<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJO</journal-id><journal-title-group><journal-title>Open Journal of Orthopedics</journal-title></journal-title-group><issn pub-type="epub">2164-3008</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojo.2024.145020</article-id><article-id pub-id-type="publisher-id">OJO-133236</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Buechel Pappas Resurfacing Shoulder Replacement: Evolution and over 40 Years of Clinical Experience
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Frederick</surname><given-names>F. Buechel</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Michael</surname><given-names>J. Pappas</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Rutgers NJ Medical School, Newark, NJ, USA</addr-line></aff><aff id="aff2"><addr-line>New Jersey Institute of Technology, Newark, NJ, USA</addr-line></aff><pub-date pub-type="epub"><day>20</day><month>05</month><year>2024</year></pub-date><volume>14</volume><issue>05</issue><fpage>218</fpage><lpage>228</lpage><history><date date-type="received"><day>22,</day>	<month>March</month>	<year>2024</year></date><date date-type="rev-recd"><day>18,</day>	<month>May</month>	<year>2024</year>	</date><date date-type="accepted"><day>21,</day>	<month>May</month>	<year>2024</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  &lt;b&gt;Background:&lt;/b&gt; Early exploration of the semi constrained &amp;#8220;Floating-Socket&amp;#8221; total shoulder replacement (TSR) in 1974 led to a proliferation of various unconstrained designs that allowed resection or retention of the humeral head, depending upon the pathological process involved. Degenerative glenohumeral arthritis with mild to moderate involvement of subchondral bone allowed for a resurfacing option, while severe humeral head involvement required a partial or full humeral head replacement attached to an intramedullary stem for fixation. All components evolved from cemented to cementless application by 1982. The purpose of this paper is to describe the progression of Buechel-Pappas (B-P) shoulder replacement development from the early 1970&amp;#8217;s in both cemented and cement less applications. &lt;b&gt;Methods:&lt;/b&gt; Clinical evaluations of &amp;#8220;Floating-Socket&amp;#8221; TSR, followed by B-P stem-type, resurfacing types, bipolar-type and revision components, all of which comprise the B-P Shoulder Replacement System, were performed over a 49-year period. &lt;b&gt;R&lt;/b&gt;&lt;b&gt;e&lt;/b&gt;&lt;b&gt;sults:&lt;/b&gt; &amp;#8220;Floating-Socket&amp;#8221; implants improved the results of simple, constrained ball-in-socket designs, but generally failed by glenoid component loosening in both chimpanzee and human applications. Unconstrained resurfacing-type components, both anatomical humeral head and full proximal humeral components, were quite successful, with minimal failures observed in long-term studies. Bipolar salvage implants, used for severe proximal deficiencies, revisions and massive rotator cuff arthropathy, were also very successful; providing overhead range of motion in many patients. &lt;b&gt;Conclusions: &lt;/b&gt;Resurfacing hemiarthroplasty, in patients with intact or repairable rotator cuff mechanisms, gave the most satisfactory results and were the least technically complicated to perform, requiring minimal instrumentation. Resurfacing of full proximal humeral deficiencies, using femoral resurfacing components, gave similar clinical results to more complex semi-constrained devices, also with less technical difficulties and simple instrumentation.
