<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OALibJ</journal-id><journal-title-group><journal-title>Open Access Library Journal</journal-title></journal-title-group><issn pub-type="epub">2333-9705</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/oalib.1109966</article-id><article-id pub-id-type="publisher-id">OALibJ-124473</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Business&amp;Economics</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Engineering</subject><subject> Medicine&amp;Healthcare</subject><subject> Physics&amp;Mathematics</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  Quality and Safety in the Phlebotomy Units of Medical Structures in Lubumbashi
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Eric</surname><given-names>Kasamba Ilunga</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Athy</surname><given-names>Kalumba Kambote</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Philomene</surname><given-names>Katende Masanka</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Emmanuel</surname><given-names>Prosper Malangu Mposhy</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Faculty of Veterinary Medicine, University of Lubumbashi, Lubumbashi, Democratic Republic of the Congo</addr-line></aff><aff id="aff1"><addr-line>Department of Biomedical Sciences, Faculty of Medicine, University of Lubumbashi, Lubumbashi, Democratic Republic of the Congo</addr-line></aff><pub-date pub-type="epub"><day>04</day><month>04</month><year>2023</year></pub-date><volume>10</volume><issue>04</issue><fpage>1</fpage><lpage>10</lpage><history><date date-type="received"><day>4,</day>	<month>March</month>	<year>2023</year></date><date date-type="rev-recd"><day>21,</day>	<month>April</month>	<year>2023</year>	</date><date date-type="accepted"><day>24,</day>	<month>April</month>	<year>2023</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  A correct pre-analytical phase procedure is essential to obtain an adequate sample, unfortunately this phase is littered with many errors and risks. It is within this framework that we carried out a survey in the laboratories of the city of Lubumbashi, Likasi and Kolwezi in the Democratic Republic of Congo and this by a questionnaire imposed on the heads of the laboratories. 3588 responses were validated and analyzed. Our results showed that the first line of the health level is more represented by Health Centers (CS), followed by Polyclinics, Reference Health Centers (CRS) and Hospitals Reference Generals (RGH). We have observed variations in the implementation of the reference standards on good sampling practice both in terms of general organization and in terms of risk management, for the staff and for the patient. What requires training, the establishment of a quality management system in phlebotomy units.
 
</p></abstract><kwd-group><kwd>Phlebotomy</kwd><kwd> Quality</kwd><kwd> Security</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Clinical laboratories play an important role in improving patient care, generating knowledge that can facilitate patient safety, improve patient outcomes, shorten patient journeys, and lead to more cost-effective healthcare [<xref ref-type="bibr" rid="scirp.124473-ref1">1</xref>] . Indeed, patient care and public health depend on the reliability and quality of clinical laboratory tests, as laboratory tests represent the most frequently ordered diagnostic procedures in all patient encounters [<xref ref-type="bibr" rid="scirp.124473-ref2">2</xref>] .</p><p>Venous blood sampling (phlebotomy) is the most common invasive procedure performed in patient care. Guidelines on the correct practice of phlebotomy are available, including the H3-A6 guideline issued by the Clinical Laboratory Standards Institute (CLSI) [<xref ref-type="bibr" rid="scirp.124473-ref3">3</xref>] . In Africa, most countries or even laboratory practitioners are unaware of the existence of these quality procedures related to the collection of venous blood samples and therefore an assessment of the quality and safety of phlebotomy units is essential and constitutes thus the purpose of this article.</p><p>Because the identification of reliable quality indicators (QI) is a crucial step to allow users to quantify the quality of laboratory services, the current lack of attention to extra-laboratory factors contrasts sharply with the body of evidence indicating the myriad of errors that continue to occur in the pre- and post-analytical phases [<xref ref-type="bibr" rid="scirp.124473-ref4">4</xref>] . This is why we conducted this study to identify the various problems in our phlebotomy units, in order to set up an improvement plan with effective corrective action.