<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJAppS</journal-id><journal-title-group><journal-title>Open Journal of Applied Sciences</journal-title></journal-title-group><issn pub-type="epub">2165-3917</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojapps.2023.136072</article-id><article-id pub-id-type="publisher-id">OJAppS-125850</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Modified Concrete Using Polyethylene Terephthalate Plastic Waste as a Partial Replacement for Coarse Aggregate
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Dodo</surname><given-names>Kayentao</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Moussa</surname><given-names>Tamboura</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Antoine</surname><given-names>Padou Diarra</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mah</surname><given-names>Fatoumata Traore</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Adama</surname><given-names>Coulibaly</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Aboubacar</surname><given-names>Sidiki Toure</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mohamed</surname><given-names>L. O. Diawara</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kélétigui</surname><given-names>Daou</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Faculty of Sciences and Techniques (FST), University of Sciences, Techniques, and Technologies of Bamako, Bamako, Mali</addr-line></aff><aff id="aff3"><addr-line>National School of Engineering Abderhamane Baba TOURE (ENI-ABT), Bamako, Mali</addr-line></aff><aff id="aff2"><addr-line>National Research and Experimentation Center for Buildings and Public Works (CNREX-BTP), Bamako, Mali</addr-line></aff><pub-date pub-type="epub"><day>08</day><month>06</month><year>2023</year></pub-date><volume>13</volume><issue>06</issue><fpage>896</fpage><lpage>909</lpage><history><date date-type="received"><day>1,</day>	<month>June</month>	<year>2023</year></date><date date-type="rev-recd"><day>25,</day>	<month>June</month>	<year>2023</year>	</date><date date-type="accepted"><day>28,</day>	<month>June</month>	<year>2023</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The present work evaluated the properties of modified concrete using polyethylene terephthalate (PET) bottle waste as a partial replacement for coarse aggregate. Modified concrete samples were designed using a water/cement 
  (W/C) ratio of 0.50 and varying percentages of PET replacement (3%, 7%, 10%
  , and 15% by volume). Dreux Gorisse’s formulation approach was used to make the final products, and the mechanical properties of the samples were determined using Controlab presses. This modified concrete with PET chips has shown that with a 10% replacement of PET chips, the fresh density decreases by 3.56%, and the hardened state density decreases by 2.01%. The wa
  ter absorption and thermal conductivity of the formulated concretes decreased
  . However, the results showed that the slump of these fresh concretes increased as the percentage of plastic aggregate replacement increased. Based on the results, incorporating PET aggregates into concrete contributes to good wor
  kability, and lightweight concrete structures, and provides some thermal comfort 
  in concrete structures.
 
</p></abstract><kwd-group><kwd>PET Waste</kwd><kwd> Concrete</kwd><kwd> Dreux Gorisse Approach</kwd><kwd> Thermal Conductivity</kwd><kwd> Mechanical Properties of Modified Concrete</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Nowadays, concrete is part of our daily life. It is one of the most widely used construction materials in the world due to the simplicity of its manufacture and installation, its durability and economy, and the mechanical performance it provides. These properties have legitimized its use in various construction infrastructures (building, bridge, pipes, blocks, beams, floors, partitions, stairs, etc.) [<xref ref-type="bibr" rid="scirp.125850-ref1">1</xref>] . For the improvement of its properties, various materials are incorporated into concrete, including plastic materials.</p><p>However, the consumption of various forms of plastic material is growing exponentially and most of these plastics are abandoned and require large landfill areas for storage. More importantly, the low biodegradability of plastics poses a serious threat to environmental protection [<xref ref-type="bibr" rid="scirp.125850-ref2">2</xref>] . To counteract this threat, plastic waste is generally incorporated into concrete or mortar as aggregates [<xref ref-type="bibr" rid="scirp.125850-ref3">3</xref>] .</p><p>Aggregates generally represent 65% to 80% of the volume of concrete and play an important role in the properties of concrete, such as workability, strength, dimensional stability, and durability [<xref ref-type="bibr" rid="scirp.125850-ref3">3</xref>] .</p><p>The wide range of applications of concrete and the amount of space occupied by aggregates in concrete justify their use in the context of plastic waste recycling, which has become a major concern of environmental policies around the world [<xref ref-type="bibr" rid="scirp.125850-ref4">4</xref>] .