref>]].</p>
      </sec>
      <sec id="sec1dot2">
        <title>1.2. A Personalized Model</title>
        <p>The leading cause of short-term failure and subsequent re-operation following annuloplasty is anchor dehiscence [[<xref ref-type="bibr" rid="B3">3</xref>]]. The mechanical and hemodynamic stresses exerted on the system, the healing process at the anchor sites, the local collagen density [[<xref ref-type="bibr" rid="B3">3</xref>], [<xref ref-type="bibr" rid="B9">9</xref>]], and the mechanical properties of the prosthesis: all influence this failure mode. These factors vary significantly among patients. Therefore, a personalized, patient-specific numerical model is essential to simulate the procedure virtually and determine optimal anchoring parameters such as location, orientation, and quantity tailored to the patient’s valve anatomy.</p>
      </sec>
      <sec id="sec1dot3">
        <title>1.3. Study Objectives</title>
        <p>Our objective is to develop a digital twin of the mitral valve and surrounding structures to support patient-specific prosthetic ring design. The first phase involves a finite element model to assess tissue stress after anchor implantation. Later phases will incorporate growth, remodeling, and fatigue to evaluate long-term prosthesis viability. A finite element approach was selected to address this solid mechanics problem. The present work is intended as a methodological step toward patient-tailored annuloplasty simulation. Its main contribution is the construction of a continuous atrio-ventriculo-valvular finite element geometry coupled with an idealized annuloplasty ring and discrete anchoring regions, allowing stress localization to be assessed during prosthesis positioning and downsizing. At this stage, the framework is not presented as a validated clinical prediction tool; rather, it provides a basis for future mesh refinement, experimental validation, and patient-specific adaptation.</p>
      </sec>
    </sec>
    <sec id="sec2">
      <title>2. State of Art</title>
      <sec id="sec2dot1">
        <title>2.1. Functional Anatomy of the Mitral Valve</title>
        <p>The mitral annulus is essential for annuloplasty implantation, providing structural stability at the junction of the left atrium, left ventricle, and mitral leaflets. It is composed of discontinuous fibrous tissues with variable thickness and density, although its anatomy and mechanics remain incompletely understood [[<xref ref-type="bibr" rid="B10">10</xref>]], [[<xref ref-type="bibr" rid="B11">11</xref>]]. Anteriorly, it forms part of the heart’s fibrous skeleton, with the fibrous trigones serving as key anchoring points for the first and last prosthetic sutures [[<xref ref-type="bibr" rid="B12">12</xref>]]. Posteriorly, the annulus is less well defined and may coincide with the atrioventricular junction, merge with the leaflet hinge, lie slightly below it, or be nearly absent; histologically, it includes muscular, fibrous, and adipose tissue [[<xref ref-type="bibr" rid="B10">10</xref>]]. The mitral valve is also supported by papillary muscles and chordae tendineae, which prevent leaflet prolapse into the left atrium during systole [[<xref ref-type="bibr" rid="B13">13</xref>]].</p>
      </sec>
      <sec id="sec2dot2">
        <title>2.2. Previous Numerical Models</title>
        <p>Over the past 15 years, computational models have significantly advanced the understanding of left heart and mitral valve biomechanics. </p>
        <p>Wong <italic>et al.</italic> [[<xref ref-type="bibr" rid="B14">14</xref>]] extended the work of Wenk <italic>et al.</italic> [[<xref ref-type="bibr" rid="B15">15</xref>]] by incorporating annuloplasty into their model of an infarcted left ventricle, with valve leaflets reconstructed from B-spline curves fitted to points derived from magnetic resonance images and a mitral annulus defined by 12 points along the valve perimeter.</p>
        <p>Similarly, Kong <italic>et al.</italic> [[<xref ref-type="bibr" rid="B16">16</xref>]] developed an infarcted left ventricular model with leaflets reconstructed from multi-slice CT images. They analyzed the effect of a prosthetic ring on leaflet coaptation and chordae tendineae tension following papillary muscle relocation.</p>
        <p>Gao [[<xref ref-type="bibr" rid="B17">17</xref>]] developed a comprehensive FSI model of the mitral valve, incorporating a simplified atrium, ventricle, and aortic outflow. Valve geometry was reconstructed from cine MRI, and fibrous structures were modelled using biomarker-segmented features and fiber-reinforced constitutive laws. </p>
        <p>Rausch <italic>et al.</italic> [[<xref ref-type="bibr" rid="B18">18</xref>]], using an extended Living Heart Model [[<xref ref-type="bibr" rid="B19">19</xref>]], simulated annuloplasty with 14 sutures. The geometry was derived from Zygote<sup>®</sup> models and meshed with linear tetrahedral elements. This study quantified stress and strain changes and identified maximal stretch regions near the aorto-mitral junction and posterolateral annulus.</p>
      </sec>
      <sec id="sec2dot3">
        <title>2.3. Limitations of Existing Studies</title>
        <p>Most existing models either oversimplify or omit the mitral annular region, often representing it only through the leaflet-ventricle interface. In the present model, the anatomical annulus is not segmented as a separate material domain. Instead, the annular region is defined operationally as the atrioventricular junction, corresponding to the continuous transition between the leaflets, atrial base, and ventricular inlet. Therefore, stress values reported in this region should be interpreted as stresses in the annular/junctional region, not as stresses in a separately modeled histological annulus.</p>
      </sec>
    </sec>
    <sec id="sec3">
      <title>3. Material and Methods</title>
      <sec id="sec3dot1">
        <title>3.1. Geometric Reconstruction of the Mitral Valve</title>
        <p>The mitral valve and surrounding left-heart geometry used in this study correspond to a single reference anatomical model provided by the Computational Cardiac Modeling group at the Karlsruhe Institute of Technology. The initial segmentation had been performed by an external provider before transfer to the authors. Consequently, the original imaging modality, acquisition parameters, and subject-level metadata were not available to the authors. The model should therefore be regarded as a customizable finite element framework based on one reference anatomy, rather than a fully documented patient-specific model. The reconstructed geometry includes the mitral leaflets, the lower portion of the left atrial cavity, the upper section of the left ventricle, and part of the aortic outflow tract (see <xref ref-type="fig" rid="fig1">Figure 1</xref>).</p>
        <fig id="fig1">
          <label>Figure 1</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId11.jpeg?20260625090637" />
        </fig>
        <p><bold>Figure 1.</bold><bold>Parallel between th</bold><bold>e biological mitral valve and the numerical model geometries. Three actors are crucial to model the annuloplasty: the biological tissue (atrium, ventricle, leaflets, in green), the prosthetic ring (blue) and the fixation points (red).</bold></p>
        <p>The prosthetic ring used in this study was based on the Carpentier-Edwards Physio Annuloplasty Ring. It was recreated in Creo Parametric from the 2009 Carpentier patent. A 36-mm ring, with major and minor axes of 36 mm and 25.5 mm and a 3-mm cross-sectional diameter, was modeled to fit the valve geometry (see <xref ref-type="fig" rid="fig2">Figure 2</xref>). Anchors were represented by 14 circular surfaces of 1-mm radius, evenly distributed along the ring’s free edges and oriented toward the valve wall: parallel, perpendicular, or at 45˚ to the horizontal plane. The first and last anchors were aligned with the fibrous trigones.</p>
        <fig id="fig2">
          <label>Figure 2</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId12.jpeg?20260625090637" />
        </fig>
        <p><bold>Figure 2.</bold><bold>Bottom view</bold><bold>of the prosthetic ring (blue) and 14 oriented anchors (yellow). (A) Long axis, (B) minor axis.</bold></p>
      </sec>
      <sec id="sec3dot2">
        <title>3.2. Hypothesis</title>
        <p>The myocardium is fibrous and strongly anisotropic, but for simplicity it is modeled here as an isotropic hyperelastic Neo-Hookean material rather than with a more complex orthotropic law [[<xref ref-type="bibr" rid="B20">20</xref>]].Only passive myocardial behavior is modeled explicitly; active contraction is applied through displacement boundary conditions.Hemodynamic loading includes static pressure and wall shear stress, but CFD simulations showed that static pressure contributes about five orders of magnitude more to valve and ventricular stress. Therefore, only static pressure is retained. The CFD simulations were performed in OpenFOAM, an open-source CFD software. </p>
      </sec>
      <sec id="sec3dot3">
        <title>3.3. Finite Element Model</title>
        <p>This problem of solid mechanics is solved by means of the Finite Elements Method with the commercial code Abaqus 2019 (v16.11.20).</p>
        <p>3.3.1. Resolution Scheme, Convergence and Computational Cost</p>
        <p>An implicit quasi-static solver was used to obtain accurate peak-systolic stresses, including geometric non-linearities and parallel computation on five CPUs. Each simulation took about one hour.</p>
        <p>The mitral valve was meshed with 5 mm quadratic tetrahedral elements, and the prosthesis with similar elements of about 1 mm. The full model contained 79,598 elements and 146,104 nodes.</p>
        <p>Because of the valve’s geometric complexity, a finer mesh could not be generated, so all simulations used a single mesh. A mesh-convergence study will be needed to optimize the balance between accuracy and computational cost.</p>
        <p>3.3.2. Workflow</p>
        <p>The numerical workflow was divided into two parts. First, the complete annuloplasty model including the prosthetic ring was used to simulate prosthesis positioning and annular downsizing. Second, because severe mesh distortion prevented physiological loading from being completed after downsizing in the prosthesis-including model, a separate “Physio” configuration without the prosthesis was used to demonstrate ventricular contraction and pressure loading.</p>