</p></sec><sec id="s2"><title>2. Method</title><p>Thus, through surveys and visits to laboratories in the cities of Likasi, Lubumbashi and Kolwezi, we were able to collect 3588 responses that we recorded using Google form and analyzed using Microsoft Excel 365 for the representation forms form of Pie charts, histograms and tables and with Epi Info 7.3 in order to calculate the relative risk and the Confidence intervals on the wearing of PPE.</p></sec><sec id="s3"><title>3. Results and Discussion</title><p>From <xref ref-type="fig" rid="fig1">Figure 1</xref>, we observe that Health Centers are the most represented structures (73.6%) in the cities of our study, followed by polyclinics (19.78%), Reference Health Centers (3.85%) and General Hospitals of Reference (2.73%). The observation thus made shows an increased number of first-line structures, an</p><p>observation also made by Chenge et al. in their article entitled: The health map of the city of Lubumbashi, Democratic Republic of Congo Part I: problem of health coverage in urban areas Congolese ; his results reveal an exponential evolution in the number of first-line structures [<xref ref-type="bibr" rid="scirp.124473-ref5">5</xref>] and likewise Samuel Bosongo et al. affirms that in Kisangani in the Democratic Republic of Congo, the services of doctors on the first line is a de facto situation, unplanned and unsupported, which is largely due to the need for professional integration of doctors [<xref ref-type="bibr" rid="scirp.124473-ref6">6</xref>] . This phenomenon does not correspond to the current health policy because front-line service is devolved to nurse practitioners [<xref ref-type="bibr" rid="scirp.124473-ref7">7</xref>] .</p><p>The verification of the implementation of quality parameters in phlebotomy units according to the health level shows that a glaring absence of sampling procedure in around 80% and this regardless of the health level and in contrast, the presence of Job Aids of samples appears from 61% to 84% depending on whether one passes from Health Center, RGH, HRC and polyclinics. And about the training of phlebotomists, it was effective in turns of 43% in the HC, 60.1% in the polyclinics, 61.1% in the CSR, and 70.4% in the HGR (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><p>It should be noted here that the training of phlebotomists is of great necessity to master the pre-analytical part in the laboratory, a very crucial phase regarding the quality of the results, as the concept “Garbage in Garbage out” says: The quality of the output is determined by the quality of the input. Indeed, it is that Gabriel Lima-Oliveira et al. found that training phlebotomists for 20 days eliminated non-compliance procedures [<xref ref-type="bibr" rid="scirp.124473-ref8">8</xref>] and compliance with the exact procedure of blood collection by venipuncture from the according to CLSI/NCCLS H03-A6 improves the quality of the process [<xref ref-type="bibr" rid="scirp.124473-ref3">3</xref>] . Because indeed, a correct organization or management of the personnel and the procedures relating to blood sampling by venipuncture are of fundamental importance, because the various stages of realization of the blood sampling represent in themselves sources of variability in the laboratory [<xref ref-type="bibr" rid="scirp.124473-ref9">9</xref>] .</p><p>It should be noted that there is a mismatch between v the presence of Direct Debit Procedures on the one hand and that of JobAid on the other; in the phlebotomy units, the present job aids are part of the documents provided after training, in most cases, in the care and diagnosis of HIV/AIDS.</p><p>About the Organization of safety in the phlebotomy units, we observe from <xref ref-type="fig" rid="fig3">Figure 3</xref> a use at each level of appropriate single-use materials and good storage of workstations in the CS and CSR and less in polyclinics and HGR and this in the almost very high absence of safety pictograms, which we have noticed in around 15% of structures at all levels combined.</p><p>We also note the presence of bins with unsoiled objects respectively at 71%, 82%, 91% and 87% depending on whether one is in the phlebotomy units of the CS, CSR, HGR and Polyclinics; which is the opposite of the presence of soiled Object bins which are becoming rarer. The situation deteriorates further when it comes to sharp object bins, which are only used at 14.5% in CS, 28.7% in CSR, 34.6% in HGR and 18.59% in polyclinics.