<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">
    jdm
   </journal-id>
   <journal-title-group>
    <journal-title>
     Journal of Diabetes Mellitus
    </journal-title>
   </journal-title-group>
   <issn pub-type="epub">
    2160-5831
   </issn>
   <issn publication-format="print">
    2160-5858
   </issn>
   <publisher>
    <publisher-name>
     Scientific Research Publishing
    </publisher-name>
   </publisher>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="doi">
    10.4236/jdm.2025.153008
   </article-id>
   <article-id pub-id-type="publisher-id">
    jdm-143868
   </article-id>
   <article-categories>
    <subj-group subj-group-type="heading">
     <subject>
      Articles
     </subject>
    </subj-group>
    <subj-group subj-group-type="Discipline-v2">
     <subject>
      Medicine 
     </subject>
     <subject>
       Healthcare
     </subject>
    </subj-group>
   </article-categories>
   <title-group>
    Factors Affecting Continuous Glucose Monitoring Results: A Meta-Analysis
   </title-group>
   <contrib-group>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Wendong
      </surname>
      <given-names>
       Liao
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff1"> 
      <sup>1</sup>
     </xref>
    </contrib>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Cuiying
      </surname>
      <given-names>
       Mo
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff1"> 
      <sup>1</sup>
     </xref>
    </contrib>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Guoying
      </surname>
      <given-names>
       Lian
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff2"> 
      <sup>2</sup>
     </xref>
    </contrib>
    <contrib contrib-type="author" xlink:type="simple">
     <name name-style="western">
      <surname>
       Huiling
      </surname>
      <given-names>
       Liang
      </given-names>
     </name> 
     <xref ref-type="aff" rid="aff2"> 
      <sup>2</sup>
     </xref>
    </contrib>
   </contrib-group> 
   <aff id="aff1">
    <addr-line>
     aTaihe Town Health Center, Baiyun District, Guangzhou, China
    </addr-line> 
   </aff> 
   <aff id="aff2">
    <addr-line>
     aThe First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
    </addr-line> 
   </aff> 
   <pub-date pub-type="epub">
    <day>
     07
    </day> 
    <month>
     07
    </month>
    <year>
     2025
    </year>
   </pub-date> 
   <volume>
    15
   </volume> 
   <issue>
    03
   </issue>
   <fpage>
    107
   </fpage>
   <lpage>
    120
   </lpage>
   <history>
    <date date-type="received">
     <day>
      9,
     </day>
     <month>
      May
     </month>
     <year>
      2025
     </year>
    </date>
    <date date-type="published">
     <day>
      4,
     </day>
     <month>
      May
     </month>
     <year>
      2025
     </year> 
    </date> 
    <date date-type="accepted">
     <day>
      4,
     </day>
     <month>
      July
     </month>
     <year>
      2025
     </year> 
    </date>
   </history>
   <permissions>
    <copyright-statement>
     © Copyright 2014 by authors and Scientific Research Publishing Inc. 
    </copyright-statement>
    <copyright-year>
     2014
    </copyright-year>
    <license>
     <license-p>
      This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/
     </license-p>
    </license>
   </permissions>
   <abstract>
    Since its introduction, continuous glucose monitoring (CGM) has achieved good benefits in clinical blood glucose monitoring and self-blood glucose management for diabetic patients. However, during the usage process, there are various interfering factors, among which there are more or less controversial ones. This study evaluated the impact of these factors on the accuracy of continuous glucose monitoring (CGM). A meta-analysis was conducted on a type of observational study that used continuous glucose monitoring (CGM) to monitor blood glucose levels in individuals diagnosed with or undiagnosed for diabetes. A total of 526 articles were retrieved from four electronic databases. By using EndNeto software to exclude ineligible data, 425 articles were eliminated. For the remaining 101 articles, information such as the title, author, and publication year of each document was entered into the system, which automatically identified and excluded 14 duplicate studies. In the end, the remaining 87 articles were carefully reviewed. Of these 87 studies: 17 were animal experiments, 31 involved research on individuals under 18 years old, 14 were missing articles, and 15 were reviews. Ultimately, 11 studies met our requirements for analysis. The results of the heterogeneity test showed that the data was heterogeneous (χ
    <sup>2</sup>: 3438.01, I
    <sup>2</sup> = 99.7%, p = 0.266 &gt; 0.05). Statistical analysis was conducted using the fixed-effect model, and there was no publication bias. It is indicated that with the continuous update of science and technology, fewer and fewer factors that are considered likely to affect the results of continuous dynamic blood glucose monitoring will be reduced and eliminated. As a result, more advanced, convenient, efficient and accurate continuous dynamic blood glucose monitoring methods will benefit humanity. To provide an effective basis for accurately judging the blood glucose levels of diabetic patients, and to offer effective guidance for patients in aspects such as correct exercise, diet control, and pancreatic islet use in blood glucose self-management.
   </abstract>
   <kwd-group> 
    <kwd>
     Diabetic Patients
    </kwd> 
    <kwd>
      Continuous Dynamic Blood Glucose Monitoring
    </kwd> 
    <kwd>
      Influence
    </kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <sec id="s1">
   <title>1. Introduction</title>
   <p>Diabetes is a group of heterogeneous diseases, commonly characterized by elevated blood glucose levels, or hyperglycemia. It can be classified into Type 1 diabetes and Type 2 diabetes. Type 1 diabetes (T1DM) results from immune-mediated destruction of pancreatic β-cells, leading to impaired insulin secretion, and is mostly characterized by absolute insulin deficiency. Type 2 diabetes (T2DM) involves reduced insulin action (insulin resistance) along with progressive loss of β-cell function, typically starting as relative insulin deficiency. This often results in disrupted glucose-dependent insulin secretion by the receptors. Both types can develop into severe hyperglycemic symptoms such as polyuria, thirst, fatigue, unexplained weight loss, vision impairment, and increased risk of infections, ketoacidosis or non-ketotic hyperosmolar syndrome, with potential for coma. Chronic hyperglycemia can also lead to dysregulation of insulin secretion and/or action, and is associated with long-term damage and functional impairments of various tissues and organs (eyes, kidneys, nerves, heart, and blood vessels) as well as cancer.</p>
   <p>With the increasingly advanced development of treatment and monitoring technologies for diabetes patients domestically and internationally, there are some differences in the prevalence of diabetes across countries <xref ref-type="bibr" rid="scirp.143868-1">
     [1]
    </xref>. According to data from the National Health and Nutrition Examination Survey (NHANES) in the United States from 2013 to 2023, the prevalence of diabetes among adults has not shown a significant increase. However, patients who have been diagnosed with diabetes have experienced worsening conditions after 10 years. In China, the incidence of diabetes is also rising annually, with Type 2 diabetes (T2DM) being predominant <xref ref-type="bibr" rid="scirp.143868-2">
     [2]
    </xref>. It is particularly important to manage diabetes patients both in hospitals and at home due to the large number of cases. Poor management that leads to consistently high or low blood glucose levels in diabetes patients can cause irreversible damage to target organs and even result in life-threatening complications <xref ref-type="bibr" rid="scirp.143868-3">
     [3]