        <p>• Step 1: Prosthesis positioning by prescribed vertical displacement until contact with the tissue was achieved.</p>
        <p>• Step 2: Annular downsizing using the deformed geometry and stress field from Step 1, with tie constraints at the anchoring regions. Prosthesis diameter reduction pilots the native annulus diameter reduction. </p>
        <p>• Separate Physio configuration: ventricular contraction and hemodynamic pressure loading without the prosthesis.</p>
        <p>Considering the fact that the atrium remains fixed during the systolic phase, a fixed boundary condition is defined on the top surface of the model. </p>
        <p><bold>Step 1: Prosthetic Ring Implantation (MEP)</bold></p>
        <p>The ring is aligned and pressed against the valve tissue using a prescribed vertical displacement. The resulting geometry is then used for the next phase. For methodological development, vertical springs of 2200 N/m connect leaflet free-edge nodes to the ground. Contact is modeled using general contact with hard normal behavior and defined tangential properties.</p>
        <p><bold>Step 2: Annular Downsizing</bold></p>
        <p>Surgeons recommend reducing the diameter by 30% to restore valve competence. For the 36-mm ring used here, the imposed 12-mm diameter reduction corresponds to approximately 33% downsizing, close to the clinically targeted order of 30%. This was implemented as a 6-mm radial displacement of the prosthesis</p>
        <p>A tie constraint was imposed between the prosthetic anchoring surfaces and the atrial cavity, binding valve nodes to prosthesis ones. This reflects the relative stiffness—biological tissue is assumed to deform more than the prosthesis.</p>
        <p>The same general contact definition was applied everywhere except at the anchor points.</p>
        <p><bold>Step 3: Post-Surgical Loads</bold><bold>—</bold><bold>Ventricular Contraction and Hemodynamic Pressure</bold></p>
        <p>Severe mesh distortion after downsizing prevented completion of the simulation. An alternative “Physio” model was therefore built from the end of the MEP step, including ventricular contraction and pressure loading but excluding the prosthesis.</p>
        <p>Since the mitral valve diameter decreases by about 6 mm during systole [[<xref ref-type="bibr" rid="B21">21</xref>], [<xref ref-type="bibr" rid="B22">22</xref>]], ventricular contraction was modeled as a 3 mm radial displacement at the ventricular base. Tendinous chords were represented by 2200 N/m springs [[<xref ref-type="bibr" rid="B23">23</xref>], [<xref ref-type="bibr" rid="B24">24</xref>]] connecting leaflet free edges to two reference points below the valve, corresponding to papillary muscle tips.</p>
        <p>Because CFD showed wall shear stress is negligible compared with static pressure near the mitral valve [[<xref ref-type="bibr" rid="B25">25</xref>]], only pressure loading was applied: 16 kPa (120 mmHg) on the ventricular wall and leaflet underside [[<xref ref-type="bibr" rid="B13">13</xref>]], and 3333 Pa (25 mmHg) near the aortic valve to represent right ventricular pressure. Maximum systolic pressure was used to estimate upper-bound stress [[<xref ref-type="bibr" rid="B26">26</xref>]]. As left and right ventricular contraction are nearly synchronous [[<xref ref-type="bibr" rid="B27">27</xref>]], both pressures were applied simultaneously. A fixed boundary condition was added at the valve base for stability. </p>
        <p>3.3.3. Constitutive Laws</p>
        <p>Because the native mitral annulus has a heterogeneous structure and variable collagen content [[<xref ref-type="bibr" rid="B10">10</xref>]], its mechanical behavior is difficult to define. To obtain a conservative estimate, the same Neo-Hookean myocardial parameters were assigned to all biological tissue domains included in the finite element mesh: the lower atrial wall, the upper ventricular wall, the aortic outflow region, the anterior and posterior mitral leaflets, and the atrioventricular junction/annular region. No separate material law was assigned to the annulus or to the leaflets, and no regional fiber orientation was introduced at this stage. This choice was made to obtain a conservative first-order estimate of stress localization, but the resulting stress magnitudes should not be interpreted as definitive tissue failure values. The Neo-Hookean constitutive model uses parameters from existing literature: density 1265 kg/m<sup>3</sup> [[<xref ref-type="bibr" rid="B28">28</xref>]], systolic Young’s modulus 300 kPa [[<xref ref-type="bibr" rid="B29">29</xref>]], and Poisson’s ratio 0.45 [[<xref ref-type="bibr" rid="B30">30</xref>]]. </p>
        <p>The prosthetic ring properties were identified by reproducing the Carpentier-Edwards Physio ring compression test in Abaqus [[<xref ref-type="bibr" rid="B31">31</xref>]]. The ring was assumed quasi-incompressible, with density 2300 kg/m<sup>3</sup>, Young’s modulus 1.785 MPa, and Poisson’s ratio 0.45.</p>
      </sec>
    </sec>
    <sec id="sec4">
      <title>4. Results</title>
      <sec id="sec4dot1">
        <title>4.1. Tissue Deformation Pre- and Post-Surgery</title>
        <p>The simulation shows mitral valve deformation caused by prosthetic ring implantation and tightening (see <xref ref-type="fig" rid="fig3">Figure 3</xref>, <xref ref-type="fig" rid="fig4">Figure 4</xref> and <bold>Table 1</bold>). Before the procedure, the annulus is irregular and dilated; after annuloplasty, it becomes more compact due to radial displacement and tissue anchoring. The largest local deformations occur near the anchor sites, where the device imposes the strongest constraints. </p>
        <fig id="fig3">
          <label>Figure 3</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId13.jpeg?20260625090640" />
        </fig>
        <p><bold>Figure 3.</bold><bold>Geometrical top view of the implanted ring on the mitral valve, before (left) and after (right) the annuloplasty procedure.</bold></p>
        <fig id="fig4">
          <label>Figure 4</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId14.jpeg?20260625090640" />
        </fig>
        <p><bold>Figure 4.</bold><bold>Septal-lateral (SL) distance (left) and commissural-commissural (CC) distance (right) reported between four nodes located on the mitral valve model.</bold></p>
        <p><bold>Table 1.</bold><bold>The</bold><bold>septo</bold><bold>-lateral (SL) and commissural-commissural (CC) distances before the downsizing.</bold></p>
        <table-wrap id="tbl1">
          <label>Table 1</label>
          <table>
            <tbody>
              <tr>
                <td>
                </td>
                <td>Preoperative</td>
                <td>Postoperative</td>
                <td>Reduction</td>
                <td>Reduction (%)</td>
              </tr>
              <tr>
                <td>SL distance [mm]</td>
                <td>29.2</td>
                <td>24.9</td>
                <td>4.3</td>
                <td>15%</td>
              </tr>
              <tr>
                <td>CC distance [mm]</td>
                <td>28.6</td>
                <td>22.9</td>
                <td>5.7</td>
                <td>20%</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec4dot2">
        <title>4.2. Stress Field on the Mitral Annulus and Surrounding Tissues</title>
        <p>At each step, the maximum principal stress is evaluated to distinguish between tensile (positive) and compressive (negative) stress states. The thresholds used in the stress maps are post-processing visualization cutoffs only. They were selected to improve figure readability and to isolate the highest-stress regions within each simulation step. They are not tissue damage thresholds, failure criteria, or experimentally validated dehiscence limits. A 140 kPa cutoff was used to highlight broadly stressed regions in the prosthesis-positioning and Physio configurations, whereas a 500 kPa cutoff was used in selected downsizing tensile maps because the stress range was higher. </p>
        <p>4.2.1. Prosthesis Positioning (MEP)</p>
        <p>As shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>, five regions are identified: 1) the prosthetic bed at the atrioventricular junction; 2) the trigones and adjacent ventricular wall; 3) the leaflet free edges; 4) the central anterior leaflet; and 5) the atrial-embedded surface. The maximum principal compressive stress is |402| kPa, and a visualization cutoff of 140 kPa is used to highlight stress sensitive regions. </p>
        <fig id="fig5">
          <label>Figure 5</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId15.jpeg?20260625090641" />
        </fig>
        <p><bold>Figure 5.</bold><bold>Highly compre</bold><bold>ssed regions are identified in dark grey: 1.</bold><bold>the</bold><bold>atrial-embedded surface, 2. the left ventricular myocardium near the left trigone, 3. the trigones areas, 4. the prosthesis-valve contact area, and 5. the atrioventricular junction near the P2 and P3 scallops.</bold></p>
        <p>As shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>, five zones are identified: 1) the commissures; 2) parts of the anterior and posterior leaflets; 3) the atrial cavity surface, excluding the prosthesis contact area; 4) the myocardium; and 5) the aortic wall. The maximum principal tensile stress is 463 kPa, and a visualization cutoff of 140 kPa is used to highlight stress sensitive regions. </p>
        <fig id="fig6">
          <label>Figure 6</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId16.jpeg?20260625090641" />
        </fig>
        <p><bold>Figure 6.</bold><bold>Tensile zones identified with a stress magnitude superior to 140 kPa (dark grey areas): 1. the</bold><bold>commissures, 2. the leaflets near the contact zone, and 3. the atrial-embedded surface. a)</bold><bold>Right</bold><bold>trigone, b) right commissure, c) P3 section of the posterior leaflet, d) P2 section of the posterior leaflet, e) left trigone, and f) left commissure.</bold></p>
        <p>4.2.2. Downsizing </p>
        <p>As shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>, six regions are identified: 1) the ventricular myocardium; 2) the posterior leaflet near the anchors; 3) the inner anterior leaflet and commissural regions; 4) the atrial-embedded surface; 5) the aortic wall; and 6) the inner anchoring surfaces. The maximum principal compressive stress reaches |2.24| MPa at the first anchoring site. Compression within the anchoring surfaces is attributed to the tie constraint between the prosthesis and mitral valve anchors. A steep stress gradient is observed in these areas, indicating that a finer mesh is needed to verify stress magnitude. A visualization cutoff of 140 kPa is used to highlight stress sensitive regions.</p>
