<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">
    ojapps
   </journal-id>
   <journal-title-group>
    <journal-title>
     Open Journal of Applied Sciences
    </journal-title>
   </journal-title-group>
   <issn pub-type="epub">
    2165-3917
   </issn>
   <issn publication-format="print">
    2165-3925
   </issn>
   <publisher>
    <publisher-name>
     Scientific Research Publishing
    </publisher-name>
   </publisher>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="doi">
    10.4236/ojapps.2025.1510211
   </article-id>
   <article-id pub-id-type="publisher-id">
    ojapps-146680
   </article-id>
   <article-categories>
    <subj-group subj-group-type="heading">
     <subject>
      Articles
     </subject>
    </subj-group>
    <subj-group subj-group-type="Discipline-v2">
     <subject>
      Biomedical 
     </subject>
     <subject>
       Life Sciences, Chemistry 
     </subject>
     <subject>
       Materials Science, Computer Science 
     </subject>
     <subject>
       Communications, Engineering, Physics 
     </subject>
     <subject>
       Mathematics
     </subject>
    </subj-group>
   </article-categories>
   <title-group>
    Mapping Saline Intrusion by Using Electrical Conductivity of the Continental Terminal Water (Northern Limit of the Ebrié Lagoon)
   </title-group>
   <contrib-group>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Adama
      </surname>
      <given-names>
       Coulibaly
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff1"> 
      <sup>1</sup>
     </xref>
    </contrib>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Rock Armand Michel
      </surname>
      <given-names>
       Bouadou
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff2"> 
      <sup>2</sup>
     </xref>
    </contrib>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Kouamé Auguste
      </surname>
      <given-names>
       Kouassi
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff2"> 
      <sup>2</sup>
     </xref>
    </contrib>
   </contrib-group> 
   <aff id="aff1">
    <addr-line>
     aLaboratory of Soil, Water and Geomaterials Sciences, UFR of Earth Sciences and Mineral Resources, University of Félix Houphouët-Boigny, Abidjan, Côte d’Ivoire
    </addr-line> 
   </aff> 
   <aff id="aff2">
    <addr-line>
     aLaboratory of Geosciences and Environment, Environmental Science and Management Training and Research Unit, University Nangui Abrogoua, Abidjan, Côte d’Ivoire
    </addr-line> 
   </aff> 
   <pub-date pub-type="epub">
    <day>
     30
    </day> 
    <month>
     09
    </month>
    <year>
     2025
    </year>
   </pub-date> 
   <volume>
    15
   </volume> 
   <issue>
    10
   </issue>
   <fpage>
    3274
   </fpage>
   <lpage>
    3290
   </lpage>
   <history>
    <date date-type="received">
     <day>
      28,
     </day>
     <month>
      September
     </month>
     <year>
      2025
     </year>
    </date>
    <date date-type="published">
     <day>
      25,
     </day>
     <month>
      September
     </month>
     <year>
      2025
     </year> 
    </date> 
    <date date-type="accepted">
     <day>
      25,
     </day>
     <month>
      October
     </month>
     <year>
      2025
     </year> 
    </date>
   </history>
   <permissions>
    <copyright-statement>
     © Copyright 2014 by authors and Scientific Research Publishing Inc. 
    </copyright-statement>
    <copyright-year>
     2014
    </copyright-year>
    <license>
     <license-p>
      This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/
     </license-p>
    </license>
   </permissions>
   <abstract>
    Continental Terminal waters of the Ivorian sedimentary basin are being exploited to supply the population with drinking water. In 2013, the catchment fields extracted around 400.000 m
    <sup>3</sup>/d from the water table, although this production was insufficient to cover the needs. However, one of the consequences of this overexploitation of water is saline intrusion into the aquifer. In order to assess the level of contamination of the “Abidjan water table”, a water mineralization study in piezometers located on the northern edge of the Ebrié lagoon was carried out. This study took place in March 2022, during the major dry season and involved twenty boreholes. A piezometric probe was used for this purpose. The study focused on the horizontal spatialization of surface and on the vertical distribution of electrical conductivities. Analysis of the spatial distribution of water indicates that the CT water is generally “fresh water”, except those of the piezometer PZ_C2D 9. There, brackish and salty water is recorded. However, brackish water is abundant deeper in the basement at seven piezometers. These piezometers are located respectively along the Ebrié lagoon and around the Aghien lagoon. This study reveals that the Continental Terminal waters on the northern limit of the Ebrié lagoon are not yet affected by marine intrusion.
