<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JMMCE</journal-id><journal-title-group><journal-title>Journal of Minerals and Materials Characterization and Engineering</journal-title></journal-title-group><issn pub-type="epub">2327-4077</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jmmce.2023.112003</article-id><article-id pub-id-type="publisher-id">JMMCE-123888</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Auxetics in Biomedical Applications: A Review
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Sean</surname><given-names>Rose</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Dexter</surname><given-names>Siu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>JD</surname><given-names>Zhu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Reem</surname><given-names>Roufail</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada</addr-line></aff><pub-date pub-type="epub"><day>27</day><month>03</month><year>2023</year></pub-date><volume>11</volume><issue>02</issue><fpage>27</fpage><lpage>35</lpage><history><date date-type="received"><day>23,</day>	<month>February</month>	<year>2023</year></date><date date-type="rev-recd"><day>24,</day>	<month>March</month>	<year>2023</year>	</date><date date-type="accepted"><day>27,</day>	<month>March</month>	<year>2023</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Materials exhibiting auxetic properties have a negative Poisson’s ratio, which intrigued researchers to understand the behavior of auxetic structure. Several researchers focused on the different auxetic cell designs, while others focused on the auxetic applications. With the advance of additive manufacturing methods, computer-aided design and finite element analysis in recent decades, auxetics have been explored. One of the interesting applications is in the field of biomedical devices or implants, especially for certain natural biomedical organs such as tissues, certain ligaments that have auxetic properties. This paper is an overview of auxetic design approaches and biomedical applications.
 
</p></abstract><kwd-group><kwd>Auxetics</kwd><kwd> Negative Poisson’s Ratio</kwd><kwd> Biomaterials</kwd><kwd> Biomedical Engineering</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><sec id="s1_1"><title>1.1. Poisson’s Ratio and Auxetic Properties</title><p>Poisson’s ratio plays an important role in providing a unique strain performance in the transverse direction relative to axial direction. It measures the relative deformation of the material in the perpendicular direction, relative to the deformation at the applied load direction. If the force load is applied in tension, the material will increase in length in the direction of the loading, (axial), while the perpendicular direction (transverse) will decrease in length to conserve the volume change of the material. If the material is exposed to compression, the phenomena will hold, but the deformation direction will reverse. The mathematical equation for Poisson ratio has a negative sign to account for the decrease in the dimension of the strain, as shown in Equation (1).</p><p>v = − ϵ Transverse ϵ Axial (1)</p><p>If the material dimension increases in all directions in tensile loading or decreases in dimension in all directions in compressive loading, the result of the Poisson ratio equation will be negative. Materials with a negative Poisson’s ratio are classified as auxetics.</p><p>Auxetic materials exhibit synclastic behavior, where the material displays a dome shape when subjected to bending, in contrast to the typical saddle shape for materials with a positive Poisson’s ratio [<xref ref-type="bibr" rid="scirp.123888-ref1">1</xref>]. Auxetic materials also present higher amounts of indentation resistance when compressive loads are applied, in addition to higher fracture propagation [<xref ref-type="bibr" rid="scirp.123888-ref1">1</xref>]. Another observed property of auxetic materials is vibration damping of various patterns of auxetic structure, which can dampen up to 10 times more if the same material did not have an auxetic structure design [<xref ref-type="bibr" rid="scirp.123888-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.123888-ref2">2</xref>]. This leads to the use of auxetic structure for acoustic absorption, and various sound-related applications [<xref ref-type="bibr" rid="scirp.123888-ref2">2</xref>]. Another important feature of auxetic materials is their unique anisotropy, which can achieve different properties in distinct directions that are impossible by a material that has a positive Poisson’s ratio [<xref ref-type="bibr" rid="scirp.123888-ref2">2</xref>].