        <fig id="fig7">
          <label>Figure 7</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId17.jpeg?20260625090641" />
        </fig>
        <p><bold>Figure 7.</bold><bold>Zones</bold><bold>identified with a stress magnitude superior to |140| kPa in compression (dark grey areas): 1. the commissures, 2. the posterior leaflet (P1 and P2 scallops) near the anchors, 3. inside the anchoring surfaces n</bold><bold>˚</bold><bold>1, 2, 6 and 7, and 4. near the anchors under the leaflets, where the tissue is embedded by the prosthesis.</bold></p>
        <p>As shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>, four zones are identified: 1) around the anchors; 2) on the atrial cavity surface; 3) in the central anterior leaflet; and 4) near the atrial-embedded interface. The maximum principal tensile stress reaches 1.15 MPa. A visualization cutoff of 500 kPa is used to highlight stress sensitive regions. </p>
        <fig id="fig8">
          <label>Figure 8</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId18.jpeg?20260625090641" />
        </fig>
        <p><bold>Figure 8.</bold><bold>Zones ide</bold><bold>ntified with a stress magnitude superior to 500 kPa in traction (dark grey areas): 1. the posterior leaflet (P1 and P2 scallops), 2. near the atrial-embedded surface, and 3. around anchoring sites n</bold><bold>˚</bold><bold>1, 2, 6, 7, 8, 9, 10, 11, 12, 13 and 14.</bold></p>
        <p>For the 14-anchor configuration, post-implantation analysis shows elevated stresses around the mitral annulus, especially near the prosthetic anchors. The highest compressive stresses (|<italic>σ</italic>| &gt; 1.1 MPa) occur near the left trigone at the first anchoring site and in the posterior scallops P1 - P2, spanning roughly the first to eighth anchoring sites. Additional tensile stresses (<italic>σ</italic> &gt; 500 kPa) are found near the posterior anchoring sites and the atrioventricular junction. These peaks indicate regions potentially more prone to tissue fatigue or suture dehiscence. Overall, posterior and commissural regions show higher stress than anterior zones, consistent with the boundary conditions, anatomy, and regional annular tissue differences. </p>
        <p>4.2.3. Physiological Loads: Alternative “Physio” Model</p>
        <p>As shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>, six regions are identified: 1) the leaflets; 2) the ventricular myocardium near the contraction boundary; 3) the atrial cavity surface; 4) the aortic wall; 5) the chordae tendineae insertion sites; and 6) the atrial-embedded interface. The maximum principal compressive stress reaches |1.19| MPa. A visualization cutoff of 140 kPa is used to highlight stress sensitive regions.</p>
        <fig id="fig9">
          <label>Figure 9</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId19.jpeg?20260625090642" />
        </fig>
        <p><bold>Figure 9.</bold><bold>Compressive zone</bold><bold>s identified with a stress magnitude superior to |140| kPa (dark grey areas): 1. the left commissure, 2. the tendinous chords</bold><bold>’</bold><bold>insertion sites, 3. the leaflet</bold><bold>’</bold><bold>s free edges, and 4. the atrial embedding.</bold></p>
        <p>As shown in <xref ref-type="fig" rid="fig10">Figure 10</xref>, five distinct zones are identified under tension: 1) the central region of the anterior leaflet; 2) the chordae tendineae insertion sites; 3) the atrial cavity wall; 4) the atrioventricular junction; and 5) the atrial and ventricular embedded interfaces. The maximum principal tensile stress reaches 1.2 MPa. A visualization cutoff of 140 kPa is used to highlight stress sensitive regions. </p>
        <fig id="fig10">
          <label>Figure 10</label>
          <graphic xlink:href="https://html.scirp.org/file/9103105-rId20.jpeg?20260625090641" />
        </fig>
        <p><bold>Figure 10.</bold><bold>Tensile zones identified with a stress magnitude superior to 140 kPa (</bold><bold>lila</bold><bold>): 1. the tendinous chords</bold><bold>’</bold><bold>insertion sites, and 2. the atrial- and ventricular-embedded surface.</bold></p>
        <p>4.2.4. Parametric Analysis</p>
        <p>If conducted, parametric variations in ring stiffness, ring diameter, and anchor number could clarify the mechanical response of the valve and surrounding tissues. Preliminary results suggest that stiffer rings increase local stress concentrations, whereas more anchoring points may improve load distribution and reduce peak stresses. A comprehensive parametric study is therefore proposed for future work. </p>
      </sec>
    </sec>
    <sec id="sec5">
      <title>5. Discussion</title>
      <sec id="sec5dot1">
        <title>5.1. Comparison with Literature</title>
        <p>5.1.1. Reduction Percentage</p>
        <p>The percentage reductions in the septal-lateral (SL) and commissure-to-commissure (CC) distances after annuloplasty can be compared with values reported in the literature (see <bold>Table 2</bold>).</p>
        <p>Kong <italic>et al.</italic> [[<xref ref-type="bibr" rid="B16">16</xref>]] quantified reductions in both CC and SL distances following simulated annuloplasty. For a final SL distance of 23.5 mm, they reported a 29.88% reduction. Although they did not report CC diameters below 33.94 mm, they observed an approximate 15% reduction at that diameter.</p>
        <p>Wong <italic>et al.</italic> [[<xref ref-type="bibr" rid="B14">14</xref>]] examined dimensional changes after numerical annuloplasty using two ring designs. Starting from an initial SL distance of 14.3 mm, they reported a 7% reduction (to 13.3 mm) with the Physio II ring and a 14% reduction (to 12.3 mm) with the IMR ETlogix ring.</p>
        <p><bold>Table 2.</bold><bold>Septo-</bold><bold>ateral</bold><bold>(SL) distances and reductions referred in Kong</bold><italic><bold>et al.</bold></italic><bold>[</bold>[<xref ref-type="bibr" rid="B16">16</xref>]<bold>], Wong</bold><italic><bold>et al.</bold></italic><bold>[</bold>[<xref ref-type="bibr" rid="B14">14</xref>]<bold>] and Rausch</bold><italic><bold>et al.</bold></italic><bold>[</bold>[<xref ref-type="bibr" rid="B18">18</xref>]<bold>] After An</bold><bold>nuloplasty (AA)</bold><bold>.</bold></p>
        <table-wrap id="tbl2">
          <label>Table 2</label>
          <table>
            <tbody>
              <tr>
                <td>
                  Kong
                  <italic>et al</italic>
                  <italic>.</italic>
                </td>
                <td>AA with classic ring(34 mm)</td>
                <td>AA with classic ring(36 mm)</td>
                <td>AA with GeoForm(36 mm)</td>
              </tr>
              <tr>
                <td>SL distance [mm]</td>
                <td>29.2</td>
                <td>24.9</td>
                <td>4.3</td>
              </tr>
              <tr>
                <td>SL reduction [%]</td>
                <td>28.6</td>
                <td>22.9</td>
                <td>5.7</td>
              </tr>
              <tr>
                <td>
                  Wong
                  <italic>et al</italic>
                  <italic>.</italic>
                </td>
                <td>Baseline distance(long axis)</td>
                <td>AA with Physio II ring(24 mm)</td>
                <td>AA with IMR ETlogix ring (24 mm)</td>
              </tr>
              <tr>
                <td>SL distance [mm]</td>
                <td>14.3</td>
                <td>13.3</td>
                <td>12.3</td>
              </tr>
              <tr>
                <td>SL reduction [%]</td>
                <td>-</td>
                <td>7</td>
                <td>14</td>
              </tr>
              <tr>
                <td>
                  Rausch
                  <italic>et al.</italic>
                </td>
                <td>Baseline distance(long axis)</td>
                <td>Annular dimension change (24 mm)</td>
                <td>Annular dimension change (28 mm)</td>
              </tr>
              <tr>
                <td>SL distance [mm]</td>
                <td>27.47</td>
                <td>23.49</td>
                <td>26.66</td>
              </tr>
              <tr>
                <td>SL reduction [%]</td>
                <td>-</td>
                <td>14</td>
                <td>3</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>Our results are of the same order of magnitude, with a 15% reduction in the septal-lateral (SL) distance and a 20% reduction in the commissure-to-commissure (CC) distance. However, they do not exactly match the values reported in the literature. This discrepancy may be partly explained by uncertainty in the placement of measurement points: in the deformed valve geometry, the boundary between the leaflets and the ventricular wall becomes difficult to delineate. Differences in the initial septal-lateral dimension may also contribute to the observed variation.</p>
        <p>Downsizing strategies also differ across studies. Rausch <italic>et al.</italic> [[<xref ref-type="bibr" rid="B18">18</xref>]] reported a reduction in SL distance accompanied by an increase in CC distance, reflecting a strategy focused on bringing the anterior and posterior leaflets closer together. In contrast, Kong <italic>et al.</italic> [[<xref ref-type="bibr" rid="B16">16</xref>]] reported reductions in both SL and CC directions.</p>
        <p>5.1.2. Stress Distribution</p>
        <p>Kong <italic>et al.</italic> reported average/median maximum principal stresses for the anterior and posterior mitral leaflets after annuloplasty and papillary muscle relocation. These quantities are reported for leaflet regions and should not be directly compared with the localized peak stresses obtained in the present study near idealized anchoring and contact constraints. Therefore, the comparison with Kong <italic>et al.</italic> is used here mainly to discuss stress localization trends rather than absolute stress magnitudes. In both studies, the posterior leaflet/annular region appears mechanically more solicited after annuloplasty than other valve regions</p>