</p><p>In general, plastic waste is used as aggregate in the formulation of concrete due to some of its properties, such as low apparent density, low density and very low water absorption. These different properties have been evaluated in the majority of reported studies [<xref ref-type="bibr" rid="scirp.125850-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref9">9</xref>] . Some authors’ works affirm that the standard procedures used to evaluate properties such as bulk density, density, and water absorption of natural coarse and fine aggregates can be used for plastic aggregates with slight modifications [<xref ref-type="bibr" rid="scirp.125850-ref10">10</xref>] . On the other hand, properties such as hardness, tensile and compressive strength, modulus of elasticity, decomposition temperature, melting and initial degradation temperatures, hot flow index (HFI), specific heat capacity (SHC), and thermal conductivity (TC) of plastic aggregate are also studied [<xref ref-type="bibr" rid="scirp.125850-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref11">11</xref>] .</p><p>Several studies focus on the water-to-binder ratios and the amount of polymer in the mixture. In the context of studies on the miscibility of plastic aggregates in concrete, Ak&#231;a&#246;zoglu et al. reviewed the use of crushed PET bottle waste as aggregates in lightweight concrete. Samples made of only PET aggregates and those consisting of a mixture of PET and sand with a water-to-cement ratio (W/C) of 0.45 were compared to the reference concrete. The tests showed that the samples can be classified in the category of structural lightweight concrete in terms of unit weight and strength properties [<xref ref-type="bibr" rid="scirp.125850-ref12">12</xref>] . Albano et al.,’s work on the influence of the content, particle size, and thermal degradation of PET bottle waste on the behavior of concrete at different water/cement ratios (0.50 and 0.60) indicated that in concrete filled with PET, as the volumetric proportion and particle size of PET increase, a decrease in compressive strength, tensile strength, modulus of elasticity, and ultrasonic pulse velocity is observed. However, water absorption increases. On the other hand, when concrete-PET is exposed to a heat source, the flexural strength of the concrete-PET decreases significantly as the temperature, water/cement ratio, content, and size of PET particles increase [<xref ref-type="bibr" rid="scirp.125850-ref11">11</xref>] .</p><p>The works cited prove that the optimal properties of modified concrete mixes with plastic aggregates would depend on the water/binder ratio, but do not specify the exact ratio or the amount of polymers required for these corresponding optimal properties, for a common use of these concretes. Therefore, the general objective of this study is to evaluate the effect of incorporating PET chips with dimensions of 10 - 15 mm wide on the properties of modified concrete mixes with PET aggregates using a water/cement ratio commonly used in the formulation of concrete.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Materials</title><p>A CEM II B-M 32.5 R Portland cement, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>, was used in this study. The chemical and physical properties are presented in <xref ref-type="table" rid="table1">Table 1</xref>. Crushed gravel with a size of 5/15 from Mountougoula was used as coarse aggregate. The Niger River sand from Kalaban-Coro was used as a natural fine aggregate. PET plastic waste, used as a partial substitute for the coarse aggregate, was collected from the Badalabougou landfill. The waste was sorted and washed. Then, it was perforated and cut into chips of the dimensions indicated in <xref ref-type="table" rid="table2">Table 2</xref>.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows the chips of the PET aggregates.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Physical and chemical characteristics of the Portland cement used</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Elements</th><th align="center" valign="middle"  colspan="3"  >(%)</th></tr></thead><tr><td align="center" valign="middle" >Chemical analysis</td><td align="center" valign="middle"  colspan="3"  ></td></tr><tr><td align="center" valign="middle" >CaO</td><td align="center" valign="middle"  colspan="3"  >44</td></tr><tr><td align="center" valign="middle" >SiO<sub>2</sub></td><td align="center" valign="middle"  colspan="3"  >26</td></tr><tr><td align="center" valign="middle" >Al<sub>2</sub>O<sub>3</sub></td><td align="center" valign="middle"  colspan="3"  >5.76</td></tr><tr><td align="center" valign="middle" >Fe<sub>2</sub>O<sub>3</sub></td><td align="center" valign="middle"  colspan="3"  >4.88</td></tr><tr><td align="center" valign="middle" >MgO</td><td align="center" valign="middle"  colspan="3"  >1.63</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>O</td><td align="center" valign="middle"  colspan="3"  >3.27</td></tr><tr><td align="center" valign="middle" >SO<sub>3</sub></td><td align="center" valign="middle"  colspan="3"  >2.3</td></tr><tr><td align="center" valign="middle" >Cl</td><td align="center" valign="middle"  colspan="3"  >0.03</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >Stability Volume</td><td align="center" valign="middle"  colspan="2"  >Normal consistency (mL)</td><td align="center" valign="middle" >165</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Initial curing (mn)</td><td align="center" valign="middle" >249</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Final curing (mn)</td><td align="center" valign="middle" >449</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >Compressive strength (MPa)</td><td align="center" valign="middle" >2 days</td><td align="center" valign="middle"  colspan="2"  >16.33</td></tr><tr><td align="center" valign="middle" >7 