</p><p>The evidence of cleaning of surfaces by the presence of the sheets, is not very present in the CS and sufficiently present in the CSR, HGR and Polyclinics. We also observe, the use at 52% and 60% in the CSR and HGR, while in the CS and polyclinics the use is successively at 36.9% and 32.1%.</p><p>The safety of healthcare workers and patients is the main concern during phlebotomy procedures; this is why it is essential to have guidelines guiding staff towards best practices [<xref ref-type="bibr" rid="scirp.124473-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.124473-ref11">11</xref>] . Thus, all staff members must be trained in phlebotomy to prevent unnecessary risks of exposure to blood and to reduce adverse events affecting patients and this training must at least cover the essential points [<xref ref-type="bibr" rid="scirp.124473-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.124473-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.124473-ref14">14</xref>] whose purposes of this training are patient safety, adequacy of laboratory specimens, and the safety of health care workers and the community.</p><p>And in this specific case, it is the anatomy of the phlebotomy sites that the health worker is allowed to access; infection prevention and control; patient protection; health worker protection; types of equipment available for blood collection and acquisition and use of such equipment; adverse events and their management; occupational exposures and their management; waste management, including disposal of waste and sharps/sharps and spill or breakage procedures. Laboratory practices, including sample types, forms, labeling and transport; as well as the standards of practice that define the points followed in this investigation [<xref ref-type="bibr" rid="scirp.124473-ref15">15</xref>] .</p><p>The concern for quality monitoring, observed by the notification of complaints, non-conformities as well as the recording of rejection of samples is better monitored in the polyclinics, then in the HGR, the CSR and finally in CS. Indeed, WHO guidelines for blood collection: best practice in phlebotomy require that a monitoring and evaluation system be in place to monitor the management of phlebotomy services and the management of adverse events, as well as to save improvements. This system must monitor the indicators, those identified in <xref ref-type="fig" rid="fig4">Figure 4</xref> [<xref ref-type="bibr" rid="scirp.124473-ref15">15</xref>] .</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows that the safety of the phlebotomist is ensured in satisfactory ways for the wearing of gloves, followed by that of the wearing of medical boots and finally the wearing of PPE; on the other hand, the wearing of glasses and the presence of first aid kits are not ensured in a satisfactory manner and in compliance with the recommendations of the WHO which gives the following details:</p><p>Regarding personal protection that health workers should wear tight-fitting sterile gloves when taking blood samples; they must also practice hand hygiene before and after each act on a patient and before putting on and after taking off their gloves [<xref ref-type="bibr" rid="scirp.124473-ref16">16</xref>] .</p><p>Regarding the safe disposal of sharp objects [<xref ref-type="bibr" rid="scirp.124473-ref17">17</xref>] , the collection device: a needle and syringe, a needle and an evacuated tube holder or a butterfly needle ? must be disposed of immediately after use without being disassembled. It should be placed in a closed, leak-proof, puncture-resistant sharps/sharps container that is installed so that it is clearly visible and within easy reach of the health-care worker [<xref ref-type="bibr" rid="scirp.124473-ref18">18</xref>] .</p><p>Wearing gloves can reduce the acquisition of microorganisms on the hands. But it does not completely prevent hand contamination. Also, improper use of gloves may increase the risk of cross-transmission through contaminated gloved hands [<xref ref-type="bibr" rid="scirp.124473-ref19">19</xref>] .