<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JMMCE</journal-id><journal-title-group><journal-title>Journal of Minerals and Materials Characterization and Engineering</journal-title></journal-title-group><issn pub-type="epub">2327-4077</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jmmce.2022.105032</article-id><article-id pub-id-type="publisher-id">JMMCE-120152</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Comparative Characteristics of Hydrated Lime with Fine Sewage Sludge Ash (FSSA) and Coal Fly Ash (CFA)
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mamoudou</surname><given-names>Sall</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Abdou</surname><given-names>Ciss Wade</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gora</surname><given-names>Dieye</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Alassane</surname><given-names>Traoré</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Prince</surname><given-names>Momar Gueye</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Prince</surname><given-names>Momar Gueye</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Saliou</surname><given-names>Diouf</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Déthié</surname><given-names>Thiaw</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Khalifa</surname><given-names>Ababacar Diop</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Djibril</surname><given-names>Diop</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Institute of Applied Nuclear Technology, Department of Physics, Faculty of Sciences and Techniques, University of Cheikh Anta Diop, Dakar, Senegal</addr-line></aff><aff id="aff3"><addr-line>Laboratory of Civil Engineering Materials, High Polytechnic School, University of Cheikh Anta Diop, Dakar, Senegal</addr-line></aff><aff id="aff1"><addr-line>Laboratory of X-Ray, Department of Physic, Faculty of Sciences and Techniques, University of Cheikh Anta Diop, Dakar, Senegal</addr-line></aff><pub-date pub-type="epub"><day>30</day><month>08</month><year>2022</year></pub-date><volume>10</volume><issue>05</issue><fpage>446</fpage><lpage>459</lpage><history><date date-type="received"><day>14,</day>	<month>August</month>	<year>2022</year></date><date date-type="rev-recd"><day>26,</day>	<month>September</month>	<year>2022</year>	</date><date date-type="accepted"><day>29,</day>	<month>September</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The disposal of waste has become an environmental issue due to the limited available landfilling space. This paper aims to compare the characteristics of hydrated lime with fine sewage sludge ash (FSSA) and coal fly ash (CFA). Multiple techniques, X-ray fluorescence (XRF), X-ray diffraction (XRD), the Fourier transform infrared (FTIR), compressive strengths, thermophysical properties, and setting time were used to assess the physicochemical characteristics of the lime-based materials. X-ray fluorescence and X-ray diffraction were used to determine the chemical composition and phases of ashes, lime and binders. The results showed that the chemical composition of ashes is similar to that of cement. Besides glass, the main minerals identified in CFA and FSSA are quartz (SiO
  <sub>2</sub>) and anhydrite (CaSO
  <sub>4</sub>). Moreover, calcium aluminium oxide (Ca
  <sub>3</sub>Al
  <sub>2</sub>O
  <sub>6</sub>) was detected for CFA and phosphorus calcium silicate (Ca
  <sub>2</sub>SiO
  <sub>4</sub>-Ca
  <sub>3</sub>(PO
  <sub>4</sub>)
  <sub>2</sub>) for FSSA and minor phases were detected for both. FTIR measurements were carried out to characterize the inorganics components of different samples. Compressive strengths of mortars with different formulations have shown that both have a long-term positive effect which might be related to a pozzolanic activity. For the CFA the L
  <sub>3</sub> binder consisting of 60% of coal fly ash and 40% lime has a higher compressive strength than the others while for the FSSA the L
  <sub>4</sub> binder consisting of 80% fine ash and 20% lime has a higher compressive strength than the others. Both binders setting start times are greater than that of cement but shorter than that of lime. The study of the thermophysical properties of binders shows that they have a higher thermal resistance than cement mortar. Moreover, binders heat up less quickly because of their low effusivity compared to cement. Lime-based materials system could be a promising option to both relieve the waste disposal pressure and provide a potential sustainable construction material.
 
</p></abstract><kwd-group><kwd>Coal Fly Ash</kwd><kwd> Fine Sewage Sludge Ash</kwd><kwd> Lime</kwd><kwd> Binder</kwd><kwd> Microstructure</kwd><kwd> Thermomechanical Behavior</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Since ancient times lime-based materials have been widely studied and applied in construction. Specifically, the lime-volcanic ash mortars were first applied as a wall covering on Santorini Island in 1500 BC [<xref ref-type="bibr" rid="scirp.120152-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref2">2</xref>].</p><p>Lime together with volcanic ash and crushed sintered clay products in concrete were used by the Romans for the construction of buildings and coastal works, which had resisted erosion from seawater for over 20 centuries [<xref ref-type="bibr" rid="scirp.120152-ref3">3</xref>]. However, the invention of Portland cement (PC) in the 19th century caused a recession in the use of lime-binders. Contribution to climate change by greenhouse gases (GHG) emissions in the atmosphere (CO<sub>2</sub> in particular) which are around 7% from cement manufacturing is partly responsible for global warming [<xref ref-type="bibr" rid="scirp.120152-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref8">8</xref>]. Environmentally friendly cement-based materials are a topic of interest and cement replacement materials play an important role in the construction industry considering economical, technological and ecological points of view [<xref ref-type="bibr" rid="scirp.120152-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref11">11</xref>].