 
</p></abstract><kwd-group><kwd>Total Shoulder Replacement</kwd><kwd> Resurfacing Shoulder Replacement</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Background</title><p>Early shoulder replacement designs by Krueger [<xref ref-type="bibr" rid="scirp.133236-ref1">1</xref>] and Neer [<xref ref-type="bibr" rid="scirp.133236-ref2">2</xref>] established a venue for replacing the proximal humerus in the event of complex fractures or degenerative arthritis. As further pathologies evolved, requiring improved stability, more constrained and semi-constrained devices were developed [<xref ref-type="bibr" rid="scirp.133236-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref4">4</xref>] . Fenlin developed a reverse-type shoulder replacement using a “ball &amp; socket” mechanism in 1973 [<xref ref-type="bibr" rid="scirp.133236-ref3">3</xref>] . DePalma, the chairman of the orthopaedic department at NJ Medical School, recruited a mechanical engineer, Michael J Pappas, PhD, in 1974 to collaborate with his research resident, Frederick F Buechel, MD, to evaluate his initial constrained designs and develop a semi-constrained TSR that they called the “floating socket”, since it was comprised of a sphere within a sphere with an offset pivot center, creating a “floating socket”! (See <xref ref-type="fig" rid="fig1">Figure 1</xref>). This patented device had 120˚ of motion and was attached by snap rings to a fixed glenoid component; making it one of the first “reverse” TSR’s [<xref ref-type="bibr" rid="scirp.133236-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref6">6</xref>] (see <xref ref-type="fig" rid="fig2">Figure 2</xref>). It was successful in both chimpanzee [<xref ref-type="bibr" rid="scirp.133236-ref7">7</xref>] and human [<xref ref-type="bibr" rid="scirp.133236-ref5">5</xref>] in the short term, but in the intermediate term (&gt;3 years) it failed by glenoid component loosening, even though one device lasted for 17 years in a rheumatoid female patient, see <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p>The lesson learned from the “floating-socket” device was that even semi-constrained devices can loosen by repetitive torque on glenoid fixation. This knowledge gave rise to minimizing or eliminating torque on fixation elements in our future designs. By uncoupling the humeral component from the glenoid component, and minimizing constraint in favor of soft tissue stabilization, component loosening in either cemented or cementless fixation was minimized.</p><p>Of interest, our initial cementless cobalt chrome resurfacing TSR, implanted in 1982, remained functional for over 26 years, until wear through of the ultra high molecular weight polyethylene (UHMWPe) bearing caused osteolysis and failure, see <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>In 1989, we changed from cobalt-chromium alloy to titanium nitride (TiN) ceramic coated titanium alloy resurfacing and stem-type components with porous coating for cementless fixation and created a system of stem-type and revision component as well (B-P Shoulder System, <xref ref-type="fig" rid="fig5">Figure 5</xref>). These highly polished and biocompatible components gave reasonable congruity to the arthritic glenoid surface and were surprisingly pain free. After observing wear failures of total stem-type TSR after 15 years using standard UHMWPe, see <xref ref-type="fig" rid="fig6">Figure 6</xref>, it stimulated the concept of hemiarthroplasty rather than TSR to avoid glenoid bearing</p><p>revision. This appealing concept allowed minimal contouring of the proximal humerus and gave long term (&gt;10 years) results that were equal to or superior to TSR, see <xref ref-type="fig" rid="fig7">Figure 7</xref> and <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><p>This historical context of design rationale and reviewing clinical results was essential to our understanding of loading concepts in the pursuit of refining implant design to compensate for stable or compromised rotator cuff mechanisms. Also, salvage situations required proximally porous coated stem-type fixation components to avoid stress shielding the humeral shaft. Overall, our early experience with constrained and semi-constrained devices led to loosening failures, which logically led us to unconstrain our implants in favor of soft tissue and anatomical constraints, rather than mechanical constraints.