</p><p><xref ref-type="table" rid="table1">Table 1</xref> shows the follow-up of the respect of the wearing of Epis, it appears from this table that there is a statistically significant association between the wearing of Epis and the various components including: gloves, glasses, and medical boots. This association, with an RR &gt; 1, testifies to an increase in the frequency of the event, which is also a beneficial effect provided by wearing Epis in combination with gloves, glasses, and medical boots. This is because the more parts of the body covered in PPE, the better the protection it provides. However, this is also associated with increased difficulty in donning and doffing PPE, and PPE is less comfortable. Coveralls are the most difficult PPE to remove, but they can provide the most protection [<xref ref-type="bibr" rid="scirp.124473-ref20">20</xref>] . In this regard, one of the objectives of wearing Epis is to cover a larger part of the body which leads to better protection. However, as is usually associated with increased difficulty putting on and taking off PPE. This is so following CDC guidelines for removal of apron or gown, or any instructions for removing PPE should be required [<xref ref-type="bibr" rid="scirp.124473-ref21">21</xref>] .</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> points out at each health level, each laboratory uses syringes and vacuum tubes for blood sampling, and they sometimes use vacuum needles (68.89% in the HC, 83.5% in the polyclinics, 86.3% in the HCR and 96.9% in the</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Monitoring of wearing safety of EPIS</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >PPE</th><th align="center" valign="middle" >No</th><th align="center" valign="middle" >Yes</th><th align="center" valign="middle" >p-Value</th><th align="center" valign="middle" >RR</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >Gloves</td><td align="center" valign="middle" >Non</td><td align="center" valign="middle" >28</td><td align="center" valign="middle" >798</td><td align="center" valign="middle"  rowspan="2"  >0.00</td><td align="center" valign="middle"  rowspan="2"  >4.92 [2.76 - 8.77]</td></tr><tr><td align="center" valign="middle" >Oui</td><td align="center" valign="middle" >19</td><td align="center" valign="middle" >2743</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Glasses Ports</td><td align="center" valign="middle" >Non</td><td align="center" valign="middle" >686</td><td align="center" valign="middle" >140</td><td align="center" valign="middle"  rowspan="2"  >0.00</td><td align="center" valign="middle"  rowspan="2"  >1.36 [1.31 - 1.42]</td></tr><tr><td align="center" valign="middle" >Oui</td><td align="center" valign="middle" >1676</td><td align="center" valign="middle" >1086</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Wearing Medical Boots</td><td align="center" valign="middle" >Non</td><td align="center" valign="middle" >301</td><td align="center" valign="middle" >525</td><td align="center" valign="middle"  rowspan="2"  >0.00</td><td align="center" valign="middle"  rowspan="2"  >2.25 [1.99 - 2.55]</td></tr><tr><td align="center" valign="middle" >Oui</td><td align="center" valign="middle" >446</td><td align="center" valign="middle" >2316</td></tr></tbody></table></table-wrap><p>RGH). With reuse of the cylinder around 50% of the structures for the sanitary level sets.</p><p>We note the reuse in many laboratories of penicillin vials for the collection of urine and stool. The presence of water points for hand washing is more present in RGH and HCR (91%) followed by polyclinics (87.8% at and HC (78.8%). The sample coding system is only present at 81.6% in the HGR, 70.9% in the clinics 67% in the CSR and 58% in the HC The storage system was present respectively at 82.65% for the RGH, 74% for the Polyclinics, 71% for HCR and 64.63% for HC It is true that the use of vacuum extraction tube systems as closed systems for blood collection reduces the risk of direct exposure to blood and facilitates the collection of multiple samples from a single venipuncture. And these systems are widely available in most countries with sufficient resources [<xref ref-type="bibr" rid="scirp.124473-ref22">22</xref>] .</p><p>Also, the choice of blood collection tube has a significant effect on the detected metabolites and their overall abundance [<xref ref-type="bibr" rid="scirp.124473-ref23">23</xref>] .