</p><p>Then lime-based materials have again become popular as alternatives to PC recently due to the high cost, carbon footprint and energy intensity of PC. In addition, concrete based on PC would normally suffer from long-term degradation problems, especially under harsh conditions [<xref ref-type="bibr" rid="scirp.120152-ref3">3</xref>]. More importantly, the application of PC-based materials in repairing ancient buildings is not allowed according to the requirements regulated by European supervisory authorities which specify that the repairing materials should be compatible with the original materials [<xref ref-type="bibr" rid="scirp.120152-ref1">1</xref>].</p><p>Wastes are commonly used as partial replacements for PC, as they are not only cost-effective, but also improve some properties of the produced mortars and concrete. Their role in the lime-based materials is their participation in pozzolanic reactions with calcium hydroxide to form hydration products, which are similar to those produced from PC hydration including calcium silicate hydrates (CSH) and calcium aluminate silicate hydrates (CASH) [<xref ref-type="bibr" rid="scirp.120152-ref12">12</xref>].</p><p>Coal fly ash is considered as an industrial by-product derived from coal combustion in thermal power plants while the FSSA is derived from the sludge dewatered, dried and burnt in a fluidized bed incinerator. Their improper disposal has become an environmental concern and resulted in a waste of recoverable resources.</p><p>Then the main application fields of these ashes are currently attributed to construction, ceramic, environmental, landfills and agricultural sectors. According to statistics, industrialized countries such as the US and EU mostly use the fly ash in concrete and cement production, waste stabilization, mining applications, as structural fills and embankments, for remediation and restoration that overall accounts for more than 60% - 70% of all Coal Fly Ash [<xref ref-type="bibr" rid="scirp.120152-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref13">13</xref>]. Sludge ash is also very interesting for many applications because it can be mixed with cement or binders such as lime to give rise to new materials with several attractive physical characteristics such as the increase in resilience, and the long-term strength of mortars [<xref ref-type="bibr" rid="scirp.120152-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref16">16</xref>]. In fact, new environmental challenges and research opportunities arise on the use of these solid wastes as well as their basic properties.</p><p>So the use of such waste materials allows decrease energy consumption, preserves non-renewable natural resources, and reduces the high amount of material that goes to landfills. Mineral additions are defined as inorganic materials, pozzolanic materials or latent hydraulic materials that finely divided can be added to concrete and/or to Portland cement-based mortars, to improve some of their properties or confer special characteristics [<xref ref-type="bibr" rid="scirp.120152-ref17">17</xref>]. The large amounts of solid waste produced can be recovered and used as building materials [<xref ref-type="bibr" rid="scirp.120152-ref14">14</xref>] - [<xref ref-type="bibr" rid="scirp.120152-ref21">21</xref>].</p><p>To better understand the characteristics between hydrated lime and FSSA or CFA we also used a comparison between these samples.</p><p>Then this paper focuses on a comparative study of using coal fly ash (CFA) and fine sewage sludge ash (FSSA) as an additive to hydrated lime, to develop a new type of binder. The physical, chemical and thermomechanical properties of the systems were also compared. Multiple techniques including X-ray fluorescence (XRF) and X-ray diffraction (XRD) were used to assess the chemical composition and mineralogical characterization of samples. The FTIR, the density, the standardized consistency tests, the setting time, the compression tests and the thermal properties of ashes were also investigated.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>Two types of ash CFA and FSSA mixed with hydrated lime were used as binding materials. The FSSA was collected from the Senegalese sewage treatment plant of Camberene located in the Dakar region while for the CFA comes from the thermal power of the Chemical Industries of Senegal in the Thies region. Both are fine grey powder and CFA is the principal by-product generated during the coal combustion process while for the FSSA, sludge is dewatered, dried and burnt in a fluidized bed incinerator at 850˚C. The FSSA particles were porous with a relatively rough surface while the CFA particles were largely spherical in shape [<xref ref-type="bibr" rid="scirp.120152-ref22">22</xref>]. They have approximately the same absolute density of 2.4 g&#183;cm<sup>−3</sup>. The lime was commercially available from local suppliers and its absolute density is in the range 2.6 to 2.9 g&#183;cm<sup>−3</sup>.