    </xref>. Therefore, it is crucial for diabetes patients to continuously and stably monitor their blood glucose levels and maintain them within the prescribed normal range. However, traditional blood glucose monitoring techniques often involve invasive procedures, causing discomfort and pain to patients, which decreases their compliance and motivation for self-monitoring. Diabetes patients need a precise and comfortable way to monitor blood glucose in order to improve their quality of life. The development of continuous glucose monitoring technology can address this issue and provide significant relief for such patients <xref ref-type="bibr" rid="scirp.143868-4">
     [4]
    </xref>.</p>
   <p>Continuous dynamic blood glucose monitoring (CGM) refers to the technology that continuously monitors glucose concentrations in the interstitial fluid of subcutaneous tissue through glucose sensors <xref ref-type="bibr" rid="scirp.143868-5">
     [5]
    </xref>. This technology provides continuous, comprehensive, and reliable 24-hour blood glucose information, helping to understand the trends and characteristics of blood glucose fluctuations. It enables effective blood glucose monitoring and better management for diabetes patients, and is favored by clinical patients, doctors, and nurses <xref ref-type="bibr" rid="scirp.143868-6">
     [6]
    </xref>. However, the results from continuous glucose monitoring (CGM) can also be influenced by certain factors <xref ref-type="bibr" rid="scirp.143868-4">
     [4]
    </xref>. This study aims to consider and eliminate these influencing factors, allowing for more systematic and optimized management of patients’ blood glucose levels. It involves a comprehensive systematic evaluation and analysis of recent research on CGM, providing a reliable evidence-based basis for clinical blood glucose management.</p>
  </sec><sec id="s2">
   <title>2. Methods</title>
   <sec id="s2_1">
    <title>2.1. Inclusion and Exclusion Criteria</title>
    <p>1) Inclusion Criteria: a) Participants aged ≥ 18 years; b) Populations diagnosed with diabetes or not yet diagnosed with diabetes; c) Diabetes patients who are receiving or not receiving treatment; d) Observational studies.</p>
    <p>2) Exclusion Criteria: a) Individuals who cannot understand or refuse to use continuous glucose monitoring; b) Less than 70% usage time of continuous glucose monitoring; c) Participants with impaired decision-making capacity or without decision-making capacity; d) Participants who have died or whose continuous glucose monitoring data is missing.</p>
   </sec>
   <sec id="s2_2">
    <title>2.2. Literature Retrieval Strategy</title>
    <p>Computer searches were conducted in PubMed, Embase, Web of Science, and the Cochrane Library, with a search period covering from the establishment of each database until March 2025. The search employed English subject terms combined with advanced search strategies. The search query was: Advanced search ((((((Continuous dynamic blood glucose monitoring, influence factor) OR (Interstitial fluid blood glucose, influence factor)) AND ((Continuous dynamic blood glucose monitoring, management) OR (Interstitial fluid blood glucose, management) OR (Freestyle Libre, influence factor) OR (Freestyle Libre, management)))))). Subject term search: “Continuous dynamic blood glucose monitoring” [Mesh] AND (influence factor, management). Search results yielded a total of 526 articles, which were included in the meta-analysis. The search process is illustrated in <xref ref-type="fig" rid="fig1">
      Figure 1
     </xref>.</p>
   </sec>
   <sec id="s2_3">
    <title>2.3. Search Results</title>
    <p>We retrieved a total of 526 articles from four electronic databases. Using EndNeto software, we excluded 425 ineligible articles. For the remaining 101 articles, we entered information such as the title, author, and publication year, and the system automatically identified and excluded 14 duplicate studies. Finally, we conducted an in-depth review of the remaining 87 articles. Among these: 17 were animal experiments, 31 were studies involving participants under 18 years old, 14 articles were missing, and 15 were reviews. Ultimately, 11 studies met our requirements and were included for analysis.</p>
    <p>
     <xref ref-type="bibr" rid="scirp.143868-"></xref></p>
    <fig id="fig1" position="float">
     <label>Figure 1</label>
     <caption>
      <title>Figure 1. Flowchart of literature screening.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId14.jpeg?20250707031535" />
    </fig>
   </sec>
   <sec id="s2_4">
    <title>2.4. Data Extraction</title>
    <p>The research team for this study consisted of four members. During the retrieval and analysis of articles, three researchers selected articles and extracted data based on inclusion and exclusion criteria. They then cross-verified the selections. If any contentious issues arose, the other three researchers were consulted to resolve them. Articles were preliminarily included by reviewing their titles and abstracts. After identifying and excluding duplicate articles, each article was then read in detail to finalize the selection of appropriate articles. Data were extracted from these chosen articles and included information such as: author, country, publication year, study type, sample size, statistical tests (M ± SD), and outcome indicators. This information was compiled into a summary table, such as <xref ref-type="table" rid="table1">
      Table 1
     </xref>. The primary outcome indicator was MARD (Mean Absolute Relative Difference); the smaller the value, the more accurately continuous glucose monitoring reflects glucose levels <xref ref-type="bibr" rid="scirp.143868-7">
      [7]
     </xref>. Secondary outcome indicators included Time in Range (TIR) %, Glycemic Variability (CG-MBY), Precision Absolute Relative Difference (PARD), etc. as detailed in <xref ref-type="table" rid="tableTables 1-4">
      Tables 1-4
     </xref>.</p>
    <table-wrap id="table1">
     <label>
      <xref ref-type="table" rid="table1">
       Table 1
      </xref></label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.143868-"></xref>Table 1. Diagram of general characteristics.</title>
     </caption>
    </table-wrap>
    <fig id="fig2" position="float">
     <label>Figure 2</label>
     <caption>
      <title>
       <xref ref-type="bibr" rid="scirp.143868-"></xref>Table 2. Article quality evaluation form.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId16.jpeg?20250707031536" /></p>2.5. Quality AssessmentThe methodological quality of non-randomized controlled trial designs was evaluated based on the Risk of Bias in Non-randomized Studies—of Interventions (ROBINS-I) tool, for quality assessment of the articles. The ROBINS-I scale uses a “dot system” to rate the included studies in three aspects: before intervention grouping, during intervention grouping, and after intervention grouping. The ratings include: Before intervention grouping—confounding bias, participant selection bias; During intervention grouping—intervention classification bias; After intervention grouping—bias due to deviations from intended interventions, missing data bias, outcome measurement bias, and selective reporting bias <xref ref-type="bibr" rid="scirp.143868-19">
        [19]
       </xref>. There are a total of seven components. If all components are rated as low risk, the study is considered low risk. If any component is rated as moderate, high, or very high risk, the study is determined to be of the highest level of risk. If any component is rated as no information, the study is defined as having no information. Specific ratings are detailed in <xref ref-type="table" rid="table5">
        Table 5
       </xref>.<xref ref-type="bibr" rid="scirp.143868-"></xref>Table 3. Article quality evaluation form.<p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId17.jpeg?20250707031537" /></p><xref ref-type="bibr" rid="scirp.143868-"></xref>Table 4. Article quality evaluation form.
       <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
 