   </abstract>
   <kwd-group> 
    <kwd>
     Sedimentary Basin
    </kwd> 
    <kwd>
      Continental Terminal
    </kwd> 
    <kwd>
      Electrical Conductivity
    </kwd> 
    <kwd>
      Spatial Distribution
    </kwd> 
    <kwd>
      Saltwater Intrusion
    </kwd> 
    <kwd>
      Fresh Water
    </kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <sec id="s1">
   <title>1. Introduction</title>
   <p>Water is essential to life, to natural ecosystems and is an indisputable socio-economic asset. This water is stored in aquifers (continuous and discontinuous), which are more or less exposed to pollution. One source of pollution is marine intrusion in coastal areas. In this area, salinization makes it difficult to use groundwater for domestic purposes. Heavy mineralization of coastal groundwater is generally linked to the intrusion of marine water <xref ref-type="bibr" rid="scirp.146680-1">
     [1]
    </xref> <xref ref-type="bibr" rid="scirp.146680-2">
     [2]
    </xref>. This intrusion is marked by high concentrations of certain minerals. In addition, mineral salts are added by sea spray dissolution, cation exchange and anthropogenic pollution <xref ref-type="bibr" rid="scirp.146680-3">
     [3]
    </xref>. The mineralization of groundwater is often assessed by measuring electrical conductivity <xref ref-type="bibr" rid="scirp.146680-4">
     [4]
    </xref>. This is because most of the dissolved matter in water is in the form of electrically charged ions.</p>
   <p>In the District of Abidjan (Côte d’Ivoire), drinking water is supplied to the population from catchment areas comprising around a hundred boreholes. According to the Ministry of Water, Sanitation, and Hygiene, approximately 06 m<sup>3</sup>/s of water is extracted from the Continental Terminal aquifer for this purpose. Although it is already very high, this flow is constantly increasing, due to the high demand for water. Overexploitation of this resource is a threat to the waters of the Continental Terminal <xref ref-type="bibr" rid="scirp.146680-5">
     [5]
    </xref> <xref ref-type="bibr" rid="scirp.146680-6">
     [6]
    </xref>. Also, over the last few decades, industrial exploitation of sand in the lagoon has developed to meet the needs of the megalopolis of Abidjan. However, these sands are extracted from geological layers that protect the Abidjan water table beneath the lagoon. Finally, previous studies <xref ref-type="bibr" rid="scirp.146680-7">
     [7]
    </xref> carried out on this water table have highlighted salinity problems in the water from certain boreholes in Plateau and Adjamé. High levels of dissolved salts (chlorides) and high mineralization (electrical conductivity of between 7000 and 10,500 µS∙cm<sup>−</sup><sup>1</sup>) <xref ref-type="bibr" rid="scirp.146680-8">
     [8]
    </xref> have been recorded in the water from these boreholes, indicating marine intrusion.</p>
   <p>Faced with this challenge, the aim of this study is to analyse changes in the electrical conductivity of the Continental Terminal water at the northern edge of the Ebrié Lagoon, with a view to identifying the wedge.</p>
  </sec><sec id="s2">
   <title>2. Presentation of the Study Area</title>
   <sec id="s2_1">
    <title>2.1. Geographical Location</title>
    <p>Located in the south of Côte d’Ivoire, the study area lies on the northern edge of the Ebrié Lagoon, between 4˚15'57.6'' and 3˚45'36'' West and 5˚17'20.4'' and 5˚27'57.6'' North (<xref ref-type="fig" rid="fig1">
      Figure 1
     </xref>). It belongs to the Autonomous District of Abidjan, which comprises ten (10) municipalities and four (04) sub-prefectures covering an area of around 1.160 km<sup>2</sup> and with an estimated population of 29 million <xref ref-type="bibr" rid="scirp.146680-9">
      [9]
     </xref>.</p>
    <p>It has three main lagoons. The Ebrié lagoon, the largest, is a vast expanse of navigable water covering 566 km<sup>2</sup> and connected to the Atlantic Ocean via the Vridi canal. It receives water from the Comoé river, the Agnéby and Mé rivers <xref ref-type="bibr" rid="scirp.146680-10">
      [10]
     </xref>. The Potou and Aghien lagoons are small internal lagoons running north-south. They flow into the Ebrié Lagoon <xref ref-type="bibr" rid="scirp.146680-11">
      [11]
     </xref> (<xref ref-type="fig" rid="fig2">
      Figure 2
     </xref>).</p>
    <fig id="fig1" position="float">
     <label>Figure 1</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Figure 1. Location of the study area.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId15.jpeg?20251028090948" />
    </fig>
    <fig id="fig2" position="float">
     <label>Figure 2</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Figure 2. Hydrographic network in the study area.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId16.jpeg?20251028090948" />
    </fig>
    <p>The most important rivers are <xref ref-type="bibr" rid="scirp.146680-12">
      [12]
     </xref>:</p>
   </sec>
   <sec id="s2_2">
    <title>2.2. Geological Context</title>
    <p>The geological context of the study area generally belongs to the sedimentary basin. The sedimentary formations in this basin are grouped into two main formations: the Continental Terminal in the northern part of the lagoon fault and the Quaternary to the south of this fault <xref ref-type="bibr" rid="scirp.146680-14">
      [14]
     </xref>. The Continental Terminal or Tertiary is made up of sandy-clay sediments, gravels and conglomerates, while the Quaternary is composed of marsh muds and sand (<xref ref-type="fig" rid="fig3">
      Figure 3
     </xref>).</p>
    <fig id="fig3" position="float">
     <label>Figure 3</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Figure 3. Geological map of the study area.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId17.jpeg?20251028090949" />
    </fig>
   </sec>
   <sec id="s2_3">
    <title>2.3. Hydrogeological Context</title>
    <p>The hydrogeological overview of the Ivorian coastal sedimentary basin at the northern boundary of the Ebrié Lagoon reveals the existence of a Continental Terminal aquifer. It comprises four horizons superimposed from top to bottom <xref ref-type="bibr" rid="scirp.146680-15">
      [15]
     </xref>:</p>
    <p>According to the same authors, horizons 3 and 4 make up the bulk of the Continental Terminal aquifer. Generally unconfined, lenticular clay banks located at the top of horizon 3 make the aquifer captive in some areas. These horizons form a single aquifer when these clay banks are absent. Horizon 2 is a sterile aquifer and horizon 1 contains the water table at the base of the Tertiary period.</p>
