<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JASMI</journal-id><journal-title-group><journal-title>Journal of Analytical Sciences, Methods and Instrumentation</journal-title></journal-title-group><issn pub-type="epub">2164-2745</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jasmi.2023.133003</article-id><article-id pub-id-type="publisher-id">JASMI-127423</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Vibrational Spectroscopy of Pain Relievers: Traditional and Remote Raman Techniques
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Aschalew</surname><given-names>Kassu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Damoni</surname><given-names>Robinson</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Chemistry, Alabama State University, Montgomery, AL, USA</addr-line></aff><aff id="aff1"><addr-line>Department of Mechanical, Civil Engineering &amp;amp; Construction Management, Alabama A &amp;amp; M University, Normal, AL, USA</addr-line></aff><pub-date pub-type="epub"><day>30</day><month>08</month><year>2023</year></pub-date><volume>13</volume><issue>03</issue><fpage>27</fpage><lpage>37</lpage><history><date date-type="received"><day>18,</day>	<month>July</month>	<year>2023</year></date><date date-type="rev-recd"><day>28,</day>	<month>August</month>	<year>2023</year>	</date><date date-type="accepted"><day>31,</day>	<month>August</month>	<year>2023</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The application of vibrational spectroscopy in the pharmaceutical industry is widely investigated, from the quality assurance of the product during the production process control to the final products’ quality control and the authentication of products on the markets. This study focuses on non-contact and noninvasive detection and identification of pain-relievers at 1-5 meters standoff distances. The specimens analyzed include standard laboratory-
  grade active ingredients and commercially available pain relievers in powder, solid and liquid forms. All the remote measurements captured revealed the Raman signatures of the specimens, with varying peak intensities. To correlate the band intensities captured with the standoff distances between the laser source and the specimens, the intensity ratios of the two prominent peaks of the laboratory grade reference active ingredient (1607 and 1319 cm<sup>-1</sup>) normalized with 1319 cm<sup>-1</sup> are used. The results of the study suggest the viability of standoff Raman spectroscopy for routine monitoring and identification of pharma-ceuticals, including counterfeit pain relievers.
 
</p></abstract><kwd-group><kwd>Raman Spectroscopy</kwd><kwd> Acetaminophen</kwd><kwd> Aspirin</kwd><kwd> Standoff Raman</kwd><kwd> Vibrational Spectroscopy</kwd><kwd> Pain Relievers</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Raman spectroscopy is a powerful technique that uses vibrational energy levels of materials of interest to create a spectrum unique to every material. This uniqueness could be displayed in terms of the spectral position and intensity of various Raman bands. Conventional Raman spectroscopy is widely used as a research tool for routine quality control, analysis, and characterization of materials. This is likely due to the fact that conventional Raman spectroscopy involves analyzing samples from a close distance of a few millimeters. Standoff Raman spectroscopy involves analyzing samples from distances of a few centimeters up to hundreds of meters and has recently proven to be a very valuable tool in detecting explosives, atmospheric pollutants, and minerals [<xref ref-type="bibr" rid="scirp.127423-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref2">2</xref>] . Raman spectroscopy has also been used in food science, to detect adulterants used in food [<xref ref-type="bibr" rid="scirp.127423-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref6">6</xref>] . In earlier work, the technique has been demonstrated to detect commercially motivated adulteration of extra virgin olive oil with 10 percent canola, grape seed, and sunflower oils, without removing the oil from the container [<xref ref-type="bibr" rid="scirp.127423-ref6">6</xref>] . Using an 11-inches telescope integrated with a 785 nm laser source placed at 250 meters standoff distance from the specimen, Sadate et al., detected nitrates powder [<xref ref-type="bibr" rid="scirp.127423-ref7">7</xref>] . One of the benefits of the remote