<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">Detection</journal-id><journal-title-group><journal-title>Detection</journal-title></journal-title-group><issn pub-type="epub">2331-2076</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/detection.2022.92002</article-id><article-id pub-id-type="publisher-id">Detection-117219</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Direct Conversion X-Ray Detectors with High Sensitivity at Low Dose Rate Based on All-Inorganic Lead-Free Perovskite Wafers
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Cuixian</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sub>1</sub></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><label>1</label><addr-line>Chengdu University of Information and Technology, Chengdu, China</addr-line></aff><pub-date pub-type="epub"><day>30</day><month>04</month><year>2022</year></pub-date><volume>09</volume><issue>02</issue><fpage>13</fpage><lpage>27</lpage><history><date date-type="received"><day>6,</day>	<month>March</month>	<year>2022</year></date><date date-type="rev-recd"><day>27,</day>	<month>April</month>	<year>2022</year>	</date><date date-type="accepted"><day>30,</day>	<month>April</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs
  <sub>3</sub>Bi
  <sub>2</sub>I
  <sub>9</sub> single crystals (SCs). However, compared with lead-halide perovskites, one challenge for the Cs
  <sub>3</sub>Bi
  <sub>2</sub>I
  <sub>9</sub> SCs for X-ray detection application is that it is difficult to prepare large-sized and high-quality SCs. Therefore, how to get a large area with a high-quality wafer is also as important as Cs
  <sub>3</sub>Bi
  <sub>2</sub>I
  <sub>9</sub> growth method research. Here, different anti-solvents are used for the preparation of poly-crystalline powder with the Antisolvents precipitation (A) method, as a control, High-energy ball milling (B) was also used to prepare poly-crystalline powders. The resultant two types of Cs
  <sub>3</sub>Bi
  <sub>2</sub>I
  <sub>9</sub> wafer exhibit a micro-strain of 1.21 &#215; 10
  <sup>-3</sup>, a resistivity of 5.13 &#215; 10
  <sup>8</sup> Ω cm and a microstrain of 1.21 &#215; 10
  <sup>-3</sup>, a resistivity of 2.21 &#215; 10
  <sup>9</sup> Ω cm. As a result, an X-ray detector based on the high-quality Cs
  <sub>3</sub>Bi
  <sub>2</sub>I
  <sub>9</sub> wafer exhibits excellent dose rate linearity, a sensitivity of 588 μC&#183;Gyairs
  <sup>-1</sup>&#183;cm
  <sup>-2</sup> and a limit of detection (LoD) of 76 nGyair&#183;s
  <sup>-1</sup>.
 
</p></abstract><kwd-group><kwd>X-Ray Detection</kwd><kwd> Sensitivity</kwd><kwd> Cs&lt;sub&gt;3&lt;/sub&gt;Bi&lt;sub&gt;2&lt;/sub&gt;I&lt;sub&gt;9&lt;/sub&gt;</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>In recent years, perovskite material (ABX<sub>3</sub>), has been widely used in solar cell, visible light detection and Quantum dot luminescent material due to its high absorption coefficient, tunable bandgap and also has achieved a huge success in radiation detection [<xref ref-type="bibr" rid="scirp.117219-ref1">1</xref>] - [<xref ref-type="bibr" rid="scirp.117219-ref7">7</xref>].<sup> </sup></p><p>In 2015, Yakunin et al. prepared a uniformly dense MAPbI<sub>3</sub> film by spin coating or spraying on the substrate, prepared photodetectors based on the film, and successfully obtained X-ray images [<xref ref-type="bibr" rid="scirp.117219-ref8">8</xref>]. Since then, many researchers have joined in the application of perovskite materials in X-ray detection research, and have achieved very excellent results [<xref ref-type="bibr" rid="scirp.117219-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref12">12</xref>]. But the existence of organic groups affects the stability of organic-inorganic hybrid perovskite materials. And the toxic of lead may cause environmental pollution, potential leakage and other dangers. Therefore, the research on inorganic lead-free perovskite materials is in full swing.</p><p>There are many lead-free perovskite materials, but Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> is more suitable for X-ray detection because of its very similar structure to the Pb atomic shell structure and its large atomic massBi-based lead-free perovskite materials, including MA<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub>, are outstanding in lead-free perovskite class.