    <p>Exploitation of the Continental Terminal aquifer, commonly known as the “Abidjan aquifer” accounts for 68% of Côte d’Ivoire’s drinking water supply. This water table also feeds the Maestrichtian one at its base <xref ref-type="bibr" rid="scirp.146680-16">
      [16]
     </xref> because of the thickness of the clay and ferruginous sandstone separating the two aquifers.</p>
   </sec>
   <sec id="s2_4">
    <title>2.4. Influence of Environmental Factors on Water Mineralization</title>
    <p>The various processes involved in the mineralization of groundwater were determined by studying the spatial and temporal evolution of electrical conductivity, piezometry and correlations between the major elements. Water mineralization is often assessed by measuring electrical conductivity <xref ref-type="bibr" rid="scirp.146680-4">
      [4]
     </xref>. This is because most of the dissolved matter in water is in the form of electrically charged ions <xref ref-type="bibr" rid="scirp.146680-8">
      [8]
     </xref>.</p>
    <p>In this study, electrical conductivity was used as a marker of the mineralization of the Continental Terminal groundwater.</p>
   </sec>
  </sec><sec id="s3">
   <title>3. Material and Methods</title>
   <sec id="s3_1">
    <title>3.1. Data Acquisition</title>
    <p>Electrical conductivity measurement campaign was carried out using a sound piezometric probe at twenty (20) piezometers (<xref ref-type="fig" rid="fig4">
      Figure 4
     </xref>) covering the study area. It took place from 02 to 05 March 2022, a month that corresponds to the dry season.</p>
    <fig id="fig4" position="float">
     <label>Figure 4</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Figure 4. Location of piezometers in the study area.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId18.jpeg?20251028090953" />
    </fig>
    <p>The piezometric probe used is a Solinst TLC Meter model 107, 300 m long and mounted on a coil. It is ideal for profiling conductivity and temperature in piezometers for saltwater intrusion studies and a general indication of contamination levels. Conductivity and temperature readings are displayed on a rotating LCD screen on the face of the coil The depth of the water and the depth of the readings displayed are read off the tape. Conductivity accuracy is 5% of reading or 100 μS (whichever is greater). A light and buzzer are briefly activated when the zero point of the probe enters the water.</p>
    <p>The GARMIN Map64s GPS (Global Positioning System) is used to determine the coordinates (longitude, latitude and altitude) of the measurement points (piezometers).</p>
   </sec>
   <sec id="s3_2">
    <title>3.2. Groundwater Electrical Conductivity Measurements</title>
    <p>The probe is lowered progressively into the piezometer (vertical profiling) and measurements are taken in steps of approximately two (02) meters. At each depth, the electrical conductivity and the temperature values are displayed on the screen of the coil.</p>
    <p>The electrical conductivity of a liquid depends largely on its temperature. That’s why these two parameters were measured simultaneously. While standard temperatures such as 20˚C or 25˚C are used for calibrations with conductivity standards, conductivity measurements are generally carried out at different temperatures. Identifying water types from conductivity therefore requires recalculating the conductivity measured at a standard temperature, for example 25˚C. This correction is based on the following equation <xref ref-type="bibr" rid="scirp.146680-17">
      [17]
     </xref>:</p>
    <p>
     <math xmlns="http://www.w3.org/1998/Math/MathML"> <mrow> 
       <mi>
         E 
       </mi> 
       <msub> 
        <mi>
          C 
        </mi> 
        <mrow> 
         <mn>
           25 
         </mn> 
         <mo>
           ° 
         </mo> 
         <mi>
           C 
         </mi> 
        </mrow> 
       </msub> 
       <mo>
         = 
       </mo> 
       <mi>
         E 
       </mi> 
       <msub> 
        <mi>
          C 
        </mi> 
        <mi>
          T 
        </mi> 
       </msub> 
       <mo>
         × 
       </mo> 
       <msub> 
        <mi>
          F 
        </mi> 
        <mrow> 
         <mn>
           25 
         </mn> 
        </mrow> 
       </msub> 
      </mrow> 
     </math>(1)</p>
    <p>where: 
     <math xmlns="http://www.w3.org/1998/Math/MathML"> <mrow> 
       <mi>
         E 
       </mi> 
       <msub> 
        <mi>
          C 
        </mi> 
        <mi>
          T 
        </mi> 
       </msub> 
      </mrow> 
     </math> = the measured electrical conductivity et 
     <math xmlns="http://www.w3.org/1998/Math/MathML"> <mrow> 
       <msub> 
        <mi>
          F 
        </mi> 
        <mrow> 
         <mn>
           25 
         </mn> 
        </mrow> 
       </msub> 
      </mrow> 
     </math> = temperature correction factor.</p>
    <p>A classification of electrical conductivity has been established in order to define water types. This is the Milot and Renaud (2020) classification (<xref ref-type="table" rid="table1">
      Table 1
     </xref>).</p>
    <table-wrap id="table1">
     <label>
      <xref ref-type="table" rid="table1">
       Table 1
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Table 1. Classification of waters according to electrical conductivity <xref ref-type="bibr" rid="scirp.146680-18">
        [18]
       </xref>.</title>
     </caption>
     <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
      <tr> 
       <td class="custom-bottom-td acenter" width="35.02%"><p style="text-align:center">Water type</p></td> 
       <td class="custom-bottom-td acenter" width="49.16%"><p style="text-align:center">Electric conductivity (μS/cm)</p></td> 
      </tr> 
      <tr> 
       <td class="custom-top-td acenter" width="35.02%"><p style="text-align:center">Fresh water</p></td> 
       <td class="custom-top-td acenter" width="49.16%"><p style="text-align:center">EC &lt; 200</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="35.02%"><p style="text-align:center">Mineral water</p></td> 
       <td class="acenter" width="49.16%"><p style="text-align:center">200 ≤ EC ≤ 1000</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="35.02%"><p style="text-align:center">Salt water</p></td> 
       <td class="acenter" width="49.16%"><p style="text-align:center">EC ≥ 2000</p></td> 
      </tr> 
     </table>
    </table-wrap>
