<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBiSE</journal-id><journal-title-group><journal-title>Journal of Biomedical Science and Engineering</journal-title></journal-title-group><issn pub-type="epub">1937-6871</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbise.2022.157016</article-id><article-id pub-id-type="publisher-id">JBiSE-118475</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject></subj-group></article-categories><title-group><article-title>
 
 
  Selection of Hammering Sound Collection Devices for the Development of Total Hip Arthroplasty Support Systems
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Rina</surname><given-names>Sakai</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Katsufumi</surname><given-names>Uchiyama</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shun</surname><given-names>Nishizawa</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tomomi</surname><given-names>Mizuhashi</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Takeaki</surname><given-names>Yamamoto</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kazuhiro</surname><given-names>Yoshida</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kensuke</surname><given-names>Fukushima</given-names></name><xref ref-type="aff" rid="aff5"><sup>5</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Naonobu</surname><given-names>Takahira</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Masanobu</surname><given-names>Ujihira</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Kanagawa, Japan</addr-line></aff><aff id="aff2"><addr-line>Kitasato University Graduate School of Medical Sciences, Kanagawa, Japan</addr-line></aff><aff id="aff4"><addr-line>Department of Orthopedic Surgery, St. Marianna University School of Medicine, Kanagawa, Japan</addr-line></aff><aff id="aff3"><addr-line>Department of Clinical Engineering, St. Luke’s International Hospital, Tokyo, Japan</addr-line></aff><aff id="aff5"><addr-line>Department of Orthopedic Surgery, Kitasato University School of Medicine, Kanagawa, Japan</addr-line></aff><pub-date pub-type="epub"><day>14</day><month>07</month><year>2022</year></pub-date><volume>15</volume><issue>07</issue><fpage>179</fpage><lpage>186</lpage><history><date date-type="received"><day>1,</day>	<month>June</month>	<year>2022</year></date><date date-type="rev-recd"><day>11,</day>	<month>July</month>	<year>2022</year>	</date><date date-type="accepted"><day>14,</day>	<month>July</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In total hip arthroplasty, intraoperative femoral fractures can be avoided by analyzing the hammering sounds from the stem inserted into the femur. This procedure is based on a hammering test that makes use of the fact that sound depends on the stability of the object. This technique is generally used in engineering. A system designed to avoid excessive stem hammering by predicting the intraoperative fracture risk based on this technique and software for real-time spectra analysis has been developed with repetitive improvements. The remaining technical challenge lies in selecting an appropriate sound collection device and building a compact and easy unit for use. This study reviewed the types of directional microphones suitable for the sound collection system to develop a practical THA support system. Four types of microphones based on selected methods were used to collect and compare the peak frequencies of the hammering sounds and make comparisons between them, and the built system was used to conduct clinical trials. For miniaturization and operational ease of the unit, plug-in unidirectional microphones are appropriate. However, no laboratory-level data has been collected, and thus, further data accumulation is necessary.
 
</p></abstract><kwd-group><kwd>Intraoperative Fractures</kwd><kwd> Total Hip Arthroplasty</kwd><kwd> Hammering Sound</kwd><kwd> Fourier Analysis</kwd><kwd> Peak Frequency</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. INTRODUCTION</title><p>Total hip arthroplasty (THA) is a surgical procedure to replace a hip joint, with hip prostheses, that has lost its functionality. The developments in hip arthroplasty over recent years have aimed to improve outcomes, reduce complications [1 - 3]. However, it has been reported that during surgery, serious intraoperative fractures occur at a rate between 0.4% and 4.9% [3 - 5].</p><p>One of the causes of intraoperative femoral fracture is the fact that no criterion is available for deciding whether the stem is sufficiently stable [<xref ref-type="bibr" rid="scirp.118475-ref6">6</xref>]. Currently, surgery is dependent on the surgeon’s experience and sense without being based on the objective data. An insufficiently fixation stem results in insufficient stability. A stem excessively fix to increase stability causes intraoperative fracture; this means that it is possible to avoid intraoperative fracture by appropriate fixation the stem during surgery based on scientific grounds (see <xref ref-type="fig" rid="fig1">Figure 1</xref>).