</p><p>A portable X-ray fluorescence (P-XRF) device Niton XLT900s was used to analyze the chemical composition of the ashes in terms of major and minor elements with a measurement time of 350 s. XRF was performed with 100% normalization and full fundamental parameter quantification techniques [<xref ref-type="bibr" rid="scirp.120152-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref26">26</xref>]. The mineralogical characterization of ashes and mixtures lime-ash-water was carried out by X-ray powder diffraction (XRD) using a PW1840 diffractometer with Cu Kα radiation operating at 30 mA and 40 kV. The analysis was done in the continuous scanning mode with a speed of 0.05˚ per s within the range of 10˚ ≤ 2θ ≤ 70˚ and acquisition time of 1560 s. The diffractometer is linked to a computer equipped with APD software. For data processing we used X Pert High Score software [<xref ref-type="bibr" rid="scirp.120152-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref26">26</xref>]. The Fourier transform infrared FTIR measurements were carried out by spectrometer Perkin Elmer FTIR System Spectrum X in the range 400 - 4000 cm<sup>−</sup><sup>1</sup>.</p><p>For the setting time, the Vicat apparatus (NF EN 196-3) was used. The powder was dry mixed for one minute at a low speed by a standard mechanical drum mixer before adding water, and then another three minutes of mixing (1 min at low speed, 2 mins at high speed) was carried out to obtain the homogenous pastes. After mixing, the fresh mixture was cast into prisms steel moulds with a size of 4 &#215; 4 &#215; 16 cm and then subjected to vibration for about one minute to remove entrapped air in the samples. Compressive strength was then investigated after hydration times: 3, 7, 28 days and each value is the average of 6 tests (NF EN 196-1). All thermophysical experiments were performed using samples prepared in a mould of dimensions of 10 cm &#215; 10 cm &#215; 2 cm for the thermal test. Then the thermal conductivity and effusivity of samples were determined simultaneously using a transient method [<xref ref-type="bibr" rid="scirp.120152-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref27">27</xref>].</p></sec><sec id="s3"><title>3. Results and Discussion</title><p>The chemical compositions of FSSA and CFA determined by using a portable X-ray fluorescence (P-XRF) device Niton XLT900s, are shown in <xref ref-type="table" rid="table1">Table 1</xref>. The major constituents of FSSA are SiO<sub>2</sub>, Al<sub>2</sub>O<sub>3</sub>, CaO, Fe<sub>2</sub>O<sub>3</sub> and P<sub>2</sub>O<sub>5</sub> and the FA is mainly consisted of SiO<sub>2</sub>, Fe<sub>2</sub>O<sub>3</sub> and Al<sub>2</sub>O<sub>3</sub>.</p><p>We find that concentrations of SiO<sub>2</sub>, TiO<sub>2</sub>, and Al<sub>2</sub>O<sub>3</sub> are higher in CFA. The amount of CaO and P<sub>2</sub>O<sub>5</sub> is high in FSSA compared to CFA and others minerals admixtures. These minerals are combined to form a calcium phosphate mineral weakly soluble in a basic environment [<xref ref-type="bibr" rid="scirp.120152-ref19">19</xref>]. It is known that the occurrence of phosphorus affects the setting time [<xref ref-type="bibr" rid="scirp.120152-ref28">28</xref>]. As shown in <xref ref-type="table" rid="table1">Table 1</xref> the amount of Mg is 3.90% in FSSA while no Mg has been identified in the CFA or their concentration was below the detection level. The concentration of CaO in FSSA is instead 4.7 times higher than that in CFA while for SiO<sub>2</sub> the concentration is 2.2 times in CFA compared to FSSA. For the Al<sub>2</sub>O<sub>3</sub> the concentration in the former is instead 1.8 times higher than that in the latter. The chemical composition of FSSA and CFA is closer to that of cement produced by industries in Senegal having the following chemical composition: SiO<sub>2</sub> (19.53), Al<sub>2</sub>O<sub>3</sub> (7.12), Fe<sub>2</sub>O<sub>3</sub> (2.22), and CaO (65.5) [<xref ref-type="bibr" rid="scirp.120152-ref29">29</xref>]. These oxides SiO<sub>2</sub>, Al<sub>2</sub>O<sub>3</sub> and Fe<sub>2</sub>O<sub>3</sub> compose the reactive part of pozzolanic materials [<xref ref-type="bibr" rid="scirp.120152-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref31">31</xref>]. In the CFA the sum of SiO<sub>2</sub>, Al<sub>2</sub>O<sub>3</sub> and Fe<sub>2</sub>O<sub>3</sub> represent more than 70% so this fly ash is in Class F Fly ashes based on the</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Results of major (%) and minor (mg/kg) elements using XRF technique of sewage sludge ash contents</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Elements</th><th align="center" valign="middle" >FSSA</th><th align="center" valign="middle" >CFA</th></tr></thead><tr><td align="center" valign="middle" >SiO<sub>2</sub></td><td align="center" valign="middle" >24.1%</td><td align="center" valign="middle" >52.1 wt%</td></tr><tr><td align="center" valign="middle" >Al<sub>2</sub>O<sub>3</sub></td><td align="center" valign="middle" >6.69%</td><td align="center" valign="middle" >11.8 wt%</td></tr><tr><td align="center" valign="middle" >Fe<sub>2</sub>O<sub>3</sub></td><td align="center" valign="middle" >12.6%</td><td align="center" valign="middle" >7.59 wt%</td></tr><tr><td align="center" valign="middle" >CaO</td><td align="center" valign="middle" >22.2%</td><td align="center" valign="middle" >4.68 wt%</td></tr><tr><td align="center" valign="middle" >MgO</td><td align="center" valign="middle" >3.90%</td><td align="center" valign="middle" >LOD</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>O</td><td align="center" valign="middle" >3.22%</td><td align="center" valign="middle" >1.72 wt%</td></tr><tr><td align="center" valign="middle" >TiO<sub>2</sub></td><td align="center" valign="middle" >0.66%</td><td align="center" valign="middle" >1.52 wt%</td></tr><tr><td align="center" valign="middle" >MnO</td><td