    <p>Water mineralization is assessed by measuring electrical conductivity. It is a good indicator of groundwater mineralization. This is because most of the dissolved matter in water is in the form of electrically charged ions <xref ref-type="bibr" rid="scirp.146680-8">
      [8]
     </xref>.</p>
    <p>In this study, Continental Terminal water mineralization is assessed by studying the spatial evolution of the electrical conductivity of water from this aquifer. Electrical conductivity data are acquired at each piezometer and along with six (06) aligned profiles (horizontal profiling) (<xref ref-type="table" rid="table2">
      Table 2
     </xref>). The horizontal profiles were defined according to the alignment and orientation of the piezometers.</p>
    <table-wrap id="table2">
     <label>
      <xref ref-type="table" rid="table2">
       Table 2
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Table 2. Piezometer profiles.</title>
     </caption>
     <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
      <tr> 
       <td class="custom-bottom-td acenter" width="12.81%"><p style="text-align:center">Profiles</p></td> 
       <td class="custom-bottom-td acenter" width="74.79%"><p style="text-align:center">Piezometers</p></td> 
      </tr> 
      <tr> 
       <td class="custom-top-td acenter" width="12.81%"><p style="text-align:center">1</p></td> 
       <td class="custom-top-td acenter" width="74.79%"><p style="text-align:center">PT1, PZ_C2D 26 et PZ_C2D 21</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="12.81%"><p style="text-align:center">2</p></td> 
       <td class="acenter" width="74.79%"><p style="text-align:center">PZ_C2D12, PZ_C2D13, PZ_C2D14, PZ19 et PZ_C2D47</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="12.81%"><p style="text-align:center">3</p></td> 
       <td class="acenter" width="74.79%"><p style="text-align:center">PZ_C2D 11, PZ_C2D 9 et PZ7_2010</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="12.81%"><p style="text-align:center">4</p></td> 
       <td class="acenter" width="74.79%"><p style="text-align:center">PZ_C2D 10, PZ1 et PZ7_2010</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="12.81%"><p style="text-align:center">5</p></td> 
       <td class="acenter" width="74.79%"><p style="text-align:center">PZ_C2D5, PZ_C2D10 et PZ_C2D2</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="12.81%"><p style="text-align:center">6</p></td> 
       <td class="acenter" width="74.79%"><p style="text-align:center">PZ_C2D4, PZ_C2D6, PZ_C2D7 et PZ_C2D8</p></td> 
      </tr> 
     </table>
    </table-wrap>
    <p>This study focuses on the horizontal spatialization of electrical conductivities in the surface part of the water table and on the distribution of electrical conductivities as a function of depth (vertical profiling).</p>
   </sec>
   <sec id="s3_3">
    <title>3.3. Data Processing</title>
    <p>Data processing was carried out with software. This software is chosen in accordance with the different objectives set. These are:</p>
   </sec>
  </sec><sec id="s4">
   <title>4. Results</title>
   <sec id="s4_1">
    <title>4.1. Analysis of Measured Temperatures</title>
    <p>
     <xref ref-type="table" rid="table3">
      Table 3
     </xref> shows low standard deviations overall. This reflects a high concentration of measured temperatures around their mean values. In fact, the almost zero standard deviation values indicate that the temperatures measured as a whole are similar. Also, the standard deviations of approximately one (01) obtained only at the level of three piezometers (PZ-C2D8, PZ-C2D9 and PZ-C2D12), means that the temperatures measured are distributed more or less uniformly over a range of one (01) unit.</p>
    <table-wrap id="table3">
     <label>
      <xref ref-type="table" rid="table3">
       Table 3
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Table 3. It summarizes the temperature statistics measured in the various piezometers.</title>
     </caption>
     <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
      <tr> 
       <td class="custom-bottom-td acenter" width="33.33%"><p style="text-align:center">Piezometers</p></td> 
       <td class="custom-bottom-td acenter" width="33.33%"><p style="text-align:center">Mean</p></td> 
       <td class="custom-bottom-td acenter" width="33.33%"><p style="text-align:center">Standard deviations</p></td> 
      </tr> 
      <tr> 
       <td class="custom-top-td acenter" width="33.33%"><p style="text-align:center">PZ C2D26</p></td> 
       <td class="custom-top-td acenter" width="33.33%"><p style="text-align:center">26.75</p></td> 
       <td class="custom-top-td acenter" width="33.33%"><p style="text-align:center">0.11</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D09</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">29.29</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">1.3</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D06</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.27</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.08</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D05</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.33</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.06</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D07</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.62</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.25</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D10</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.75</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.08</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ C2D08</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">25.18</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">1.56</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ 01</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.51</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.04</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ05</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.66</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.12</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D04</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.58</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.29</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D12</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">27.46</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">1.19</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ07-2010</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">27.33</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.64</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D21</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.01</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.26</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PT1</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">28.5</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.02</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D14</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.27</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.48</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D13</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.43</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.74</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D02</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">26.26</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.09</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZ19</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">28.52</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.08</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D48</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">27.78</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.48</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="33.33%"><p style="text-align:center">PZC2D47</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">27.01</p></td> 
       <td class="acenter" width="33.33%"><p style="text-align:center">0.52</p></td> 
      </tr> 
     </table>
    </table-wrap>
   </sec>
   <sec id="s4_2">
    <title>4.2. Spatial Evolution of Electrical Conductivity in the Surface Part of the Water Table</title>
    <p>Electrical conductivity measurements are analyzed according to their spatial distribution (mapping) and their behaviour at depth (electrical conductivity logs).</p>
    <p>The electrical conductivities measured in the first few meters of the piezometers are all low (less than 200 µS/cm). These values are typical of freshwater. However, their spatial distribution highlights three classes of electrical conductivity (<xref ref-type="fig" rid="fig5">
      Figure 5
     </xref>).</p>
    <fig id="fig5" position="float">
     <label>Figure 5</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Figure 5. Spatial distribution of electrical conductivity values in the surface part of the aquifer.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId25.jpeg?20251028090957" />
    </fig>
    <p>The first class, the most important in terms of surface area, is that of water with very low electrical conductivity (between 20 and 80 µS/cm). The second class is characterized by electrical conductivities ranging from 80 to 120 µS/cm and is located along the Ebrié lagoon to the west and between the Banco and Gbangbo rivers. Finally, the third class, comprising water from piezometers PT1, PZ_C2D 13 and PZ 19, is characterized by electrical conductivity values of between 120 and 200 µS/cm. This class is contained within the previous class. The piezometers in these last two classes are located downstream of surface water flows towards the Ebrié Lagoon (PT1) and Banco Bay (PZ_C2D 13, PZ_C2D 14 and PZ 19).</p>
    <p>The vertical variation of electrical conductivity was characterized using conductivity logs. The results are summarized in the appendix. These were analyzed using (6) aligned piezometer profiles (<xref ref-type="table" rid="table4">
      Table 4
     </xref>).</p>
    <table-wrap id="table4">
     <label>
      <xref ref-type="table" rid="table4">
       Table 4
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Table 4. Characteristics of the conductivity profiles.</title>
     </caption>
     <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
      <tr> 
       <td class="custom-bottom-td acenter" width="24.44%"><p style="text-align:center">Profile</p></td> 
       <td class="custom-bottom-td acenter" width="48.89%"><p style="text-align:center">Number of piezometers</p></td> 
       <td class="custom-bottom-td acenter" width="26.67%"><p style="text-align:center">Direction</p></td> 
      </tr> 
      <tr> 
       <td class="custom-top-td acenter" width="24.44%"><p style="text-align:center">1</p></td> 
       <td class="custom-top-td acenter" width="48.89%"><p style="text-align:center">3</p></td> 
       <td class="custom-top-td acenter" width="26.67%"><p style="text-align:center">SW-NE</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="24.44%"><p style="text-align:center">2</p></td> 
       <td class="acenter" width="48.89%"><p style="text-align:center">5</p></td> 
       <td class="acenter" width="26.67%"><p style="text-align:center">W-E</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="24.44%"><p style="text-align:center">3</p></td> 
       <td class="acenter" width="48.89%"><p style="text-align:center">3</p></td> 
       <td class="acenter" width="26.67%"><p style="text-align:center">NW-SE</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="24.44%"><p style="text-align:center">4</p></td> 
       <td class="acenter" width="48.89%"><p style="text-align:center">3</p></td> 
       <td class="acenter" width="26.67%"><p style="text-align:center">NW-SE</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="24.44%"><p style="text-align:center">5</p></td> 
       <td class="acenter" width="48.89%"><p style="text-align:center">3</p></td> 
       <td class="acenter" width="26.67%"><p style="text-align:center">NW-SE</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="24.44%"><p style="text-align:center">6</p></td> 
       <td class="acenter" width="48.89%"><p style="text-align:center">4</p></td> 
       <td class="acenter" width="26.67%"><p style="text-align:center">NW-SE</p></td> 
      </tr> 
     </table>
    </table-wrap>
    <p>It comprises piezometers PT1, PZ_C2D 26 and PZ_C2D 21. The electrical conductivity logs are shown in the appendix. Its values range from 30 to 1900 µS/cm. Piezometers PT1 and PZ_C2D 21 have very low electrical conductivity ranging from 30 to 200 µS/cm (PT1: 30 &lt; EC &lt; 74 µS/cm and PZ_C2D 21: 31 &lt; EC &lt; 250 µS/cm). It’s the same for the electrical conductivities of the CT sands at PZ_C2D 26, which range from 58 &lt; EC &lt; 66 µS/cm. However, there is a sudden jump in conductivity from 140 m corresponding to the depth of the bedrock. These electrical conductivities reach 1900 µS/cm, indicating the presence of brackish water.</p>
    <p>It includes piezometers PZ_C2D12, PZ_C2D13, PZ_C2D14, PZ19 and PZ_C2D47. The electrical conductivities range from 34 to 1600 µS/cm and the logs of electrical conductivity are shown in the appendix.</p>