days</td><td align="center" valign="middle"  colspan="2"  >29.235</td></tr><tr><td align="center" valign="middle" >28 days</td><td align="center" valign="middle"  colspan="2"  >37.336</td></tr><tr><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Dimensions of PET chips</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Type of plastic</th><th align="center" valign="middle" >Apparent volumetric mass (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Thickness (mm)</th><th align="center" valign="middle" >Width (mm)</th><th align="center" valign="middle" >Hole diameter (mm)</th><th align="center" valign="middle" >Spacing between holes (mm)</th></tr></thead><tr><td align="center" valign="middle" >PET</td><td align="center" valign="middle" >220</td><td align="center" valign="middle" >0.25</td><td align="center" valign="middle" >10 - 15</td><td align="center" valign="middle" >1 &#224; 2</td><td align="center" valign="middle" >5 - 8</td></tr></tbody></table></table-wrap></sec><sec id="s2_2"><title>2.2. Methods</title><p>The materials used have been characterized and evaluated according to the European standard testing methods indicated in <xref ref-type="table" rid="table3">Table 3</xref>. The determination of the mechanical properties of the cement mortar was carried out on 4 &#215; 4 &#215; 16 cm prismatic specimens. The experimental results of the different properties of the natural aggregates are illustrated in <xref ref-type="fig" rid="fig3">Figure 3</xref> and <xref ref-type="table" rid="table4">Table 4</xref>.</p><p>The concrete samples were formulated using the Dreux Gorisse formulation method, which involves using the natural aggregate mixing curve to obtain the aggregate quantities in volume. The cement content and water quantity were obtained through the Bolomey formula and the cement quantity estimation chart. The proportions of the preliminary concrete samples based on the variation of the water-to-cement ratio (W/C) are shown in <xref ref-type="table" rid="table5">Table 5</xref>. The modified concrete samples with PET chips were formulated using 3%, 7%, 10% and 15% PET replacements in molds with dimensions of 16 &#215; 32 cm. The proportions of the PET aggregate modified samples are illustrated in <xref ref-type="table" rid="table6">Table 6</xref>.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Methods for characterizing the materials used</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >properties targeted</th><th align="center" valign="middle" >Method used</th></tr></thead><tr><td align="center" valign="middle" >Particle size distribution</td><td align="center" valign="middle" >NF EN 933-1</td></tr><tr><td align="center" valign="middle" >Absolute density</td><td align="center" valign="middle"  rowspan="2"  >NF P 18-554</td></tr><tr><td align="center" valign="middle" >Bulk density</td></tr><tr><td align="center" valign="middle" >Cleanness</td><td align="center" valign="middle" >NF EN 933-8</td></tr><tr><td align="center" valign="middle" >Los Angeles coefficient</td><td align="center" valign="middle" >NF EN 1097-2</td></tr><tr><td align="center" valign="middle" >Micro-Deval coefficient</td><td align="center" valign="middle" >NF EN 1097-1</td></tr><tr><td align="center" valign="middle" >Compressive and flexural strength</td><td align="center" valign="middle" >NF EN 196-1</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Properties of natural aggregates</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Designation</th><th align="center" valign="middle" >Los Angeles (LA)</th><th align="center" valign="middle" >Micro deval (MD)</th><th align="center" valign="middle"  colspan="2"  >Sand equivalent</th></tr></thead><tr><td align="center" valign="middle" >crushed gravel 5/15</td><td align="center" valign="middle" >15%</td><td align="center" valign="middle" >10%</td><td align="center" valign="middle"  colspan="2"  >-</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >rolled sand</td><td align="center" valign="middle"  rowspan="2"  >-</td><td align="center" valign="middle"  rowspan="2"  >-</td><td align="center" valign="middle" >On sight</td><td align="center" valign="middle" >plunger</td></tr><tr><td align="center" valign="middle" >97</td><td align="center" valign="middle" >95</td></tr></tbody></table></table-wrap><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Proportions of constituents for concrete samples as a function of W/C ratio</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Sample (SA)</th><th align="center" valign="middle" >Ratio W/C</th><th align="center" valign="middle" >Water (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Cement (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Sand (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >crushed gravel (kg/m<sup>3</sup>)</th></tr></thead><tr><td align="center" valign="middle" >SA-1</td><td align="center" valign="middle" >0.30</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >580</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr><tr><td align="center" valign="middle" >SA-2</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >497.14</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr><tr><td align="center" valign="middle" >SA-3</td><td align="center" valign="middle" >0.40</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >435</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr><tr><td align="center" valign="middle" >SA-4</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >386.66</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr><tr><td align="center" valign="middle" >SA-5*</td><td align="center" valign="middle" >0.50</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr><tr><td align="center" valign="middle" >SA-6</td><td align="center" valign="middle" >0.60</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >290</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td></tr></tbody></table></table-wrap><p>SA-5*: designates the w/c ratio for the formulation of modified concretes.