align="center" valign="middle" >0.10%</td><td align="center" valign="middle" >0.05 wt%</td></tr><tr><td align="center" valign="middle" >P<sub>2</sub>O<sub>5</sub></td><td align="center" valign="middle" >5.92%</td><td align="center" valign="middle" >1.15 wt%</td></tr><tr><td align="center" valign="middle" >Pb</td><td align="center" valign="middle" >357 ppm</td><td align="center" valign="middle" >29 ppm</td></tr><tr><td align="center" valign="middle" >Cu</td><td align="center" valign="middle" >1264 ppm</td><td align="center" valign="middle" >47 ppm</td></tr><tr><td align="center" valign="middle" >Cr</td><td align="center" valign="middle" >212 ppm</td><td align="center" valign="middle" >157 ppm</td></tr><tr><td align="center" valign="middle" >Zn</td><td align="center" valign="middle" >3632 ppm</td><td align="center" valign="middle" >54 ppm</td></tr><tr><td align="center" valign="middle" >As</td><td align="center" valign="middle" >16 ppm</td><td align="center" valign="middle" >25 ppm</td></tr></tbody></table></table-wrap><p>standard classification [<xref ref-type="bibr" rid="scirp.120152-ref32">32</xref>]. So both may be used in civil engineering. As for heavy metals they are more important in FSSA than CFA except for the As. For example, the concentration of Pb is about twelve times higher in FSSA than in CFA, while that of Zn is 67.2 times greater in the former than that of Zn in the latter.</p><sec id="s3_1"><title>3.1. Mineralogical Characterization</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows the diffractogram of lime. The phases identified in lime are portlandite and calcite. Portlandite comes from the slaking of lime. The presence of calcite could be due to the carbonation of porlandite due to its exposure to air. The carbonation of lime is due to the reaction of two compounds: 1) CO<sub>2</sub> from the atmosphere, and 2) calcium hydroxide (Ca(OH)<sub>2</sub>). First, CO<sub>2</sub> dissolves in the water of the pores forming carbonate ions. Then, these carbonate ions can react with the Ca ions of the pore solution leading to calcium carbonate (CaCO<sub>3</sub>) precipitation. The CaCO<sub>3</sub> coming from the carbonation of other hydration products and/or anhydrous silicates and aluminates phases [<xref ref-type="bibr" rid="scirp.120152-ref8">8</xref>].</p><p>Diffractograms of FSSA (<xref ref-type="fig" rid="fig2">Figure 2</xref>) and CFA (<xref ref-type="fig" rid="fig3">Figure 3</xref>) show the existence of a complex polyphasic material composed of several crystalline phases and a glass phase [<xref ref-type="bibr" rid="scirp.120152-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref26">26</xref>].</p><p>Besides glass, the main minerals identified in these ashes are quartz (SiO<sub>2</sub>), and anhydrite (CaSO<sub>4</sub>) but in CFA we detected calcium aluminiumoxide (Ca<sub>3</sub>Al<sub>2</sub>O<sub>6</sub>) while for the FSSA a phosphorus calcium silicate (Ca<sub>2</sub>SiO<sub>4</sub>-Ca<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>) was found and minor phases (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><p>Both have a high background due to the amorphous phase. Then elements in the amorphous phase can react with lime and produce new phases. The intensity of the peaks of FSSA is low compared to CFA because the crystallinity of the fine sewage sludge ash is weak [<xref ref-type="bibr" rid="scirp.120152-ref33">33</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref34">34</xref>].</p><p>Gypsum, hydrated anhydrite is a mineral added to the clinker to form cement Portland. It is used as a retardant in Portland cement clinker. It reacts with calcium aluminates to regulate the setting by forming ettringite (Ca<sub>6</sub>Al<sub>2</sub>(SO<sub>4</sub>)<sub>3</sub> (OH)<sub>12</sub>&#183;26H<sub>2</sub>O). Its presence in the ashes is beneficial because we have more need to add it to form a binder based on ash and hydrated lime. Calcium reacted with aluminum and silica to form new phases of hydrated aluminum and aluminum silica like Gehlenite and Calcium Silicate Hydrate for certain formulations (<xref ref-type="fig" rid="fig4">Figure 4</xref> and <xref ref-type="fig" rid="fig5">Figure 5</xref>). Aluminum and silica came probably from the partial decomposition of the vitreous phases of ashes. In the presence of hydrated lime, phosphate can cause precipitation of the poorly soluble calcium phosphate on the surface of cement grains. The compounds form a fine crystalline and poorly permeable layer, which limit the hydration process. Hence poorly soluble phosphate can crystallize in the pores of the paste [<xref ref-type="bibr" rid="scirp.120152-ref28">28</xref>].</p><p>The hydration reaction allows the transformation of the binder paste from the liquid state to the solid state. The hydration mechanisms occur simultaneously and it is a complex process in which the main binder compounds react to form new insoluble compounds which cause the material to set and gradually harden. Thus these results show the reactivity of the ash in the presence of lime, which mechanically results in the hardening of the paste figure.