        <p>A key difference between their approach and ours is the use of an anisotropic hyperelastic constitutive law to represent mitral tissue mechanics. In addition, the leaflets are discretized with hexahedral elements, unlike our meshing strategy. Finally, their simulations employ an explicit formulation, which is often considered less suitable than implicit methods for accurately capturing history-dependent stress responses [[<xref ref-type="bibr" rid="B16">16</xref>]].</p>
        <p>In a related numerical study of the mitral valve under physiological loading, Gao <italic>et al.</italic> [[<xref ref-type="bibr" rid="B17">17</xref>]] reported elevated stresses aligned with fiber directions, particularly near the trigones. Their results indicate that the trigonal regions experience higher stress levels than the anterior annulus. Under fully loaded systolic conditions (150 mmHg), the stress at the left trigone reached approximately 193 kPa. </p>
        <p>5.1.3. Synthesis of the Literature Comparison</p>
        <p>In this study, we developed a mechanically consistent mitral valve model that combines a biofaithful geometry, a Neo-Hookean representation of soft-tissue mechanics, and explicit interaction with a prosthetic annuloplasty ring. The model successfully reproduces the downsizing phase of the procedure. While severe mesh distortion currently limits completion of the subsequent ventricular contraction and hemodynamic loading steps in the full annuloplasty setup, these steps have been robustly implemented and validated in an alternative “Physio” configuration without the prosthesis, providing a clear proof of concept. This establishes a solid foundation for reintegrating physiological loading into the complete annuloplasty framework.</p>
        <p>The predicted deformation patterns and stress distributions are coherent with the existing computational literature on annuloplasty. In particular, the concentration of elevated stresses near the fibrous trigones and the posterior annulus is consistent with clinically reported regions prone to suture dehiscence [[<xref ref-type="bibr" rid="B3">3</xref>], [<xref ref-type="bibr" rid="B9">9</xref>]]. Likewise, the simulated septo-lateral (SL) reduction agrees with trends reported in the updated Living Heart Model [[<xref ref-type="bibr" rid="B18">18</xref>]] and other finite element studies of mitral valve mechanics [[<xref ref-type="bibr" rid="B16">16</xref>]]. These results support the relevance of the modeling strategy and confirm its ability to capture key mechanical signatures of the procedure.</p>
        <p>At this stage, the analysis is based on a single mesh configuration, and a mesh-convergence study is therefore essential to consolidate stress magnitudes and gradients, particularly near anchoring regions. Advancing the model will require a finer discretization and dedicated numerical improvements to control the step-to-step mesh distortions that currently drive convergence issues. Addressing these limitations is a clear and achievable next step, and it will unlock the full predictive potential of the annuloplasty simulation under physiological loading.</p>
      </sec>
      <sec id="sec5dot2">
        <title>5.2. Model Limitation</title>
        <p>Several assumptions were necessary given current limitations in available data and computational resources; importantly, each of these choices provides a clear pathway for refinement in future iterations:</p>
        <p>The mitral annulus was not segmented directly from patient-specific imaging, but instead reconstructed from adjacent anatomical landmarks. With improved imaging protocols and segmentation workflows, this step can be made fully patient-specific.</p>
        <p>The mechanical properties of annular tissue were approximated using myocardial properties. While this may overestimate annular compliance and stress sensitivity, it offers a reasonable baseline that can be updated as more annulus-specific experimental data become available.</p>
        <p>Simulations were performed under quasi-static conditions, without explicitly modeling time-varying hemodynamic loads or fatigue behavior. This approach captures the dominant mechanical trends at substantially lower computational cost and establishes a robust foundation for future transient and fatigue-capable analyses.</p>
        <p>Anchor-tissue interactions were represented using idealized tie constraints. This provides a stable first-order representation of fixation and can be progressively enriched to include micro-slippage, frictional contact, or detachment criteria as supporting data and calibration targets are introduced.</p>
        <p>The chordae tendineae were modeled as one-dimensional spring elements distributed along the free edges of the anterior and posterior leaflets. This simplification captures their main stabilizing effect on leaflet mechanics, while leaving open the possibility of incorporating a more detailed chordal architecture in subsequent model updates.</p>
        <p>Additional factors may also contribute to discrepancies, including uncertainty in generic physiological parameters reported in the literature, the absence of pre-strain, and uncertainty introduced during mitral valve geometry reconstruction and smoothing. Further limitations include the assumption of a purely passive response in the annular and valvular regions and the use of a simplified, isotropic, time-independent elastic material law. Each of these elements represents a well-defined opportunity for improvement and will help strengthen the model’s predictive accuracy as the framework evolves.</p>
        <p>The validation strategy will be structured in three steps. First, a mesh-convergence study will be performed to assess the robustness of stress magnitudes and gradients near the anchoring regions. Second, the prosthetic ring model will be compared against available compression-test data to verify its effective stiffness. Third, in vitro dehiscence or pull-out tests on representative annular tissue or tissue-mimicking substrates will be used to compare predicted high-stress regions with experimentally observed failure locations. Only after these validation steps will the framework be suitable for stronger predictive or clinical claims. </p>
      </sec>
      <sec id="sec5dot3">
        <title>5.3. Perspectives and Future Work</title>
        <p>A parametric study will be conducted in future work to evaluate the influence of ring stiffness, ring diameter, anchor number, and anchor orientation on stress localization. This will allow the sensitivity of the model to procedural and device-design parameters to be quantified systematically. </p>
      </sec>
    </sec>
    <sec id="sec6">
      <title>6. Conclusion</title>
      <sec id="sec6dot1">
        <title>6.1. Contribution of This Study</title>
        <p>This study presents a finite element model of the mitral valve and surrounding structures designed to investigate the mechanical response of the atrioventricular-junction region during transcatheter annuloplasty. The current model is based on a single reference anatomy and should be considered a methodological framework rather than a fully validated reference anatomical model digital twin.</p>
        <p>In the complete annuloplasty model, prosthetic ring positioning and annular downsizing were successfully simulated. Physiological ventricular contraction and pressure loading were implemented separately in a “Physio” configuration without the prosthesis, because severe mesh distortion prevented this loading step from being completed in the downsized prosthesis-including model.</p>
        <p>The predicted stress localizations near the fibrous trigones, posterior leaflet region, and atrioventricular-junction region are consistent with trends reported in previous computational studies and with clinically relevant areas for fixation failure. However, the absolute stress magnitudes remain dependent on mesh density, material assumptions, and idealized anchor-tissue constraints. Future work will therefore focus on mesh refinement, validation, and reintegration of physiological loading into the full annuloplasty model. </p>
      </sec>
      <sec id="sec6dot2">
        <title>6.2. Integration into Surgical Planning Tools</title>
        <p>This computational framework lays the groundwork for a patient-specific planning tool that could support cardiac surgeons in selecting an appropriate ring size, optimizing anchor placement, and refining the overall implantation strategy. With further development—such as coupling through fluid–structure interaction, incorporating growth and remodeling mechanisms, and enabling near real-time simulations—this virtual platform could be integrated into clinical workflows, helping to improve procedural outcomes and potentially extend prosthesis durability.</p>
      </sec>
    </sec>
    <sec id="sec7">
      <title>Acknowledgements</title>
      <p>We gratefully acknowledge the support of the Computational Cardiac Modeling group from the Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT) for providing the detailed geometry of the left ventricle used in this study.</p>
      <p>The authors also acknowledge that the original imaging modality and acquisition metadata associated with the provided reference geometry were not available to them.</p>
      <p>This work was conducted within the Hospital-University Research Program ICELAND and was supported by the French National Research Agency (ANR) under grant ANR-21-RHUS-0006.</p>
    </sec>
    <sec id="sec8">
      <title>Declaration</title>
      <p>Prior dissemination: A preliminary version of part of this work was presented as an extended abstract at the European Society of Biomechanics (ESB) in 2025. The present manuscript expands that preliminary work by providing a detailed finite element workflow, additional stress analysis, comparison with the literature, clarification of the separate Physio configuration, and an expanded discussion of limitations and validation needs.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">AlQouba, M., AlHumaidi, M., Al Jarallah, M., Dashti, R., Khalil, M., Al Mulla, K., <italic>et al</italic>. (2024) Mitral Regurgitation Quantification, Management, and Guidelines: A 2024 Update. <italic>Annals</italic><italic>of</italic><italic>Clinical</italic><italic>Cardiology</italic>, 6, 4-16. https://doi.org/10.4103/accj.accj_4_24 <pub-id pub-id-type="doi">10.4103/accj.accj_4_24</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4103/accj.accj_4_24">https://doi.org/10.4103/accj.accj_4_24</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>AlQouba, M.</string-name>