</p><p>Research till date indicates that with a focus on the fact that the sound depends on the object’s stability, it is possible to avoid intraoperative fracture by analyzing hammering sounds from the stem being fix into the femur [7 , 8]. A system has been built to avoid intraoperative fractures, and software for fast Fourier analysis has been developed with repetitive improvements [9 , 10]. The remaining technical challenge is to select an appropriate sound collection device and build a compact unit that is easy to use.</p><p>To develop a practical THA support system, this study focused on the following three points, particularly those associated with the selection of sound collection systems. First, the type of directional microphone suitable for a sound collection system was reviewed. Next, four types of microphones based on the selected methods were used to collect and compare the peak frequencies of the hammering sounds and make comparisons between them. Finally, the built system was used to conduct clinical trials.</p></sec><sec id="s2"><title>2. MATERIALS AND METHODS</title><p>Selection of microphones</p><p>The THA support system for preventing intraoperative fractures consists of a dual-channel sensor amplifier (SR-2200 from Ono Sokki, Japan), a digital storage scope (DSO-2250 USB from Hantek Electronic Co. Ltd., China), and a laptop computer (Endeavor NJ1000 from Epson, Japan). To select the most suitable directional microphone to be incorporated into this support system, comparisons were made among the electret-condenser, dynamic, and DC-biased condenser types. <xref ref-type="table" rid="table1">Table 1</xref> lists the types, output levels, noise levels, sensitivity levels, and sound qualities of the microphones.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Type of microphones, output, noise, sensitivity and sound quality</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Type</th><th align="center" valign="middle" >Output</th><th align="center" valign="middle" >Noise</th><th align="center" valign="middle" >Sensitivity</th><th align="center" valign="middle" >Sound quality</th></tr></thead><tr><td align="center" valign="middle" >Electret condenser type</td><td align="center" valign="middle" >Normal</td><td align="center" valign="middle" >Normal</td><td align="center" valign="middle" >Normal</td><td align="center" valign="middle" >Versatile and delicate. Compared to the DC bias type, it cannot pick up minute level sound.</td></tr><tr><td align="center" valign="middle" >Dynamic type</td><td align="center" valign="middle" >Low</td><td align="center" valign="middle" >Normal</td><td align="center" valign="middle" >Low</td><td align="center" valign="middle" >Suitable for high volume recording</td></tr><tr><td align="center" valign="middle" >DC bias capacitor type</td><td align="center" valign="middle" >High</td><td align="center" valign="middle" >Low</td><td align="center" valign="middle" >High</td><td align="center" valign="middle" >Delicate and smooth. Abundant information at a minute level.</td></tr></tbody></table></table-wrap><p>Four types of dynamic and DC-biased condenser directional microphones, namely, Type A (F-P5500 from Sony, Japan), Type B (BETA58A from Shure Inc., IL, USA), Type C (C391 from Harman International Japan Co. Ltd., CT, USA), and Type D (BP4073 from Audio-Technica Corporation, Japan), were incorporated into the THA support system to collect hammering sounds under the same conditions. Types A and B are dynamic microphones, and Types C and D are DC-biased condenser microphones. <xref ref-type="table" rid="table2">Table 2</xref> lists the directivities and frequency responses of microphones.</p><p>In the laboratory, systems (VerSys from Zimmer, USA) were implanted into simulated femurs (Sawbones Medium Left Femur 1121-19: Pacific Research Laboratory, WA, USA). With the surgical equipment used in clinical trials, the systems were fixed using the same procedure as that of the THA using a hammer (VerSys from Zimmer, USA) through an inserter (VerSys from Zimmer, USA). Directional microphones were placed approximately 1 m away from the simulated femurs. Six simulated femurs were used for each microphone. An FFT analyzer (DS-3000, Onosokki, Japan) was used to perform short-time Fourier transformations to calculate the peak frequencies at which the amplitudes were maximized.</p><p>Clinical trials</p><p>This study was approved by the ethics commission of the organization to which the author belongs (B16-239). Clinical trials were conducted on 12 joints in 12 cases of total hip replacements (for four male patients and eight female patients, with a mean age of 70.1 years old), conducted from June to December 2017 at Kitasato University Hospital. The surgery was performed by an orthopedic surgeon specializing in the hip joint, with more than 20 years of clinical experience.</p><p>As equipment to be carried into operating rooms, the system had to be a compact, easy-to-use unit. Microsoft Visual Studio 2010 was used as the development platform, and Microsoft Visual C# 2010 was used as the programming language to develop an application. The application normally runs on a PC Miix 2 8 (from Lenovo Corporation, China), a tablet PC equipped with Windows as the operating system (OS).