</p></sec><sec id="s2"><title>2. Methods</title><p>The B-P Shoulder Replacement System, see <xref ref-type="fig" rid="fig5">Figure 5</xref>, evolved from the “floating socket” TSR, see <xref ref-type="fig" rid="fig2">Figure 2</xref>, developed in 1974 [<xref ref-type="bibr" rid="scirp.133236-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref6">6</xref>] . This initial device was modified and implanted in an adult male chimpanzee in 1975 (see <xref ref-type="fig" rid="fig9">Figure 9</xref>), and followed for 3 years, when the animal died from complications of Crohn’s disease; the device was retrieved from the primate center post-mortem. The first human “floating socket” TSR was implanted in 1975 and was also followed for 3 years, when the 60 year old osteoarthritic male patient died from complications of liver cirrhosis; the device was retrieved with permission post-mortem.</p><p>B-P Resurfacing shoulder replacements were extensively studied by Pritchett [<xref ref-type="bibr" rid="scirp.133236-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref9">9</xref>] in both anatomic hemiarthroplasty and full proximal humeral hemiarthroplasty conditions, using femoral resurfacing implants, see <xref ref-type="fig" rid="fig1">Figure 1</xref>0. Bipolar shoulder replacements were studied by Worland [<xref ref-type="bibr" rid="scirp.133236-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref11">11</xref>] and used in salvage situations involved in loss of proximal humeral bone stock (see Figures 11-12).</p></sec><sec id="s3"><title>3. Results</title><p>Resurfacing Shoulder Arthroplasty, using polished TiN ceramic coated implants, has been extensively studied by Pritchett [<xref ref-type="bibr" rid="scirp.133236-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref9">9</xref>] . He recently reported on 428 patients with intact or reconstructable rotator cuff mechanisms that received a hemiarthroplasty and were followed for 5 to 30 years (mean 11 years), as well as 67 patients with rotator cuff arthropathy that received a hemiarthroplasty using a femoral resurfacing component, and were followed for a minimum of five years. He found that 94% of the former group had good to excellent results, while 90% preferred their resurfacing arthroplasty to a stem-type prosthesis already implanted in their contralateral shoulder. In the latter group, there were 9 patients with a reverse TSR in their opposite shoulder; 6 of 9 patients preferred their femoral resurfacing implant, stating that “it felt more natural”. Bipolar shoulder replacements were quite useful for severe proximal humeral deficiency or rotator cuff arthropathy, since the outer shell of the bipolar component filled the subacromial space, which provided stability and a fulcrum to allow stable abduction, see <xref ref-type="fig" rid="fig1">Figure 1</xref>3. No glenoid component was</p><p>needed for this articulation, in contrast to the “Reverse TSR” [<xref ref-type="bibr" rid="scirp.133236-ref4">4</xref>] that uses a semi-constrained large gleno-sphere, stabilized by multiple screws, which are constantly exposed to torquing forces.</p></sec><sec id="s4"><title>4. Discussion</title><p>Resurfacing shoulder replacement has been proven to be an effective surgical procedure to restore function and relieve pain. Extensive studies by Pritchett [<xref ref-type="bibr" rid="scirp.133236-ref8">8</xref>] have shown that polished TiN ceramic implants cause minimal wear on the native glenoid surface and are more wear-resistant than similar cobalt chromium devices, based on simulator and retrieval analyses.</p><p>His comparative studies of patients with bilateral shoulder replacements demonstrate the superiority of resurfacing implants over stem-type implants by patient preference [<xref ref-type="bibr" rid="scirp.133236-ref9">9</xref>] .</p><p>The journey of implant design from “floating-socket” to stem-type to the simplistic resurfacing type has required diligence and engineering expertise. The specific details of fabrication of the resurfacing humeral component and the resurfacing femoral component (Biocore9, Whippany, NJ) are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>4. Both devices have been cleared by the FDA 510K process [<xref ref-type="bibr" rid="scirp.133236-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.133236-ref14">14</xref>] .</p><p>Despite the complexity of resurfacing surgery, it is less invasive than implanting stem-type or reverse-type shoulder prostheses. There is also a lower infection rate and less overall complications using resurfacing implants [<xref ref-type="bibr" rid="scirp.133236-ref8">8</xref>] . In surgery, the old adage of “doing the least to gain the most” certainly applies to resurfacing shoulder hemiarthroplasty.</p></sec><sec id="s5"><title>5. Conclusions</title><p>Resurfacing shoulder hemiarthroplasty in patients with intact or reconstructable rotator cuff mechanisms had 94% good or excellent results at 5 - 30 years, mean 11 years.</p><p>Rotator cuff arthropathy patients that were reconstructed with femoral resurfacing components had results that were equal to, or better than, reverse TSR at a minimum of 5 years.