<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">WJET</journal-id><journal-title-group><journal-title>World Journal of Engineering and Technology</journal-title></journal-title-group><issn pub-type="epub">2331-4222</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/wjet.2023.114045</article-id><article-id pub-id-type="publisher-id">WJET-128030</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Design and Data Analysis of a New Type of Antifreezing Cup-Type Wind Velocity Sensor
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jiajia</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jianguang</surname><given-names>Han</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jianan</surname><given-names>Yin</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zheng</surname><given-names>Liu</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ting</surname><given-names>Ma</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Hebei Provincial Meteorological Technology Equipment Center, Shijiazhuang, China</addr-line></aff><aff id="aff2"><addr-line>Hengshui City Meteorological Bureau, Hengshui, China</addr-line></aff><aff id="aff3"><addr-line>Hebei Provincial Meteorological Disaster Prevention and Environmental Meteorology Center, Shijiazhuang, China</addr-line></aff><pub-date pub-type="epub"><day>21</day><month>09</month><year>2023</year></pub-date><volume>11</volume><issue>04</issue><fpage>672</fpage><lpage>681</lpage><history><date date-type="received"><day>23,</day>	<month>August</month>	<year>2023</year></date><date date-type="rev-recd"><day>24,</day>	<month>September</month>	<year>2023</year>	</date><date date-type="accepted"><day>27,</day>	<month>September</month>	<year>2023</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In most areas of China, affected by the environment of low temperature and high humidity, the wind speed sensor and wind direction sensor are frozen and cannot output data in autumn, winter or the alternation of winter and spring. In order to solve the freezing situation of the wind sensor, this paper designs a new type of antifreeze wind speed sensor. After meteorology performance testing and field observation tests, the correlation coefficient of the 
  observation data is demonstrated, and the data curve is fitted. The result shows the sensor is stable, and has a good antifreeze effect, the data output is reliable.
 
</p></abstract><kwd-group><kwd>Automatic Weather Station</kwd><kwd> Wind Speed Sensor</kwd><kwd> Wind Direction Sensor</kwd><kwd> Freeze</kwd><kwd> Cold-Resistant Technology</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The measurement of wind elements is one of the important elements of meteorological ground observation. Wind is a three-dimensional vector superimposed on large-scale regular air flow by many small-scale pulsations that vary randomly in time and space [<xref ref-type="bibr" rid="scirp.128030-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.128030-ref2">2</xref>] . Because in most areas of China, autumn, winter or the alternation of winter and spring, affected by low temperature and high humidity environment, wind speed and direction sensor easily freeze and are unable to output sensor data. Once the wind sensor is frozen, the wind measurement data in the region will be missing. If the fault cannot be removed in time, it will inevitably have a serious impact on the forecast and meteorological service [<xref ref-type="bibr" rid="scirp.128030-ref3">3</xref>] .</p><p>At present, the most effective measures to solve the frozen wind sensors are as follows: maintenance personnel go to the site, put down the wind pole or climb the wind tower for detection [<xref ref-type="bibr" rid="scirp.128030-ref4">4</xref>] . Especially in winter, the tower is covered with thin ice, and climbing the tower for troubleshooting causes certain safety risks, and the troubleshooting and maintenance of automatic weather stations in remote areas are more inconvenient. In order to cope with the freezing phenomenon of wind sensors, many scholars have conducted in-depth studies and proposed sensor heating devices to solve the freezing problem of wind sensors. However, the experimental results are not satisfactory. Due to the increase of uncertainty introduced by heating devices [<xref ref-type="bibr" rid="scirp.128030-ref5">5</xref>] , the maintenance cost and difficulty have been increased.