Raman spectroscopy technique, demonstrated here in the present work, is that it is contactless with the sample, the advantage of collecting the Raman spectra remotely without removing the drug from the containers. As most of the containers for pharmaceutical drugs/pain relievers are transparent, the laser beam can easily pass through the containers and capture the Raman spectra of the drugs. This makes the technique viable for routine monitoring and identification of pharmaceuticals, including counterfeit medicines. The application and efficiency of the remote Raman spectroscopy system for real-time detection and identification of explosives and other hazardous chemicals of interest, air pollution monitoring, and planetary and geological mineral analysis at various standoff distances have been demonstrated [<xref ref-type="bibr" rid="scirp.127423-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref4">4</xref>] . However, the application of the standoff Raman technique for the characterization of pharmaceutical drugs has not been explored. This work demonstrates the adequacy of the traditional and standoff Raman techniques for detecting, identifying, and analyzing acetaminophen-containing drugs and over-the-counter pain relievers.</p><p>In the pharmaceutical industry, Raman spectroscopy has been used for industrial process monitoring, quality control of products, detection and identification of counterfeit medicines. The technique has several benefits, including short acquisition time, no complex sample preparation required, non-destructive, non-invasive, and in cases the container or package is transparent, the spectra could be acquired without removing the material from their package [<xref ref-type="bibr" rid="scirp.127423-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref11">11</xref>] . Yves Roggo et al., used chemometrics coupled with Raman spectroscopy to discriminate counterfeits pharmaceutical tablets [<xref ref-type="bibr" rid="scirp.127423-ref12">12</xref>] . The authors developed a calibration curve to identify families of different tablets with calibration of the same active pharmaceutical ingredient (API) but containing different concentrations to discriminate counterfeit drugs from genuine ones [<xref ref-type="bibr" rid="scirp.127423-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref12">12</xref>] . The application of vibrational spectroscopy in the pharmaceutical industry is broad, including process monitoring and control, authenticating drugs, and identifying drugs inside the packages [<xref ref-type="bibr" rid="scirp.127423-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref10">10</xref>] . It has also been used for investigating photo-sensitivity and the degradation of active ingredients in pharmaceutical drugs [<xref ref-type="bibr" rid="scirp.127423-ref13">13</xref>] . Handheld Raman systems can also effectively distinguish falsified pharmaceutical products from authentic active pharmaceutical ingredients and the authenticity of commercial tablets [<xref ref-type="bibr" rid="scirp.127423-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref15">15</xref>] .</p></sec><sec id="s2"><title>2. Literature Review</title><p>The application of Raman spectroscopy in the pharmaceutical industry is widely investigated, from the quality assurance of the product during the production process control to the final products’ quality control and the authentication of products on the markets [<xref ref-type="bibr" rid="scirp.127423-ref16">16</xref>] . Kim et al. (2007) used Raman spectroscopy to measure the concentration of povidone, also called polyvinylpyrrolidone, used as a lubricant in commercially available eye drops. The Raman spectra were collected by launching a wide area laser beam through a low-density polyethylene (LDPE) plastic container. Partial least square regression analysis of the spectra was used to estimate the concentration of povidone, an active pharmaceutical ingredient in a commercial eye wash solution in LDPE bottles.