</p><p>Changes were made to the software and hardware of the THA support system; thus, microphones were selected again. Comparisons were made between Microphone A (F-P5500 from SONY, Japan), a handheld unidirectional microphone that exhibited the best performance in the laboratory; microphone E (i266 from MI Seven Japan Inc., Japan), a plug-in unidirectional cordless microphone that directly connects to a tablet; and microphone F, a plug-in super-directive small microphone (AT9913 from Audio-Technica Corporation, Japan) (<xref ref-type="table" rid="table3">Table 3</xref>). With the microphones placed 2 m away from the surgical field, one microphone and the system were used to analyze each case. Each microphone was randomly allocated to four of the 12 cases. <xref ref-type="table" rid="table3">Table 3</xref> lists the directivities and frequency responses of the microphones.</p></sec><sec id="s3"><title>3. RESULTS</title><p>The four types of directional microphones A, B, C, and D exhibited peak frequencies of 0.70 &#177; 0.03 kHz, 0.30 &#177; 0.09 kHz, 0.72 &#177; 0.01 kHz, and 0.67 &#177; 0.05 kHz, respectively. Unlike the other microphones, microphone A clearly exhibited its peak frequency (<xref ref-type="fig" rid="fig2">Figure 2</xref>(A)). Microphone B exhibited a peak frequency more than 1 kHz, which was lower than the peak frequencies of the other microphones (see <xref ref-type="fig" rid="fig2">Figure 2</xref>(B)). Microphone C exhibited a smooth waveform, but its peak frequencies, the most critical data, were scattered (<xref ref-type="fig" rid="fig2">Figure 2</xref>(C)). Microphones B and D were characterized by picking up low-frequency sounds (<xref ref-type="fig" rid="fig2">Figure 2</xref>(D)).</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Characteristics of the microphones used in the laboratory</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Type</th><th align="center" valign="middle" >Product</th><th align="center" valign="middle"  colspan="2"  >Directivity</th><th align="center" valign="middle" >Frequency characteristics</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >Dynamic type</td><td align="center" valign="middle" >A</td><td align="center" valign="middle" >Unidirectional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x6.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >50 Hz - 20 kHz</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >Super directional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x7.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >50 Hz - 16 kHz</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >DC bias capacitor type</td><td align="center" valign="middle" >C</td><td align="center" valign="middle" >Unidirectional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x8.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >20 Hz - 20 kHz</td></tr><tr><td align="center" valign="middle" >D</td><td align="center" valign="middle" >Super directional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x9.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >20 Hz - 20 kHz</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Characteristics of the microphones used in the operating room</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Type</th><th align="center" valign="middle" >Product</th><th align="center" valign="middle"  colspan="2"  >Directivity</th><th align="center" valign="middle" >Frequency characteristics</th></tr></thead><tr><td align="center" valign="middle" >Dynamic type</td><td align="center" valign="middle" >A</td><td align="center" valign="middle" >Unidirectional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x10.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >50 Hz - 20 kHz</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Plug in type</td><td align="center" valign="middle" >E</td><td align="center" valign="middle" >Unidirectional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x11.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >20 Hz - 20 kHz</td></tr><tr><td align="center" valign="middle" >F</td><td align="center" valign="middle" >Super directional</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="/html.scirp.org/file/1-9102803x12.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >70 Hz - 15 kHz</td></tr></tbody></table></table-wrap><p>In the clinical trials, microphone A failed to detect one hammering sound in one of the four cases. The x plot in <xref ref-type="fig" rid="fig3">Figure 3</xref>(A) shows the undetected data that is one miscounted hammering sound out of a series of 58 hammering sounds collected by microphone A. Microphone B did not fail to detect any hammering sounds in all cases. Microphone C failed to detect hammering sounds in all cases, with 4 &#177; 3.16 counting errors per case. <xref ref-type="fig" rid="fig3">Figure 3</xref>(B) shows one of the four cases where microphone C was used, with five counting errors observed out of 96 hammerings performed.