</p></sec><sec id="s3_2"><title>3.2. FTIR Results</title><p>Results of FTIR show that these materials tend to report small bands located between 600 and 650 cm<sup>−1</sup> and bands between 790 and 800 cm<sup>−1</sup>, which are attributed to the bonds present in the fly ash source (quartz and mullite) [<xref ref-type="bibr" rid="scirp.120152-ref35">35</xref>] (<xref ref-type="fig" rid="fig6">Figure 6</xref>). In both ashes, SiO<sub>2</sub> (quartz) was identified by the absorption bands at 773 cm<sup>−1</sup> and 788 cm<sup>−1</sup> while for the pure SiO<sub>2</sub> the absorption bands were found at 797 and 778 cm<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.120152-ref36">36</xref>]. In the reference [<xref ref-type="bibr" rid="scirp.120152-ref37">37</xref>] the absorption bands of silica appear at 785 cm<sup>−1</sup>. Tantawy et al. showed that incineration of sewage sludge at 800˚C leads to a decrease in the intensity of the absorption bands of silica. So this is an indication of increasing the degree of polymerization of silica network as a result of the crystallization of silica into quartz. Bands observed around 3200 and 1601 cm<sup>−1</sup> are due to vibrations of hydroxyl groups.</p><p>The absorption bands at 1027, 1103 and 1129 cm<sup>−1</sup> in FSSA (<xref ref-type="fig" rid="fig7">Figure 7</xref>) show the P-O stretching region and this could identify the Ca<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub> found in XRD results of FSSA [<xref ref-type="bibr" rid="scirp.120152-ref36">36</xref>].</p><p>The absorption band of P-containing compounds appears at 567 cm<sup>−</sup><sup>1</sup> due to P-O bending vibration [<xref ref-type="bibr" rid="scirp.120152-ref37">37</xref>] [<xref ref-type="bibr" rid="scirp.120152-ref38">38</xref>]. In FSSA (<xref ref-type="fig" rid="fig7">Figure 7</xref>) this absorption band appears at 557 cm<sup>−</sup><sup>1</sup>. Anhydride CaSO<sub>4</sub> could be responsible for the absorption band at 1131 cm<sup>−1</sup>. A shoulder at 875 accompanied by a low intensity band at 1459 is characteristic of C-O bond stretching vibration modes. These absorption bands highlight the presence of calcium carbonate which could come from a slight carbonation of these ashes [<xref ref-type="bibr" rid="scirp.120152-ref39">39</xref>]. This also suggests that in the minor phases of CFA diffraction there is calcium carbonate. In [<xref ref-type="bibr" rid="scirp.120152-ref37">37</xref>], the absorption band of carbonate appears at 1442 cm<sup>−</sup><sup>1</sup>. These results are in good agreement with XRD results.</p></sec><sec id="s3_3"><title>3.3. Thermomechanical Behaviour</title><p>These results show that mortar containing 60% of coal fly ash and 40% of lime L<sub>3</sub>CFA has the greatest resistance at 28 days while the L<sub>4</sub>FSSA mortar containing 80% of FSSA and 20% lime has the greatest resistance at 3 days. Furthermore, at seven days, the resistance of the two binders is in the same order (<xref ref-type="fig" rid="fig8">Figure 8</xref>).</p><p>We find that the thermal conductivity of mortars made from ashes and lime is lower than that of mortar made from cement (<xref ref-type="table" rid="table2">Table 2</xref>). This shows that the ashes and lime mortars have a higher thermal resistance than the cement mortar. This is very important in the sense it helps in reducing the heat exchange between the internal and external parts of the buildings.</p><p>Also, the thermal effusively value of lime and ashes mortars is lower than that of the cement mortar. Thus, lime and ashes-based mortar absorb heat less quickly than cement mortar. These mortars when used in the construction industry will develop better thermal insulation properties than the latter. Mortar from FSSA and lime has better thermal insulation properties than the Mortar from CFA and lime.</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Comparison of thermo physical properties</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Mortar</th><th align="center" valign="middle" >Average thermal conductivity (W/m&#183;˚K)</th><th align="center" valign="middle" >Average thermal effusivity (J/m<sup>2</sup>&#183;S&#183;˚K)</th></tr></thead><tr><td align="center" valign="middle" >Based on lime and FSSA (Present work)</td><td align="center" valign="middle" >0.33</td><td align="center" valign="middle" >680.05</td></tr><tr><td align="center" valign="middle" >Cement based mortar [<xref ref-type="bibr" rid="scirp.120152-ref40">40</xref>]</td><td align="center" valign="middle" >1.40</td><td align="center" valign="middle" >1754. 99</td></tr><tr><td align="center" valign="middle" >Clay-based mortar [<xref ref-type="bibr" rid="scirp.120152-ref41">41</xref>]</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >705</td></tr><tr><td align="center" valign="middle" >Based on lime and CFA (Present work)</td><td align="center" valign="middle" >0.720</td><td align="center" valign="middle" >944.9</td></tr></tbody></table></table-wrap></sec><sec id="s3_4"><title>3.4. Toxicological Risk</title><p>The possible dangerousness of the ash depends essentially on its heavy metal content concerning the limits of regulated hazardous substances on one hand, and on the other hand of the overall ecotoxicity of the ash (criterion H14 of Directive 91/689/EEC).</p><p>In this Directive the material is toxic if its content in heavy metal is higher to some thresholds as defined in Annex III (<xref ref-type="table" rid="table3">Table 3</xref>).</p><p>Except for the Cr, all the heavy metal contents of the CFA are below the threshold concentration in <xref ref-type="table" rid="table3">Table 3</xref>, while for the FSSA two heavy metals As and Pb are below the threshold concentration. So these ashes cannot therefore be a priori considered dangerous on the basis of these criteria. The classification of ashes can vary according to the criteria used, depending on the geographic location as well. However, some researchers differ on the definition of toxicity of ashes. Some will put them in landfill if there are considered dangerous while others who consider them non-dangerous will value them [<xref ref-type="bibr" rid="scirp.120152-ref42">42</xref>]. Thus a study of the dangerousness of the ash is necessary to see their possible compatibility with the recovery in construction.