</p><p>Chetan et al., used Raman spectroscopy to demonstrate the ability of the system to identify and quantify a mixture of four different drugs (acetaminophen, lidocaine, azithromycin, and epinephrine) and their degradation products [<xref ref-type="bibr" rid="scirp.127423-ref17">17</xref>] . The samples were prepared by grinding to finely powdered particle sizes, vortex mixed and again grounded to improve homogeneity. However, Vankeirbbilck et al., suggested that crushing and grinding specimens can alter the solid state property of materials [<xref ref-type="bibr" rid="scirp.127423-ref8">8</xref>] . High pressure applied to pharmaceutical drugs like aspirin is known to produce new polymorphic phases having different intra- and inter-molecular arrangements, changing the functionality and performance of the drug [<xref ref-type="bibr" rid="scirp.127423-ref18">18</xref>] . The effect of high-pressure phase change and eventual changes in the bonding and the arrangement of the structural groups of polymorphic phases of aspirin with varying chemical and physical properties are studied using micro-Raman spectroscopy [<xref ref-type="bibr" rid="scirp.127423-ref18">18</xref>] . The micro-Raman system described in Crowell et al., is used to examine the stability and detect the bonding and molecular and structural changes resulting due to high-pressure imposed on aspirin [<xref ref-type="bibr" rid="scirp.127423-ref18">18</xref>] . The primary benefit of using Raman spectroscopy in the current study is the fact that no sample preparation and removal of the specimens from the bottle or package is required to acquire the measurements at standoff distances. In some other techniques, for instance, where sample preparation requires grinding, the process changes the properties of the inherent solid states, including the chemical bonding of the active ingredient to be tested [<xref ref-type="bibr" rid="scirp.127423-ref8">8</xref>] . The measurements can be acquired non-invasively without removing the sample from the package or causing any damage to the specimens. However, the intensity of the Raman spectra depends on the color and material of the package or bottles and the distance between the probe and the specimens.</p><p>Raman spectroscopy, coupled with multivariate statistical analysis of the spectra acquired from finger marks of suspects in contact with prescription and over-the-counter nonsteroidal anti-inflammatory drug traces, is also used for chemical analysis and criminal investigation of suspects in contact with drug traces [<xref ref-type="bibr" rid="scirp.127423-ref19">19</xref>] . The technique is reported to have tremendous benefits in narrowing down the pool of suspects for criminal investigation. Xuejia Zhao et al., demonstrated the application of Transmission Raman Spectroscopy (TRS) in the pharmaceutical manufacturing industry coupled with the statistical design of experiment and partial least square model for monitoring the quality of drugs during the production stage [<xref ref-type="bibr" rid="scirp.127423-ref20">20</xref>] . The model developed is used to monitor the pharmaceutical production process and predict the concentration of active ingredients in marketed paracetamol tablets. As compared with the standard spectrophotometry and chromatography, vibrational spectroscopy-based analytical techniques for the detection and identification of commercial drugs/tablets, such as acetaminophen, is advantageous due to the ease in sample preparation and rapid processing and analysis showing the molecular compositions of the specimens [<xref ref-type="bibr" rid="scirp.127423-ref21">21</xref>] . As covered in this section, earlier works reported the viability of vibrational spectroscopy for the analysis and screening of pharmaceutical drugs [<xref ref-type="bibr" rid="scirp.127423-ref1">1</xref>] - [<xref ref-type="bibr" rid="scirp.127423-ref23">23</xref>] . To the best of our knowledge, this is the first study demonstrating the use of standoff Raman spectroscopy to analyze pharmaceutical pain relievers.</p></sec><sec id="s3"><title>3. Methods and Materials</title><p>The analytical grade standard acetaminophen with a molecular weight of 151.2 and the molecular and linear formula of C<sub>8</sub>H<sub>9</sub>NO<sub>2</sub> [<xref ref-type="bibr" rid="scirp.127423-ref24">24</xref>] , and CH<sub>3</sub>CONHC<sub>6</sub>H<sub>4</sub>OH [<xref ref-type="bibr" rid="scirp.127423-ref25">25</xref>] , respectively, was purchased from Sigma-Aldrich, U.S.A. in powder form. The commercial pain relievers containing acetaminophen (liquid acetaminophen 500 mg per 15 mL) and aspirin 325 mg tablets were obtained from local drug stores. As indicated on the product’s label, the inactive ingredients of the liquid acetaminophen 500 mg per 15 mL pain reliever include citric acid, high fructose corn syrup, polyethylene glycol, propylene glycol, purified water, saccharin sodium, sodium benzoate, sorbitol and synthetic dyes D &amp; C red # 33 and FD &amp; C red #40. The 325 mg aspirin tablet is a nonsteroidal anti-inflammatory drug (NSAID) containing inactive ingredients such as corn starch, hypromellose, polyethylene glycol, and propylene glycol [<xref ref-type="bibr" rid="scirp.127423-ref26">26</xref>] .