</p><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> Proportions of constituents of concretes modified with PET aggregate</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Sample</th><th align="center" valign="middle" >Cement (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Water (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Sand (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >Coarse aggregates (kg/m<sup>3</sup>)</th><th align="center" valign="middle" >PET Plastic (kg/m<sup>3</sup>)</th></tr></thead><tr><td align="center" valign="middle" >Reference</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1041.3</td><td align="center" valign="middle" >-</td></tr><tr><td align="center" valign="middle" >3%PET</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >1010.06</td><td align="center" valign="middle" >4.68</td></tr><tr><td align="center" valign="middle" >7%PET</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >968.409</td><td align="center" valign="middle" >10.92</td></tr><tr><td align="center" valign="middle" >10% PET</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >937.17</td><td align="center" valign="middle" >15.6</td></tr><tr><td align="center" valign="middle" >15%PET</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >732.6</td><td align="center" valign="middle" >885.105</td><td align="center" valign="middle" >23.4</td></tr></tbody></table></table-wrap><p>The modified concrete mixes were prepared and poured using standard methods. The slump and fresh density were determined immediately after mix preparation. They were then poured into 16 &#215; 32 cm molds and their air content was reduced using a vibrating table. The samples were kept in these molds at room temperature for approximately 24 hours to harden before being demolded and transferred to a humid chamber for a curing period of 28 days. Then they were subjected to compression, tension, and water absorption tests.</p><p>The methods used to determine the properties of the concrete in the fresh and hardened state are illustrated in <xref ref-type="table" rid="table7">Table 7</xref>. The compressive strength of the hardened concrete specimens was determined after 7, 14, 21, and 28 days of curing using a Controlab C0070HP automatic Servotronique compression press with a maximum load of 3000 kN. The splitting tensile strength was determined using a Controlab traction press after 28 days of curing. Water absorption was determined as described in the NBN EN 13369:2014 standard [<xref ref-type="bibr" rid="scirp.125850-ref13">13</xref>] , using a Memmert UN/UF universal oven (temperature up to 300˚C) to dry the samples.</p><p>Thermal conductivity was determined through the EI700 cell of the box method according to ISO 8990 (Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated hot box method, 1996). For the determination of this parameter, a square mold with dimensions of 27 cm on each side and a thickness of 3 cm (2187 cm<sup>3</sup>) was used to make the samples. The proportions used for the samples are indicated in <xref ref-type="table" rid="table8">Table 8</xref>. After preparation, the samples were dried for a period of 28 days to prevent shrinkage phenomena.</p><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> Experimental methods used for the characterization of concrete</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Properties</th><th align="center" valign="middle" >Method</th></tr></thead><tr><td align="center" valign="middle" >Slump test</td><td align="center" valign="middle" >NF EN 12350-2</td></tr><tr><td align="center" valign="middle" >Fresh density</td><td align="center" valign="middle" >NF EN 12350-6</td></tr><tr><td align="center" valign="middle" >Compressive strength</td><td align="center" valign="middle" >NF EN 12390-3</td></tr><tr><td align="center" valign="middle" >Tensile strength</td><td align="center" valign="middle" >NF EN 12390-6</td></tr><tr><td align="center" valign="middle" >Water absorption</td><td align="center" valign="middle" >NBN EN 13369:2004</td></tr><tr><td align="center" valign="middle" >Thermal conductivity</td><td align="center" valign="middle" >NF EN ISO 8990</td></tr></tbody></table></table-wrap><table-wrap id="table8" ><label><xref ref-type="table" rid="table8">Table 8</xref></label><caption><title> Proportions of constituents for samples formulated with PET</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Sample</th><th align="center" valign="middle" >Cement (g)</th><th align="center" valign="middle" >Water (mL)</th><th align="center" valign="middle" >Fin aggregates (g)</th><th align="center" valign="middle" >Coarse aggregates (g)</th><th align="center" valign="middle" >PET (g)</th></tr></thead><tr><td align="center" valign="middle" >Reference</td><td align="center" valign="middle" >760</td><td align="center" valign="middle" >400</td><td align="center" valign="middle" >1600</td><td align="center" valign="middle" >2300</td><td align="center" valign="middle" >-</td></tr><tr><td align="center" valign="middle" >7% PET</td><td align="center" valign="middle" >760</td><td align="center" valign="middle" >400</td><td align="center" valign="middle" >1600</td><td align="center" valign="middle" >2120</td><td align="center" valign="middle" >23.9</td></tr><tr><td align="center" valign="middle" >10%PET</td><td align="center" valign="middle" >760</td><td align="center" valign="middle" >400</td><td align="center" valign="middle" >1600</td><td align="center" valign="middle" >2050</td><td align="center" valign="middle" >34</td></tr></tbody></table></table-wrap><p><xref ref-type="fig" rid="fig4">Figure 4</xref> shows the formulated samples for the EI700 cell.