    <p>The electrical conductivities of the water in the CT sands define two classes of water. “Fresh water”, relatively low (CECT &lt; 200 µS/cm), is found in all the piezometers except PZ19. Slightly higher conductivity values (200 &lt; CECT &lt; 1000 µS/cm) corresponding to “mineralized water” class were measured in piezometers PZ_C2D13, PZ19, PZ_C2D14, PZ_C2D12 and PZ_C2D47. This class is marked by significant and sudden variations of conductivity at 23 m and 80 m, 40 m, 80 m, 100 m and 138 m respectively.</p>
    <p>In the basement, brackish water is found in piezometers PZC2D12 and PZ_C2D13, at 120 m and 100 m respectively. These depths correspond to those of the basement.</p>
    <p>Three piezometers (PZ_C2D 11, PZ_C2D 9 and PZ7_2010) make up this profile. The electrical conductivity logs are shown in the appendix. Piezometers PZ_C2D 11 and PZ7_2010 record very low electrical conductivity values ranging from 33 to 200 µS/cm with depth. As for piezometer PZ_C2D 9, three (03) electrical conductivity classes are defined. These are:</p>
    <p>To sum up, the water in the CT for this profile is made up of fresh water, mineralized water and brackish and saline water.</p>
    <p>It comprises piezometers PZ_C2D 10, PZ1 and PZ7_2010. The electrical conductivity logs are shown in the appendix. The water in the CT is characterized by low electrical conductivity (29 to 94 µS/cm) and is classified as freshwater.</p>
    <p>It consists of piezometers PZ_C2D5, PZ_C2D10 and PZ_C2D2. The electrical conductivity logs are shown in the appendix. The water in the CT has very low electrical conductivity (30 - 62 µS/cm) to a depth of around 120 m. This electrical conductivity is characteristic of ‘fresh’ water. However, ‘weakly and moderately mineralized’ water, with electrical conductivity values of less than 1000 µS/cm, is encountered in PZ_C2D 5 and PZ_C2D2.</p>
    <p>Brackish water was also detected in piezometer PZ_C2D5 at a depth of 126 m. At this depth, the bedrock is found. Relatively high electrical conductivity values (1400 µS/cm) were measured from this depth.</p>
    <p>This profile consists of piezometers PZ_C2D4, PZ_C2D6, PZ_C2D7 and PZ_C2D8. The electrical conductivity logs are shown in the appendix. Low electrical conductivities were measured at depths of 32 m, 98 m, 47 m and 116 m. These depths correspond to those of the CT. We therefore conclude that at the level of this profile, the water in the CT is ‘fresh water’.</p>
    <p>Below, in the basement, the electrical conductivity values of the water indicate ‘moderately mineralized water’ and ‘brackish water’.</p>
    <p>Analysis of all the electrical conductivity logs indicates high electrical conductivity values (greater than 1000 µS/cm) in seven (07) piezometers (<xref ref-type="table" rid="table5">
      Table 5
     </xref>). These are piezometers PZ_C2D 26 (profile 1), PZ_C2D 12 and PZ_C2D 13 (profile 2), PZ_C2D 9 (profile 3), PZ_C2D 5 (profile 5), PZ_C2D 6 and PZ_C2D 7 (profile 6).</p>
    <table-wrap id="table5">
     <label>
      <xref ref-type="table" rid="table5">
       Table 5
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.146680-"></xref>Table 5. Summary of piezometers where saline intrusions have been observed.</title>
     </caption>
     <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
      <tr> 
       <td class="custom-bottom-td acenter" width="19.61%"><p style="text-align:center">Piezometers</p></td> 
       <td class="custom-bottom-td acenter" width="29.23%"><p style="text-align:center">Electrical conductivity range (µS/cm)</p></td> 
       <td class="custom-bottom-td acenter" width="17.05%"><p style="text-align:center">Base depth (m)</p></td> 
       <td class="custom-bottom-td acenter" width="17.05%"><p style="text-align:center">Intrusion zone</p></td> 
       <td class="custom-bottom-td acenter" width="17.06%"><p style="text-align:center">Water category</p></td> 
      </tr> 
      <tr> 
       <td class="custom-top-td acenter" width="19.61%"><p style="text-align:center">PZ_C2D 26</p></td> 
       <td class="custom-top-td acenter" width="29.23%"><p style="text-align:center">1000 à 1971</p></td> 
       <td class="custom-top-td acenter" width="17.05%"><p style="text-align:center">142</p></td> 
       <td class="custom-top-td acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="custom-top-td acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 13</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 1609</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">100</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 12</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 1639</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">120</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 9</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 3612</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">191</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">CT</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish and salty</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 5</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 1418</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">126</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 6</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 1744</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">98</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
      <tr> 
       <td class="acenter" width="19.61%"><p style="text-align:center">PZ_C2D 7</p></td> 
       <td class="acenter" width="29.23%"><p style="text-align:center">1000 à 1264</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">50</p></td> 
       <td class="acenter" width="17.05%"><p style="text-align:center">Basement</p></td> 
       <td class="acenter" width="17.06%"><p style="text-align:center">Brackish</p></td> 
      </tr> 
     </table>
    </table-wrap>
    <p>The CT waters have not yet been affected by the marine intrusion, the effects of which are perceptible at basement level with the presence of brackish waters. Only the CT waters at piezometer PZ_C2D 9 are brackish and saline.</p>
   </sec>
  </sec><sec id="s5">
   <title>5. Discussion</title>
   <p>The first electrical conductivity values were measured at the static level and are all less than or equal to 200 µS/cm. These values are characteristic of freshwater <xref ref-type="bibr" rid="scirp.146680-18">
     [18]