        <tr> 
  
         <td class="acenter" width="10.36%"><p style="text-align:center"></p></td> 
  
         <td class="acenter" width="7.39%"><p style="text-align:center"></p></td> 
  
         <td class="acenter" width="10.36%"><p style="text-align:center"></p></td> 
  
         <td class="custom-bottom-td acenter" width="35.94%" colspan="3"><p style="text-align:center">Non-exposure group (control group)</p></td> 
  
         <td class="custom-bottom-td acenter" width="35.94%" colspan="3"><p style="text-align:center">Exposure group (Experimental group)</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="custom-bottom-td acenter" width="10.36%"><p style="text-align:center">Author</p></td> 
  
         <td class="custom-bottom-td acenter" width="7.39%"><p style="text-align:center">Year</p></td> 
  
         <td class="custom-bottom-td acenter" width="10.36%"><p style="text-align:center">Influencing factors</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">Non-exposure (experimental group) Sample size (control group)</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">Eating high-carbohydrate before exercise (MARD%)</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">High-carbohydrate intake: Standard difference before exercise</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">Exposure (experimental group) Sample size (control group)</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">Eating high-carbohydrate exercise (MARD%)</p></td> 
  
         <td class="custom-bottom-td custom-top-td acenter" width="11.98%"><p style="text-align:center">Eating high-carbohydrate exercise with standard difference during exercise</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="custom-top-td acenter" width="10.36%"><p style="text-align:center">Matzka M;</p></td> 
  
         <td class="custom-top-td acenter" width="7.39%"><p style="text-align:center">2024</p></td> 
  
         <td class="custom-top-td acenter" width="10.36%"><p style="text-align:center">Sports</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">199</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">15.7</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">14.1</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">101</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">17.1</p></td> 
  
         <td class="custom-top-td acenter" width="11.98%"><p style="text-align:center">13.6</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="10.36%"><p style="text-align:center">Bauhaus H;</p></td> 
  