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Comparison of the concentration of minor elements in ashes with thresholds defined in Annex-III</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Element</th><th align="center" valign="middle" >Concentration (mg/kg) CFA</th><th align="center" valign="middle" >concentration (mg/kg) FSSA</th><th align="center" valign="middle" >Threshold concentration (mg/kg)</th></tr></thead><tr><td align="center" valign="middle" >As</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >220</td></tr><tr><td align="center" valign="middle" >Cr</td><td align="center" valign="middle" >157</td><td align="center" valign="middle" >212</td><td align="center" valign="middle" >150</td></tr><tr><td align="center" valign="middle" >Cu</td><td align="center" valign="middle" >47</td><td align="center" valign="middle" >1264</td><td align="center" valign="middle" >340</td></tr><tr><td align="center" valign="middle" >Pb</td><td align="center" valign="middle" >29</td><td align="center" valign="middle" >357</td><td align="center" valign="middle" >840</td></tr></tbody></table></table-wrap></sec></sec><sec id="s4"><title>4. Conclusion</title><p>A comparative study between the physico-chemical characteristics of binders based on CFA, FSSA and lime in order to develop an eco-cement was investigated. The following conclusions were derived:</p><p> The chemical composition of ashes is similar to that of cement and the coal fly ash is in Class F.</p><p> The main phases identified on lime are portlandite and calcite while in the coal fly ash quartz (SiO<sub>2</sub>), anhydrite (CaSO<sub>4</sub>), calcium aluminium oxide (Ca<sub>3</sub>Al<sub>2</sub>O<sub>6</sub>) and minor phases were found.</p><p> Binder L<sub>3</sub> formed from 60% fly ash and 40% lime gave the best compressive strength at 28 days than L<sub>4</sub> mortar containing 80% of FSSA and 20% of lime.</p><p> Mortar from FSSA and lime have better thermal insulation properties than the Mortar from CFA and lime and these mortars when used in the construction industry will therefore present better thermal insulation properties than the cement-based materials.</p><p> The results of FTIR are in good agreement with XRD results.</p><p> As perspective, other basic knowledge about dimensional stability, water demand, morphology, use of setting accelerators and leaching of heavy metals should be investigated.</p></sec><sec id="s5"><title>Acknowledgements</title><p>We acknowledge the Laboratory of Civil Engineering Materials, High Polytechnic School, University of Cheikh Anta Diop, Dakar, Senegal for the technical assistance with the thermomechanical measurements, as well as the Institute of Applied Nuclear Technology, Department of Physics, Faculty of Sciences and Techniques, University of Cheikh Anta Diop, Dakar, Senegal for helping with the XRF.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Sall, M., Wade, A.C., Dieye, G., Traor&#233;, A., Gueye, P.M., Diouf, S., Thiaw, D., Diop, K.A. and Diop, D. (2022) Comparative Characteristics of Hydrated Lime with Fine Sewage Sludge Ash (FSSA) and Coal Fly Ash (CFA). Journal of Minerals and Materials Characterization and Engineering, 10, 446-459. https://doi.org/10.4236/jmmce.2022.105032</p></sec></body><back><ref-list><title>References</title><ref id="scirp.120152-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Yao, Z., Ji, X., Sarker, P., Tang, J., Ge, L., Xia, M. and Xi, Y. (2014) A Comprehensive Review on the Applications of Coal Fly Ash. Earth Science Reviews, 141, 105-121. https://doi.org/10.1016/j.earscirev.2014.11.016</mixed-citation></ref><ref id="scirp.120152-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Grist, E., Paine, K., Heath, A., Norman, J. and Pinder, H. (2013) Compressive Strength Development of Binary and Ternary Lime-Pozzolan Mortars. Materials &amp; Design (1980-2015), 52, 514-523. https://doi.org/10.1016/j.matdes.2013.05.006</mixed-citation></ref><ref id="scirp.120152-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Witze, A. (2017) Seawater Is the Secret to Long-Lasting Roman Concrete. Nature. https://doi.org/10.1038/nature.2017.22231</mixed-citation></ref><ref id="scirp.120152-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Hendriks, C., Worrell, E., De Jager, D., Blok, K. and Riemer, P. (1998) Emission Reduction of Greenhouse Gases from the Cement Industry. Proceedings of the 4th International Conference on Greenhouse Gas Control Technologies, Interlaken, 30 August-2 September 1998, 939-944. https://doi.org/10.1016/B978-008043018-8/50150-8</mixed-citation></ref><ref id="scirp.120152-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Meyer, C. (2009) The Greening of the Concrete Industry. Cement and Concrete Composites, 31, 601-605. https://doi.org/10.1016/j.cemconcomp.2008.12.010</mixed-citation></ref><ref id="scirp.120152-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Frohard, F. (2014) Durability of Green Concretes: Impact of Alternative Cementitious Materials on the Corrosion of Steel in Reinforced Concrete. Université Paris-Est, Paris.