              <string-name>AlHumaidi, M.</string-name>
              <string-name>Jarallah, M.</string-name>
              <string-name>Dashti, R.</string-name>
              <string-name>Khalil, M.</string-name>
              <string-name>Mulla, K.</string-name>
              <string-name>Quantification, M</string-name>
            </person-group>
            <year>2024</year>
            <article-title>Mitral Regurgitation Quantification, Management, and Guidelines: A 2024 Update</article-title>
            <source>Annals of Clinical Cardiology</source>
            <volume>6</volume>
            <pub-id pub-id-type="doi">10.4103/accj.accj_4_24</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B2">
        <label>2.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Carpentier, A. (1983) Cardiac Valve Surgery—The “French Correction”. <italic>The</italic><italic>Journal</italic><italic>of</italic><italic>Thoracic</italic><italic>and</italic><italic>Cardiovascular</italic><italic>Surgery</italic>, 86, 323-337. https://doi.org/10.1016/s0022-5223(19)39144-5 <pub-id pub-id-type="doi">10.1016/s0022-5223(19)39144-5</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/s0022-5223(19)39144-5">https://doi.org/10.1016/s0022-5223(19)39144-5</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Carpentier, A.</string-name>
            </person-group>
            <year>1983</year>
            <article-title>Cardiac Valve Surgery—The “French Correction”</article-title>
            <source>The Journal of Thoracic and Cardiovascular Surgery</source>
            <volume>5223</volume>
            <issue>19</issue>
            <pub-id pub-id-type="doi">10.1016/s0022-5223(19)39144-5</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B3">
        <label>3.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Madukauwa-David, I.D., Pierce, E.L., Sulejmani, F., Pataky, J., Sun, W. and Yoganathan, A.P. (2018) Suture Dehiscence and Collagen Content in the Human Mitral and Tricuspid Annuli. <italic>Biomechanics</italic><italic>and</italic><italic>Modeling</italic><italic>in</italic><italic>Mechanobiology</italic>, 18, 291-299. https://doi.org/10.1007/s10237-018-1082-z <pub-id pub-id-type="doi">10.1007/s10237-018-1082-z</pub-id><pub-id pub-id-type="pmid">30288649</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10237-018-1082-z">https://doi.org/10.1007/s10237-018-1082-z</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Madukauwa-David, I.D.</string-name>
              <string-name>Pierce, E.L.</string-name>
              <string-name>Sulejmani, F.</string-name>
              <string-name>Pataky, J.</string-name>
              <string-name>Sun, W.</string-name>
              <string-name>Yoganathan, A.P.</string-name>
            </person-group>
            <year>2018</year>
            <article-title>Suture Dehiscence and Collagen Content in the Human Mitral and Tricuspid Annuli</article-title>
            <source>Biomechanics and Modeling in Mechanobiology</source>
            <volume>18</volume>
            <pub-id pub-id-type="doi">10.1007/s10237-018-1082-z</pub-id>
            <pub-id pub-id-type="pmid">30288649</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B4">
        <label>4.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Estévez-Loureiro, R., Benito-González, T., Garrote-Coloma, C., Fernández-Vázquez, F., Avanzas, P., Piñón, M., <italic>et al</italic>. (2020) Percutaneous Mitral Repair: Current and Future Devices. <italic>Annals</italic><italic>of</italic><italic>Translational</italic><italic>Medicine</italic>, 8, 963-963. https://doi.org/10.21037/atm.2020.03.154 <pub-id pub-id-type="doi">10.21037/atm.2020.03.154</pub-id><pub-id pub-id-type="pmid">32953763</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.21037/atm.2020.03.154">https://doi.org/10.21037/atm.2020.03.154</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Loureiro, R.</string-name>
              <string-name>Garrote-Coloma, C.</string-name>
              <string-name>Avanzas, P.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Percutaneous Mitral Repair: Current and Future Devices</article-title>
            <source>Annals of Translational Medicine</source>
            <volume>8</volume>
            <pub-id pub-id-type="doi">10.21037/atm.2020.03.154</pub-id>
            <pub-id pub-id-type="pmid">32953763</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B5">
        <label>5.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Maisano, F. and Taramasso, M. (2015) The Cardioband Transcatheter Direct Mitral Valve Annuloplasty System. <italic>EuroIntervention</italic>, 14, W58-W59. https://doi.org/10.4244/eijv11swa15 <pub-id pub-id-type="doi">10.4244/eijv11swa15</pub-id><pub-id pub-id-type="pmid">26384192</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4244/eijv11swa15">https://doi.org/10.4244/eijv11swa15</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Maisano, F.</string-name>
              <string-name>Taramasso, M.</string-name>
            </person-group>
            <year>2015</year>
            <article-title>The Cardioband Transcatheter Direct Mitral Valve Annuloplasty System</article-title>
            <source>EuroIntervention</source>
            <volume>14</volume>
            <pub-id pub-id-type="doi">10.4244/eijv11swa15</pub-id>
            <pub-id pub-id-type="pmid">26384192</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B6">
        <label>6.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Gasparotti, E., Vignali, E., Mariani, M., Berti, S. and Celi, S. (2022) Image-Based Modelling and Numerical Simulations of the Cardioband® Procedure for Mitral Valve Regurgitation Repair. <italic>Computer</italic><italic>Methods</italic><italic>in</italic><italic>Applied</italic><italic>Mechanics</italic><italic>and</italic><italic>Engineering</italic>, 394, Article ID: 114941. https://doi.org/10.1016/j.cma.2022.114941 <pub-id pub-id-type="doi">10.1016/j.cma.2022.114941</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.cma.2022.114941">https://doi.org/10.1016/j.cma.2022.114941</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Gasparotti, E.</string-name>
              <string-name>Vignali, E.</string-name>
              <string-name>Mariani, M.</string-name>
              <string-name>Berti, S.</string-name>
              <string-name>Celi, S.</string-name>
            </person-group>
            <year>2022</year>
            <article-title>Image-Based Modelling and Numerical Simulations of the Cardioband® Procedure for Mitral Valve Regurgitation Repair</article-title>
            <source>Computer Methods in Applied Mechanics and Engineering</source>
            <volume>394</volume>
            <fpage>114941</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.cma.2022.114941</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B7">
        <label>7.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Zeng, G., Li, G., Jia, Y., Chen, S., Chen, P. and He, Z. (2021) Detachment Force of the Helical Anchor in Mitral Annulus. <italic>Medicine</italic><italic>in</italic><italic>Novel</italic><italic>Technology</italic><italic>and</italic><italic>Devices</italic>, 12, Article ID: 100098. https://doi.org/10.1016/j.medntd.2021.100098 <pub-id pub-id-type="doi">10.1016/j.medntd.2021.100098</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.medntd.2021.100098">https://doi.org/10.1016/j.medntd.2021.100098</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Zeng, G.</string-name>
              <string-name>Li, G.</string-name>
              <string-name>Jia, Y.</string-name>
              <string-name>Chen, S.</string-name>
              <string-name>Chen, P.</string-name>
              <string-name>He, Z.</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Detachment Force of the Helical Anchor in Mitral Annulus</article-title>
            <source>Medicine in Novel Technology and Devices</source>
            <volume>12</volume>
            <fpage>100098</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.medntd.2021.100098</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B8">
        <label>8.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Akansel, S., Sündermann, S.H., Kofler, M., Emmerich, A., Falk, V. and Kempfert, J. (2020) Surgical Explantation of a Partially Detached Cardioband Device. <italic>Journal</italic><italic>of</italic><italic>Cardiac</italic><italic>Surgery</italic>, 35, 2100-2102. https://doi.org/10.1111/jocs.14842 <pub-id pub-id-type="doi">10.1111/jocs.14842</pub-id><pub-id pub-id-type="pmid">32668088</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/jocs.14842">https://doi.org/10.1111/jocs.14842</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Akansel, S.</string-name>
              <string-name>Kofler, M.</string-name>
              <string-name>Emmerich, A.</string-name>
              <string-name>Falk, V.</string-name>
              <string-name>Kempfert, J.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Surgical Explantation of a Partially Detached Cardioband Device</article-title>
            <source>Journal of Cardiac Surgery</source>
            <volume>35</volume>
            <pub-id pub-id-type="doi">10.1111/jocs.14842</pub-id>
            <pub-id pub-id-type="pmid">32668088</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B9">
        <label>9.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Pierce, E.L., Siefert, A.W., Paul, D.M., Wells, S.K., Bloodworth, C.H., Takebayashi, S., <italic>et al</italic>. (2016) How Local Annular Force and Collagen Density Govern Mitral Annuloplasty Ring Dehiscence Risk. <italic>The</italic><italic>Annals</italic><italic>of</italic><italic>Thoracic</italic><italic>Surgery</italic>, 102, 518-526. https://doi.org/10.1016/j.athoracsur.2016.01.107 <pub-id pub-id-type="doi">10.1016/j.athoracsur.2016.01.107</pub-id><pub-id pub-id-type="pmid">27133454</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.athoracsur.2016.01.107">https://doi.org/10.1016/j.athoracsur.2016.01.107</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Pierce, E.L.</string-name>
              <string-name>Siefert, A.W.</string-name>
              <string-name>Paul, D.M.</string-name>
              <string-name>Wells, S.K.</string-name>