</p><p>Due to the anisotropic nature of the auxetic material, loading in the axial direction will yield different stresses, strains, and deformation patterns compared with loading along the transverse direction [<xref ref-type="bibr" rid="scirp.123888-ref3">3</xref>]. Additionally, auxetic properties are lost after yield stress is observed within the material due to deformation beyond the elastic region [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>]. However, materials that have a low negative Poisson’s ratio often have fewer other favorable mechanical properties, creating a fine line between mechanical and auxetic properties for most applications [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>]. Thus, it is important to consider the direction, magnitude, and type of loading when analyzing auxetic materials to maximize the utilization of the auxetic function of the material.</p></sec><sec id="s1_2"><title>1.2. Design and Analysis of Auxetics</title><sec id="s1_2_1"><title>1.2.1. Geometric Designs</title><p>Auxetic materials have a common feature as all designs can be broken down into specific unit cell designs that provide the structure with the unique aforementioned properties. These unit cell designs range from common material structures to ones that exist on the molecular level, as seen in some inorganic microstructure crystals [<xref ref-type="bibr" rid="scirp.123888-ref5">5</xref>]. There are different geometries that provide negative Poisson’s ratio property, such as the S-shaped unit cell, which was explored by Meena, K. and Singamneni, S., 2019 [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>] and the re-entrant unit cell, which was explored by Y. Zhu et al., 2022 [<xref ref-type="bibr" rid="scirp.123888-ref6">6</xref>]. A major challenge of unit cell design is the complexity of the detailed design relative to the load capacity that the structure can handle [<xref ref-type="bibr" rid="scirp.123888-ref3">3</xref>]. One of the parameters that should be considered as a constraint to each design is the direction of loading and maximum allowable load capacity due to the high stress zones of the structure [<xref ref-type="bibr" rid="scirp.123888-ref3">3</xref>]. Unit cell designs are affected by the network of cells attached to it and the direction of loading. One of the most common designs considered for research and products is the re-entrant unit cell. This design has been studied in numerous applications, such as cardiac patches by Kapnisi M. et al., 2018 [<xref ref-type="bibr" rid="scirp.123888-ref7">7</xref>], oesophageal stents by M. N. Ali et al., 2014 [<xref ref-type="bibr" rid="scirp.123888-ref8">8</xref>], and heel pads by M.S.-H. Leung et al., 2022 [<xref ref-type="bibr" rid="scirp.123888-ref9">9</xref>]. The S-shaped unit cell (right) and re-entrant unit cell are displayed in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p></sec><sec id="s1_2_2"><title>1.2.2. Finite Element Analysis</title><p>The fields of mechanics and materials clearly illustrate the difference between theoretical values obtained from technological analysis and actual values obtained through mechanical testing. Oftentimes, auxetics are tested through physical loading of specimens to measure the observed stress and strain values. It is also common for the use of Finite Element Analysis (FEA) models to simulate the auxetic performance, using various software packages, such as Ansys, ABAQUS and Solid Works.</p><p>Finite Element Analysis software allows for a simulation of the deformations and critical stress values that will occur in different materials, shapes and interactions utilizing computer-aided design (CAD) models. The software allows for visualization of common concepts that cannot be physically seen, such as Von-mises stresses, displaying the varying magnitudes of stress distribution on the CAD model of the auxetic structure. It also shows the deformation and strain on the structure at different loading levels and directions. FEA software is used to run multiple iterations that would cost time and money if they were all designed and fabricated for testing. It assists in limiting the number of prototypes for testing. Finite element analyses are also utilized to identify the performance of different materials on the same auxetic design and loading limits.</p><p>There are no standards or specifications that can be followed when designing auxetic structures that would lead to pre-defined negative Poisson ratio values. Designing negative Poisson ratio material follows an empirical approach. One of the observations is that the geometry of the auxetic structure has a direct impact on the overall performance. Unit cells that have sharper angles lead to stress</p><p>points of larger magnitudes (stress concentration), ultimately leading to prematurefailure [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>]. Meena, K. and Singamneni, S., 2019 [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>] performed FEA models of both the S-shaped and re-entrant unit cells and concluded that the sharp internal corners ultimately led to the earlier failure of the re-entrant cell compared to the smoother internal edges of the S-shaped cell. It was also determined that re-entrant unit cells with an internal angle of 75˚ exhibited the optimal auxetic response when loaded. Other interesting observations were made, such as unique deformations along areas that are rotationally symmetrical, with identical deformation patterns [<xref ref-type="bibr" rid="scirp.123888-ref4">4</xref>].