</p><p>In 2020, Zhang et al. grew centimeter-scale Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystals by high-temperature solution heating method and shape nucleus control. The sensitivity of the single crystal was as high as 1652.3 μC∙Gyair<sup>−1</sup>∙cm<sup>−2</sup>, and the detection limit was relatively low, reaching 130 nGyair∙s<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.117219-ref13">13</xref>]. Sun et al. prepared a 15 mm diameter Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystal by Briman hair [<xref ref-type="bibr" rid="scirp.117219-ref14">14</xref>]. The MA<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystal sensitivity prepared by Liu et al. reached 872 &#181;C∙Gy<sup>−1</sup>∙cm<sup>−2</sup> and the detection limit reached a very low 30 nGyair∙s<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.117219-ref15">15</xref>]. The above reports are based on photoconductive X-ray detectors based on perovskite materials. In recent years, some X-ray detectors are made of perovskite materials as new scintillator materials, which also have excellent performance [<xref ref-type="bibr" rid="scirp.117219-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref18">18</xref>].</p><p>At present, there are many methods to prepare the photosensitive layer of X-ray detector in reported studies. The main methods currently used include spinning coating, scraping coating on the substrate to prepare polycrystalline thick film, melting method, solution method and other methods to grow perovskite single crystal and so on. However, spin coating method such as preparation of polycrystalline film thickness to meet the most X-ray materials of the best absorption thickness, and single crystal while performance is more outstanding, but its growth cycle taking a long time, the solution method of controllability and repeatability is poor, difficult to get the single crystal of large area. How to obtain high-quality large area to detect the cause of the core material? In this paper, piezoelectric ceramics and other experimental preparation methods were used to obtain the detector transport layer by pressing the polycrystalline powder obtained by the anti-solvent directly. In this paper, piezoelectric ceramics and other experimental preparation methods were used to obtain the detector transport layer by pressing the polycrystalline powder obtained by the anti-solvent directly.</p></sec><sec id="s2"><title>2. Experimental</title><p>Preparation of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> Microcrystalline Powder: cesium iodide (CsI, 99.9%), bismuth triiodide (BiI<sub>3</sub>, 99.9%), N, N-dimethylformamide (DMF, 99.5%), dimethyl sulfoxide (DMSO, 99%) and Isopropyl alcohol (IPA, 99.5%) were purchased from Aladin. All materials were used as received without further purification.</p><p>Two methods were employed to prepare Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> polycrystalline powder, including A method and B method. In A case, CsI and BiI<sub>3</sub> with a mole ration of 3:2 was dissolved in DMF and DMSO component solvent (DMF:DMSO = 3:7). Immediately, the mixture was string at room temperature for 12 h. Add the clarified saturated solution filtered by 0.8 μm PVDF filter into antisolvents isopropyl IPA, then centrifuge the orange turbid liquid, pull off the supernatant liquid, add appropriate amount IPA into centrifuge tube, then repeat the steps several times. Then, the sediment is vacuum-dried for12 hours. As for B method, CsI and BiI<sub>3</sub> with same mole ration was mixed in the agate jar with agate balls, was milling for 8 h. The powders obtained by the above two methods will be used as pressing materials to get the photoelectric conversion layer.<sub> </sub></p><p>Material Characterization: Crystallization characteristics and phase analysis were characterized by X-ray Diffractometer (XRD: TD-3500, HAO YUAN Instrument). The Optical properties were measured and characterized by UV-VIS spectrometer (UV-2550, Shimadzu). Thermal stability was characterized by Thermogravimetric Analysis instrument (STA 2500 Regulus, Shimadzu).</p><p>Fabrication of Devices: The polycrystalline powder obtained previously was pressed into shape at a pressure of 24 tons. The vertical Au/Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer/Au devices were fabricated by depositing Au on two opposite surfaces of the slices, and the active area (electrode area) is 1 &#215; 8 mm<sup>2</sup>. For resistivity and X-ray response investigate, 0.8 Pa, 4 min, 6 μA was selected as the best deposition electrode process, Au electrode with thickness of 40 nm was obtained, the thickness of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer-A and wafer-B are 666 μm and 568 μm, respectively.