         <td class="acenter" width="7.39%"><p style="text-align:center">2023</p></td> 
  
         <td class="acenter" width="10.36%"><p style="text-align:center">Sports</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">519</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">17</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">10</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">519</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">17</p></td> 
  
         <td class="acenter" width="11.98%"><p style="text-align:center">9</p></td> 
 
        </tr>

       </table><xref ref-type="bibr" rid="scirp.143868-"></xref>Table 5. Article overall quality evaluation form.
       <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
 
        <tr> 
  
         <td class="custom-bottom-td acenter" width="28.02%"><p style="text-align:center">Author</p></td> 
  
         <td class="custom-bottom-td acenter" width="21.56%"><p style="text-align:center">Year</p></td> 
  
         <td class="custom-bottom-td acenter" width="50.42%" colspan="2"><p style="text-align:center">Total offset risk assessment</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="custom-top-td acenter" width="28.02%"><p style="text-align:center">Kevin Hanson</p></td> 
  
         <td class="custom-top-td acenter" width="21.56%"><p style="text-align:center">2024</p></td> 
  
         <td class="custom-top-td acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId18.jpeg?20250707031537" /></p></p></td> 
  
         <td class="custom-top-td acenter" width="26.71%"><p style="text-align:center">Medium-risk bias</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Avari P</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2023</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId19.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">Medium-risk bias</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Toyota M</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2021</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId20.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">Medium-risk bias</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Narasaki Y</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2024</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId19.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">Low-risk bias</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Villard O</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2022</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId19.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">Low-risk bias</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Matzka M</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2024</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId21.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">No information</p></td> 
 
        </tr> 
 
        <tr> 
  
         <td class="acenter" width="28.02%"><p style="text-align:center">Villa-Tamayo</p></td> 
  
         <td class="acenter" width="21.56%"><p style="text-align:center">2024</p></td> 
  
         <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId22.jpeg?20250707031537" /></p></p></td> 
  
         <td class="acenter" width="26.71%"><p style="text-align:center">Medium-risk bias</p></td> 
 