</p><p>Further studies on auxetic design and performance are needed in order to adapt them for specific applications. Other researchers adopted the design for an application approach. Due to their unique performance, auxetic materials can be used in a vast variety of applications, including the biomedical field.</p><p>The use of auxetics in the biomedical field has become popular due to the use of auxetic biomaterials [<xref ref-type="bibr" rid="scirp.123888-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.123888-ref11">11</xref>]. An auxetic biomaterial is simply an auxetic structure manufactured from a material derived from a biocompatible material such as protein-based hydrogel [<xref ref-type="bibr" rid="scirp.123888-ref12">12</xref>]. It is most common for these structures to be produced with 3D printing methods [<xref ref-type="bibr" rid="scirp.123888-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.123888-ref12">12</xref>]. This paper focuses on specific examples of biomedical applications of auxetic structures that have been used in various studies.</p></sec></sec><sec id="s1_3"><title>1.3. Biomedical Application of Auxetics</title><p>Physiological aspects of various fields can be improved through the implementation of auxetic properties into already-existing devices. One common example includes the synclastic behavior of helmets, which increases the protection provided to the user’s head upon impact [<xref ref-type="bibr" rid="scirp.123888-ref1">1</xref>]. These properties can also be expanded to a wide range of other protective equipment to allow for lighter weight and increased comfort [<xref ref-type="bibr" rid="scirp.123888-ref2">2</xref>].</p><p>K. Saxeen et al., 2016 [<xref ref-type="bibr" rid="scirp.123888-ref2">2</xref>] have illustrated numerous biomedical applications for auxetic structures. The uses can be divided into various categories such as implant devices, medical or surgical devices. Some of the most noteworthy implant applications include auxetic stents that reduce inflammation inside the body, and artificial blood vessels. Some procedures include dental floss, surgical sutures, and even smart bandages.</p></sec></sec><sec id="s2"><title>2. Biomedical Applications</title><sec id="s2_1"><title>2.1. Tissue Engineering</title><p>Tissue engineering aims to restore damaged tissue functions using biomaterials. Tissues engineered with an auxetic internal structure can potentially better mimic the mechanical properties of the original tissues than the ordinary engineered tissues. Tendons, vasculature, cancellous bone, embryonic epithelial tissues, arteries, and the annulus fibrosus of the intervertebral disc all have auxetic properties [<xref ref-type="bibr" rid="scirp.123888-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.123888-ref13">13</xref>].</p><p>It is a common practice for researchers to use computer-aided design software and finite element method to evaluate mechanical properties and compare them with experimental data. Warner et al., 2017 [<xref ref-type="bibr" rid="scirp.123888-ref10">10</xref>] found that modified unit-cell architecture with stabilized rounded hinges is effective at transmitting displacement throughout the structure and can minimize out-of-plane deflections using FEA. Combined with further research, these findings can potentially be used in tendon-muscle tissue regeneration. Kapnisi M. et al., 2018 [<xref ref-type="bibr" rid="scirp.123888-ref7">7</xref>] compared the theoretical resultant effective stiffness and anisotropic ratio of effective stiffness using an analytical model established by I. G. Masters and K. E. Evans, 1996 [<xref ref-type="bibr" rid="scirp.123888-ref14">14</xref>] with the experimental data collected, and an agreement was discovered between the two researchers.</p><p>R. Ajdary et al., 2022 [<xref ref-type="bibr" rid="scirp.123888-ref15">15</xref>] fabricated bacterial nanocellulose (BNC) with triangular, circular and star unit cell shapes using molds designed in SolidWorks. The Poisson’s ratios of −0.19, −0.36, and −0.13 are found for the triangular, circular, and star unit cells, respectively. The auxetic BNC meshes obtained after cell culturing can have a tensile strength up to 456 MPa depending on the cell culturing time. The reversible structural expansion under tension minimizes the tissue damage that commonly occurs by shrinkage of plastic-based mesh implants, and is expected to maximize comfort, minimize material fatigue, and thus improve the overall success of future long-term mesh implants.