</p><p>Device Characterization: The electrical properties and X-ray response of devices were characterized by Agilent (B2912A). A tungsten anode X-ray tube (Series 5000, Oxford Instruments) was used to perpendicularly irradiate devices. The dose rates were regulated by a gas ionization detector dosemeter system (ACCU-GOLD Touch AGD-P-AD, ACCU Digitizer AGDM+ and 10X6-3CT, Radcal). All equipment measurements are made under atmospheric ambient conditions and at room temperature. The test system is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p></sec><sec id="s3"><title>3. Result and Disccution</title><sec id="s3_1"><title>3.1. Characterizations of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></title><p>1) XRD</p><p>According to the current research, the photoelectric response of the device is closely related to the crystal quality of the materials. In order to obtain polycrystalline powder materials with excellent crystallization performance, the effects of different anti-solvents on crystallization performance of polycrystalline powder were investigated in the synthesis of polycrystalline powder by antisolvent method. Finally, we choose isopropanol as anti-solvents from ethanol, isopropanol, dichloromethane, n-hexane.</p><p>It is easy to find from the XRD pattern by horizontal comparison (<xref ref-type="fig" rid="fig2">Figure 2</xref>), the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> microcrystals synthesized by anti-solvent experiments have good crystallinity and are in good agreement with the standard PDF cards, as for Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> powder prepared by ball milling method is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>(b), the diffraction peak intensity is lower and the FWHM is large, indicating that the crystallinity is poor. The strongest diffraction intensity is lower than half of the worst strength of polycrystalline powder prepared by anti-solvent method. Vertical comparison, materials are obviously recrystallized after isostatic pessing treatment, the intensity of &lt;006&gt; in two wafer sample were stronger than powder, It can be said that &lt;006&gt; becomes the dominant crystal plane. Both ASP and HEBM dominant crystal faces, the {001} crystallographic plane families’ diffraction peaks of wafer are stronger than powder, meanwhile, the 100 crystallographic plane families’ diffraction peaks are weaker, even the &lt;110&gt; was disappear. As we know Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> is a hexagonal crystal system with the densest atoms and lowest energy along the C-axis, so the pressure recrystallizes the polycrystalline powder with energy. Therefore, the densest atoms provide the possibility of better X-ray absorption.</p><p>2) UV-VIS</p><p>The band gap of samples prepared by anti-solvent method is 2.24 eV. It is consistent with the theoretical and the calculated band gap of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> (2.30 eV) [<xref ref-type="bibr" rid="scirp.117219-ref19">19</xref>]. However, it is quite different from the actual reported band gap of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystal material (1.96 eV [<xref ref-type="bibr" rid="scirp.117219-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.117219-ref20">20</xref>]). The possible reason is that the crystal grains are relatively small. According to the quantum domain effect, the smaller the crystal grains are, the more hypsochromic shift the absorption edge will be, and the band gap will be wider. The band gap width of the sample prepared by ball milling method is 2.3 eV, and the blue shift effect is more obvious.</p><p>As <xref ref-type="fig" rid="fig3">Figure 3</xref> shows, the absorption peaks of the samples were 484.6 nm and 487.2 nm respectively, which were basically around 485 nm. The reason for the absorption peaks was typical 0-dimensional [Bi2I9]<sup>3−</sup> bioctahedral quantum confinement effect, and the corresponding band width was about 2.55 eV [<xref ref-type="bibr" rid="scirp.117219-ref21">21</xref>], which proved that the band gap width of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> polycrystals obtained was also close to the theoretical value At the same time, the transmittance shows that the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> absorbs the red light about 540 nm very obviously, which further confirms</p><p>the experimental feasibility of the method for the synthesis of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> polycrystals.</p><p>3) TG-DTA</p><p>Thermal analysis technology is that when the physical or chemical states of substances change (such as melting, sublimation, dehydration and polymerization, etc.), thermodynamic properties (specific heat, enthalpy and thermal conductivity, etc.) often change, so the physical and chemical change process of substances can be understood by measuring the change of their thermodynamic properties [<xref ref-type="bibr" rid="scirp.117219-ref22">22</xref>]. The thermogram (DTA curve) obtained by DTA is the temperature as the abscissa and the temperature difference between the sample and reference ΔT as the ordinate, and the different endothermic and exothermic peaks show the different thermal transition states of the sample when heated.