</p><p>The vibrational spectra of the standard and specimens were acquired using conventional and standoff Raman spectroscopy systems. The traditional Raman measurements were collected at an optimum distance of 7 mm and at close contact with the container/bottle, and the remote Raman measurements were captured at distances of 1 - 5 meters. The Raman system used is a portable 785 nm excitation diode laser EZRaman Analyzer (Enwave Optronics EZRaman) consisting of a continuous wave excitation wavelength of 785 nm diode laser with a maximum output power of 400 mW, integrated with a charge-coupled device (CCD) detector coupled to a small spectrometer, which has a spectral resolution of 6 cm<sup>–1</sup>, and a spectral range of 250 - 2500 cm<sup>–1</sup>. The laser power for all the measurements was set to about 100 mW at the specimens. For the standoff measurements, a 2-inch refractive telescope focuses the laser light on the sample target and collects the scattered Raman light from the sample back to the spectrometer.</p></sec><sec id="s4"><title>4. Results and Discussions</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref> presents the baseline corrected Raman spectrum of acetaminophen powder captured at 7 mm and at a standoff distance of 1 meter collected with 30 seconds integration time. The result shows strong bands at 383, 643, 791, 850, 1163, 1231, 1273, 1319, 1367, 1558, 1607, and 1644 cm<sup>−1</sup>, with the bands located at 850, 1231, 1319, 1607, and 1644 cm<sup>−1</sup> being very prominent. Other weaker Raman bands are located at 320, 457, 496, 596, 619, 703, 962, 1010, 1099, 1252, 1441, 1503, and 1511. The conventional Raman measurements acquired at a distance of 7 mm between the laser tip and the specimens and the spectra captured from the standard acetaminophen powder placed at standoff distances of 1 - 5 meters from the probe identified all the characteristics Raman bands (<xref ref-type="fig" rid="fig1">Figure 1</xref> and <xref ref-type="fig" rid="fig2">Figure 2</xref>). One significant difference between the measurements is the variation in peak intensities with the distance between the laser and the specimens.</p><p>The correlation between the Raman band intensities with the distances is plotted in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The strong characteristics Raman bands located at 791, 858, and 1231 cm<sup>−1</sup> are attributed to the CNC ring stretching, ring breaching and C-C ring stretching, respectively [<xref ref-type="bibr" rid="scirp.127423-ref17">17</xref>] . The bands at 1319, 1558, 1607, and 1644 cm<sup>−1</sup>, which are slightly shifted from the bands reported by Chetan et al., [<xref ref-type="bibr" rid="scirp.127423-ref17">17</xref>] are assigned to amide III, amide II N-H in-plane deformation, skeletal aryl C-C ring stretching, and amide I modes respectively [<xref ref-type="bibr" rid="scirp.127423-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref20">20</xref>] . The weak bands at 841, 1441, and 1511 cm<sup>−1</sup>, are assigned to out-of-plane C-H bending skeletal aryl C-C stretch and aryl C-H symmetric bends, respectively [<xref ref-type="bibr" rid="scirp.127423-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.127423-ref20">20</xref>] .</p><p>Similar to the acetaminophen standard, Raman spectra of 325 mg aspirin tablets were captured at 15 seconds of integration time (<xref ref-type="fig" rid="fig4">Figure 4</xref>). The measurements show strong Raman bands at 417, 542, 632, 696, 743, 777, 1038, 1147, 1252, 1288, and 1602 cm<sup>−1</sup>. There are also several weak, but discernable bands at 283, 313, 370, 506, 656, 799, 849, 876, 911, 964, 1007, 1217, 1363, 1424, 1478, 1572, 1622, 1720, and 1747 cm<sup>−1</sup>. Due to the variation in Raman band intensities among the traditional Raman and the remote measurements, the spectra of the aspirin tablets captured at remote distances of 1, 2, and 3 meters collected at 60 seconds integration time are plotted separately (<xref ref-type="fig" rid="fig5">Figure 5</xref>). <xref