        </tr>

       </table></title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId15.jpeg?20250707031536" />
    </fig>
    <p>Continued</p>
    <table class="MsoTableGrid custom-table" border="0" cellspacing="0" cellpadding="0"> 
     <tr> 
      <td class="acenter" width="28.02%"><p style="text-align:center">Bauhaus H</p></td> 
      <td class="acenter" width="21.56%"><p style="text-align:center">2023</p></td> 
      <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId23.jpeg?20250707031537" /></p></p></td> 
      <td class="acenter" width="26.71%"><p style="text-align:center">High-risk bias</p></td> 
     </tr> 
     <tr> 
      <td class="acenter" width="28.02%"><p style="text-align:center">Olafsdottir AF</p></td> 
      <td class="acenter" width="21.56%"><p style="text-align:center">2022</p></td> 
      <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId24.jpeg?20250707031537" /></p></p></td> 
      <td class="acenter" width="26.71%"><p style="text-align:center">High-risk bias</p></td> 
     </tr> 
     <tr> 
      <td class="acenter" width="28.02%"><p style="text-align:center">Eichenlaub M</p></td> 
      <td class="acenter" width="21.56%"><p style="text-align:center">2025</p></td> 
      <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId25.jpeg?20250707031537" /></p></p></td> 
      <td class="acenter" width="26.71%"><p style="text-align:center">Medium-risk bias</p></td> 
     </tr> 
     <tr> 
      <td class="acenter" width="28.02%"><p style="text-align:center">Pleus S</p></td> 
      <td class="acenter" width="21.56%"><p style="text-align:center">2022</p></td> 
      <td class="acenter" width="23.70%"><p style="text-align:center"><p class="imgGroupCss_v"><img class=" imgMarkCss lazy" data-original="https://html.scirp.org/file/4300890-rId26.jpeg?20250707031537" /></p></p></td> 
      <td class="acenter" width="26.71%"><p style="text-align:center">High-risk bias</p></td> 
     </tr> 
    </table>
    <p>Green <img height="20px" src="https://html.scirp.org/file/4300890-rId27.jpeg?20250707031537">: Low-risk bias; Yellow <img height="20px" src="https://html.scirp.org/file/4300890-rId28.jpeg?20250707031537">: Medium-risk bias; Red <img height="20px" src="https://html.scirp.org/file/4300890-rId29.jpeg?20250707031537">: High-risk bias; Black <img height="20px" src="https://html.scirp.org/file/4300890-rId30.jpeg?20250707031537">: Extremely high risk bias; Circle <img height="20px" src="https://html.scirp.org/file/4300890-rId31.jpeg?20250707031537">: No information. </img></img></img></img></img></p>
   </sec>
   <sec id="s2_5">
    <title>2.6. Data Collection and Statistical Analysis</title>
    <p>All included studies used consistent measurement tools, enabling a meta-analysis of combined quantitative data. The mean and standard deviation of the scores on the humanistic care ability scale in each study were summarized using Stata SE.14, and presented using weighted mean difference (WMD) effect sizes and 95% confidence intervals (CI). The Cochrane Q test and I<sup>2</sup> statistics were utilized with I<sup>2</sup> values of 25%, 50%, and 75%, indicating low, moderate, and high heterogeneity, respectively <xref ref-type="bibr" rid="scirp.143868-20">
      [20]
     </xref>. When I<sup>2</sup> &gt; 50%, and p &lt; 0.05, a random-effects model was used.</p>
   </sec>
  </sec><sec id="s3">
   <title>3. Results</title>
   <sec id="s3_1">
    <title>3.1. Overall Results</title>
    <p>Results, as shown in <xref ref-type="fig" rid="fig2">
      Figure 2
     </xref>, indicate that among the 11 studies that could affect continuous glucose monitoring (CGM) outcomes, the analysis produced χ<sup>2</sup>: 3438.01, I<sup>2</sup> = 99.7%, P = 0.266 &gt; 0.05. There were no significant differences in the effects of influencing factors between the groups.</p>
    <fig id="fig3" position="float">
     <label>Figure 3</label>
     <caption>
      <title>Figure 2. Forest plot of factors affecting continuous glucose monitoring.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId32.jpeg?20250707031539" />
    </fig>
   </sec>
   <sec id="s3_2">
    <title>3.2. Subgroup Analysis of the Study</title>
    <p>As shown in <xref ref-type="fig" rid="fig3">
      Figure 3
     </xref>, indicate that among the 11 studies that could affect continuous glucose monitoring (CGM) outcomes, the analysis yielded χ<sup>2</sup>: 2046.12, I<sup>2</sup> = 99.8%, P = 0.269 &gt; 0.05. There were no significant differences in the effects of influencing factors between the groups.</p>
    <fig id="fig4" position="float">
     <label>Figure 4</label>
     <caption>
      <title>Figure 3. Subgroup analysis of influencing factors of product performance in continuous ambulatory blood glucose monitoring results forest plot.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId33.jpeg?20250707031541" />
    </fig>
    <fig id="fig5" position="float">
     <label>Figure 5</label>
     <caption>
      <title>Figure 4. Subgroup analysis of influencing factors of hemodialysis based on continuous ambulatory glucose monitoring results, forest plot.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId34.jpeg?20250707031541" />
    </fig>
    <p>As a result, for example: <xref ref-type="fig" rid="fig4">
      Figure 4
     </xref>, among the 11 studies that might affect the results of continuous dynamic glucose monitoring (CGM), the analysis results showed that χ<sup>2</sup>: 30.7, I<sup>2</sup> = 93.8%, P = 0.413 &gt; 0.05. There is no difference in the effect of each influencing factor between groups.</p>
    <p>As shown in <xref ref-type="fig" rid="fig4">
      Figure 4
     </xref>, indicate that among the 11 studies that could affect continuous glucose monitoring (CGM) outcomes, the analysis yielded χ<sup>2</sup>: 0.62, I<sup>2</sup> = 0.0%, P = 0.432 &gt; 0.05 (see in <xref ref-type="fig" rid="fig5">
      Figure 5
     </xref>). There were no significant differences in the effects of influencing factors between the groups.</p>
    <fig id="fig6" position="float">
     <label>Figure 6</label>
     <caption>
      <title>Figure 5. Subgroup analysis of exercise influencing factors in continuous ambulatory glucose monitoring results Forest plot.</title>
     </caption>
     <graphic mimetype="image" position="float" xlink:type="simple" xlink:href="https://html.scirp.org/file/4300890-rId35.jpeg?20250707031542" />
    </fig>
   </sec>
  </sec><sec id="s4">
   <title>4. Discussion</title>
   <sec id="s4_1">
    <title>4.1. Product Performance</title>