</p><p>The thermal stability of the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> is confirmed by thermogravimetric analysis (<xref ref-type="fig" rid="fig4">Figure 4</xref>), showing no detectable mass loss until 500˚C, confirming good thermal stability of ASP-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub>. As contrast HBEM-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> were beginning to decompose at 300˚C. It can be clearly seen that the sample prepared by ball milling has decomposition below 400˚C, while the polycrystalline powder obtained by anti-solvent method starts to decompose at 500˚C and above. Among them, Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> (Purple curve) prepared by ball milling method does not decompose before 300, and it shows three decomposition steps from 100˚C to 700˚C, corresponding to mass loss of about 70%, 20% and 10% respectively. The temperature of the second step is very close to that of the first step of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub>. The peak value of the first-order differential curve in <xref ref-type="fig" rid="fig4">Figure 4</xref>(b) is 370.3˚C, the sample in <xref ref-type="fig" rid="fig4">Figure 4</xref>(a) corresponds to the sample in <xref ref-type="fig" rid="fig2">Figure 2</xref>(a). It can be seen that the crystallization is good, the melting decomposition temperature is relatively higher, and the maximum decomposition rate is 564˚C. The whole TAG curve is very consistent with the reported single crystal TAG curve [<xref ref-type="bibr" rid="scirp.117219-ref13">13</xref>].</p><p>4) SEM</p><p>SEM was used to characterize its micro-structure, in order to observe the properties of powder more directly such as crystallization.</p><p>The results obtained from XRD test analysis of the material mentioned above can be explicitly guided. In fact, the crystallization of powder obtained by ASP method is far better than that prepared by HEBM, which is also confirmed by SEM characterization analysis. According to <xref ref-type="fig" rid="fig5">Figure 5</xref>, it can be clearly observed that ASP powder and HEBM powder have larger crystal particles and better crystallinity under a scanning electron microscope with a magnification of 2000 times at 5 μm.</p><p>By observing the cross section and surface flatness of the thin section by SEM (<xref ref-type="fig" rid="fig6">Figure 6</xref>), it was found that although the surface flatness of sample A was worse than that of sample B, the overall density of the material reflected by the cross section seemed to be stronger than that of A. However, it can be easily seen from the SEM figure of cross section that its crystallinity is much stronger than that of sample B, and its grain size is similar to that of powder SEM, which is much larger than that of sample B.</p></sec><sec id="s3_2"><title>3.2. Device Performance of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> Wafer Direct X-Ray Detectors</title><p>The performance of devices is affected by many factors, and a lot of useful information has been obtained from the characterization of basic properties of materials. The electrical properties of the materials obtained in the 2 method were characterized. The I-V characteristics and dark current curve were obtained by the semiconductor parameter analyzer, and the dark resistivity and conductivity of the materials were calculated.</p><p>As we all know, in semiconductor physics, it is assumed that there are two kinds of carriers, electrons and holes, in semiconductor materials, and the relationship between the current density J and the electric field E can be expressed as [<xref ref-type="bibr" rid="scirp.117219-ref23">23</xref>]</p><p>J = σ E = ( n q μ n + p q μ p ) | E | (3-1)</p><p>where σ represents the conductivity of the material, is the reciprocal of the resistivity, n, p respectively represents the number of electronic holes in the semiconductor, q represents the unit charge, and μ<sub>n</sub>, μ<sub>p</sub> represents the mobility of electrons and holes. According to Equation (4-1), the conductivity of the material can be obtained by taking the derivative of J with respect to E, in unit of W<sup>−1</sup>&#215;cm<sup>−1</sup>.