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> illustrates the EI700 measuring cell used to determine thermal properties.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Fresh Properties</title><p>The ratio water/cement (W/C) of the reference concrete used in this study is 0.50. The properties of the preliminary and modified concretes in the fresh state are presented in <xref ref-type="table" rid="table9">Table 9</xref> and <xref ref-type="table" rid="table1">Table 1</xref>0. These mixtures resulted in a slump of modified concretes ranging from 2 to 3 cm. The results showed that the incorporation of PET chips slightly increases the slump value of concrete as the percentage of replacement increases (<xref ref-type="table" rid="table1">Table 1</xref>0). It was also found that between 10% and 15%, the obtained slump values are almost similar. The density of modified concretes in the fresh state decreases as the percentage of PET chip replacement increases. This trend is self-explanatory since the density of natural aggregates is significantly higher than that of PET aggregate.</p></sec><sec id="s3_2"><title>3.2. Hardened Properties</title><sec id="s3_2_1"><title>3.2.1. Compressive Strength</title><p>The variation of compressive strength of modified concretes as a function of the percentage of PET replacement at 7, 14, 21, and 28 days is illustrated in <xref ref-type="fig" rid="fig6">Figure 6</xref>. The results show that, regardless of the PET aggregate content and curing time, the compressive strength decreases, which is in line with previous studies [<xref ref-type="bibr" rid="scirp.125850-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref16">16</xref>] . A gradual increase in compressive strength up to the 28th day (normal curing duration) was observed. It was noted that the strength increases rapidly up to the 7th day, but beyond that age, between 14 and 21 days, the rate of strength evolution is slightly decreased. In <xref ref-type="fig" rid="fig7">Figure 7</xref>, a cone-type fracture was observed. This fracture corresponds to the ideal fracture according to the NF EN 12390-3 standard [<xref ref-type="bibr" rid="scirp.125850-ref17">17</xref>] , although other types of fractures were obtained.</p><table-wrap id="table9" ><label><xref ref-type="table" rid="table9">Table 9</xref></label><caption><title> Fresh properties of preliminary concretes</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Properties</th><th align="center" valign="middle"  colspan="6"  >Formulation of preliminary concretes</th></tr></thead><tr><td align="center" valign="middle" >W/C</td><td align="center" valign="middle" >0.30</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >0.40</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >0.50</td><td align="center" valign="middle" >0.60</td></tr><tr><td align="center" valign="middle" >Slump test (cm)</td><td align="center" valign="middle" >0.7</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >1.3</td><td align="center" valign="middle" >1.6</td><td align="center" valign="middle" >2.00</td><td align="center" valign="middle" >3.00</td></tr><tr><td align="center" valign="middle" >Fresh density (Kg/m<sup>3</sup>)</td><td align="center" valign="middle" >2530.00</td><td align="center" valign="middle" >2525</td><td align="center" valign="middle" >2513</td><td align="center" valign="middle" >2506</td><td align="center" valign="middle" >2498</td><td align="center" valign="middle" >2493</td></tr></tbody></table></table-wrap><table-wrap id="table10" ><label><xref ref-type="table" rid="table1">Table 1</xref>0</label><caption><title> Fresh properties of PET-modified concretes</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Properties</th><th align="center" valign="middle"  colspan="7"  >PET modified concrete</th></tr></thead><tr><td align="center" valign="middle" >3%</td><td align="center" valign="middle"  colspan="2"  >7%</td><td align="center" valign="middle"  colspan="2"  >10%</td><td align="center" valign="middle"  colspan="2"  >15%</td></tr><tr><td align="center" valign="middle" >W/C</td><td align="center" valign="middle"  colspan="7"  >0.50</td></tr><tr><td align="center" valign="middle" >Slump test (cm)</td><td align="center" valign="middle"  colspan="2"  >2.2</td><td align="center" valign="middle"  colspan="2"  >2.3</td><td align="center" valign="middle"  colspan="2"  >2.40</td><td align="center" valign="middle" >2.45</td></tr><tr><td align="center" valign="middle" >Fresh density (Kg/m<sup>3</sup>)</td><td align="center" valign="middle"  colspan="2"  >2471</td><td align="center" valign="middle"  colspan="2"  >2446</td><td align="center" valign="middle"  colspan="2"  >2409</td><td align="center" valign="middle" >2403</td></tr><tr><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap><p>This