</p></sec><sec id="s4"><title>4. DISCUSSION</title><p>The frequency components that constitute the hammering sound are the characteristic frequencies of the hammer and the inserter [<xref ref-type="bibr" rid="scirp.118475-ref11">11</xref>]. Zhuanget al. stated that the frequency components of the hammering sound are almost independent of the manufacturers of the inserter and hammer [<xref ref-type="bibr" rid="scirp.118475-ref1">1</xref>]. Based on previous research, we reported that the peak frequency is approximately 3 kHz [<xref ref-type="bibr" rid="scirp.118475-ref10">10</xref>]. Microphone A exhibited a peak frequency near this value, which did not scatter significantly. Dynamic microphones are inexpensive and suitable for collecting large amount of sound [<xref ref-type="bibr" rid="scirp.118475-ref12">12</xref>]. We believe that dynamic microphones are suitable for bone fracture prevention devices because they are tolerant to rough handling in clinical practice and are easy to handle.</p><p>Dynamic microphones are disadvantageous because their output and sensitivity levels are low, although the dynamic microphone is cheap enough for collecting of sound [<xref ref-type="bibr" rid="scirp.118475-ref12">12</xref>]. DC-biased condensers exhibited high output and sensitivity levels. However, they are precision optical instruments that are expensive and require careful handling (for example, exposure to high temperatures and humidity must be avoided). For these reasons, we believe that they are inappropriate as devices used in operating rooms. With their excellent collection of low-pitched sounds, DC-biased condensers can collect abundant micro-information. However, hammering sounds are high-pitched and not delicate; thus, the microphone does not need to be of a DC-biased condenser type [<xref ref-type="bibr" rid="scirp.118475-ref13">13</xref>]. Electret condenser microphones provide fine sound quality because they include batteries and an electronic circuit. However, demerits of electret condenser microphones may cause battery leakage because batteries are always kept inside them and are thus excluded from the selection [<xref ref-type="bibr" rid="scirp.118475-ref14">14</xref>].</p><p>Although the laboratory study revealed that Microphone A, a handheld unidirectional type, performed excellently, we thought that the microphone should be smaller in size as it must be carried into operating rooms. Microphone A, E, and F are handheld unidirectional, plug-in unidirectional, and plug-in superdirective type, respectively, and the frequency responses cover the frequency range of the hammering sound. The microphone cannot be placed near the sound source, that is, the surgical field; therefore, we expected that the superdirective type would be suitable for collecting sounds. However, the results showed that the unidirectional types were excellent. We found that the unidirectional types collected sound in a wider area than the superdirective types and thus picked up sounds that came around the barrier, the operator, and from the sound source [<xref ref-type="bibr" rid="scirp.118475-ref15">15</xref>].</p><p>Given that the first prerequisite for the sound collection device was compactness, we determined that microphone E was appropriate. However, the amount of data is insufficient, and thus must be increased so that statistics can be maintained. In clinical trials, ossein is not consistent; thus, it is difficult to handle the obtained qualitative data. Therefore, laboratory-level data was collected again. If the microphone is required not to make many misdetections, it may be deemed that Microphone A, a dynamic handheld unidirectional type, or the plug-in unidirectional microphone, is appropriate as a sound collection device for the THA support system. As a limitation, we considered the material of the microphone did not influence the results. We have not confirmed whether there is a difference between gender and age in the collected data.</p></sec><sec id="s5"><title>5. CONCLUSION</title><p>It is necessary to discuss the criteria for determining whether the stem is sufficiently stable. As one approach, intraoperative fractures can be avoided by analyzing the hammering sound from the stem inserted into the femur. A system was built to avoid intraoperative fracture risk based on this technique, and software for real-time analysis has been developed with repetitive improvements in the THA support system. The remaining technical challenge is to select an appropriate sound collection device. This study revealed that dynamic handheld unidirectional microphones are suitable for collecting sounds. To achieve miniaturization and operational ease of the THA support system, plug-in unidirectional microphones are found to be appropriate. However, no laboratory-level data has been collected for plug-in unidirectional microphones; therefore, data collection must be increased in the future.</p></sec><sec id="s6"><title>ACKNOWLEDGEMENTS</title><p>This study was supported by a Kitasato University School of Allied Health Sciences (Grant-in-Aid for Research Project, No. 2017-2021, 6610), KAKENHI Grant Number JP 26820160. We are grateful to Yasuo Otsu, Masahiro Kakeshita, and Takanori Usui for their assistance.