</mixed-citation></ref><ref id="scirp.120152-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Chen, M., Blanc, D., Gautier, M., Mehu, J. and Gourdon, R. (2013) Environmental and Technical Assessments of the Potential Utilization of Sewage Sludge Ashes (SSAs) as Secondary Raw Materials in Construction. Waste Management, 33, 1268-1275. https://doi.org/10.1016/j.wasman.2013.01.004</mixed-citation></ref><ref id="scirp.120152-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Moro, C., Francioso, V. and Velay-Lizancos, M. (2021) Modification of CO2 Capture and Pore Structure of Hardened Cement Paste Made with Nano-TiO2 Addition: Influence of Water-to-Cement Ratio and CO2 Exposure Age. Construction and Building Materials, 275, 122-131. https://doi.org/10.1016/j.conbuildmat.2020.122131</mixed-citation></ref><ref id="scirp.120152-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Binici, H., Kapur, S., Arocena, J. and Kaplan, H. (2012) The Sulphate Resistance of Cements Containing Red Brick Dust and Ground Basaltic Pumice with Sub-Microscopic Evidence of Intra-Pore Gypsum and Ettringite as Strengtheners. Cement and Concrete Composites, 34, 279-287. https://doi.org/10.1016/j.cemconcomp.2011.10.001</mixed-citation></ref><ref id="scirp.120152-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Hossain, K. (2003) Blended Cement Using Volcanic Ash and Pumice. Cement and Concrete Research, 33, 1601-1605. https://doi.org/10.1016/S0008-8846(03)00127-3</mixed-citation></ref><ref id="scirp.120152-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Kabay, N., Tufekci, M., Kizilkanat, A.B. and Oktay, D. (2015) Properties of Concrete with Pumice Powder and Fly Ash as Cement Replacement Materials. Construction and Building Materials, 85, 1-8. https://doi.org/10.1016/j.conbuildmat.2015.03.026</mixed-citation></ref><ref id="scirp.120152-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Conservation, B. (2010) Pozzolans for Lime Mortars. http://www.buildingconservation.com/articles/pozzo/lime-pozzolans.htm</mixed-citation></ref><ref id="scirp.120152-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Win, T., Dwiki, S., Hamanaka, A., Sasaoka, T., Shimada, H., Mastumot, S. and Kusuma, G. (2020) Application of Fly Ash and Organic Material as Dry Cover System in Prevention of Acid Mine Drainage Generation. Journal of Geoscience and Environment Protection, 8, 56-64. https://doi.org/10.4236/gep.2020.85004</mixed-citation></ref><ref id="scirp.120152-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Cyr, M., Klysz, G., Julien, S. and Clastres, P. (2003) Les cendres d’incinération de boues de stations de traitement des eaux polluées sont-elles utilisables dans les matrices cimentaires? Comparaison avec les cendres volantes de charbon. Revue Francophone D’écologie Industrielle, 29, 22-29. https://doi.org/10.4267/dechets-sciences-techniques.2227</mixed-citation></ref><ref id="scirp.120152-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">EUROSTAT (2020) Sewage Sludge Production and Disposal from Wastewater Treatment Plant Parameters.https://appsso.eurostat.ec.europa.eu/nui/show.do?dataset=env_ww_spd&amp;lang=en</mixed-citation></ref><ref id="scirp.120152-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Pan, S., Tseng, D., Lee, C.-C. and Lee, C. (2003) Influence of the Fineness of Sewage Sludge Ash on the Mortar Properties. Cement and Concrete Research, 33, 1749-1754. https://doi.org/10.1016/S0008-8846(03)00165-0</mixed-citation></ref><ref id="scirp.120152-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Brotons, F., Garces, P., Paya, J. and Saval, J. (2014) Portland Cement Systems with Addition of Sewage Sludge Ash. Application in Concretes for the Manufacture of Blocks. Journal of Cleaner Production, 82, 112-124.</mixed-citation></ref><ref id="scirp.120152-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">OECD (2017) Organization for Economic Co-Operation and Development. https://data.oecd.org/fr</mixed-citation></ref><ref id="scirp.120152-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Cyr, M., Coutand, M. and Clastres, P. (2007) Technological and Environmental Behaviour of Sewage Sludge Ash (SSA) in Cement-Based Materials. Cement and Concrete Research, 37, 1278-1289. https://doi.org/10.1016/j.cemconres.2007.04.003</mixed-citation></ref><ref id="scirp.120152-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Badur, S. and Chaudhary, R. (2008) Utilization of Hazardous Wastes and By-Products as a Green Concrete Material through S/S Process: A Review. Reviews on Advanced Materials Science, 1, 42-61.</mixed-citation></ref><ref id="scirp.120152-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Piasta, W. and Lukawska, M. (2016) The Effect of Sewage Sludge Ash on Properties of Cement Composites. Procedia Engineering, 161, 1018-1024. https://doi.org/10.1016/j.proeng.2016.08.842</mixed-citation></ref><ref id="scirp.120152-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, Y.F., Li, J.S., Lu, J.S., Cheeseman, C. and Poon, C. (2020) Sewage Sludge Ash: A Comparative Evaluation with Fly Ash for Potential. Construction and Building Materials, 242, 118-160. https://doi.org/10.1016/j.conbuildmat.2020.118160</mixed-citation></ref><ref id="scirp.120152-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Quintin, M., Riandey, C., Kersabiec, A.M. and Pinta, M. (1973) Effets de matrice comparés dans 1’analyse des silicates par spectrométrie d’émission d’absorption atomique et de fluorescence X. Analusis, 2, 516-531.