</p><p>By analyzing the frozen position of the wind speed sensor and considering the drainage angle, velocity and fluid dynamics [<xref ref-type="bibr" rid="scirp.128030-ref6">6</xref>] , this paper proposes an anti-freezing cup-type wind speed sensor based on mechanical principle. After passing through the 40 m/s wind tunnel laboratory, The measurement performance meets the requirements of Verification Regulations for Wind Direction and Speed Sensors of Automatic Weather Stations (JJG (Meteorological) 004-2011) [<xref ref-type="bibr" rid="scirp.128030-ref7">7</xref>] . Subsequently, field experiments are carried out in Zhangjiakou and Chengde of Hebei Province, and the experimental results are good.</p></sec><sec id="s2"><title>2. Design Principle</title><p>The cup-type wind speed sensor is an instrument used to measure the wind speed and convert it into an electrical pulse signal. It has a wide range of applications, such as meteorological stations, ships, oil platforms, environmental protection, etc [<xref ref-type="bibr" rid="scirp.128030-ref8">8</xref>] . The antifreeze sensor designed in this paper is composed of the components of the wind cup, the shell and the socket. The protective cover arranged at the upper end of the working part, the connecting shaft arranged in the working part and running through the protective cover, and the induction element in the connecting shaft constitute the key components of the equipment [<xref ref-type="bibr" rid="scirp.128030-ref9">9</xref>] . Its external structure is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>Both the input and output of the sensor adopt transient suppression diodes for overload protection, as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. Wind speed measurement uses a low-inertia wind cup component as the sensing component, which rotates with the wind and drives the wind speed code disc to carry out photoelectric scanning</p><p>and output the corresponding electrical pulse signal [<xref ref-type="bibr" rid="scirp.128030-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.128030-ref11">11</xref>] . The external protective cover is made of corrosion-resistant materials and protected by spraying layer. The seal uses a labyrinth structure and O-rings to protect the sensitive elements inside the instrument from harsh environments [<xref ref-type="bibr" rid="scirp.128030-ref3">3</xref>] .</p></sec><sec id="s3"><title>3. Measurement Performance Test</title><p>The designed wind speed sensor has the following parameter requirements, as shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><sec id="s3_1"><title>3.1. Test Condition</title><sec id="s3_1_1"><title>3.1.1. Verification Using Measuring Standard Devices</title><p>Standard Name: First class compensatory micropressure gauge standard device.</p><p>Measurement Range: (0 - &#177;1500) Pa.</p><p>Accuracy Level: First Class.</p></sec><sec id="s3_1_2"><title>3.1.2. Antifreeze Type Wind Speed Sensor</title><p>Unit Type: EL15.</p><p>Measurement Range: 0 m/s - 40 m/s.</p></sec><sec id="s3_1_3"><title>3.1.3. Environmental Conditions</title><p>Temperature: 15˚C - 30˚C.</p><p>Humidity: 30% RH - 70% RH.</p><p>Atmospheric Pressure: 900 hPa - 1100 hPa.</p><p>Selection of Experimental Points: Starting Wind Speed, 1 m/s, 2 m/s, 5 m/s, 10 m/s, 15 m/s, 20 m/s, 25 m/s, 30 m/s.</p></sec></sec><sec id="s3_2"><title>3.2. Start-Up Wind Speed Test</title><p>When the wind speed sensor can overcome the friction torque and air resistance moment on the rotation axis, the speed at which rotation begins is the starting wind speed. The starting wind speed of the whole experiment section (0 m/s - 40 m/s) is less than 0.5 m/s, which meets the requirements of the Verification Regulations of Wind Direction and Speed Sensors of Automatic Weather Stations (JJG (Meteorological) 004-2011).</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Parameter specifications</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >environmental conditions</th><th align="center" valign="middle" >−40˚C - 60˚C 0% - 100% RH</th></tr></thead><tr><td align="center" valign="middle" >working voltage</td><td align="center" valign="middle" >DC5V</td></tr><tr><td align="center" valign="middle" >weight</td><td align="center" valign="middle" >1 kg</td></tr><tr><td align="center" valign="middle" >boundary dimension</td><td align="center" valign="middle" >319 mm &#215; 225 mm</td></tr><tr><td align="center" valign="middle" >measurement range</td><td align="center" valign="middle" >0 m/s - 60 m/s</td></tr><tr><td align="center" valign="middle" >maximum permissible