    </xref>. Although these waters are “fresh waters”, relatively high electrical conductivity values were measured in piezometers PT1, PZ_C2D 13, PZ_C2D 14 and PZ 19. These piezometers are located in the Banco bay and to the west of Songon Té village. They are also located downstream of groundwater flows. The piezometric levels in these piezometers are relatively low (between 2 and 38 m). Also, horizon 4 of the Continental Terminal also outcrops in the Banco valley <xref ref-type="bibr" rid="scirp.146680-19">
     [19]
    </xref>. All this creates favourable conditions for the exchange of water flows between surface water and the Continental Terminal aquifers and exposes the latter to organic pollution linked to wastewater discharges (ammonium, nitrate, etc.). The North-South conceptual model of the Continental Terminal aquifer in Abidjan indicates a hydrogeological relationship between the CT aquifer and the underlying crystalline and crystallophyllian basement <xref ref-type="bibr" rid="scirp.146680-19">
     [19]
    </xref>. This relationship is reflected by an interconnection of these two aquifers through a contact formation composed of clays, limestone, and sands. The presence of this horizon, particularly the clayey one, limits water exchanges between these aquifer levels.</p>
   <p>Brackish water is present in some piezometers. This could be explained by intrusions of water from the Ebrié and Aghien lagoons into these piezometers. These piezometers are located either near (less than 500 m) the Aghien lagoon (PZC2D 6 and PZC2D 7), or in the bays of the Ebrié lagoon (PZC2D 12, PZC2D 13 and PZC2D 9). In addition, the significant changes in electrical conductivity indicate an increase in the input of dissolved substances into the water in the piezometers. These substances are thought to be the result of anthropogenic pollution from wastewater draining into coastal rivers. Indeed, the work of <xref ref-type="bibr" rid="scirp.146680-20">
     [20]
    </xref> revealed that the mineralization of waters is due to the intrusion of lagoonal waters and/or to the infiltration of the streaming waters. That infiltration of superficial waters in the wells brings several minerals ions notably Cl<sup>−</sup>, Na<sup>+</sup>, K<sup>+</sup> and Mg<sup>2+</sup> and H<sup>+</sup> protons, as well as the organic matter. The addition of these ions contributes to the increase of their concentration in the groundwater.</p>
   <p>These cumulative effects may explain the brackish nature of the water in piezometer PZ_C2D 9 located in Adjamé-Bingerville village. Unlike the other six (06) piezometers, brackish water was found in the CT aquifer. The water quality in this locality will have to be better studied in order to determine the level of contamination caused by this pollution.</p>
  </sec><sec id="s6">
   <title>6. Conclusions</title>
   <p>At the end of this study, it was concluded that the surface water in the piezometers was fresh and generally of very low electrical conductivity (between 20 and 80 µS/cm). However, the piezometers located downstream of the surface water flows towards the Ebrié Lagoon (PT1) and Banco Bay contain water with increasingly high electrical conductivity (≈ 200 µS/cm). This is due to exchanges between surface water and groundwater, which expose the water in the piezometers to anthropogenic pollution.</p>
   <p>Depending on the depth, all the water in the CT is “fresh water”, except for that in piezometer PZ_C2D 9 located in Adjamé-Bingerville, where brackish and salty water is recorded. Also in the basement, brackish water was found in seven (07) piezometers (PZ_C2D 26, PZ_C2D 13, PZ_C2D 12, PZ_C2D 9, PZ_C2D 7, PZ_C2D 6 and PZ_C2D 5), located respectively along the Ebrié lagoon (Ayewahi-Anguédédou, western zone, Gourou downstream) and around the Aghien lagoon (Adjamé-Bingerville, Yacé, Elais, Bahouakoi).</p>
   <p>This study provides information on the quality of the waters of the Continental Terminal on the northern edge of the Ebrié Lagoon. These waters have not yet been affected by marine intrusion. However, the presence of brackish water found at greater depth (at the level of the bedrock) in some piezometers requires increased vigilance in the ongoing monitoring of the quality of these waters.</p>
  </sec><sec id="s7">
   <title>Acknowledgements</title>
   <p>This research was supported by the Hydrogeology and geophysics Research Group of the Geosciences and Environment Laboratory at Nangui Abrogoua University in Abidjan, Ivory Coast. The constructive and valuable comments of the anonymous readers and the Editor-in-Chief of the Journal are greatly appreciated.</p>
  </sec><sec id="s8">
   <title>Appendix: Conductivity Log Results for the March 2022 Campaign</title>
   <p>Vertical trend in electrical conductivity values for piezometers in profile 1.</p>
   <fig id="fig6" position="float">
    <label>Figure 6</label>
    <caption>
     <title>Vertical trend in electrical conductivity values for piezometers in profile 2.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/2313426-rId33.jpeg?20251028091002" /></p>Vertical trend in electrical conductivity values for piezometers in profile 3.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/2313426-rId34.jpeg?20251028091003" /></p>Vertical trend in electrical conductivity values for piezometers in profile 4.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/2313426-rId35.jpeg?20251028091002" /></p>Vertical trend in electrical conductivity values for piezometers in profile 5.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/2313426-rId36.jpeg?20251028091003" /></p>Vertical trend in electrical conductivity values for piezometers in profile 6.</title>
    </caption>
    <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/2313426-rId32.jpeg?20251028091002" />
   </fig>
  </sec>
 </body><back>
  <ref-list>
   <title>References</title>
   <ref id="scirp.146680-ref1">
    <label>1</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Shammas, M.I. and Jacks, G. (2007) Seawater Intrusion in the Salalah Plain Aquifer, Oman. Environmental Geology, 53, 575-587. &gt;https://doi.org/10.1007/s00254-007-0673-2
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref2">
    <label>2</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Xun, Z., Haiyan, Z. and Li, Z. (2007) Characteristics of Piezometric Heads and Determination of Fresh Water-Salt Water Interface in the Coastal Zone near Beihai, China. Environmental Geology, 54, 67-73. &gt;https://doi.org/10.1007/s00254-007-0793-8
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref3">