ref-type="fig" rid="fig6">Figure 6</xref> shows the Raman spectra of 500 mg per 15 mL acetaminophen liquid acquired at 120 seconds of integration time, with the probe touching the bottle (without removing the sample from the container). <xref ref-type="fig" rid="fig7">Figure 7</xref> shows the spectra of the same sample placed at standoff distances of 1, and 2 meters from the laser source, collected at 120 seconds of integration time. The results show that Raman bands identifying acetaminophen in the liquid are slightly shifted compared to the bands observed in the reference but are present. The peaks observed in the standard specimen shifted in the liquid specimen include bands at 326, 702, 797, 854, and 1613 cm<sup>−1</sup>. The other Raman bands represent the presence of the inactive ingredients of the liquid acetaminophen 500 mg per 15 mL pain reliever.</p><p>The standoff Raman results presented in <xref ref-type="fig" rid="fig2">Figure 2</xref> and <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig7">Figure 7</xref> suggest the viability of the technique for remote screening and identification of pharmaceutical pain relievers in powder, tablets, and liquid form. To analyze the variation in band intensities of the traditional and the remote measurements, the intensity ratios of the two prominent peaks of acetaminophen reference (1607 and 1319 cm<sup>−1</sup>) normalized with 1319 cm<sup>−1</sup> with each data point shown in the chart averaged from 5 measurements. As shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, the ratio of the Raman band intensity captured at 7 mm (conventional measurement) is about 0.9 followed by the standoff distances ranging from 1 m to 5 meters. The data points are well-fitted to the logarithmic dependence trend line with an R<sup>2</sup> value of 0.93. The equation of the curve is y = −0.018ln(x) + 0.8161. This equation correlates the intensity ratio of the acetaminophen reference sample with the standoff distances between the probe and the sample.</p></sec><sec id="s5"><title>5. Conclusion</title><p>Conventional and standoff Raman measurements of pain-relievers in powder, solid and liquid forms have been accomplished. The traditional Raman measurements were collected at an optimum distance of 7 mm between the specimen and the laser source, and the remote spectra were captured at 1 - 5 meters distances between the laser source and the samples. All the measurements acquired revealed the characteristic spectral signatures of the specimens studied, with varying peak intensities, demonstrating the feasibility of the conventional and standoff Raman spectroscopy for non-invasive and non-destructive detection and identification of pain relievers without removing the specimens from the containers. The results of the pharmaceutical pain relievers in powder form, liquid, and tablets indicated the reliability of the technique for routine checking, detection, and identification of pharmaceutical products in the laboratory and field setting. The method is efficient, non-destructive, and reproducible results that can be acquired and analyzed in a short period of time.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This work is supported in part by the NASA-MUREP program through the Federal Award No. NASA-80NSSC21M0307. A.K. would like to acknowledge the support provided by Dr. Anup Sharma, Professor of Physics at Alabama A&amp;M University.</p></sec><sec id="s7"><title>Author Contributions</title><p>D. R. is an undergraduate student at Alabama State University who participated in the summer research internship program at Alabama A &amp; M University supported by the NASA-MUREP program. A. K. and D. R. conducted the measurements. A. K. originated the idea and wrote the manuscript.</p></sec><sec id="s8"><title>Disclaimer</title><p>The views and conclusions in this document are those of the authors and should not be interpreted as necessarily representing the official policies, either expressed or implied by NASA.</p></sec><sec id="s9"><title>Conflicts of Interest</title><p>The authors declare no conflict of interest.