</p><p>Regarding the sample coding and storage system, JL Dhondt believes that the pre-analytical phase must require all attention to ensure the quality of the prescribed analyzes and the identification of the tubes is a key step, especially that, in the continuation of the assumption of the biological file [<xref ref-type="bibr" rid="scirp.124473-ref24">24</xref>] . Paul N Valenstein and Ronald L Sirota believe that misidentification involves misidentification of a patient or specimen. Either has the potential to harm patients. These errors can occur at any part of the test cycle; however, most occur in the pre-analytical phase [<xref ref-type="bibr" rid="scirp.124473-ref25">25</xref>] . Hence the need to properly organize the system for storing and coding the samples to minimize their occurrence, and that special attention should be given during the pre-analytical phase. Because for the clinical laboratory, the errors of the pre-analytical phase of the tests vary up to 75% of the total laboratory errors; 26% of them can have adverse effects on patient care, and contribute to unnecessary investigations or inappropriate treatments, increased lengths of hospitalization, as well as dissatisfaction with health services [<xref ref-type="bibr" rid="scirp.124473-ref26">26</xref>] .</p><p>While reusing tourniquets may compromise patient safety [<xref ref-type="bibr" rid="scirp.124473-ref27">27</xref>] , so will reusing the barrel, as it has been shown that tourniquets used for peripheral venous vascular access such as blood samples are regularly contaminated by clinical routine [<xref ref-type="bibr" rid="scirp.124473-ref28">28</xref>] . The facts mentioned above also apply to the reuse of drug vials for the collection of stool or urine samples.</p></sec><sec id="s4"><title>4. Conclusion</title><p>Laboratory testing, an extraordinarily complex process usually subdivided into three traditional analytical phases (pre-analytical, analytical, and post-analytical). Many errors come from the pre-analytical phase, being due to individual or system design flaws. To reduce errors, the pre-analytical phase must therefore be preferred. In addition to the purchase of equipment, the development of procedures and training, the establishment of a quality management system in the laboratory can be a tool to reduce errors in sample collection and the handling of pre-samples.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest.</p></sec><sec id="s6"><title>Cite this paper</title><p>Ilunga, E.K., Kambote, A.K., Masanka, P.K. and Mposhy, E.P.M. (2023) Quality and Safety in the Phlebotomy Units of Medical Structures in Lubumbashi. Open Access Library Journal, 10: e9966. https://doi.org/10.4236/oalib.1109966</p></sec></body><back><ref-list><title>References</title><ref id="scirp.124473-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Beastall, G.H. (2013) Adding Value to Laboratory Medicine: A Professional Responsibility. Clinical Chemistry and Laboratory Medicine (CCLM), 51, 221-227.  
https://doi.org/10.1515/cclm-2012-0630</mixed-citation></ref><ref id="scirp.124473-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Ngo, A., Gandhi, P. and Miller, W.G. (2017) Frequency that Laboratory Tests Influence Medical Decisions. The Journal of Applied Laboratory Medicine, 1, 410-414.  
https://doi.org/10.1373/jalm.2016.021634</mixed-citation></ref><ref id="scirp.124473-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Clinical and Laboratory Standards Institute (CLSI) (2007) Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard—Sixth Edition. CLSI Document H3-A6 (ISBN 1-56238-650-6), Clinical and Laboratory Standards Institute.</mixed-citation></ref><ref id="scirp.124473-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Plebani, M., Sciacovelli, L., Marinova, M., Marcuccitti, J. and Chiozza, M.L. (2013) Quality Indicators in Laboratory Medicine: A Fundamental Tool for Quality and Patient Safety. Clinical Biochemistry, 46, 1170-1174.  
https://doi.org/10.1016/j.clinbiochem.2012.11.028</mixed-citation></ref><ref id="scirp.124473-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Chenge, M., Van der Vennet, J., Porignon, D., Luboya, N., Kabyla, I. and Criel, B. (2010) La carte sanitaire de la ville de Lubumbashi, République Démocratique du Congo. Partie I: Problématique de la couverture sanitaire en milieu urbain congolais. [The Health Map of Lubumbashi, Democratic Republic of the Congo. Part I: Problem of Health Coverage in Urban Congolese]. Global Health Promotion, 17, 63-74. (In French) https://doi.org/10.1177/1757975910375173</mixed-citation></ref><ref id="scirp.124473-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Bosongo, S., Chenge, F., Mwembo, A. and Crielnt, B. (2021) L’influence des prestations des médecins à la première ligne de soins sur le système intégré de district sanitaire à Kisangani, République Démocratique du Congo: Une étude qualitative. Pan African Medical Journal, 39, Article 215.  