errors</td><td align="center" valign="middle" >&#177;(0.5 + 0.03 V) m/s (Note: V is the indicated wind speed)</td></tr><tr><td align="center" valign="middle" >start-up wind speed</td><td align="center" valign="middle" >0.5 m/s</td></tr><tr><td align="center" valign="middle" >resolving ability</td><td align="center" valign="middle" >0.1 m/s</td></tr><tr><td align="center" valign="middle" >wind velocity output</td><td align="center" valign="middle" >0 Hz - 1221 Hz</td></tr><tr><td align="center" valign="middle" >intensity of draft</td><td align="center" valign="middle" >75 m/s</td></tr></tbody></table></table-wrap></sec><sec id="s3_3"><title>3.3. Wind Speed Comparison Experiment</title><p>Two ordinary cup-type wind speed sensors and two new anti-freezing cup-type wind speed sensors were selected for experimental analysis and comparison.</p><p>Instrument Model: EL15-1C;</p><p>Instrument Number: 14110761756;</p><p>Experimental Result: For details, see <xref ref-type="table" rid="table2">Table 2</xref>.</p><p>According to the error of comparison experiment, the error curve of indication value is drawn, as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p>The anti-freezing wind speed sensor is 77.8% better than the ordinary wind speed sensor. This may mean that the function of the anti-freezing wind speed sensor is more reliable and the measurement of wind speed is more accurate.</p><p>Instrument Model: EL15-1A;</p><p>Instrument Number: 13120721887;</p><p>Experimental Result: For details, see <xref ref-type="table" rid="table3">Table 3</xref>.</p><p>According to the error of comparison experiment, the error curve of indication value is drawn, as shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>The anti-freezing wind speed sensor was optimized by 66.7% compared with the ordinary wind speed sensor. When compared with ordinary sensors, certain aspects of the frost-resistant sensor have been optimized. This may refer to possible improvements such as cost reduction.</p><p>Instrument Model: EL15-1E;</p><p>Instrument Number: 17040770049;</p><p>Experimental Result: For details, see <xref ref-type="table" rid="table4">Table 4</xref>.</p><p>According to the error of comparison experiment, the error curve of indication value is drawn, as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>.</p><p>The anti-freezing wind speed sensor was optimized by 88.9% compared with the ordinary wind speed sensor.</p><p>Through the comparison of the laboratory data of the above three models, the new antifreeze wind speed sensor has different degrees of optimization than the</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Wind tunnel test data (1C)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Micromanometer indicating value (Pa)</th><th align="center" valign="middle" >Standardized wind speed V indicating value (m/s)</th><th align="center" valign="middle" >Normal wind speed (V1)</th><th align="center" valign="middle" >Antifreeze typewind speedsensor (V2)</th><th align="center" valign="middle" >Indication error (ΔV1)</th><th align="center" valign="middle" >Indication error (ΔV2)</th></tr></thead><tr><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >0.30</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >0.34</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >0.04</td></tr><tr><td align="center" valign="middle" >0.46</td><td align="center" valign="middle" >0.91</td><td align="center" valign="middle" >1.06</td><td align="center" valign="middle" >1.04</td><td align="center" valign="middle" >0.15</td><td align="center" valign="middle" >0.13</td></tr><tr><td align="center" valign="middle" >2.49</td><td align="center" valign="middle" >2.11</td><td align="center" valign="middle" >2.16</td><td align="center" valign="middle" >2.13</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >0.02</td></tr><tr><td align="center" valign="middle" >13.56</td><td align="center" valign="middle" >4.93</td><td align="center" valign="middle" >5.02</td><td align="center" valign="middle" >5.03</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >0.10</td></tr><tr><td align="center" valign="middle" >54.85</td><td align="center" valign="middle" >9.92</td><td align="center" valign="middle" >10.31</td><td align="center" valign="middle" >10.29</td><td align="center" valign="middle" >0.39</td><td align="center" valign="middle" >0.37</td></tr><tr><td align="center" valign="middle" >125.51</td><td align="center" valign="middle" >15.00</td><td