decrease in compressive strength is due to the very low adhesion of plastic waste to the cement paste, which has caused the appearance of cavities on the surface of the samples, as shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>. Compared to the reference concrete, mixtures with 3%, 7%, 10%, and 15% PET chips present a decrease in compressive strength of 0.34%, 6.64%, 16.71%, and 25.25%, respectively. Despite this decrease in compressive strength compared to the reference, mixtures with 3%, 7%, 10%, and 15% of PET show an acceptable compressive strength, as the standard strength values for medium strength concretes are between 21 and 30 MPa for a curing age of 28 days according to Porrero et al. [<xref ref-type="bibr" rid="scirp.125850-ref18">18</xref>] . Moreover, according to ASTM C39 standard, for ordinary concrete, the minimum compressive strength value for any project typically starts around 2500 to 3000 Psi, or 17 to 20 MPa.</p><p>A similar behavior was observed by some authors [<xref ref-type="bibr" rid="scirp.125850-ref19">19</xref>] [<xref ref-type="bibr" rid="scirp.125850-ref20">20</xref>] , when incorporating recycled PET waste and rubber particles into concrete.</p><p><xref ref-type="fig" rid="fig8">Figure 8</xref> represents the cavities present in the concrete.</p></sec><sec id="s3_2_2"><title>3.2.2. Tensile Strength</title><p><xref ref-type="fig" rid="fig9">Figure 9</xref> illustrates the variation in tensile strength of modified concretes as a function of the percentage of PET replacement. It was observed that the tensile strength of these different concretes decreases slightly as the percentage of replacement increases. This reduction is due to the same phenomenon that causes the decrease in compressive strength, namely the lack of adhesion between the PET chips and the cement. This trend of reduction is confirmed by the results reported by Saikia et al. [<xref ref-type="bibr" rid="scirp.125850-ref3">3</xref>] , when they used these plastic aggregates as coarse aggregates. From all of the above, the incorporation of lightweight aggregates has a major influence on the mechanical properties of concretes, especially compressive and tensile strength.</p></sec><sec id="s3_2_3"><title>3.2.3. Water Absorption</title><p>The variation in water absorption as a function of the percentage of plastic aggregate replacement, as illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref>0, shows a decrease in water absorption as the percentage of replacement increases. This decrease is due to the influence of plastic aggregates on the porosity of concrete and the low water absorption of the polymers used. It was observed that as the percentage of plastic aggregate replacement increased, the porosity of the formulated concrete also increased. This means that the plastic aggregates did not react properly with the cement paste, meaning that they altered the porosity of the concrete. This property was also observed by Porrero et al. [<xref ref-type="bibr" rid="scirp.125850-ref18">18</xref>] , who suggested that plastic aggregate can influence porosity in two ways: one, by providing suitable porosity, and the other by altering the cement paste. According to the NBN B 15-001:2004 standard, the porosity of ordinary concrete should not exceed 15%, a value that is in agreement with the results presented in <xref ref-type="fig" rid="fig1">Figure 1</xref>1. A similar trend was also observed by Saikia et al. [<xref ref-type="bibr" rid="scirp.125850-ref21">21</xref>] . Based on the water absorption results, the incorporation of plastic aggregates leads to a decrease in water absorption as the replacement percentage increases.</p><table-wrap id="table11" ><label><xref ref-type="table" rid="table1">Table 1</xref>1</label><caption><title> Variation of the thermal conduction of the samples according to the percentage of replacement in PET</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Sample</th><th align="center" valign="middle" >T2 (K)</th><th align="center" valign="middle" >T1 (K)</th><th align="center" valign="middle" >Ti (K)</th><th align="center" valign="middle" >Ta (K)</th><th align="center" valign="middle" >Ptrans (W)</th><th align="center" valign="middle" >S (m<sup>2</sup>)</th><th align="center" valign="middle" >e (m)</th><th align="center" valign="middle" >λ (W/mK)</th></tr></thead><tr><td align="center" valign="middle" >Reference</td><td align="center" valign="middle" >347.1</td><td align="center" valign="middle" >344.89</td><td align="center" valign="middle" >357.9</td><td align="center" valign="middle" >300</td><td align="center" valign="middle" >9.105</td><td align="center" valign="middle" >0.0729</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >1.620</td></tr><tr><td align="center" valign="middle" >7% PET</td><td align="center" valign="middle" >346.7</td><td align="center" valign="middle" >344.3</td><td align="center" valign="middle" >357.6</td><td align="center" valign="middle" >300.5</td><td align="center" valign="middle" >9.145</td><td align="center" valign="middle" >0.0729</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >1.570</td></tr><tr><td align="center" valign="middle" >10%PET</td><td align="center" valign="middle" >346 .1</td><td align="center" valign="middle" >343.72</td><td align="center" valign="middle" >358.1</td><td align="center" valign="middle" >299</td><td align="center" valign="middle" >9.046</td><td align="center" valign="middle" >0.0729</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >1.564</td></tr></tbody></table></table-wrap><p>T1: The temperature on the external face of the sample; T2: The temperature on the internal face of the sample; Ti: The temperature in the middle of the heating plate; Ta: Ambient temperature; Ptrans: The Power transmitted; S: The surface of the sample, e: The thickness of the sample; λ: The thermal conductivity of the sample.