</p><p>M. N. Ali et al., 2014 [<xref ref-type="bibr" rid="scirp.123888-ref8">8</xref>] simulated the auxetic esophageal stent using a single square FEA model and an auxetic-ring FEA model in ABAQUS. The auxetic polyurethane film is compared with the auxetic film model derived from a single square FEA model extracted from the auxetic film for simplicity and accuracy, shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The rigid auxetic polyurethane stent is comparable with the auxetic-ring FEA model. The two FEA models are concluded to be in good agreement with the experiment.</p><p>The M. N. Ali et al., 2014 [<xref ref-type="bibr" rid="scirp.123888-ref8">8</xref>] expected the auxetic esophageal stent with anisotropic mechanical behavior to conform well to the multilayered esophageal wall with a non-linear anisotropic mechanical response. Additionally, the small auxetic stent graft can be delivered orally into the esophagus without the use of an expensive dedicated delivery device using a balloon catheter [<xref ref-type="bibr" rid="scirp.123888-ref16">16</xref>]. With further study, such auxetic esophageal stents can potentially replace the current esophageal stents.</p></sec><sec id="s2_2"><title>2.2. Implants</title><p>The auxetic pedicle screw proposed by Y. Yao et al., 2020 [<xref ref-type="bibr" rid="scirp.123888-ref17">17</xref>] is reported to have an improved fixation strength, while the femur auxetic meta-implant proposed by N. Ghavidelnia et al., 2021 [<xref ref-type="bibr" rid="scirp.123888-ref18">18</xref>] is reported to reduce the stress shielding and micromotions.</p><p>Y. Yao et al., 2021 [<xref ref-type="bibr" rid="scirp.123888-ref19">19</xref>] conducted thorough mechanical tests experimentally and computationally using FEA on the designed auxetic pedicle screw. Predictions by the FEA simulations are consistent with experimental results, but there are discrepancies between FEA and experimental results, including higher tensile stiffness, tensile strength and Poisson’s ratio [<xref ref-type="bibr" rid="scirp.123888-ref17">17</xref>]. The auxetic pedicle screw can improve bone-screw fixation by its radial expansion of the screw body under tensile force to resist pulling out. The pullout force was increased by 6.29% - 14.46% compared to that of the solid screw; however, a few auxetic screws have fewer pullout forces than the solid screw [<xref ref-type="bibr" rid="scirp.123888-ref19">19</xref>]. N. Ghavidelnia et al., 2021 [<xref ref-type="bibr" rid="scirp.123888-ref18">18</xref>] focused on developing an analytical solution with FEA and found the femur auxetic meta-implants to have enhanced stress and strain distributions and a more compatible and uniform distribution of micromotion.</p></sec><sec id="s2_3"><title>2.3. Other Biomedical Applications</title><p>Biomaterials with auxetic properties usually have complex geometry, making it difficult for researchers to design and analyze. However, with the increasing computation power in recent decades, researchers can incorporate auxetics in some other biomedical applications.</p><p>A. Bonfanti and A. Bhaskar, 2019 [<xref ref-type="bibr" rid="scirp.123888-ref20">20</xref>] proposed a wrinkle-resistant auxetic film to tackle the wrinkling problem of synthetic skin. The auxetic films showed the ability to be stretched without forming wrinkles with experiments, analytical solutions, and FEA. The wrinkle-resistant auxetic film can be a promising candidate for future applications such as artificial skin, cardiac patches, and biomedical stretchable sensors.</p><p>A. Arjunan et al., 2021 [<xref ref-type="bibr" rid="scirp.123888-ref21">21</xref>] developed a one size fits all auxetic nasopharyngeal swab that can be easily 3D printed. The FE model overestimates the yield and peak forces by 4.30% and 3.87% respectively, but the force-displacement curve of the swab heads shows that the FE model agrees with experimental results. The swab head can reduce patient discomfort by shrinking inward while navigating the nasal cavity, thus exerting a reduced stress on surrounding tissue compared to a regular swab.</p><p>V. Gupta and A. Chanda, 2023 [<xref ref-type="bibr" rid="scirp.123888-ref22">22</xref>] developed skin graft computational models using I-shaped auxetic incision structures and tested them under uniaxial and biaxial loads to evaluate their expansion potentials. The finite element model and testing of the auxetic skin graft using an isotropic and elastic material to represent skin demonstrated a high expansion and skin cover.