align="center" valign="middle" >15.59</td><td align="center" valign="middle" >15.50</td><td align="center" valign="middle" >0.59</td><td align="center" valign="middle" >0.50</td></tr><tr><td align="center" valign="middle" >223.15</td><td align="center" valign="middle" >20.00</td><td align="center" valign="middle" >20.55</td><td align="center" valign="middle" >20.61</td><td align="center" valign="middle" >0.55</td><td align="center" valign="middle" >0.61</td></tr><tr><td align="center" valign="middle" >348.45</td><td align="center" valign="middle" >25.00</td><td align="center" valign="middle" >25.89</td><td align="center" valign="middle" >25.87</td><td align="center" valign="middle" >0.89</td><td align="center" valign="middle" >0.87</td></tr><tr><td align="center" valign="middle" >504.66</td><td align="center" valign="middle" >30.08</td><td align="center" valign="middle" >31.04</td><td align="center" valign="middle" >31.01</td><td align="center" valign="middle" >0.96</td><td align="center" valign="middle" >0.93</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Wind tunnel test data (1A)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Micromanometer indicating value (Pa)</th><th align="center" valign="middle" >Standardized wind speed V indicating value (m/s)</th><th align="center" valign="middle" >Normal wind speed (V1)</th><th align="center" valign="middle" >Antifreeze typewind speedsensor (V2)</th><th align="center" valign="middle" >Indication error (ΔV1)</th><th align="center" valign="middle" >Indication error (ΔV2)</th><th align="center" valign="middle" ></th></tr></thead><tr><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >0.23</td><td align="center" valign="middle" >0.42</td><td align="center" valign="middle" >0.32</td><td align="center" valign="middle" >0.19</td><td align="center" valign="middle"  colspan="2"  >0.09</td></tr><tr><td align="center" valign="middle" >0.53</td><td align="center" valign="middle" >0.97</td><td align="center" valign="middle" >1.08</td><td align="center" valign="middle" >1.08</td><td align="center" valign="middle" >0.11</td><td align="center" valign="middle"  colspan="2"  >0.11</td></tr><tr><td align="center" valign="middle" >2.47</td><td align="center" valign="middle" >2.10</td><td align="center" valign="middle" >2.09</td><td align="center" valign="middle" >2.16</td><td align="center" valign="middle" >-0.01</td><td align="center" valign="middle"  colspan="2"  >0.06</td></tr><tr><td align="center" valign="middle" >14.16</td><td align="center" valign="middle" >5.02</td><td align="center" valign="middle" >4.95</td><td align="center" valign="middle" >5.02</td><td align="center" valign="middle" >-0.07</td><td align="center" valign="middle"  colspan="2"  >0.00</td></tr><tr><td align="center" valign="middle" >56.34</td><td align="center" valign="middle" >10.01</td><td align="center" valign="middle" >10.18</td><td align="center" valign="middle" >10.03</td><td align="center" valign="middle" >0.17</td><td align="center" valign="middle"  colspan="2"  >0.02</td></tr><tr><td align="center" valign="middle" >127.56</td><td align="center" valign="middle" >15.06</td><td align="center" valign="middle" >15.55</td><td align="center" valign="middle" >15.56</td><td align="center" valign="middle" >0.49</td><td align="center" valign="middle"  colspan="2"  >0.50</td></tr><tr><td align="center" valign="middle" >225.06</td><td align="center" valign="middle" >20.00</td><td align="center" valign="middle" >20.66</td><td align="center" valign="middle" >20.54</td><td align="center" valign="middle" >0.66</td><td align="center" valign="middle"  colspan="2"  >0.54</td></tr><tr><td align="center" valign="middle" >354.24</td><td align="center" valign="middle" >25.09</td><td align="center" valign="middle" >25.67</td><td align="center" valign="middle" >25.64</td><td align="center" valign="middle" >0.58</td><td align="center" valign="middle"  colspan="2"  >0.55</td></tr><tr><td align="center" valign="middle" >505.85</td><td align="center" valign="middle" >29.98</td><td align="center" valign="middle" >30.80</td><td align="center" valign="middle" >30.82</td><td align="center" valign="middle" >0.82</td><td align="center" valign="middle"  colspan="2"  >0.84</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Wind tunnel test data (1E)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Micromanometer indicating value (Pa)</th><th align="center" valign="middle" >Standardized wind speed V indicating value (m/s)</th><th align="center" valign="middle" >Normal