https://doi.org/10.11604/pamj.2021.39.215.25737</mixed-citation></ref><ref id="scirp.124473-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Bosongo, S.I., Mukalenge, F.C., Tambwe, A.M. and Criel, B. (2021) [Les médecins prestataires à la première ligne des soins dans la ville de Kisangani en République Démocratique du Congo: Vers une typologie]. African Journal of Primary Health Care &amp; Family Medicine, 13, a2617. (In French)  
https://doi.org/10.4102/phcfm.v13i1.2617</mixed-citation></ref><ref id="scirp.124473-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Lima-Oliveira, G., Lippi, G., Salvagno, G.L., Montagnana, M., Picheth, G. and Guidi, G.C. (2012) Impact of the Phlebotomy Training Based on CLSI/NCCLS H03-a6—Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture. Biochemia Medica, 22, 342-351. https://doi.org/10.11613/BM.2012.036</mixed-citation></ref><ref id="scirp.124473-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G. and Guidi, G.C. (2017) Pre-Analytical Phase Management: A Review of the Procedures from Patient Preparation to Laboratory Analysis. Scandinavian Journal of Clinical and Laboratory Investigation, 77, 153-163. https://doi.org/10.1080/00365513.2017.1295317</mixed-citation></ref><ref id="scirp.124473-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">World Health Organization (WHO)/International Labour Organization (ILO) (2008) Guidelines on Post Exposure Prophylaxis (PEP) to Prevent Human Immunodeficiency Virus (HIV) Infection. OMS/BIT.</mixed-citation></ref><ref id="scirp.124473-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Health Protection Authority (HPA) (2005) Eye of the Needle—Surveillance of Significant Occupational Exposure to Blood-Borne Viruses in Healthcare Personnel. HPA.</mixed-citation></ref><ref id="scirp.124473-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Sacar, S., et al. (2006) Poor Hospital Infection Control Practice in Hand Hygiene, Glove Utilization, and Usage of Tourniquets. American Journal of Infection Control, 34, 606-609. https://doi.org/10.1016/j.ajic.2006.02.006</mixed-citation></ref><ref id="scirp.124473-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Rourke, C., Bates, C. and Read, R. (2001) Poor Hospital Infection Control Practice in Blood Sampling and Use of Tourniquets. Journal of Hospital Infection, 49, 59-61.  
https://doi.org/10.1053/jhin.2001.1038</mixed-citation></ref><ref id="scirp.124473-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Kermode, M. (2004) Health Worker Safety Is a Prerequisite for Injection Safety in Developing Countries. International Journal of Infectious Diseases, 8, 325-327.  
https://doi.org/10.1016/j.ijid.2004.03.005</mixed-citation></ref><ref id="scirp.124473-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">WHO (2010) Guidelines on Drawing Blood: Best Practices in Phlebotomy.</mixed-citation></ref><ref id="scirp.124473-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Kiechle, F.L. (2007) So You’re Going to Collect a Blood Specimen: An Introduction to Phlebotomy. 12th Edition, College of American Pathologists.</mixed-citation></ref><ref id="scirp.124473-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Organisation mondiale de la Santé (2005) Gestion des déchets d’activités de soins solides dans les centres de soins de santé primaires: Guide d’aide à la décision. Organisation mondiale de la Santé.  