</p></sec><sec id="s10"><title>Cite this paper</title><p>Kassu, A. and Robinson, D. (2023) Vibrational Spectroscopy of Pain Relievers: Traditional and Remote Raman Techniques. Journal of Analytical Sciences, Methods and Instrumentation, 13, 27-37. https://doi.org/10.4236/jasmi.2023.133003</p></sec></body><back><ref-list><title>References</title><ref id="scirp.127423-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Sharma, S.K., Lucey, P.G., Ghosh, M., Hubble, H.W. and Horton, K.A. (2003) Standoff Raman Spectroscopic Detection of Minerals on Planetary Surfaces. Spectrochimica Acta Part A, 59, 2391-2407. https://doi.org/10.1016/S1386-1425(03)00080-5</mixed-citation></ref><ref id="scirp.127423-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Hirschfeld, T., Schildkraut, E.R., Tannenbaum, H. and Tanenbaum, D. (1973) Remote Spectroscopic Analysis of ppm-Level Air Pollutants by Raman Spectroscopy. Applied Physics Letters, 22, 38-40. https://doi.org/10.1063/1.1654465</mixed-citation></ref><ref id="scirp.127423-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Carter, J.C., Angel, S.M., Snyder, M.L., Scaffidi, J., Whipple, R.E. and Reynolds, J.G. (2005) Standoff Detection of High Explosive Materials at 50 Meters in Ambient Light Conditions Using a Small Raman Instrument. Applied Spectroscopy, 59, 769-775. https://doi.org/10.1366/0003702054280612</mixed-citation></ref><ref id="scirp.127423-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Wallin, S., Pettersson, A., &amp;#214;stmarkand, H. and Hobro, A. (2009) Laser-Based Standoff Detection of Explosives: A Critical Review. Analytical and Bioanalytical Chemistry, 395, 259-274. https://doi.org/10.1007/s00216-009-2844-3</mixed-citation></ref><ref id="scirp.127423-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Zou, M.Q., Zhang, X.F., Qi, X., Ma, H.L., Dong, Y., Liu, C.W., Guo, X. and Wang, H. (2009) Rapid Authentication of Olive Oil Adulteration by Raman Spectrometry. Journal of Agricultural Food Chemistry, 57, 6001-6006. https://doi.org/10.1021/jf900217s</mixed-citation></ref><ref id="scirp.127423-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Farley, C., Kassu, A., Bose, N., Jackson-Davis, A., Boateng, J., Ruffin, P. and Sharma, A. (2017) Short Distance Standoff Raman Detection of Extra Virgin Olive Oil Adulterated with Canola Oil and Grapeseed Oil. Applied Spectroscopy, 71, 1340-1347. https://doi.org/10.1177/0003702816681796</mixed-citation></ref><ref id="scirp.127423-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Sadate, S., Farley, C., Kassu, A. and Sharma, A. (2015) Standoff Raman Spectroscopy of Explosive Nitrates Using 785nm Laser. American Journal of Remote Sensing, 3, 1-5. https://doi.org/10.11648/j.ajrs.20150301.11</mixed-citation></ref><ref id="scirp.127423-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Vankeirsbilck, T., Vercauteren, A., Baeyens, W. and Van der Weken, G. (2002) Applications of Raman Spectroscopy in Pharmaceutical Analysis. TrAC Trends in Analytical Chemistry, 21, 869-877. https://doi.org/10.1016/S0165-9936(02)01208-6</mixed-citation></ref><ref id="scirp.127423-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">McCreery, R.L., Horn, A.J., Spencer, J. and Jefferson, E. (1998) Noninvasive Identification of Materials Inside USP Vials with Raman Spectroscopy and a Raman Spectral Library. Journal of Pharmaceutical Sciences, 87, 1-8. https://doi.org/10.1021/js970330q</mixed-citation></ref><ref id="scirp.127423-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Mansouri, M.A., Sacré, P.Y., Co&amp;#239;c, L., Bleye, C.D., Dumont, E., Bouklouze, A., Hubert, P., Marini, R.D. and Ziemons, E. (2020) Quantitation of Active Pharmaceutical Ingredient through the Packaging Using Raman Handheld Spectrophotometers: A Comparison Study. Talanta, 207, Article ID: 120306. https://doi.org/10.1016/j.talanta.2019.120306</mixed-citation></ref><ref id="scirp.127423-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Moynihan, H.A. and O’Hare, I.P. (2002) Spectroscopic Characterization of the Monoclinic and Orthorhombic Forms of Paracetamol. International Journal of Pharmaceutics, 247, 179-185. https://doi.org/10.1016/S0378-5173(02)00420-9</mixed-citation></ref><ref id="scirp.127423-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Roggo, Y., Degardin, K. and Margot, P. (2010) Identification of Pharmaceutical Tablets by Raman Spectroscopy and Chemometrics. Talanta, 81, 988-995. https://doi.org/10.1016/j.talanta.2010.01.046</mixed-citation></ref><ref id="scirp.127423-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Uchida, H., Eguchi, K. and Otsuka, M. (2012) Effect of Laser Irradiation on the Stability of a Photo-sensitive Active Pharmaceutical Ingredient by Raman Microscopy. Journal of Pharmaceutical and Biomedical Analysis, 70, 