    <p>With continuous technological advancements, the methods for continuous glucose monitoring (CGM) have been consistently updated and developed in numerous studies. These advancements have reduced interfering factors, improved monitoring signals and sensitivity, and even allowed for stable and accurate blood glucose readings in critically ill patients experiencing hypoxia. In recent years, many manufacturers have been committed to product improvements, calibration, algorithms, and technological updates, making CGM more precise and reliable <xref ref-type="bibr" rid="scirp.143868-21">
      [21]
     </xref>-<xref ref-type="bibr" rid="scirp.143868-27">
      [27]
     </xref>. This has facilitated easier self-management of blood glucose for patients, reducing pain and anxiety and increasing patient compliance with self-management. The stability of CGM provides clinical value for healthcare providers monitoring blood glucose in different patients, improving work efficiency and effectively preventing hypoglycemia <xref ref-type="bibr" rid="scirp.143868-28">
      [28]
     </xref>. It also offers healthcare professionals a reliable basis for clinically guiding patients in dietary and medication management <xref ref-type="bibr" rid="scirp.143868-29">
      [29]
     </xref>.</p>
   </sec>
   <sec id="s4_2">
    <title>4.2. Hemodialysis</title>
    <p>Diabetes is a leading cause of end-stage renal failure. Concerns have been raised about whether continuous glucose monitoring (CGM) results might be inaccurate in hemodialysis patients. However, analysis indicates that CGM accuracy is not impacted in these patients. In hemodialysis patients, CGM can effectively prevent adverse events such as hypoglycemia <xref ref-type="bibr" rid="scirp.143868-30">
      [30]
     </xref>. It also aids in guiding insulin medication during dialysis, providing valuable insights. CGM can be a significant benefit for blood glucose management in hemodialysis patients <xref ref-type="bibr" rid="scirp.143868-31">
      [31]
     </xref> <xref ref-type="bibr" rid="scirp.143868-32">
      [32]
     </xref>.</p>
   </sec>
   <sec id="s4_3">
    <title>4.3. Exercise</title>
    <p>Regarding exercise, there is some debate about whether it interferes with continuous glucose monitoring (CGM) results. Some studies suggest that exercise may impact CGM results, but this remains controversial <xref ref-type="bibr" rid="scirp.143868-33">
      [33]
     </xref> <xref ref-type="bibr" rid="scirp.143868-34">
      [34]
     </xref>. From the analysis, exercise does not appear to significantly affect the accuracy of the results. This could be related to product performance, as research indicates that the Dexcom G6 product shows better accuracy during exercise <xref ref-type="bibr" rid="scirp.143868-35">
      [35]
     </xref>.</p>
   </sec>
  </sec><sec id="s5">
   <title>5. Conclusion</title>
   <p>In summary, product performance, hemodialysis, and exercise do not excessively impact the accuracy of continuous glucose monitoring (CGM) results. Although some studies suggest that peritoneal dialysis, cardiac surgery, surgical operations, radiofrequency ablation, and high-altitude living environments can affect CGM results, the research is limited <xref ref-type="bibr" rid="scirp.143868-7">
     [7]
    </xref> <xref ref-type="bibr" rid="scirp.143868-36">
     [36]
    </xref>-<xref ref-type="bibr" rid="scirp.143868-39">
     [39]
    </xref>. There are no recent RCTs or observational studies to serve as the best evidence. In the future, we hope more similar studies will be published to provide a foundation for accurately assessing patient blood glucose levels in clinical settings.</p>
  </sec>
 </body><back>
  <ref-list>
   <title>References</title>
   <ref id="scirp.143868-ref1">
    <label>1</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Harreiter, J. and Roden, M. (2023) Diabetes Mellitus—Definition, Klassifikation, Diagnose, Screening Und Prävention (Update 2023). Wiener klinische Wochenschrift, 135, 7-17. &gt;https://doi.org/10.1007/s00508-022-02122-y 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref2">
    <label>2</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Inoue, K., Liu, M., Aggarwal, R., Marinacci, L.X. and Wadhera, R.K. (2025) Prevalence and Control of Diabetes among US Adults, 2013 to 2023. Journal of the American Medical Association, 333, 1255-1257. &gt;https://doi.org/10.1001/jama.2024.28513 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref3">
    <label>3</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Chinese Diabetes Society and Chinese Medical Association (2025) Guidelines for the Prevention and Treatment of Diabetes in China (2024 Edition). Chinese Journal of Diabetes, 17, 136-139.
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref4">
    <label>4</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Chinese Diabetes Society and Chinese Medical Association (2021) Clinical Application Guidelines for Blood Glucose Monitoring in China (2021 Edition). Chinese Journal of Diabetes, 13, 936-948.
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref5">
    <label>5</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Liu, Y.X. (2023) Development and Challenges of Wearable Flexible Continuous Glucose Monitoring Technology. Application of Electronic Technology, 12, 75-84.
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref6">
    <label>6</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Yang, M. (2023) Clinical Application and Research Progress of Continuous Glucose Monitoring Systems. Chinese Journal of Practical Internal Medicine, 8, 688-693.
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref7">
    <label>7</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Sun, Z., Du, Y., Wang, S., Sun, S., Ye, Y., Sun, X., et al. (2024) Accuracy of Freestyle Libre Flash Glucose Monitoring in Patients with Type 2 Diabetes Who Migrated from Highlands to Plains. World Journal of Diabetes, 15, 1254-1262. &gt;https://doi.org/10.4239/wjd.v15.i6.1254 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref8">
    <label>8</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Hanson, K., Kipnes, M. and Tran, H. (2024) Comparison of Point Accuracy between Two Widely Used Continuous Glucose Monitoring Systems. Journal of Diabetes Science and Technology, 18, 598-607. &gt;https://doi.org/10.1177/19322968231225676 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref9">