</p><p>As <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) shows, in the electric field intensity range of −30 Vmm<sup>−1</sup> to 30 Vmm<sup>−1</sup>, the current density J and the electric field intensity E show a linear relationship, and the ASP-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> poly-crystalline wafer shows a smaller current density under the same electric field intensity, that is to say, the resistance value of the sample is greater than that of the HEBM-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> sample. The conductivity of the photosensitive element prepared by the two methods is 1.95 &#215; 10<sup>−10</sup> W<sup>−1</sup>∙cm<sup>−1</sup> and 4.53 &#215; 10<sup>−11</sup> W<sup>−11</sup>∙cm<sup>−1</sup>, respectively.</p><p>The test data is not stable enough when the bias voltage is just added to both</p><p>ends of the device, so the analysis of dark conductance data starts from 20 s. <xref ref-type="fig" rid="fig7">Figure 7</xref>(b) shows the devices prepared by two methods. When the applied voltage is 15V, the mean dark current of ASP-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> is about 2.01 &#215; 10<sup>−11</sup> A, while the dark current of HEBM-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> is about 4.1 &#215; 10<sup>−10</sup> A, which also shows that the former has higher resistivity.</p><p>As illustrated in <xref ref-type="fig" rid="fig8">Figure 8</xref>(a), compared with Cs<sub>2</sub>AgBiBr<sub>6</sub>, CdTe, MA<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub>, MAPbiI<sub>3</sub>, Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> exhibited higher absorption coefficient, especially for X-ray photons of 36 - 90 keV, which indicates its potential in medical radiography X-ray detection. As for <xref ref-type="fig" rid="fig8">Figure 8</xref>(b), it shows the absorption coefficient corresponding to different materials mentioned above. <xref ref-type="fig" rid="fig8">Figure 8</xref>(c) shows the relationship between absorption coefficient of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> material and material thickness, in this way, the absorption efficiency of the sheet material at its current thickness can be easily calculated. The two wafer thicknesses obtained in this work are 589 nm and 535 nm respectively; this means an X-ray absorption efficiency of 100% for 35 KeV. The absorption coefficient datum comes from the NIST database [<xref ref-type="bibr" rid="scirp.117219-ref24">24</xref>].</p><p>Sensitivity is a key parameter to characterize the detection efficiency of photodetector. The detection sensitivity S<sub>x</sub> of X-ray detector is defined as [<xref ref-type="bibr" rid="scirp.117219-ref25">25</xref>]:</p><p>S x = Q A X (3-2)</p><p>where, A represents the effective irradiation area, in cm<sup>2</sup>; X represents radiation dose, in unit of G<sub>y</sub>; Q is the effective net charge collected by the detector material under X-ray irradiation, which can be expressed as [<xref ref-type="bibr" rid="scirp.117219-ref26">26</xref>]:</p><p>Q = ∫ I &#175; photo ( t ) d t (3-3)</p><p>where, represents the average photocurrent, and t represents the effective sampling</p><p>time of the detector; According to Equations (3-2) and (3-3), the sensitivity of the detector can be obtained.</p><p>The ratio of detector effective signal to noise signal is signal-to-noise ratio (SNR), which is one another of the key parameters to evaluate the overall performance of detector [<xref ref-type="bibr" rid="scirp.117219-ref27">27</xref>]. SNR for X-ray imaging devices is expressed as the ratio of device signal current to noise current, namely [<xref ref-type="bibr" rid="scirp.117219-ref20">20</xref>]:</p><p>SNR = I singal I noise (3-4)</p><p>I singal = I &#175; photo − I &#175; dark (3-5)</p><p>I noise = 1 N ∑ i N ( I i − I &#175; photo ) 2 (3-6)</p><p>where I<sub>signal</sub> is the optical gain, that is, the mean difference between photocurrent and dark current, Ī<sub>dark</sub> represents the average dark current, Ī<sub>photo</sub> represents the average photocurrent, and I<sub>noise</sub> is the standard deviation of the photocurrent of the detector.</p><p>As shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>, different radiation dose rates (7.6 μGyS<sup>−</sup><sup>1</sup> - 396 μGyS<sup>−</sup><sup>1</sup>)</p><p>were measured respectively. The J-E curve of the detector was obtained by the preparation of polycrystalline powder by HEBM and ASP, and the optical gain of the device was visualized under different irradiation intensiities. The slope of the J-E curve, in general, and the device linearity are both good, contrast in the section on the dark conductivity, two kinds of method, the resistivity of ASP sample is greater than HEBM sample material, and the former under X-ray irradiation of photocurrent density larger instead, which further confirmed the samples prepared by the solvent method for better crystallization properties, thus gain more light. The density of J-E curve can directly reflect the size of gain. The denser (blue curves) means the increase of the same irradiation measure, the smaller the optical gain is, and vice versa (red curves).