              <string-name>Bloodworth, C.H.</string-name>
              <string-name>Takebayashi, S.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>How Local Annular Force and Collagen Density Govern Mitral Annuloplasty Ring Dehiscence Risk</article-title>
            <source>The Annals of Thoracic Surgery</source>
            <volume>102</volume>
            <pub-id pub-id-type="doi">10.1016/j.athoracsur.2016.01.107</pub-id>
            <pub-id pub-id-type="pmid">27133454</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B10">
        <label>10.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Faletra, F.F., Leo, L.A., Paiocchi, V.L., Caretta, A., Viani, G.M., Schlossbauer, S.A., <italic>et al</italic>. (2019) Anatomy of Mitral Annulus Insights from Non-Invasive Imaging Techniques. <italic>European</italic><italic>Heart</italic><italic>Journal</italic>— <italic>Cardiovascular</italic><italic>Imaging</italic>, 20, 843-857. https://doi.org/10.1093/ehjci/jez153 <pub-id pub-id-type="doi">10.1093/ehjci/jez153</pub-id><pub-id pub-id-type="pmid">31219549</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/ehjci/jez153">https://doi.org/10.1093/ehjci/jez153</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Faletra, F.F.</string-name>
              <string-name>Leo, L.A.</string-name>
              <string-name>Paiocchi, V.L.</string-name>
              <string-name>Caretta, A.</string-name>
              <string-name>Viani, G.M.</string-name>
              <string-name>Schlossbauer, S.A.</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Anatomy of Mitral Annulus Insights from Non-Invasive Imaging Techniques</article-title>
            <source>European Heart Journal—Cardiovascular Imaging</source>
            <volume>20</volume>
            <pub-id pub-id-type="doi">10.1093/ehjci/jez153</pub-id>
            <pub-id pub-id-type="pmid">31219549</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B11">
        <label>11.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Gunning, G.M. and Murphy, B.P. (2014) Determination of the Tensile Mechanical Properties of the Segmented Mitral Valve Annulus. <italic>Journal</italic><italic>of</italic><italic>Biomechanics</italic>, 47, 334-340. https://doi.org/10.1016/j.jbiomech.2013.11.035 <pub-id pub-id-type="doi">10.1016/j.jbiomech.2013.11.035</pub-id><pub-id pub-id-type="pmid">24326099</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jbiomech.2013.11.035">https://doi.org/10.1016/j.jbiomech.2013.11.035</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Gunning, G.M.</string-name>
              <string-name>Murphy, B.P.</string-name>
            </person-group>
            <year>2014</year>
            <article-title>Determination of the Tensile Mechanical Properties of the Segmented Mitral Valve Annulus</article-title>
            <source>Journal of Biomechanics</source>
            <volume>47</volume>
            <pub-id pub-id-type="doi">10.1016/j.jbiomech.2013.11.035</pub-id>
            <pub-id pub-id-type="pmid">24326099</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B12">
        <label>12.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Saremi, F., Hassani, C. and Sánchez-Quintana, D. (2016) Septal Atrioventricular Junction Region: Comprehensive Imaging in Adults. <italic>RadioGraphics</italic>, 36, 1966-1986. https://doi.org/10.1148/rg.2016160010 <pub-id pub-id-type="doi">10.1148/rg.2016160010</pub-id><pub-id pub-id-type="pmid">27740897</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1148/rg.2016160010">https://doi.org/10.1148/rg.2016160010</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Saremi, F.</string-name>
              <string-name>Hassani, C.</string-name>
              <string-name>Quintana, D.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>Septal Atrioventricular Junction Region: Comprehensive Imaging in Adults</article-title>
            <source>RadioGraphics</source>
            <volume>36</volume>
            <pub-id pub-id-type="doi">10.1148/rg.2016160010</pub-id>
            <pub-id pub-id-type="pmid">27740897</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B13">
        <label>13.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Wright, B.E., Watson, G.L. and Selfridge, N.J. (2020) The Wright Table of the Cardiac Cycle: A Stand-Alone Supplement to the Wiggers Diagram. <italic>Advances</italic><italic>in</italic><italic>Physiology</italic><italic>Education</italic>, 44, 554-563. https://doi.org/10.1152/advan.00141.2019 <pub-id pub-id-type="doi">10.1152/advan.00141.2019</pub-id><pub-id pub-id-type="pmid">32880487</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1152/advan.00141.2019">https://doi.org/10.1152/advan.00141.2019</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Wright, B.E.</string-name>
              <string-name>Watson, G.L.</string-name>
              <string-name>Selfridge, N.J.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>The Wright Table of the Cardiac Cycle: A Stand-Alone Supplement to the Wiggers Diagram</article-title>
            <source>Advances in Physiology Education</source>
            <volume>44</volume>
            <pub-id pub-id-type="doi">10.1152/advan.00141.2019</pub-id>
            <pub-id pub-id-type="pmid">32880487</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B14">
        <label>14.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Wong, V.M., Wenk, J.F., Zhang, Z., Cheng, G., Acevedo-Bolton, G., Burger, M., <italic>et al</italic>. (2012) The Effect of Mitral Annuloplasty Shape in Ischemic Mitral Regurgitation: A Finite Element Simulation. <italic>The</italic><italic>Annals</italic><italic>of</italic><italic>Thoracic</italic><italic>Surgery</italic>, 93, 776-782. https://doi.org/10.1016/j.athoracsur.2011.08.080 <pub-id pub-id-type="doi">10.1016/j.athoracsur.2011.08.080</pub-id><pub-id pub-id-type="pmid">22245588</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.athoracsur.2011.08.080">https://doi.org/10.1016/j.athoracsur.2011.08.080</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Wong, V.M.</string-name>
              <string-name>Wenk, J.F.</string-name>
              <string-name>Zhang, Z.</string-name>
              <string-name>Cheng, G.</string-name>
              <string-name>Acevedo-Bolton, G.</string-name>
              <string-name>Burger, M.</string-name>
            </person-group>
            <year>2012</year>
            <article-title>The Effect of Mitral Annuloplasty Shape in Ischemic Mitral Regurgitation: A Finite Element Simulation</article-title>
            <source>The Annals of Thoracic Surgery</source>
            <volume>93</volume>
            <pub-id pub-id-type="doi">10.1016/j.athoracsur.2011.08.080</pub-id>
            <pub-id pub-id-type="pmid">22245588</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B15">
        <label>15.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Wenk, J.F., Zhang, Z., Cheng, G., Malhotra, D., Acevedo-Bolton, G., Burger, M., <italic>et al</italic>. (2010) First Finite Element Model of the Left Ventricle with Mitral Valve: Insights into Ischemic Mitral Regurgitation. <italic>The</italic><italic>Annals</italic><italic>of</italic><italic>Thoracic</italic><italic>Surgery</italic>, 89, 1546-1553. https://doi.org/10.1016/j.athoracsur.2010.02.036 <pub-id pub-id-type="doi">10.1016/j.athoracsur.2010.02.036</pub-id><pub-id pub-id-type="pmid">20417775</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.athoracsur.2010.02.036">https://doi.org/10.1016/j.athoracsur.2010.02.036</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Wenk, J.F.</string-name>
              <string-name>Zhang, Z.</string-name>
              <string-name>Cheng, G.</string-name>
              <string-name>Malhotra, D.</string-name>
              <string-name>Acevedo-Bolton, G.</string-name>
              <string-name>Burger, M.</string-name>
            </person-group>
            <year>2010</year>
            <article-title>First Finite Element Model of the Left Ventricle with Mitral Valve: Insights into Ischemic Mitral Regurgitation</article-title>
            <source>The Annals of Thoracic Surgery</source>
            <volume>89</volume>
            <pub-id pub-id-type="doi">10.1016/j.athoracsur.2010.02.036</pub-id>
            <pub-id pub-id-type="pmid">20417775</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B16">
        <label>16.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Kong, F., Pham, T., Martin, C., Elefteriades, J., McKay, R., Primiano, C., <italic>et al</italic>. (2018) Finite Element Analysis of Annuloplasty and Papillary Muscle Relocation on a Patient-Specific Mitral Regurgitation Model. <italic>PLOS</italic><italic>ONE</italic>, 13, e0198331. https://doi.org/10.1371/journal.pone.0198331 <pub-id pub-id-type="doi">10.1371/journal.pone.0198331</pub-id><pub-id pub-id-type="pmid">29902273</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1371/journal.pone.0198331">https://doi.org/10.1371/journal.pone.0198331</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Kong, F.</string-name>
              <string-name>Pham, T.</string-name>
              <string-name>Martin, C.</string-name>
              <string-name>Elefteriades, J.</string-name>
              <string-name>McKay, R.</string-name>
              <string-name>Primiano, C.</string-name>
            </person-group>
            <year>2018</year>
            <article-title>Finite Element Analysis of Annuloplasty and Papillary Muscle Relocation on a Patient-Specific Mitral Regurgitation Model</article-title>
            <source>PLOS ONE</source>
            <volume>13</volume>
            <pub-id pub-id-type="doi">10.1371/journal.pone.0198331</pub-id>
            <pub-id pub-id-type="pmid">29902273</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B17">
        <label>17.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Gao, H., Feng, L., Qi, N., Berry, C., Griffith, B.E. and Luo, X. (2017) A Coupled Mitral Valve—Left Ventricle Model with Fluid-Structure Interaction. <italic>Medical</italic><italic>Engineering</italic><italic>&amp;</italic><italic>Physics</italic>, 47, 128-136. https://doi.org/10.1016/j.medengphy.2017.06.042 <pub-id pub-id-type="doi">10.1016/j.medengphy.2017.06.042</pub-id><pub-id pub-id-type="pmid">28751011</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.medengphy.2017.06.042">https://doi.org/10.1016/j.medengphy.2017.06.042</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Gao, H.</string-name>