    <label>9</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Avari, P., Tang, W., Jugnee, N., Hersi, I., Al-Balah, A., Tan, T., et al. (2023) The Accuracy of Continuous Glucose Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA Study). Diabetes Technology&amp;Therapeutics, 25, 447-456. &gt;https://doi.org/10.1089/dia.2023.0013 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref10">
    <label>10</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Toyoda, M., Murata, T., Saito, N., Kimura, M., Takahashi, H., Ishida, N., et al. (2021) Assessment of the Accuracy of an Intermittent-Scanning Continuous Glucose Monitoring Device in Patients with Type 2 Diabetes Mellitus Undergoing Hemodialysis (AIDT2H) Study. Therapeutic Apheresis and Dialysis, 25, 586-594. &gt;https://doi.org/10.1111/1744-9987.13618 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref11">
    <label>11</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Narasaki, Y., Kalantar-Zadeh, K., Daza, A.C., You, A.S., Novoa, A., Peralta, R.A., et al. (2024) Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients with Diabetes. Diabetes Care, 47, 1922-1929. &gt;https://doi.org/10.2337/dc24-0635 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref12">
    <label>12</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Villard, O., Breton, M.D., Rao, S., Voelmle, M.K., Fuller, M.R., Myers, H.E., et al. (2022) Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals with Diabetes on Hemodialysis. Diabetes Care, 45, 1666-1669. &gt;https://doi.org/10.2337/dc22-0073 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref13">
    <label>13</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Matzka, M., Ørtenblad, N., Lenk, M. and Sperlich, B. (2024) Accuracy of a Continuous Glucose Monitoring System Applied Before, During, and after an Intense Leg-Squat Session with Low and High-Carbohydrate Availability in Young Adults without Diabetes. European Journal of Applied Physiology, 124, 3557-3569. &gt;https://doi.org/10.1007/s00421-024-05557-5 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref14">
    <label>14</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Villa-Tamayo, M.F., Builes-Montaño, C.E., Ramirez-Rincón, A., Carvajal, J. and Rivadeneira, P.S. (2022) Accuracy of an Off-Label Transmitter and Data Manager Paired with an Intermittent Scanned Continuous Glucose Monitor in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 18, 701-708. &gt;https://doi.org/10.1177/19322968221133405 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref15">
    <label>15</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Bauhaus, H., Erdogan, P., Braun, H. and Thevis, M. (2023) Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes. International Journal of Environmental Research and Public Health, 20, Article 6440. &gt;https://doi.org/10.3390/ijerph20156440 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref16">
    <label>16</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Ólafsdóttir, A.F., Andelin, M., Saeed, A., Sofizadeh, S., Hamoodi, H., Jansson, P., et al. (2022) Performance of Dexcom G5 and Freestyle Libre Sensors Tested Simultaneously in People with Type 1 or 2 Diabetes and Advanced Chronic Kidney Disease. World Journal of Clinical Cases, 10, 7794-7807. &gt;https://doi.org/10.12998/wjcc.v10.i22.7794 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref17">
    <label>17</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Eichenlaub, M., Waldenmaier, D., Wehrstedt, S., Pleus, S., Link, M., Jendrike, N., et al. (2025) Performance of Three Continuous Glucose Monitoring Systems in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 2025, 1-10. &gt;https://doi.org/10.1177/19322968251315459 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref18">
    <label>18</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Pleus, S., Stuhr, A., Link, M., Haug, C. and Freckmann, G. (2021) Variation of Mean Absolute Relative Differences of Continuous Glucose Monitoring Systems Throughout the Day. Journal of Diabetes Science and Technology, 16, 649-658. &gt;https://doi.org/10.1177/1932296821992373 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref19">
    <label>19</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Sterne, J.A., Hernán, M.A., Reeves, B.C., Savović, J., Berkman, N.D., Viswanathan, M., et al. (2016) ROBINS-I: A Tool for Assessing Risk of Bias in Non-Randomised Studies of Interventions. British Medical Journal, 355, i4919. &gt;https://doi.org/10.1136/bmj.i4919 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref20">
    <label>20</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Jiang, Q.Q., Zhang, Y., Qiao, L., Zha, Q.H., Xie, L. and Luo, Z.Z. (2022) A Cross-Sectional Survey and Analysis of Influencing Factors of Humanistic of the Current Status of Humanistic Care Ability of Burn Specialist Nurses. Chinese Journal of Burns and Wound Repair, 38, 1073-1078.
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref21">
    <label>21</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Sharifuzzaman, M., Shin, Y.D., Yoo, J., Reza, M.S., Kim, Y. and Park, J.Y. (2023) An Oxygen-Insensitive and Minimally Invasive Polymeric Microneedle Sensor for Continuous and Wide-Range Transdermal Glucose Monitoring. Talanta, 263, Article 124747. &gt;https://doi.org/10.1016/j.talanta.2023.124747 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref22">
    <label>22</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Fedulovs, A., Janevica, J., Kruzmane, L. and Sokolovska, J. (2024) Glucose Control and Variability Assessed by Continuous Glucose Monitoring in Patients with Type 1 Diabetes and Diabetic Kidney Disease. Biomedical Reports, 22, Article No. 23. &gt;https://doi.org/10.3892/br.2024.1901 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref23">
    <label>23</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     He, J., Cao, X., Liu, H., Liang, Y., Chen, H., Xiao, M., et al. (2023) Power and Sensitivity Management of Carbon Nanotube Transistor Glucose Biosensors. ACS Applied Materials&amp;Interfaces, 16, 1351-1360. &gt;https://doi.org/10.1021/acsami.3c17309 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref24">
    <label>24</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Pradhan, R., Chimene, D., Ko, B.S., Goncharov, A., Ozcan, A. and McShane, M.J. (2024) Insertable Biomaterial-Based Multianalyte Barcode Sensor toward Continuous Monitoring of Glucose and Oxygen. ACS Sensors, 9, 6060-6070. &gt;https://doi.org/10.1021/acssensors.4c01926 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref25">