wind speed (V1)</th><th align="center" valign="middle" >Antifreeze typewind speedsensor (V2)</th><th align="center" valign="middle" >Indication error (ΔV1)</th><th align="center" valign="middle" >Indication error (ΔV2)</th></tr></thead><tr><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >0.27</td><td align="center" valign="middle" >0.10</td><td align="center" valign="middle" >0.20</td><td align="center" valign="middle" >−0.17</td><td align="center" valign="middle" >−0.07</td></tr><tr><td align="center" valign="middle" >0.53</td><td align="center" valign="middle" >0.98</td><td align="center" valign="middle" >0.80</td><td align="center" valign="middle" >0.85</td><td align="center" valign="middle" >−0.18</td><td align="center" valign="middle" >−0.13</td></tr><tr><td align="center" valign="middle" >2.52</td><td align="center" valign="middle" >2.13</td><td align="center" valign="middle" >1.90</td><td align="center" valign="middle" >1.90</td><td align="center" valign="middle" >−0.23</td><td align="center" valign="middle" >−0.23</td></tr><tr><td align="center" valign="middle" >13.61</td><td align="center" valign="middle" >4.94</td><td align="center" valign="middle" >4.70</td><td align="center" valign="middle" >4.80</td><td align="center" valign="middle" >−0.24</td><td align="center" valign="middle" >−0.14</td></tr><tr><td align="center" valign="middle" >54.72</td><td align="center" valign="middle" >9.91</td><td align="center" valign="middle" >10.10</td><td align="center" valign="middle" >10.10</td><td align="center" valign="middle" >0.19</td><td align="center" valign="middle" >0.19</td></tr><tr><td align="center" valign="middle" >123.45</td><td align="center" valign="middle" >14.89</td><td align="center" valign="middle" >15.30</td><td align="center" valign="middle" >15.40</td><td align="center" valign="middle" >0.41</td><td align="center" valign="middle" >0.51</td></tr><tr><td align="center" valign="middle" >223.99</td><td align="center" valign="middle" >20.06</td><td align="center" valign="middle" >20.90</td><td align="center" valign="middle" >20.80</td><td align="center" valign="middle" >0.84</td><td align="center" valign="middle" >0.74</td></tr><tr><td align="center" valign="middle" >346.29</td><td align="center" valign="middle" >24.94</td><td align="center" valign="middle" >25.90</td><td align="center" valign="middle" >25.89</td><td align="center" valign="middle" >0.96</td><td align="center" valign="middle" >0.95</td></tr><tr><td align="center" valign="middle" >503.73</td><td align="center" valign="middle" >30.08</td><td align="center" valign="middle" >31.40</td><td align="center" valign="middle" >31.38</td><td align="center" valign="middle" >1.32</td><td align="center" valign="middle" >1.30</td></tr></tbody></table></table-wrap><p>ordinary wind speed sensor, and its indication error result has obvious advantages, which is closer to the real measurement value.</p></sec></sec><sec id="s4"><title>4. Observation Field Test</title><sec id="s4_1"><title>4.1. Trial Site</title><p>The preliminary pilot test was carried out in Zhangbei County Meteorological</p><p>Bureau, Guyuan County Meteorological Bureau, Chengde Longhua County Meteorological Bureau and Luanping County Meteorological Bureau. The trial will run from September 1 to November 30, 2021.</p></sec><sec id="s4_2"><title>4.2. Test Content</title><p>The test instrument was installed in the position of the existing wind speed sensor in the backup station, the existing wind speed sensor was replaced, and the data of the wind speed sensor in the active main station was compared.</p></sec><sec id="s4_3"><title>4.3. Test Results</title><p>Based on the wind speed observation data of Zhangbei County, Guyuan County, Longhua County, Luanping County Meteorological Bureau in September 2020 and September 2021, the wind speed data of upload station and backup station were processed, and the wind speed changes of traditional wind speed sensor and anti-freezing wind speed sensor in the same month in different years were analyzed in detail.</p><p>Based on the wind speed data of the four test sites, the wind speed changes and correlation coefficients of the upload station and backup station in 2020, the wind speed curves and correlation coefficients of the upload station and backup station in 2021, the difference between the upload station and 2021, and the difference between the backup station and 2020 are respectively compared, as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>.