</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>0(a) shows the device response diagram prepared by the two methods at 2 s irradiation switch, 15 V bias voltage and 315.5 μGyS<sup>−</sup><sup>1</sup> dose rate. It can be clearly seen that the response signal current of black curve (ASP) is greater than that of red curve (HEBM), while the photocurrent of the latter shows a very obvious noise signal (curve burr). Combined with the performance characterization of materials prepared by the two methods described above, the reason for the poor response performance of HEBM-Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> detector is still that the crystallization performance of core layer material is lower, and the probability of recombination of carriers in the material body is higher, showing stronger noise signal. <xref ref-type="fig" rid="fig1">Figure 1</xref>0(b) and <xref ref-type="fig" rid="fig1">Figure 1</xref>0(c) show that under the same test bias light measured by conductivity with the increase of irradiation dose rate increased significantly, consistent with the J-E Bright field test results, photocurrent increased with the increase of irradiation dose rate ladder type at the same time also presents the ladder type growth obviously, and irradiation dose rate according to the linear increase response between current linear fitting are also presents linear basically. The response linearity of the device is high.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Important factors have been reported and compared with this work</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Material</th><th align="center" valign="middle" >Sensitivity (uC∙Gy<sub>air</sub>s<sup>−1</sup>)</th><th align="center" valign="middle" >LoD (nGy<sub>air</sub>s<sup>−1</sup>)</th><th align="center" valign="middle" >Electric field(Vmm<sup>−1</sup>)</th><th align="center" valign="middle" >SNR</th><th align="center" valign="middle" >type</th><th align="center" valign="middle" >Ref.</th></tr></thead><tr><td align="center" valign="middle" >Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >588</td><td align="center" valign="middle" >76</td><td align="center" valign="middle" >28.8</td><td align="center" valign="middle" >179</td><td align="center" valign="middle" >Poly-crystal</td><td align="center" valign="middle" >ASP</td></tr><tr><td align="center" valign="middle" >Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >543</td><td align="center" valign="middle" >155</td><td align="center" valign="middle" >28.8</td><td align="center" valign="middle" >65</td><td align="center" valign="middle" >Poly-crystal</td><td align="center" valign="middle" >HBEM</td></tr><tr><td align="center" valign="middle" >Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >1652</td><td align="center" valign="middle" >130</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >16.9</td><td align="center" valign="middle" >Single-crystal</td><td align="center" valign="middle" >[<xref ref-type="bibr" rid="scirp.117219-ref13">13</xref>]</td></tr><tr><td align="center" valign="middle" >Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >111.9</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >45</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >Single-crystal</td><td align="center" valign="middle" >[<xref ref-type="bibr" rid="scirp.117219-ref14">14</xref>]</td></tr><tr><td align="center" valign="middle" >Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >964</td><td align="center" valign="middle" >44.6</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >66</td><td align="center" valign="middle" >Single-crystal</td><td align="center" valign="middle" >[<xref ref-type="bibr" rid="scirp.117219-ref20">20</xref>]</td></tr><tr><td align="center" valign="middle" >MA<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub></td><td align="center" valign="middle" >872</td><td align="center" valign="middle" >31</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >35.6</td><td align="center" valign="middle" >Single-crystal</td><td align="center" valign="middle" >[<xref ref-type="bibr" rid="scirp.117219-ref15">15</xref>]</td></tr><tr><td align="center" valign="middle" >α-Se</td><td align="center" valign="middle" >440</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >Amorphous</td><td align="center" valign="middle" >[<xref ref-type="bibr" rid="scirp.117219-ref28">28</xref>]</td></tr></tbody></table></table-wrap></sec></sec><sec id="s4"><title>4. Conclusions</title><p>In this paper, two methods of anti-solvent and ball milling were used to synthesize Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub>. In addition, the basic properties of the materials were tested and analyzed, and it was found that ASP method had better crystallinity. Although HBEM's crystallinity was not good enough, it was better than the crystal uniformity, which made the wager surface smoother and more conducive to obtaining good ohmic contact. The X-ray detector was fabricated by pressing polycrystalline powders obtained from two methods mentioned above.