              <string-name>Feng, L.</string-name>
              <string-name>Qi, N.</string-name>
              <string-name>Berry, C.</string-name>
              <string-name>Griffith, B.E.</string-name>
              <string-name>Luo, X.</string-name>
            </person-group>
            <year>2017</year>
            <article-title>A Coupled Mitral Valve—Left Ventricle Model with Fluid-Structure Interaction</article-title>
            <source>Medical Engineering &amp; Physics</source>
            <volume>47</volume>
            <pub-id pub-id-type="doi">10.1016/j.medengphy.2017.06.042</pub-id>
            <pub-id pub-id-type="pmid">28751011</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B18">
        <label>18.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Rausch, M.K., Zöllner, A.M., Genet, M., Baillargeon, B., Bothe, W. and Kuhl, E. (2016) A Virtual Sizing Tool for Mitral Valve Annuloplasty. <italic>International</italic><italic>Journal</italic><italic>for</italic><italic>Numerical</italic><italic>Methods</italic><italic>in</italic><italic>Biomedical</italic><italic>Engineering</italic>, 33, e02788. https://doi.org/10.1002/cnm.2788 <pub-id pub-id-type="doi">10.1002/cnm.2788</pub-id><pub-id pub-id-type="pmid">27028496</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/cnm.2788">https://doi.org/10.1002/cnm.2788</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Rausch, M.K.</string-name>
              <string-name>Genet, M.</string-name>
              <string-name>Baillargeon, B.</string-name>
              <string-name>Bothe, W.</string-name>
              <string-name>Kuhl, E.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>A Virtual Sizing Tool for Mitral Valve Annuloplasty</article-title>
            <source>International Journal for Numerical Methods in Biomedical Engineering</source>
            <volume>33</volume>
            <pub-id pub-id-type="doi">10.1002/cnm.2788</pub-id>
            <pub-id pub-id-type="pmid">27028496</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B19">
        <label>19.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Baillargeon, B., Costa, I., Leach, J.R., Lee, L.C., Genet, M., Toutain, A., <italic>et al</italic>. (2015) Human Cardiac Function Simulator for the Optimal Design of a Novel Annuloplasty Ring with a Sub-Valvular Element for Correction of Ischemic Mitral Regurgitation. <italic>Cardiovascular</italic><italic>Engineering</italic><italic>and</italic><italic>Technology</italic>, 6, 105-116. https://doi.org/10.1007/s13239-015-0216-z <pub-id pub-id-type="doi">10.1007/s13239-015-0216-z</pub-id><pub-id pub-id-type="pmid">25984248</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s13239-015-0216-z">https://doi.org/10.1007/s13239-015-0216-z</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Baillargeon, B.</string-name>
              <string-name>Costa, I.</string-name>
              <string-name>Leach, J.R.</string-name>
              <string-name>Lee, L.C.</string-name>
              <string-name>Genet, M.</string-name>
              <string-name>Toutain, A.</string-name>
            </person-group>
            <year>2015</year>
            <article-title>Human Cardiac Function Simulator for the Optimal Design of a Novel Annuloplasty Ring with a Sub-Valvular Element for Correction of Ischemic Mitral Regurgitation</article-title>
            <source>Cardiovascular Engineering and Technology</source>
            <volume>6</volume>
            <pub-id pub-id-type="doi">10.1007/s13239-015-0216-z</pub-id>
            <pub-id pub-id-type="pmid">25984248</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B20">
        <label>20.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Holzapfel, G.A. and Ogden, R.W. (2009) Constitutive Modelling of Passive Myocardium: A Structurally Based Framework for Material Characterization. <italic>Philosophical</italic><italic>Transactions</italic><italic>of</italic><italic>the</italic><italic>Royal</italic><italic>Society</italic><italic>A</italic>: <italic>Mathematical</italic>, <italic>Physical</italic><italic>and</italic><italic>Engineering</italic><italic>Sciences</italic>, 367, 3445-3475. https://doi.org/10.1098/rsta.2009.0091 <pub-id pub-id-type="doi">10.1098/rsta.2009.0091</pub-id><pub-id pub-id-type="pmid">19657007</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1098/rsta.2009.0091">https://doi.org/10.1098/rsta.2009.0091</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Holzapfel, G.A.</string-name>
              <string-name>Ogden, R.W.</string-name>
              <string-name>Mathematical, P</string-name>
            </person-group>
            <year>2009</year>
            <article-title>Constitutive Modelling of Passive Myocardium: A Structurally Based Framework for Material Characterization</article-title>
            <source>Philosophical Transactions of the Royal Society A: Mathematical</source>
            <volume>367</volume>
            <pub-id pub-id-type="doi">10.1098/rsta.2009.0091</pub-id>
            <pub-id pub-id-type="pmid">19657007</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B21">
        <label>21.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Hossien, A., Nithiarasu, P., Cheriex, E., Maessen, J., Sardari Nia, P. and Ashraf, S. (2015) A Multidimensional Dynamic Quantification Tool for the Mitral Valve. <italic>Interactive</italic><italic>CardioVascular</italic><italic>and</italic><italic>Thoracic</italic><italic>Surgery</italic>, 21, 481-487. https://doi.org/10.1093/icvts/ivv187 <pub-id pub-id-type="doi">10.1093/icvts/ivv187</pub-id><pub-id pub-id-type="pmid">26174119</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/icvts/ivv187">https://doi.org/10.1093/icvts/ivv187</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Hossien, A.</string-name>
              <string-name>Nithiarasu, P.</string-name>
              <string-name>Cheriex, E.</string-name>
              <string-name>Maessen, J.</string-name>
              <string-name>Nia, P.</string-name>
              <string-name>Ashraf, S.</string-name>
            </person-group>
            <year>2015</year>
            <article-title>A Multidimensional Dynamic Quantification Tool for the Mitral Valve</article-title>
            <source>Interactive CardioVascular and Thoracic Surgery</source>
            <volume>21</volume>
            <pub-id pub-id-type="doi">10.1093/icvts/ivv187</pub-id>
            <pub-id pub-id-type="pmid">26174119</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B22">
        <label>22.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Jeganathan, J., Owais, K., Montealegre-Gallegos, M., Matyal, R., Khabbaz, K. and Mahmood, F. (2016) Dynamic Changes in the Ischemic Mitral Annulus: Implications for Ring Sizing. <italic>Annals</italic><italic>of</italic><italic>Cardiac</italic><italic>Anaesthesia</italic>, 19, 15-19. https://doi.org/10.4103/0971-9784.173014 <pub-id pub-id-type="doi">10.4103/0971-9784.173014</pub-id><pub-id pub-id-type="pmid">26750668</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4103/0971-9784.173014">https://doi.org/10.4103/0971-9784.173014</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Jeganathan, J.</string-name>
              <string-name>Owais, K.</string-name>
              <string-name>Montealegre-Gallegos, M.</string-name>
              <string-name>Matyal, R.</string-name>
              <string-name>Khabbaz, K.</string-name>
              <string-name>Mahmood, F.</string-name>
            </person-group>
            <year>2016</year>
            <article-title>Dynamic Changes in the Ischemic Mitral Annulus: Implications for Ring Sizing</article-title>
            <source>Annals of Cardiac Anaesthesia</source>
            <volume>19</volume>
            <pub-id pub-id-type="doi">10.4103/0971-9784.173014</pub-id>
            <pub-id pub-id-type="pmid">26750668</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B23">
        <label>23.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Chen, S., Sari, C.R., Gao, H., Lei, Y., Segers, P., De Beule, M., <italic>et al</italic>. (2020) Mechanical and Morphometric Study of Mitral Valve Chordae Tendineae and Related Papillary Muscle. <italic>Journal</italic><italic>of</italic><italic>the</italic><italic>Mechanical</italic><italic>Behavior</italic><italic>of</italic><italic>Biomedical</italic><italic>Materials</italic>, 111, Article ID: 104011. https://doi.org/10.1016/j.jmbbm.2020.104011 <pub-id pub-id-type="doi">10.1016/j.jmbbm.2020.104011</pub-id><pub-id pub-id-type="pmid">32835989</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jmbbm.2020.104011">https://doi.org/10.1016/j.jmbbm.2020.104011</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Chen, S.</string-name>
              <string-name>Sari, C.R.</string-name>
              <string-name>Gao, H.</string-name>
              <string-name>Lei, Y.</string-name>
              <string-name>Segers, P.</string-name>
              <string-name>Beule, M.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Mechanical and Morphometric Study of Mitral Valve Chordae Tendineae and Related Papillary Muscle</article-title>
            <source>Journal of the Mechanical Behavior of Biomedical Materials</source>
            <volume>111</volume>
            <fpage>104011</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1016/j.jmbbm.2020.104011</pub-id>
            <pub-id pub-id-type="pmid">32835989</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B24">
        <label>24.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Millard, L., Espino, D.M., Shepherd, D.E.T., Hukins, D.W.L. and Buchan, K.G. (2011) Mechanical Properties of Chordae Tendineae of the Mitral Heart Valve: Young’s Modulus, Structural Stiffness, and Effects of Aging. <italic>Journal</italic><italic>of</italic><italic>Mechanics</italic><italic>in</italic><italic>Medicine</italic><italic>and</italic><italic>Biology</italic>, 11, 221-230. https://doi.org/10.1142/s0219519411003971 <pub-id pub-id-type="doi">10.1142/s0219519411003971</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1142/s0219519411003971">https://doi.org/10.1142/s0219519411003971</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Millard, L.</string-name>
              <string-name>Espino, D.M.</string-name>
              <string-name>Shepherd, D.E.T.</string-name>
              <string-name>Hukins, D.W.L.</string-name>