259-264. https://doi.org/10.1016/j.jpba.2012.07.007</mixed-citation></ref><ref id="scirp.127423-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Kakio, T., Yoshida, N., Macha, S., Moriguchi, K., Hiroshima, T., Ikeda, Y., Tsuboi, H. and Kimura, K. (2017) Classification and Visualization of Physical and Chemical Properties of Falsified Medicines with Handheld Raman Spectroscopy and X-Ray Computed Tomography. The American Journal of Tropical Medicine and Hygiene, 97, 684-689. https://doi.org/10.4269/ajtmh.16-0971</mixed-citation></ref><ref id="scirp.127423-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Khandasammy, S.R., Fikiet, M.A., Mistek, E., Ahmed, Y., Halámková, L., Bueno, J. and Lednev, I.K. (2018) Bloodstains, Paintings, and Drugs: Raman Spectroscopy Applications in Forensic Science. Forensic Chemistry, 8, 111-133. https://doi.org/10.1016/j.forc.2018.02.002</mixed-citation></ref><ref id="scirp.127423-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Kim, M., Chung, H., Woo, Y. and Kemper, M.S. (2007) A New Non-Invasive, Quantitative Raman Technique for the Determination of an Active Ingredient in Pharmaceutical Liquids by Direct Measurement through a Plastic Bottle. Analytica Chimica Acta, 587, 200-207. https://doi.org/10.1016/j.aca.2007.01.062</mixed-citation></ref><ref id="scirp.127423-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Shende, C., Smith, W., Brouillette, C. and Farquharson, S. (2014) Drug Stability Analysis by Raman Spectroscopy. Pharmaceutics, 6, 651-662. https://doi.org/10.3390/pharmaceutics6040651</mixed-citation></ref><ref id="scirp.127423-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Crowell, E.L., Dreger, Z.A. and Gupta, Y.M. (2015) High-Pressure Polymorphism of Acetylsalicylic Acid (Aspirin): Raman Spectroscopy. Journal of Molecular Structure, 1082, 29-37. https://doi.org/10.1016/j.molstruc.2014.10.079</mixed-citation></ref><ref id="scirp.127423-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Amin, M.O., Al-Hetlani, E. and Lednev, I.K. (2022) Detection and Identification of Drug Traces in Latent Fingermarks Using Raman Spectroscopy. Scientific Reports, 12, Article No. 3136. https://doi.org/10.1038/s41598-022-07168-6</mixed-citation></ref><ref id="scirp.127423-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Zhao, X., Wang, N., Zhu, M., Qiu, X., Sun, S., Liu, Y., Zhao, T., Yao, J. and Shan, G. (2022) Application of Transmission Raman Spectroscopy in Combination with Partial Least-Squares (PLS) for the Fast Quantification of Paracetamol. Molecules, 27, Article No. 1707. https://doi.org/10.3390/molecules27051707</mixed-citation></ref><ref id="scirp.127423-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Castro-Suarez, J.R., Vásquez-Osorio, M., Hernandez-Rivera, S.P. and Pájaro-Payares, A.A. (2019) Vibrational Analysis of Acetaminophen from Commercial Tablets. IOP Conference Series: Materials Science and Engineering, 519, Article ID: 012006. https://doi.org/10.1088/1757-899X/519/1/012006</mixed-citation></ref><ref id="scirp.127423-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Tondepu, C., Toth, R., Navin, C.V., Lawson, L.S. and Rodriguez, J.D. (2017) Screening of Unapproved Drugs Using Portable Raman Spectroscopy. Analytica Chimica Acta, 973, 75-81. https://doi.org/10.1016/j.aca.2017.04.016</mixed-citation></ref><ref id="scirp.127423-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, Z.Z. and Jiang, C.J. (2021) Effect of Polyethylene Glycol on Crystallization Behavior of Acetaminophen. Open Access Library Journal, 8, e7932. https://doi.org/10.4236/oalib.1107932</mixed-citation></ref><ref id="scirp.127423-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Spectral Database for Organic Compounds (SDBS); Raman Spectrum, SDBS No.: 3290, CAS Registry No.: 103-90-2. https://sdbs.db.aist.go.jp/sdbs/cgi-bin/landingpage?sdbsno=3290</mixed-citation></ref><ref id="scirp.127423-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Sigma-Aldrich. https://www.sigmaaldrich.com/US/en/search/acetaminophen?focus=products&amp;page=1&amp;perpage=30&amp;sort=relevance&amp;term=acetaminophen&amp;type=product</mixed-citation></ref><ref id="scirp.127423-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">National Institute of Medicine (NIH), National Library of Medicine. https://dailymed.nlm.nih.gov/dailymed/fda/fdaDrugXsl.cfm?setid=35005045-57b2-4ffe-ab70-22d570c1b161&amp;type=display</mixed-citation></ref></ref-list></back></article>