</mixed-citation></ref><ref id="scirp.120152-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Traore, A. Ndiaye, P.M., Mbaye, M., Diatta, F. and Wague, A. (2014) X-Ray Fluorescence Combined with Chemometrics for the Characterization of Geological Samples: A Case Study in Southeastern Senegal. Instrumentation Science &amp; Technology, 42, 593-604. https://doi.org/10.1080/10739149.2014.915564</mixed-citation></ref><ref id="scirp.120152-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Sall, M., Traoré, A., Wade, A.C., Gueye, P.M., Diouf, S., Dieye, G. and Diop, D. (2021) Potential Use of Sewage Sludge Ash in Lime-Based Materials. Advances in Materials, 10, 12-22. https://doi.org/10.11648/j.am.20211002.11</mixed-citation></ref><ref id="scirp.120152-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Sall, M., Dieye, G., Traoré, A., Gueye, P.M., Diouf, S., Wade, A.C. and Diop, D. (2022) Technological and Environmental Behavior of Coal Fly Ash in Lime-Based Materials. Geomaterials, 12, 15-29. https://doi.org/10.4236/gm.2022.122002</mixed-citation></ref><ref id="scirp.120152-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Bal, H., Jannot, Y., Quenette, N., Chenu, A. and Gaye, S. (2012) Water Content Dependence of the Porosity Density and Thermal Capacity of Laterite Based Bricks with Millet Waste Additive. Construction and Building Materials, 31, 144-150. https://doi.org/10.1016/j.conbuildmat.2011.12.063</mixed-citation></ref><ref id="scirp.120152-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Rucinska, T., Glowacka, A. and Sidelko, R. (2021) The Influence of Incinerated Sewage Sludge as an Aggregate on the Selected Properties of Cement Mortars. Materials, 14, Article No. 5846. https://doi.org/10.3390/ma14195846</mixed-citation></ref><ref id="scirp.120152-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Sall, M., Gueye, P.M., Traore, A., Diouf, S., Sy, M., Bouchez, G., Wade, A.C., Sane, M., Dieye, G. and Diop, D. (2020) Assessment of Fine and Coarse Sewage Sludge Ashes for Their Potential Use in Civil Engineering. Journal of Civil, Construction and Environmental Engineering, 5, 99-106. https://doi.org/10.11648/j.jccee.20200504.13</mixed-citation></ref><ref id="scirp.120152-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Neupane, K. (2016) Fly Ash and GGBFS Based Powder-Activated Geopolymer Binders: Available Sustainable Alternative of Portland Cement in Concrete Industry. Mechanics of Materials, 103, 110-122. https://doi.org/10.1016/j.mechmat.2016.09.012</mixed-citation></ref><ref id="scirp.120152-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Coo, M. and Pheeraphan, T. (2016) Effect of Sand, Fly Ash and Limestone Powder on Preplaced Aggregate Concrete Mechanical Properties and Reinforced Beam Shear Capacity. Construction and Building Materials, 120, 581-592. https://doi.org/10.1016/j.conbuildmat.2016.05.128</mixed-citation></ref><ref id="scirp.120152-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">ASTM C 618-03 (2003) Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete.</mixed-citation></ref><ref id="scirp.120152-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Xu, W., Xu, J., Liu, J., Li, H., Cao, B., Huang, X. and Li, G. (2014) The Utilization of Lime Dried Sludge as Resource for Producing Cement. Journal of Cleaner Production, 83, 286-293. https://doi.org/10.1016/j.jclepro.2014.07.070</mixed-citation></ref><ref id="scirp.120152-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Rodríguez, N.H., Ramírez, S., Varela, B., Donatello, S., Guillem, M., Puig, J., Fos, C., Flores and Larrotcha, J. (2013) The Effect of Using Thermally Dried Sewage Sludge as an Alternative Fuel on Portland Cement Clinker Production. Journal of Cleaner Production, 52, 94-102. https://doi.org/10.1016/j.jclepro.2013.02.026</mixed-citation></ref><ref id="scirp.120152-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Rosas-Casarez, C.A., Arredondo-Rea, S., Gómez-Soberón, J., Alamaral-Sánchez, J., Corral-Higuera, R., Chinchillas-Chinchillas, M. and Acu&amp;#241;a-Agüero, O.H. (2014) Experimental Study of XRD, FTIR and TGA Techniques in Geopolymeric Materials. International Journal of Advances in Computer Science &amp; Its Applications, 4, 221-225.</mixed-citation></ref><ref id="scirp.120152-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Vogel, C., Kohl, A. and Adam, C. (2011) Spectroscopic Investigation in the Mid- and Far-Infrared Regions of Phosphorus Fertilizers Derived from Thermochemically Treated Sewage Sludge Ash. Applied Spectroscopy, 65, 265-271. https://doi.org/10.1366/10-06168</mixed-citation></ref><ref id="scirp.120152-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Tantawy, M.A., El-Roudi, A.M., Abdalla, E.M. and Abdelzaher, M.A. (2012) Evaluation of the Pozzolanic Activity of Sewage Sludge Ash. ISRN Chemical Engineering, 2012, 1-8. https://doi.org/10.5402/2012/487037</mixed-citation></ref><ref id="scirp.120152-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">LeGeros, R.Z. and LeGeros, J. (1993) Dense Hydroxyapatite. In: An Introduction to Bioceramics, World Scientific, Singapore, 139-180. https://doi.org/10.1142/9789814317351_0009</mixed-citation></ref><ref id="scirp.120152-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Farcas, F. and Touzé, P. (2001) La Spectroscopie Infrarouge à Transformé de Fourier (IRTF). Bulletin des laboratoires des ponts et chaussées, 230, 77-88.</mixed-citation></ref><ref id="scirp.120152-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Marti, K. (2002) Catalogue d’éléments de construction avec calcul de la valeur U. Office fédéral de l’energie.</mixed-citation></ref><ref id="scirp.120152-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Laaroussi, N., Cherkia, A., Garoum, M., Khabbazi, A. and Feiz, A. (2013) Thermal Properties of a Sample Prepared Using Mixtures of Clay Bricks. Energy Procedia, 42, 337-346. https://doi.org/10.1016/j.egypro.2013.11.034</mixed-citation></ref><ref id="scirp.120152-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">Sall, M., Gueye, P.M., Wade, A.C., Traoré, A., Dieye, G, Diouf, S., Sané, M. and Diop, D. (2021) Pollution Hazards of Heavy Metals in Sewage Sludge Ash from the Wastewater Treatment Plants in Camberene, Senegal. International Journal of Advanced Research, 9, 946-953. https://dx.doi.org/10.21474/IJAR01/13826</mixed-citation></ref></ref-list></back></article>