              <string-name>Buchan, K.G.</string-name>
              <string-name>Modulus, S</string-name>
            </person-group>
            <year>2011</year>
            <article-title>Mechanical Properties of Chordae Tendineae of the Mitral Heart Valve: Young’s Modulus, Structural Stiffness, and Effects of Aging</article-title>
            <source>Journal of Mechanics in Medicine and Biology</source>
            <volume>11</volume>
            <pub-id pub-id-type="doi">10.1142/s0219519411003971</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B25">
        <label>25.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Daub, A., Kriegseis, J. and Frohnapfel, B. (2020) Replication of Left Ventricular Haemodynamics with a Simple Planar Mitral Valve Model. <italic>Biomedical</italic><italic>Engineering</italic>/ <italic>Biomedizinische</italic><italic>Technik</italic>, 65, 595-603. https://doi.org/10.1515/bmt-2019-0175 <pub-id pub-id-type="doi">10.1515/bmt-2019-0175</pub-id><pub-id pub-id-type="pmid">32598293</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1515/bmt-2019-0175">https://doi.org/10.1515/bmt-2019-0175</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Daub, A.</string-name>
              <string-name>Kriegseis, J.</string-name>
              <string-name>Frohnapfel, B.</string-name>
            </person-group>
            <year>2020</year>
            <article-title>Replication of Left Ventricular Haemodynamics with a Simple Planar Mitral Valve Model</article-title>
            <source>Biomedical Engineering/Biomedizinische Technik</source>
            <volume>65</volume>
            <pub-id pub-id-type="doi">10.1515/bmt-2019-0175</pub-id>
            <pub-id pub-id-type="pmid">32598293</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B26">
        <label>26.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Kevin, L.G. and Barnard, M. (2007) Right Ventricular Failure. <italic>Continuing</italic><italic>Education</italic><italic>in</italic><italic>Anaesthesia</italic><italic>Critical</italic><italic>Care</italic><italic>&amp;</italic><italic>Pain</italic>, 7, 89-94. https://doi.org/10.1093/bjaceaccp/mkm016 <pub-id pub-id-type="doi">10.1093/bjaceaccp/mkm016</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1093/bjaceaccp/mkm016">https://doi.org/10.1093/bjaceaccp/mkm016</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Kevin, L.G.</string-name>
              <string-name>Barnard, M.</string-name>
            </person-group>
            <year>2007</year>
            <article-title>Right Ventricular Failure</article-title>
            <source>Continuing Education in Anaesthesia Critical Care &amp; Pain</source>
            <volume>7</volume>
            <pub-id pub-id-type="doi">10.1093/bjaceaccp/mkm016</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B27">
        <label>27.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Feneley, M.P., Gavaghan, T.P., Baron, D.W., Branson, J.A., Roy, P.R. and Morgan, J.J. (1985) Contribution of Left Ventricular Contraction to the Generation of Right Ventricular Systolic Pressure in the Human Heart. <italic>Circulation</italic>, 71, 473-480. https://doi.org/10.1161/01.cir.71.3.473 <pub-id pub-id-type="doi">10.1161/01.cir.71.3.473</pub-id><pub-id pub-id-type="pmid">2578902</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1161/01.cir.71.3.473">https://doi.org/10.1161/01.cir.71.3.473</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Feneley, M.P.</string-name>
              <string-name>Gavaghan, T.P.</string-name>
              <string-name>Baron, D.W.</string-name>
              <string-name>Branson, J.A.</string-name>
              <string-name>Roy, P.R.</string-name>
              <string-name>Morgan, J.J.</string-name>
            </person-group>
            <year>1985</year>
            <article-title>Contribution of Left Ventricular Contraction to the Generation of Right Ventricular Systolic Pressure in the Human Heart</article-title>
            <source>Circulation</source>
            <volume>71</volume>
            <pub-id pub-id-type="doi">10.1161/01.cir.71.3.473</pub-id>
            <pub-id pub-id-type="pmid">2578902</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B28">
        <label>28.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Gheorghe, A.G., Fuchs, A., Jacobsen, C., Kofoed, K.F., Møgelvang, R., Lynnerup, N., <italic>et al</italic>. (2019) Cardiac Left Ventricular Myocardial Tissue Density, Evaluated by Computed Tomography and Autopsy. <italic>BMC</italic><italic>Medical</italic><italic>Imaging</italic>, 19, Article No. 29. https://doi.org/10.1186/s12880-019-0326-4 <pub-id pub-id-type="doi">10.1186/s12880-019-0326-4</pub-id><pub-id pub-id-type="pmid">30979363</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s12880-019-0326-4">https://doi.org/10.1186/s12880-019-0326-4</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Gheorghe, A.G.</string-name>
              <string-name>Fuchs, A.</string-name>
              <string-name>Jacobsen, C.</string-name>
              <string-name>Kofoed, K.F.</string-name>
              <string-name>Lynnerup, N.</string-name>
              <string-name>Density, E</string-name>
            </person-group>
            <year>2019</year>
            <article-title>Cardiac Left Ventricular Myocardial Tissue Density, Evaluated by Computed Tomography and Autopsy</article-title>
            <source>BMC Medical Imaging</source>
            <volume>19</volume>
            <elocation-id>No</elocation-id>
            <pub-id pub-id-type="doi">10.1186/s12880-019-0326-4</pub-id>
            <pub-id pub-id-type="pmid">30979363</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B29">
        <label>29.</label>
        <citation-alternatives>
          <mixed-citation publication-type="journal">Huyer, L.D., Montgomery, M., Zhao, Y., Xiao, Y., Conant, G., Korolj, A., <italic>et al</italic>. (2015) Biomaterial Based Cardiac Tissue Engineering and Its Applications. <italic>Biomedical</italic><italic>Materials</italic>, 10, Article ID: 034004. https://doi.org/10.1088/1748-6041/10/3/034004 <pub-id pub-id-type="doi">10.1088/1748-6041/10/3/034004</pub-id><pub-id pub-id-type="pmid">25989939</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1088/1748-6041/10/3/034004">https://doi.org/10.1088/1748-6041/10/3/034004</ext-link></mixed-citation>
          <element-citation publication-type="journal">
            <person-group person-group-type="author">
              <string-name>Huyer, L.D.</string-name>
              <string-name>Montgomery, M.</string-name>
              <string-name>Zhao, Y.</string-name>
              <string-name>Xiao, Y.</string-name>
              <string-name>Conant, G.</string-name>
              <string-name>Korolj, A.</string-name>
            </person-group>
            <year>2015</year>
            <article-title>Biomaterial Based Cardiac Tissue Engineering and Its Applications</article-title>
            <source>Biomedical Materials</source>
            <volume>10</volume>
            <fpage>034004</fpage>
            <elocation-id>ID</elocation-id>
            <pub-id pub-id-type="doi">10.1088/1748-6041/10/3/034004</pub-id>
            <pub-id pub-id-type="pmid">25989939</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B30">
        <label>30.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Emig, R., Zgierski-Johnston, C.M., Timmermann, V., Taberner, A.J., Nash, M.P., Kohl, P., <italic>et al</italic>. (2021) Passive Myocardial Mechanical Properties: Meaning, Measurement, Models. <italic>Biophysical</italic><italic>Reviews</italic>, 13, 587-610. https://doi.org/10.1007/s12551-021-00838-1 <pub-id pub-id-type="doi">10.1007/s12551-021-00838-1</pub-id><pub-id pub-id-type="pmid">34765043</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12551-021-00838-1">https://doi.org/10.1007/s12551-021-00838-1</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Emig, R.</string-name>
              <string-name>Zgierski-Johnston, C.M.</string-name>
              <string-name>Timmermann, V.</string-name>
              <string-name>Taberner, A.J.</string-name>
              <string-name>Nash, M.P.</string-name>
              <string-name>Kohl, P.</string-name>
              <string-name>Meaning, M</string-name>
            </person-group>
            <year>2021</year>
            <article-title>Passive Myocardial Mechanical Properties: Meaning, Measurement, Models</article-title>
            <source>Biophysical Reviews</source>
            <volume>13</volume>
            <pub-id pub-id-type="doi">10.1007/s12551-021-00838-1</pub-id>
            <pub-id pub-id-type="pmid">34765043</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
      <ref id="B31">
        <label>31.</label>
        <citation-alternatives>
          <mixed-citation publication-type="other">Purser, M.F., Richards, A.L., Cook, R.C., Osborne, J.A., Cormier, D.R. and Buckner, G.D. (2010) A Novel Shape Memory Alloy Annuloplasty Ring for Minimally Invasive Surgery: Design, Fabrication, and Evaluation. <italic>Annals</italic><italic>of</italic><italic>Biomedical</italic><italic>Engineering</italic>, 39, 367-377. https://doi.org/10.1007/s10439-010-0126-z <pub-id pub-id-type="doi">10.1007/s10439-010-0126-z</pub-id><pub-id pub-id-type="pmid">20652747</pub-id><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10439-010-0126-z">https://doi.org/10.1007/s10439-010-0126-z</ext-link></mixed-citation>
          <element-citation publication-type="other">
            <person-group person-group-type="author">
              <string-name>Purser, M.F.</string-name>
              <string-name>Richards, A.L.</string-name>
              <string-name>Cook, R.C.</string-name>
              <string-name>Osborne, J.A.</string-name>
              <string-name>Cormier, D.R.</string-name>
              <string-name>Buckner, G.D.</string-name>
              <string-name>Design, F</string-name>
            </person-group>
            <year>2010</year>
            <article-title>A Novel Shape Memory Alloy Annuloplasty Ring for Minimally Invasive Surgery: Design, Fabrication, and Evaluation</article-title>
            <source>Annals of Biomedical Engineering</source>
            <volume>39</volume>
            <pub-id pub-id-type="doi">10.1007/s10439-010-0126-z</pub-id>
            <pub-id pub-id-type="pmid">20652747</pub-id>
          </element-citation>
        </citation-alternatives>
      </ref>
    </ref-list>
  </back>
</article>