</p><p>F. Tsegay et al., 2023 [<xref ref-type="bibr" rid="scirp.123888-ref12">12</xref>] presented an auxetic hydrogel skin pH indicator wound dressing as a smart band-aid or dressing. Using a phenol red dye in the hydrogel matrix of the material could help monitor pH changes in the vicinity of the wound to better indicate what treatment is required for the patient.</p><p>As mentioned before, a large constraint to auxetic unit cell design is the high stress zones of the structure, which limits the use cases for these structures, especially when manufactured from biomaterials. It is possible that auxetic biomaterials can be further optimized, which would involve exploring composite materials such as nano-size particles. However, it is beyond the scope of this paper.</p></sec></sec><sec id="s3"><title>3. Conclusion</title><p>Several biomedical applications can implement the use of auxetics; however, challenges arise from unit cell design, manufacturing, FEA simulation and more. Variations in unit cell designs and manufacturing methods can result in different auxetic properties and even in different bulk mechanical properties. FEA computer simulation can also be challenging when working with auxetics, as several research papers have reported that the auxetic behavior agrees with the simulation but fails to theoretically predict the mechanical properties values. Numerous studies have found that auxetics can be more suitable in certain biomedical applications using FEA and analytical solutions, but further experimental and clinical research is needed before replacing the current non-auxetics biomaterials.</p></sec><sec id="s4"><title>Acknowledgements</title><p>The authors would like to acknowledge the support from the Department of Systems Design Engineering and the Department of Mechanical and Mechatronics Engineering at the University of Waterloo.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s6"><title>Cite this paper</title><p>Rose, S., Siu, D., Zhu, JD and Roufail, R. (2023) Auxetics in Biomedical Applications: A Review. Journal of Minerals and Materials Characterization and Engineering, 11, 27-35. https://doi.org/10.4236/jmmce.2023.112003</p></sec></body><back><ref-list><title>References</title><ref id="scirp.123888-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Sanami, M., Ravirala, N., Alderson, K. and Alderson A. (2014) Auxetic Materials for Sports Applications. Procedia Engineering, 72, 453-458. https://doi.org/10.1016/j.proeng.2014.06.079</mixed-citation></ref><ref id="scirp.123888-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Saxena, K.K., Das, R. and Calius, E.P. (2016) Three Decades of Auxetics Research—Materials with Negative Poisson’s Ratio: A Review. Advanced Engineering Materials, 18, 1847-1870.https://doi.org/10.1002/adem.201600053</mixed-citation></ref><ref id="scirp.123888-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Pothier, P. Roufail, R. Malton, M. (2022) Unit Cell Modelling of Auxetic Structure. Journal of Minerals and Materials Characterization and Engineering, 10, 360-369. https://doi.org/10.4236/jmmce.2022.104025</mixed-citation></ref><ref id="scirp.123888-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Meena, K. and Singamneni, S. (2019) A New Auxetic Structure with Significantly Reduced Stress Concentration Effects. Materials &amp; Design, 173, Article ID: 107779. https://doi.org/10.1016/j.matdes.2019.107779</mixed-citation></ref><ref id="scirp.123888-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Mir, M., Ali, M.N., Sami, J. and Ansari, U. (2014) Review of Mechanics and Applications of Auxetic Structures. Advances in Materials Science and Engineering, 2014, Article ID: 753496. https://doi.org/10.1155/2014/753496</mixed-citation></ref><ref id="scirp.123888-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, Y., Luo, Y., Gao, D., Yu, C., Ren, X. and Zhang, C. (2022) In-Plane Elastic Properties of a Novel Re-Entrant Auxetic Honeycomb with Zigzag Inclined Ligaments. Engineering Structures, 268, Article ID: 114788. https://doi.org/10.1016/j.engstruct.2022.114788</mixed-citation></ref><ref id="scirp.123888-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Kapnisi, M., Mansfield, C., Marijon, C., Guex, A.G., Perbellini, F., Bardi, I., Humphrey, E.J., Puetzer, J.L., Mawad, D., Koutsogeorgis, D.C., Stuckey, D.J., Terracciano, C.M., Harding, S.E. and Stevens, M.M. (2018) Auxetic Cardiac Patches with Tunable Mechanical and Conductive Properties toward Treating Myocardial Infarction. Advanced Functional Materials, 28, Article ID: 1800618. https://doi.org/10.1002/adfm.201800618</mixed-citation></ref><ref id="scirp.123888-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Ali, M.N., Busfield, J.J.C. and