    <label>3</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Terzić, J., Marković, T. and Pekaš, Ž. (2007) Influence of Sea-Water Intrusion and Agricultural Production on the Blato Aquifer, Island of Korčula, Croatia. Environmental Geology, 54, 719-729. &gt;https://doi.org/10.1007/s00254-007-0841-4
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref4">
    <label>4</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Gone, L., Ligban, R., Kamagate, B., Saley, M. and Biemi, J. (2009) Processus hydrogéochimiques et origine des sources naturelles dans le degré carré de Daloa (Centre ouest de la Côte d’Ivoire). International Journal of Biological and Chemical Sciences, 3, 38-47. &gt;https://doi.org/10.4314/ijbcs.v3i1.42733
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref5">
    <label>5</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Jourda, J.P., Kouamé, K.J., Saley, M.B., Kouadio, B.H., Oga, Y.S. and Deh, S. (2006) Contamination of the Abidjan Aquifer by Sewage: An Assessment of Extent and Strategies for Protection. In: Xu, Y.X. and Usher, B., Eds., Groundwater Pollution in Africa, Taylor&amp;Francis/Balkema, 291-300.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref6">
    <label>6</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Dongo, K., Kouamé, F.K., Koné, B., Biém, J., Tanner, M. and Cissé, G. (2009) Analyse de la situation de l’environnement sanitaire des quartiers défavorisés dans le tissu urbain de Yopougon a Abidjan, Côte d’Ivoire. VertigO, 8, 1-10. &gt;https://doi.org/10.4000/vertigo.6252
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref7">
    <label>7</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     SOGREAH (1996) Etude de la gestion et de la protection de la nappe assurant l’alimentation en eau potable d’Abidjan. Etude sur modèle mathématique. Rapport de phase 1 et 2, République de Côte d’Ivoire, Ministère des infrastructures économiques, Direction et Contrôle des Grands Travaux (DGCTX), 22 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref8">
    <label>8</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Douagui, G.A., Kouamé, K.I., Koffi, K., Dibi, B., Konan, K.F. and Savané, I. (2010) Origines et modélisation de la minéralisation des eaux du Quaternaire d’Abidjan (Sud de la Côte d’Ivoire). International Journal of Biological and Chemical Sciences, 3, 856-869. &gt;https://doi.org/10.4314/ijbcs.v3i5.51049
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref9">
    <label>9</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Institut National de Statistiques (INS) (2022) Recensement Général de la Population et de l’Habitation (RGPH) 2021. Données socio-démographiques et économiques des localités, résultats primitifs par localités, région des lagunes, 13 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref10">
    <label>10</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Oga, M.S. (1998) Ressources en eaux souterraines dans la région du Grand-Abidjan (Côte d’Ivoire): Approches hydrochimique et isotopique. Thèse de Doctorat de l’Université de Paris XI Orsay, 211 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref11">
    <label>11</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Delor, C., Diaby, I., Siméon, Y., Yao, B., Tastet, J.P., Vidal, M., Chiron, J.P. and Dommanget, A. (1992) Notice explicative de la carte Géologique de la Côte d’Ivoire à 1/200000. Feuille Grand-Bassam. Mémoire de la Direction de la Géologie de Côte d’Ivoire, n°4, 30 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref12">
    <label>12</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Girard, G., Sircoulon, J. and Touchebeuf, P. (1971) Aperçu sur les régimes hydrologiques. Le milieu naturel de la Côte d’Ivoire. ORSTOM n°50, 109-156.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref13">
    <label>13</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Ahoussi, K.E. (2008) Evaluation quantitative et qualitative des ressources en eau dans le Sud de la Côte d’Ivoire. Application de l’hydrochimie et des isotopes de l’environnement à l’étude des aquifères continus et discontinus de la région d’Abidjan-Agboville. Thèse de Doctorat, Université de Cocody, 283 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref14">
    <label>14</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Dibi, B., Doumouya, I., N’Go, Y.A. and Goné, D.L. (2005) Origine et mécanisme de la minéralisation des eaux souterraines de la région de Dabou, Côte d’Ivoire. Apport de l’analyse en composantes principales normées. Revue internationale des sciences de la vie et de la terre, 5, 12 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref15">
    <label>15</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Aghui, N. and Biémi, J. (1984) Géologie et hydrogéologie des nappes de la région d’Abidjan. Risques de contamination. Annales de Côte d’Ivoire, série C (Sciences), 20, 313-347. 
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref16">
    <label>16</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Loroux, B.F.E. (1978) Contribution à l’étude hydrogéologique du bassin sédimentaire côtier de Côte d’Ivoire. Thèse de Doctorat de 3ème cycle, Université de Bordeaux I.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref17">
    <label>17</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Rodier, J., Legube, B., Merlet, N. and Alary C. (2009) L’analyse de l’eau, eaux naturelles, eaux résiduaires, eau de mer, chimie, physico-chimie, microbiologie, biologie, interprétation des résultats. 9th Edition, Dunod, 30 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref18">
    <label>18</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Milot, S. and Renaud, M. (2020) Suivi physicochimique des cours d’eau: Interprétation des paramètres physicochimiques mesurés pour le lac Létourneau. 16 p.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref19">
    <label>19</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Kouassi, K.A., Kouassi, F.W., Mangoua, O.M.J. and Savané, I. (2014) Modèle conceptuel de l’aquifère du Continental Terminal d’Abidjan. Hydrology in a Changing World: Environmental and Human Dimensions Proceedings of FRIEND-Water 2014, Montpellier, 7-10 October 2014, 256-262.
    </mixed-citation>
   </ref>
   <ref id="scirp.146680-ref20">
    <label>20</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Ahoulé, D.G., Ohou-Yao, M.J.A., Yapo O.B., Gnagne, A.E.J.E.Y. and Mambo, V. (2017) Caractérisation hydrochimique de la nappe phréatique de la ville d’Abidjan: Cas des communes d’Abobo, d’Attécoubé, de Koumassi et de Yopougon. Journal de la Société Ouest-Africaine de Chimie, 44, 51-57.
    </mixed-citation>
   </ref>
  </ref-list>
 </back>
</article>