</p></sec><sec id="s3_2_4"><title>3.2.4. Thermal Conductivity</title><p><xref ref-type="table" rid="table9">Table 9</xref> represents the results of thermal conductivity. A decrease in thermal conductivity was observed with an increasing percentage of plastic aggregate replacement. This decrease is due to the fact that the PET chips incorporated in the concrete have lower thermal conductivity, 0.3 W/m&#183;K, compared to the cement matrix. The value of thermal conductivity obtained with 0% plastic waste shown in <xref ref-type="table" rid="table1">Table 1</xref>1 is in agreement with the classification proposed by energyPlus [<xref ref-type="bibr" rid="scirp.125850-ref22">22</xref>] . Compared to the thermal conductivity of the reference concrete, the incorporation of plastic aggregates provides some thermal comfort in buildings constructed with these concretes.</p></sec></sec></sec><sec id="s4"><title>4. Conclusions</title><p>Based on the results of the basic trials, the materials used in this study meet the proposed standards and requirements for concrete formulation. The preliminary concrete formulations have shown that:</p><p>A concrete mix is workable when the water-to-cement ratio (W/C) increases, good compressive strength of the concrete depends primarily on the W/C ratio, particularly the cement content, an optimal compressive strength is achieved with a W/C ratio of 0.35, and a concrete mix with a W/C ratio of 0.50 (350 kg/m<sup>3</sup> of cement) is a typical dosage for ordinary structures.</p><p>Based on the trial results, the incorporation of PET aggregate in the concrete has led to the following observations:</p><p>The addition of PET as a partial replacement for crushed gravel contributes to a reduction in the unit weight of the concrete; it enhances the workability of the concrete; it decreases the density of both fresh and hardened concrete, depending on the replacement percentage; it reduces the weight of concrete structures; it leads to a decrease in mechanical properties, such as compressive and uniaxial tensile strength of the concrete; it increases the porosity of the formulated concrete but remains within acceptable limits; it provides a certain level of thermal comfort when incorporated.</p><p>Despite its effect on the mechanical characteristics of the concrete, the results confirmed that PET can be incorporated into the concrete with a replacement rate of up to 15% without major consequences, depending on the specific application of the concrete.</p><p>Based on this study, a W/C ratio of 0.50 is considered a suitable and commonly used ratio for concrete containing plastic aggregates.</p><p>Depending on the percentage of plastic aggregate replacement in the concrete, the modified plastic aggregate concrete can be used in construction. For example, concrete with a 15% replacement of PET, which has a compressive strength of 17.527 MPa at 28 days, can be used for sidewalks, stairs, interior walls, low-height concrete walls, storage tanks, coatings, non-structural slabs, etc.</p><p>However, the adhesion between the concrete matrix and the plastic remains the major problem for the mechanical parameters of the modified concrete.</p></sec><sec id="s5"><title>Acknowledgements</title><p>We would like to express our gratitude to the National Center for Research and Experimentation in Building and Public Works (CNREX-BTP) for generously providing us with materials such as cement and sand, and allowing us to perform the majority of mechanical tests in their dedicated laboratories. Our heartfelt thanks also go to the Normal School of Engineers (ENI-ABT) for providing their laboratory for the determination of thermal properties of the formulated materials in the context of this study.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Kayentao, D., Tamboura, M., Diarra, A.P., Traore, M.F., Coulibaly, A., Toure, A.S., Diawara, M.L.O. and Daou, K. (2023) Modified Concrete Using Polyethylene Terephthalate Plastic Waste as a Partial Replacement for Coarse Aggregate. Open Journal of Applied Sciences, 13, 896-909. https://doi.org/10.4236/ojapps.2023.136072</p></sec></body><back><ref-list><title>References</title><ref id="scirp.125850-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Abdoune, C. and Haddad, O.K. (2020) Use of Plastic Waste in Composite Building Materials. Master’s Thesis, Ahmed Dra&amp;#239;a University of Adrar, Adrar.</mixed-citation></ref><ref id="scirp.125850-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Zasiah, T., Rakibul Islam, R., Esharuhullah, S.M., Reduanul, A. and Mashfiqul, I. (2018) Experimental Investigation on the Properties of Concrete Containing Post-Consumer Plastic Waste as Coarse Aggregate Replacement. Journal of Materials and Engineering Structures, 5, 23-31.