http://whqlibdoc.who.int/publications/2005/9242592749_fre.pdf</mixed-citation></ref><ref id="scirp.124473-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Corey, K.E., et al. (2009) Pilot Study of Postexposure Prophylaxis for Hepatitis C virus in Healthcare Workers. Infection Control and Hospital Epidemiology, 30, 1000-1005. https://doi.org/10.1086/605718</mixed-citation></ref><ref id="scirp.124473-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Picheansanthian, W. and Chotibang, J. (2015) Glove Utilization in the Prevention of cross Transmission: A Systematic Review. JBI Database of Systematic Reviews and Implementation Reports, 13, 188-230.  
https://doi.org/10.11124/01938924-201513040-00013</mixed-citation></ref><ref id="scirp.124473-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Hegde, S. (2020) Which Type of Personal Protective Equipment (PPE) and which Method of Donning or Doffing PPE Carries the Least Risk of Infection for Healthcare Workers? Evidence-Based Dentistry, 21, 74-76.  
https://doi.org/10.1038/s41432-020-0097-3</mixed-citation></ref><ref id="scirp.124473-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Verbeek, J.H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J.H. and Balci, F.S.K. (2020) Personal Protective Equipment for Preventing Highly Infectious Diseases Due to Exposure to Contaminated Body Fluids in Healthcare Staff. Cochrane Database of Systematic Reviews, 4, CD011621.  
https://doi.org/10.1002/14651858.CD011621.pub4</mixed-citation></ref><ref id="scirp.124473-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">WHO. (2010) WHO Guidelines on Drawing Blood: Best Practices in Phlebotomy. World Health Organization.</mixed-citation></ref><ref id="scirp.124473-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Cruickshank-Quinn, C., Zheng, L.K., Quinn, K., Bowler, R., Reisdorph, R. and Reisdorph, N. (2018) Impact of Blood Collection Tubes and Sample Handling Time on Serum and Plasma Metabolome and Lipidome. Metabolites, 8, Article 88.  
https://doi.org/10.3390/metabo8040088</mixed-citation></ref><ref id="scirp.124473-ref24"><label>24</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Dhondt</surname><given-names> J.L. </given-names></name>,<etal>et al</etal>. (<year>2001</year>)<article-title>Le cha&amp;icirc;non manquant: Qualité de l’identification et phase pré-analytique [The Missing Link: Quality in the Identification and Preanalytic Phase]</article-title><source> Annales de Biologie Clinique</source><volume> 59</volume>,<fpage> 231</fpage>-<lpage>232</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.124473-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Valenstein, P.N. and Sirota, R.L. (2004) Identification Errors in Pathology and Laboratory Medicine. Clinics in Laboratory Medicine, 24, 979-996,  
https://doi.org/10.1016/j.cll.2004.05.013</mixed-citation></ref><ref id="scirp.124473-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Green, S.F. (2013) The Cost of Poor Blood Specimen Quality and Errors in Preanalytical Processes. Clinical Biochemistry, 46, 1175-1179.  
https://doi.org/10.1016/j.clinbiochem.2013.06.001</mixed-citation></ref><ref id="scirp.124473-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Salgueiro-Oliveira, A.S., Costa, P.J.D.S., Braga, L.M., Graveto, J.M.G.N., Oliveira, V.S. and Parreira, P.M.S.D. (2019) Health Professionals’ Practices Related with Tourniquet Use during Peripheral Venipuncture: A Scoping Review. Revista Latino-Americana de Enfermagem, 27, e3125.</mixed-citation></ref><ref id="scirp.124473-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Grohmann, M., Schomakers, L., Wolschendorf, F., Grosch, J., Lindner, S. and Witte, A.K. (2020) Reduced Bacterial Contamination Rates Detected on Silicone Tourniquets Compared to Conventional Tourniquets in Clinical Routine. BMC Infectious Diseases, 20, Article No. 247. https://doi.org/10.1186/s12879-020-04975-y</mixed-citation></ref></ref-list></back></article>