    <label>25</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Tong, X., Jiang, T., Yang, J., Song, Y., Ao, Q., Tang, J., et al. (2025) Continuous Glucose Monitoring (CGM) System Based on Protein Hydrogel Anti-Biofouling Coating for Long-Term Accurate and Point-of-Care Glucose Monitoring. Biosensors and Bioelectronics, 277, Article 117307. &gt;https://doi.org/10.1016/j.bios.2025.117307 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref26">
    <label>26</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Zhu, W., Yu, H., Pu, Z., Guo, Z., Zheng, H., Li, C., et al. (2023) Effect of Interstitial Fluid Ph on Transdermal Glucose Extraction by Reverse Iontophoresis. Biosensors and Bioelectronics, 235, Article 115406. &gt;https://doi.org/10.1016/j.bios.2023.115406 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref27">
    <label>27</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Tingsarat, W., Buranasupkajorn, P., Khovidhunkit, W., Boonchaya-anant, P. and Laichuthai, N. (2021) The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit. Journal of Diabetes Science and Technology, 16, 1550-1554. &gt;https://doi.org/10.1177/19322968211027590 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref28">
    <label>28</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Šoupal, J., Kao, K., Brandner, L., Grunberger, G. and Prázný, M. (2023) Low Initial Adherence with Flash Glucose Monitoring Is Not a Predictor of Long-Term Glycemic Outcomes: Longitudinal Analysis of the Association between Experience, Adherence, and Glucose Control for Freestyle Libre Users. Diabetes Therapy, 14, 1231-1240. &gt;https://doi.org/10.1007/s13300-023-01422-4 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref29">
    <label>29</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Wright, J.J., Williams, A.J., Friedman, S.B., Weaver, R.G., Williams, J.M., Hodge, E., et al. (2022) Accuracy of Continuous Glucose Monitors for Inpatient Diabetes Management. Journal of Diabetes Science and Technology, 17, 1252-1255. &gt;https://doi.org/10.1177/19322968221076562 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref30">
    <label>30</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Cornet, S., Moranne, O., Jouret, F., Parotte, M.C., Georges, B., Godon, E., et al. (2024) Performance of an Interstitial Glucose Monitoring Device in Patients with Type 1 Diabetes during Haemodialysis. Clinical Kidney Journal, 17, sfae045. &gt;https://doi.org/10.1093/ckj/sfae045 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref31">
    <label>31</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Henry, Z., Villar, E., Chauvet, C., Belloi, A., Prunescu, I., Doroszewski, F., et al. (2024) Continuous Glucose Monitoring with Freestyle Libre PRO Sensor in Patients with Type 2 Diabetes and End-Stage Renal Failure on Haemodialysis (FSLPRO-DIAL Pilot Study). Acta Diabetologica, 61, 1537-1541. &gt;https://doi.org/10.1007/s00592-024-02323-z 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref32">
    <label>32</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Ling, J., Ng, J.K.C., Chan, J.C.N. and Chow, E. (2022) Use of Continuous Glucose Monitoring in the Assessment and Management of Patients with Diabetes and Chronic Kidney Disease. Frontiers in Endocrinology, 13, Article 869899. &gt;https://doi.org/10.3389/fendo.2022.869899 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref33">
    <label>33</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Da Prato, G., Pasquini, S., Rinaldi, E., Lucianer, T., Donà, S., Santi, L., et al. (2021) Accuracy of CGM Systems during Continuous and Interval Exercise in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 16, 1436-1443. &gt;https://doi.org/10.1177/19322968211023522 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref34">
    <label>34</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Mason, L.J., Hartwig, T. and Greene, D. (2024) Validating the Use of Continuous Glucose Monitors with Nondiabetic Recreational Runners. International Journal of Sports Physiology and Performance, 19, 1307-1313. &gt;https://doi.org/10.1123/ijspp.2024-0102 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref35">
    <label>35</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Maytham, K., Hagelqvist, P.G., Engberg, S., Forman, J.L., Pedersen-Bjergaard, U., Knop, F.K., et al. (2024) Accuracy of Continuous Glucose Monitoring during Exercise-Related Hypoglycemia in Individuals with Type 1 Diabetes. Frontiers in Endocrinology, 15, Article 1352829. &gt;https://doi.org/10.3389/fendo.2024.1352829 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref36">
    <label>36</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Ng, J.K.C., Ling, J., Luk, A.O.Y., Lau, E.S.H., Ma, R.C.W., Li, P.K.T., et al. (2023) Evaluation of a Fourth-Generation Subcutaneous Real-Time Continuous Glucose Monitor (CGM) in Individuals with Diabetes on Peritoneal Dialysis. Diabetes Care, 46, 1191-1195. &gt;https://doi.org/10.2337/dc22-2348 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref37">
    <label>37</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Gu, J., Zhao, Z., Li, H., Li, B., Chen, S., Cao, Y., et al. (2025) Accuracy of Freestyle Libre Continuous Glucose Monitoring System in Critically Ill Patients after Cardiac Surgery. Journal of Cardiothoracic Surgery, 20, Article No. 75. &gt;https://doi.org/10.1186/s13019-024-03229-1 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref38">
    <label>38</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Price, C.E., Fanelli, J.E., Aloi, J.A., Anzola, S.C., Vishneski, S.R., Saha, A.K., et al. (2023) Feasibility of Intraoperative Continuous Glucose Monitoring: An Observational Study in General Surgery Patients. Journal of Clinical Anesthesia, 87, Article 111090. &gt;https://doi.org/10.1016/j.jclinane.2023.111090 
    </mixed-citation>
   </ref>
   <ref id="scirp.143868-ref39">
    <label>39</label>
    <mixed-citation publication-type="other" xlink:type="simple">
     Shin, J., Jo, E., Woo, H.Y., Cho, A., Ko, M., Kim, S., et al. (2024) Perioperative Glucose Monitoring with Continuous Glucose Monitors Identifies Risk Factors for Post-Transplant Diabetes Mellitus in Kidney Transplant Recipients. Scientific Reports, 14, Article No. 21240. &gt;https://doi.org/10.1038/s41598-024-72025-7
    </mixed-citation>
   </ref>
  </ref-list>
 </back>
</article>