Rehman, I.U. (2014) Auxetic Oesophageal Stents: Structure and Mechanical Properties. Journal of Materials Science: Materials in Medicine, 25, 527-553. https://doi.org/10.1007/s10856-013-5067-2</mixed-citation></ref><ref id="scirp.123888-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Leung, M.S., Yick, K., Sun, Y., Chow, L. and Ng. S. (2022) 3D Printed Auxetic Heel Pads for Patients with Diabetic Mellitus. Computers in Biology and Medicine, 146, Article ID: 105582. https://doi.org/10.1016/j.compbiomed.2022.105582</mixed-citation></ref><ref id="scirp.123888-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Warner, J.J., Gillies, A.R., Hwang, H.H., Zhang, H., Lieber, R.L. and Chen, S. (2017) 3D-Printed Biomaterials with Regional Auxetic Properties. Journal of the Mechanical Behavior of Biomedical Materials, 76, 145-152. https://doi.org/10.1016/j.jmbbm.2017.05.016</mixed-citation></ref><ref id="scirp.123888-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Mardling, P., Alderson, A., Jordan-Mahy, N. and Le Maitre, C.L. (2020) The Use of Auxetic Materials in Tissue Engineering. Biomaterials Science, 8, 2074-2083. https://doi.org/10.1039/C9BM01928F</mixed-citation></ref><ref id="scirp.123888-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Tsegay, F., Hisham, M., Elsherif, M., Schiffer, A. and Butt, H. (2023) 3D Printing of pH Indicator Auxetic Hydrogel Skin Wound Dressing. Molecules, 28, Article 1339. https://doi.org/10.3390/molecules28031339</mixed-citation></ref><ref id="scirp.123888-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Kopecek, J. (2007). Hydrogel Biomaterials: A Smart Future? Biomaterials, 28, 5185-5192. https://doi.org/10.1016/j.biomaterials.2007.07.044</mixed-citation></ref><ref id="scirp.123888-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Masters, I.G. and Evans, K.E. (1996) Models for the Elastic Deformation of Honeycombs. Composite Structures, 35, 403-422. https://doi.org/10.1016/S0263-8223(96)00054-2</mixed-citation></ref><ref id="scirp.123888-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Ajdary, R., Abidnejad, R., Lehtonen, J., Kuula, J., Raussi-Lehto, E., Kankuri, E., Tardy, B. and Rojas, O.J. (2022) Bacterial Nanocellulose Enables Auxetic Supporting Implants. Carbohydrate Polymers, 284, Article ID: 119198. https://doi.org/10.1016/j.carbpol.2022.119198</mixed-citation></ref><ref id="scirp.123888-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Ali, M.N. and Rehman, I.U. (2015) Auxetic Polyurethane Stents and Stent-Grafts for the Palliative Treatment of Squamous Cell Carcinomas of the Proximal and Mid Oesophagus: A Novel Fabrication Route. Journal of Manufacturing Systems, 37, 375-395. https://doi.org/10.1016/j.jmsy.2014.07.009</mixed-citation></ref><ref id="scirp.123888-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Yao, Y., Wang, L., Li, J., Tian, S., Zhang, M. and Fan, Y. (2020) A Novel Auxetic Structure Based Bone Screw Design: Tensile Mechanical Characterization and Pullout Fixation Strength Evaluation. Materials and Design, 188, Article ID: 108424. https://doi.org/10.1016/j.matdes.2019.108424</mixed-citation></ref><ref id="scirp.123888-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Ghavidelnia, N., Bodaghi, M. and Hedayati, R. (2021) Femur Auxetic Meta-Implants with Tuned Micromotion Distribution. Materials, 14, Article 114. https://doi.org/10.3390/ma14010114</mixed-citation></ref><ref id="scirp.123888-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Yao, Y., Yuan, H., Huang, H., Liu, J., Wang, L. and Fan, Y. (2021) Biomechanical Design and Analysis of Auxetic Pedicle Screw to Resist Loosening. Computers in Biology and Medicine, 133, Article ID: 104386. https://doi.org/10.1016/j.compbiomed.2021.104386</mixed-citation></ref><ref id="scirp.123888-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Bonfanti, A. and Bhaskar, A. (2019) Elastic Stabilization of Wrinkles in Thin Films by Auxetic Microstructure. Extreme Mechanics Letters, 33, Article ID: 100556. https://doi.org/10.1016/j.eml.2019.100556</mixed-citation></ref><ref id="scirp.123888-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Arjunan, A., Zahid, S., Baroutaji, A. and Robinson, J. (2021) 3D Printed Auxetic Nasopharyngeal Swabs for COVID-19 Sample Collection. Journal of the Mechanical Behavior of Biomedical Materials, 114, Article ID: 104175. https://doi.org/10.1016/j.jmbbm.2020.104175</mixed-citation></ref><ref id="scirp.123888-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Gupta, V. and Chanda, A. (2023) Expansion Potential of Novel Skin Grafts Simulants with I-Shaped Auxetic Incisions. Biomedical Engineering Advances, 5, Article ID: 100071. https://doi.org/10.1016/j.bea.2023.100071</mixed-citation></ref></ref-list></back></article>