</p></sec><sec id="s7"><title>CONFLICTS OF INTEREST</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s8"><title>REFERENCES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.118475-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Zhuang, X., Homma, Y., Ishii, S., Shirogane, Y., Tanabe, H., Baba, T., Kaneko, K., Sato, T. and Ishijima, M. (2022) Acoustic Characteristics of Broaching Procedure for Post-Operative Stem Subsidence in Cementless Total Hip Arthroplasty. International Orthopaedics, 46, 741-748. https://doi.org/10.1007/s00264-021-05278-w</mixed-citation></ref><ref id="scirp.118475-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Mihalko, W.M., Wimmer, M.A., Pacione, C.A., Laurent, M.P., Murphy, R.F. and Rider, C. (2014) How Have Alternative Bearings and Modularity Affected Revision Rates in Total Hip Arthroplasty? Clinical Orthopaedics and Related Research, 472, 3747-3758. https://doi.org/10.1007/s11999-014-3816-2</mixed-citation></ref><ref id="scirp.118475-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Moroni, A., Faldini, C., Piras, F. and Giannini, S. (2000) Risk Factors for Intraoperative Femoral Fractures during Total Hip Replacement. Annales Chirurgiae et Gynaecologiae, 89, 113-118.</mixed-citation></ref><ref id="scirp.118475-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Schwartz, J.T., Mayer, J.G. and Engh, C.A. (1989) Femoral Fracture during Non-Cemented Total Hip Arthroplasty. The Journal of Bone and Joint Surgery, 71, 1135-1142. https://doi.org/10.2106/00004623-198971080-00003</mixed-citation></ref><ref id="scirp.118475-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">White, C.A., Carsen, S., Rasuli, K., Feibel, R.J., Kim, P.R. and Beaulé, P.E. (2012) High Incidence of Migration with Poor Initial Fixation of the Accolade&amp;#174; Stem. Clinical Orthopaedics and Related Research, 470, 410-417. https://doi.org/10.1007/s11999-011-2160-z</mixed-citation></ref><ref id="scirp.118475-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Morohashi, I., Iwase, H., Kanda, A., Sato, T., Homma, Y., Mogami, A., Obayashi, O. and Kaneko, K. (2017) Acoustic Pattern Evaluation during Cementless Hip Arthroplasty Surgery May Be a New Method for Predicting Complications. SICOT-J, 3, 13. https://doi.org/10.1051/sicotj/2016049</mixed-citation></ref><ref id="scirp.118475-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Sakai, R., Kikuchi, A., Morita, T., Takahira, N., Uchiyama, K., Yamamoto, T., Moriya, M., Uchida, K., Fukusima, K., Tanaka, K., Takaso, M., Itoman, M. and Mabuchi, K. (2011) Hammering Sound Frequency Analysis and Prevention of Intraoperative Periprosthetic Fractures during Total Hip Arthroplasty. Hip International, 21, 718-723. https://doi.org/10.5301/HIP.2011.8823</mixed-citation></ref><ref id="scirp.118475-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Sakai, R., Yamamoto, T., Uchiyama, K., Takahira, N., Kakeshita, M.., Otsu, Y., Yoshida, K. and Ujihira, M. (2020) Prediction of Intraoperative Fracture by Hammering Sound Frequency Analysis and Stress Estimation during Total Hip Arthroplasty. Journal of Biomedical Science and Engineering, 13, 113-119. https://doi.org/10.4236/jbise.2020.136011</mixed-citation></ref><ref id="scirp.118475-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Sakai, R., Uchiyama, K., Takahira, N., Kakeshita, M.., Otsu, Y., Yoshida, K. and Ujihira, M. (2020) Usefulness of Hammering Sound Frequency Analysis as an Evaluation Method for the Prevention of Trouble during Hip Replacement. Journal of Biomedical Science and Engineering, 13, 74-80. https://doi.org/10.4236/jbise.2020.135007</mixed-citation></ref><ref id="scirp.118475-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Sakai, R., Uchiyama, K., Kensuke, F., Takahira, N., Yoshida, K. and Ujihira, M. (2021) Hammering Sound Frequency Analysis to Fix an Acetabular Cup during Total Hip Arthroplasty: Clinical Trials and Biomechanical Studies. Journal of Biomedical Science and Engineering, 14, 14-20. https://doi.org/10.4236/jbise.2021.141003</mixed-citation></ref><ref id="scirp.118475-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Whitwell, G., Brockett, L.C., Young, S., Stone, M. and Stewart, D.T. (2013) Spectral Analysis of the Sound Produced during Femoral Broaching and Implant Insertion in Uncemented Total Hip Arthroplasty. Journal of Engineering in Medicine, 227, 175-180. https://doi.org/10.1177/0954411912462813</mixed-citation></ref><ref id="scirp.118475-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Jin, X. and Ling, S.L. (2012) A Method of Measuring Acoustic Absorption Coefficient of a Material Specimen Using a Dynamic Microphone. Journal of Mechanical Science and Technology, 26, 741-748. https://doi.org/10.1007/s12206-011-1235-9</mixed-citation></ref><ref id="scirp.118475-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Pederson, M., Olthuis, W. and Bergveld, P. (1998) High-Performance Condenser Microphone with Fully Integrated CMOS Amplifier and DC-DC Voltage Converter. Journal of Microelectromechanical Systems, 7, 387-394. https://doi.org/10.1109/84.735346</mixed-citation></ref><ref id="scirp.118475-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Micro and Nano Technologies (2020) Handbook of Silicon Based MEMS Materials and Technologies. Third Edition, Elsevier, Amsterdam, 937-948.</mixed-citation></ref><ref id="scirp.118475-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Bauer, B.B. (1941) Uniphase Unidirectional Microphones. The Journal of the Acoustical Society of America, 13, 41. https://doi.org/10.1121/1.1916145</mixed-citation></ref></ref-list></back></article>