</p><p>Resurfacing shoulder replacement surgery was observed to have fewer infections and fewer complications than stem-type shoulder replacements.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Buechel, F.F. and Pappas, M.J. (2024) Buechel Pappas Resurfacing Shoulder Replacement: Evolution and Over 40 Years of Clinical Experience. Open Journal of Orthopedics, 14, 218-228. https://doi.org/10.4236/ojo.2024.145020</p></sec></body><back><ref-list><title>References</title><ref id="scirp.133236-ref1"><label>1</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Kruger</surname><given-names> F.J. </given-names></name>,<etal>et al</etal>. (<year>1951</year>)<article-title>A Vitallium Replica Arthroplasty on the Shoulder: A Case Report of Aseptic Necrosis of the Proximal End of the Humerus</article-title><source> &lt;i&gt;Surgery&lt;/i&gt;</source><volume> 30</volume>,<fpage> 1005</fpage>-<lpage>1011</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.133236-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Neer, C.S. (1955) Articular Replacement of the Humeral Head. &lt;i&gt;JBJS&lt;/i&gt;, 37, 215-228.&lt;br&gt;https://doi.org/10.2106/00004623-195537020-00001</mixed-citation></ref><ref id="scirp.133236-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Fenlin, J. (1973) Total Glenohumeral Joint Replacement. &lt;i&gt;Medical Clinics of North America&lt;/i&gt;, 6, 565-583. &lt;br&gt;https://doi.org/10.1016/S0030-5898(20)31018-X</mixed-citation></ref><ref id="scirp.133236-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Cuff, D.J., Pupello, B.G., Santoni, R.T., &lt;i&gt;et &lt;/i&gt;&lt;i&gt;al.&lt;/i&gt; (2017) Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency: A Concise Follow-Up at a Minimum of 10 Years, of Previous Reports. &lt;i&gt;JBJS&lt;/i&gt;, 99, 1895-1899. &lt;br&gt;https://doi.org/10.2106/JBJS.17.00175</mixed-citation></ref><ref id="scirp.133236-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Buechel, F.F., Pappas, M.J. and DePalma, A.F. (1978) &amp;#8220;Floating Socket&amp;#8221; Total Shoulder Replacement: Anatomical, Biomechanical and Surgical Rationale. &lt;i&gt;Journal of Materials Research&lt;/i&gt;, 12, 89-114. &lt;br&gt;https://doi.org/10.1002/jbm.820120109</mixed-citation></ref><ref id="scirp.133236-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Buechel, F. and Pappas, M. (1975) Patent # 3,916,451. Floating Socket Joint. </mixed-citation></ref><ref id="scirp.133236-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Buechel, F.F. (1976) Shoulder Replacement in a Chimpanzee. &lt;i&gt;American Journal of Primatology&lt;/i&gt;, 6, 274-283. &lt;br&gt;https://doi.org/10.1159/000459759</mixed-citation></ref><ref id="scirp.133236-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Pritchett, J.W. (2023) Cementless Metal-Free Ceramic Coated Shoulder Resurfacing. &lt;i&gt;Journal of Personalized Medicine&lt;/i&gt;, 13, 25. &lt;br&gt;https://doi.org/10.3390/jpm13050825</mixed-citation></ref><ref id="scirp.133236-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Pritchett, J.W. (2011) Long-Term Results and Patient Satisfaction after Shoulder Resurfacing. &lt;i&gt;Journal of Shoulder and Elbow Surgery&lt;/i&gt;, 20, 771-777. &lt;br&gt;https://doi.org/10.1016/j.jse.2010.08.014</mixed-citation></ref><ref id="scirp.133236-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Worland, R.L. and Arredondo, J. (1998) Bipolar Arthroplasty for Painful Conditions of the Shoulder. &lt;i&gt;Journal of Shoulder and Elbow Surgery&lt;/i&gt;, 13, 631-637.&lt;br&gt;https://doi.org/10.1016/S0883-5403(98)80005-3</mixed-citation></ref><ref id="scirp.133236-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Arredondo, J. and Worland, R.L. (1999) Bipolar Shoulder Arthroplasty in Patients with Osteoarthritis: Short-Term Clinical Results and Evaluation of Birotational Head Motion. &lt;i&gt;Journal of Shoulder and Elbow Surgery&lt;/i&gt;, 8, 425-429. &lt;br&gt;https://doi.org/10.1016/S1058-2746(99)90071-X</mixed-citation></ref><ref id="scirp.133236-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Buechel, F.F. and Pappas, M.J. (2015) Principles of Human Joint Replacement: Design and Clinical Application. 2nd Edition. Springer, Switzerland, 375-431.&lt;br&gt;https://doi.org/10.1007/978-3-319-15311-7</mixed-citation></ref><ref id="scirp.133236-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Biocore9 (2020) FDA 510K #K193122. Biocore9 Humeral Head Resurfacing Component.</mixed-citation></ref><ref id="scirp.133236-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Biocore9 (2021) FDA 510K #K201219. Biocore9 Femoral Head Resurfacing Component.</mixed-citation></ref></ref-list></back></article>