</p><p>In general, in September 2020 and mid-September 2021, the change trend of wind speed at the upload station and backup station over time is basically the same, with good consistency.</p><p>From <xref ref-type="fig" rid="fig6">Figure 6</xref>(B) of the four test sites, it can be seen that compared with the traditional wind speed sensor of the upload station, the wind speed evolution trend of the anti-freezing wind speed sensor of the backup station in September</p><p>2021 is basically the same with time, and has a good correlation. It is worth noting that the correlation coefficient of the wind speed data of the upload station and the backup station in Guyuan and Luanping in 2021 even increased slightly.</p></sec></sec><sec id="s5"><title>5. Conclusion</title><p>In summary, the antifreeze cup-type wind speed sensor has excellent performance in the measurement performance experiment and observation field test. In the comparison of ordinary wind speed sensors, the average optimization rate of metrology performance reached 77.8%. In the field test, the antifreeze wind speed sensor had a good correlation with the ordinary wind speed sensor, and even slightly improved than the previous data.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Zhang, J.J., Han, J.G., Yin, J.N., Liu, Z. and Ma, T. (2023) Design and Data Analysis of a New Type of Antifreezing Cup-Type Wind Velocity Sensor. World Journal of Engineering and Technology, 11, 672-681. https://doi.org/10.4236/wjet.2023.114045</p></sec></body><back><ref-list><title>References</title><ref id="scirp.128030-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Chen, T. and Yang, T. (2017) Discussion on Linear Extension Method of Calibration Value of Cup-Type Wind Velocity Sensor. Electronic Measurement Technology, 40, 238-241. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Yan, X.L., Wang, B.Q., Lu, H.Q., et al. (2012) Research on Verification and Calibration Method of Wind Velocity Sensor. Journal of Chengdu University of Information Engineering, 27, 335-348. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Wei, Y.F., Ma, K., Bai, J.G., et al. (2020) Influence of Environmental Parameter Change on Wind Velocity Verification. Instruments for Meteorology, Hydrology and Oceanography, 37, 21-23. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Chen, T., Zhang, H., Zheng, L., et al. (2016) Experiment on Traceability and Transmission Method of Wind Speed Calibration in Automatic Weather Station. Meteorological Science and Technology, 44, 678-694. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Y., Wu, C., Zhang, J.J., et al. (2016) Study on the Influence of Verification Environment on the Standard Value of Anemometer. Foreign Electronic Measurement Technology, 35, 72-75. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Guo, J.L., Bai, J.S. and Feng, J. (2012) Research on Calibration Method of Wind Velocity Sensor Using Vortex Street Principle in Coal Mine. Journal of Electronic Measurement and Instrument, 26, 125-127. (In Chinese)</mixed-citation></ref><ref id="scirp.128030-ref7"><label>7</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Li</surname><given-names> J.Y. </given-names></name>,<etal>et al</etal>. (<year>2019</year>)<article-title>Field Calibration Method of Cup-Type Wind Velocity Sensor</article-title><source> Meteorological Science and Technology</source><volume> 47</volume>,<fpage> 752</fpage>-<lpage>756</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.128030-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Tian, R. (2020) Optimization of Output Characteristics of MEMS Thermal Wind Speed and Direction Sensor. Ph.D. Thesis, Southeast University, Nanjing.</mixed-citation></ref><ref id="scirp.128030-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Li, X.D. and Luo, H.J. (2018) Processing Process of Data Deviation of Primary Wind Velocity Sensor. Guangdong Meteorology, 40, 78-80.</mixed-citation></ref><ref id="scirp.128030-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Lv, C.Y., Zhao, Z.J. and Zhang, X.L. (2018) Design and Performance Test of Low Speed and High Temperature Wind Tunnel. Energy Research and Information, 34, 51-55.</mixed-citation></ref><ref id="scirp.128030-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Lei, X.M., Wu, L., Han, Y.T., et al. (2020) Uncertainty Analysis and Evaluation of Impeller Digital Anemometer Based on GUM. Foreign Electronic Measurement Technology, 39, 30-34.</mixed-citation></ref></ref-list></back></article>