</mixed-citation></ref><ref id="scirp.125850-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Saikia, N. and de Jorge, B. (2014) Mechanical Properties and Abrasion Behaviour of Concrete Containing Shredded PET Waste Bottle Aggregate as a Partial Substitution of Natural Aggregate. Construction and Building Materials, 52, 236-244. https://doi.org/10.1016/j.conbuildmat.2013.11.049</mixed-citation></ref><ref id="scirp.125850-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Hanane, B. and Siham A.H. (2019) Monitoring of Solid Waste Sorting and Recovery Operations. Master’s Thesis, Abderrahmane Mira-Béja&amp;#239;a University, Targa ouzemour.</mixed-citation></ref><ref id="scirp.125850-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Marzouk, O., Dheilly, R. and Queneudec, M. (2007) Valorisation of Post-Consumer Plastic Waste in Cementitious Concrete Composites. Waste Management, 27, 310-318. https://doi.org/10.1016/j.wasman.2006.03.012</mixed-citation></ref><ref id="scirp.125850-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Kou, S., Lee, G., Poon, C. and Lai, W. (2009) Properties of Lightweight Aggregate Concrete Prepared with PVC Granules Derived from Scraped PVC Pipes. Waste Management, 29, 621-628. https://doi.org/10.1016/j.wasman.2008.06.014</mixed-citation></ref><ref id="scirp.125850-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Panyakapo, P. and Panyakapo, M. (2008) Reuse of Thermosetting Plastic Waste. Waste Management, 28, 1581-1588. https://doi.org/10.1016/j.wasman.2007.08.006</mixed-citation></ref><ref id="scirp.125850-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Ismail, Z. and Al-Hashmi, E. (2008) Use of Plastic Waste in Concrete Mixture as Aggregate. Waste Management, 28, 2041-2047. https://doi.org/10.1016/j.wasman.2007.08.023</mixed-citation></ref><ref id="scirp.125850-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Frigione, M. (2010) Recycling of PET Bottles as Fine Aggregate in Concrete. Waste Management, 30, 1101-1106. https://doi.org/10.1016/j.wasman.2010.01.030</mixed-citation></ref><ref id="scirp.125850-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Saikia, N. and de Jorge, B. (2012) Use of Plastic Waste as Aggregate in Cement Mortar and Concrete Preparation: A Review. Construction and Building Materials, 34, 385-401. https://doi.org/10.1016/j.conbuildmat.2012.02.066</mixed-citation></ref><ref id="scirp.125850-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Albano, C., Camacho, N., Hernandez, M., Matheus, A. and Gutiérrez, A. (2009) Influence of Content and Particle Size of Waste Pet Bottles on Concrete Behavior at Different w/c Ratios. Waste Management, 29, 2707-2716. https://doi.org/10.1016/j.wasman.2009.05.007</mixed-citation></ref><ref id="scirp.125850-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Ak&amp;#231;aozoglu, S., Atis, C. and Ak&amp;#231;aooglu, K. (2010) An Investigation on the Use of Shredded Pet Waste Bottles as Aggregate in Lightweight Concrete. Waste Management, 30, 285-290. https://doi.org/10.1016/j.wasman.2009.09.033</mixed-citation></ref><ref id="scirp.125850-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">CEN EN 13369 (2014) Common Rules for Precast Concrete Products. Afnor, Paris.</mixed-citation></ref><ref id="scirp.125850-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">El Marhoune, M., Lachheb, A., Saadani, R., Kabiri, M.R., Benyassi, M., Oussouaddin, O. and Rahmoune, M. (2017) An Experimental Investigation on the Thermophysical Properties of a Composite Basis of Natural Fibers of Alfa. International Journal of Mechanical &amp; Mechatronics Engineering IJMME-IJENS, 17, 27-32.</mixed-citation></ref><ref id="scirp.125850-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Saikia, N. and de Jorge, B. (2012) Use of Some Solid Waste Material as Aggregate, &amp;#64257;ller or &amp;#64257;ber in Cement Mortar and Concrete. Advances in Material Science Research, 3, 65-116.</mixed-citation></ref><ref id="scirp.125850-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Siddique, R., Khatib, J. and Kaur, I. (2008) Use of Recycled Plastic in Concrete: A Review. Waste Management, 28, 1835-1852. https://doi.org/10.1016/j.wasman.2007.09.011</mixed-citation></ref><ref id="scirp.125850-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">NF EN 12390-3 (2012) Tests for Hardened Concrete, Part 3: Compressive Strength of Specimens. Afnor, Paris.</mixed-citation></ref><ref id="scirp.125850-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Porrero, J., Ramos, C. and Grases, J.V.G.J. (2004) Manual del Concreto Estructural. Sidetur. Velazco Primera Edición Digital Caracas.</mixed-citation></ref><ref id="scirp.125850-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Rebeiz, K. and Fowler, D.W. (1996) Precast use of Polymer Concrete Using Unsaturated Polyester Resin Base on Recycled. Construction and Building Material, 10, 215-330. https://doi.org/10.1016/0950-0618(95)00088-7</mixed-citation></ref><ref id="scirp.125850-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Rossignolo, J.A. and Agnesini, M.V.C. (2002) Mechanical Properties of Polymer Modified Lightweight Aggregate Concrete. Cement Concrete Research, 32, 329-334. https://doi.org/10.1016/S0008-8846(01)00678-0</mixed-citation></ref><ref id="scirp.125850-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Saikia, N. and de Jorge, B. (2013) Waste Polyethylene Terephthalate as an Aggregate in Concrete. Materials Research, 16, 341-350. https://doi.org/10.1590/S1516-14392013005000017</mixed-citation></ref><ref id="scirp.125850-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">energieplus (2014) Caracteristiques thermiques des sols. https://energieplus-lesite.be/donnees/enveloppe44/caracteristiques-thermiques-des-sols/</mixed-citation></ref></ref-list></back></article>