</p><p>When testing and analyzing the electrical properties of 2 types of materials, it is found that the resistivity of ASP material is significantly higher than that of HBEM, which is also the reason why the former has lower dark current under the same electric field intensity, which is conducive to signal discrimination of the device. Finally, the response performance was analyzed for 2 devices, and important device parameters including SNR and sensitivity were obtained. In order to more conveniently explain the advantages and disadvantages of this working device, some typical device parameter pairs are selected to report, for example, see <xref ref-type="table" rid="table1">Table 1</xref>.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The author declares no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s6"><title>Cite this paper</title><p>Zhang, C.X. (2022) Direct Conversion X-Ray Detectors with High Sensitivity at Low Dose Rate Based on All-Inorganic Lead-Free Perovskite Wafers. Detection, 9, 13-27. https://doi.org/10.4236/detection.2022.92002</p></sec></body><back><ref-list><title>References</title><ref id="scirp.117219-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, H., Chen, Q., Li, G., et al. (2014) Photovoltaics. Interface Engineering of Highly Efficient Perovskite Solar Cells. Science, 345, 542-546. https://doi.org/10.1126/science.1254050</mixed-citation></ref><ref id="scirp.117219-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Green, M.A., Ho-Baillie, A. and Snaith, H.J. (2014) The Emergence of Perovskite Solar Cells. Nature Photonics, 8, 506-514. https://doi.org/10.1038/nphoton.2014.134</mixed-citation></ref><ref id="scirp.117219-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Yang, W.S., et al. (2017) Iodide Management in Formamidinium-Lead-Halide-Based Perovskite Layers for Efficient Solar Cells. Science, 356, 1376-1379.</mixed-citation></ref><ref id="scirp.117219-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Xu, W., Hu, Q., Bai, S., et al. (2019) Rational Molecular Passivation for High-Performance Perovskite Light-Emitting Diodes. Nature Photonics, 13, 418-424. https://doi.org/10.1038/s41566-019-0390-x</mixed-citation></ref><ref id="scirp.117219-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Sakdinawat, A. and Attwood, D. (2009) Nanoscale X-Ray Imaging. Nature Photonics, 4, 840-848. https://doi.org/10.1038/nphoton.2010.267</mixed-citation></ref><ref id="scirp.117219-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Chen, Q., Wu, J., Ou, X., et al. (2018) All-Inorganic Perovskite Nanocrystal Scintillators. Nature, 561, 88-93. https://doi.org/10.1038/s41586-018-0451-1</mixed-citation></ref><ref id="scirp.117219-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Heiss, W. and Brabec, C. (2016) X-Ray Imaging: Perovskites Target X-Ray Detection. Nature Photonics, 10, 288-289. https://doi.org/10.1038/nphoton.2016.54</mixed-citation></ref><ref id="scirp.117219-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Yakunin, S., et al. (2015) Detection of X-Ray Photons by Solution-Processed Lead Halide Perovskites. Nature Photonics, 9, 444–449. https://doi.org/10.1038/nphoton.2015.82</mixed-citation></ref><ref id="scirp.117219-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Kim, Y.C., Kim, K.H., Son, D.Y., et al. (2017) Printable Organometallic Perovskite Enables Large-Area, Low-Dose X-Ray Imaging. Nature, 550, 87-91. https://doi.org/10.1038/nature24032</mixed-citation></ref><ref id="scirp.117219-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Basiricò, L., Ciavatti, A. and Fraboni, B. (2020) Solution-Grown Organic and Perovskite X-Ray Detectors: A New Paradigm for the Direct Detection of Ionizing Radiation. Advanced Materials Technologies, 6, Article ID: 2000475. https://doi.org/10.1002/admt.202000475</mixed-citation></ref><ref id="scirp.117219-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Armaroli, G., Ferlauto, L., Lédée, F., et al. (2021) X-Ray-Induced Modification of the Photophysical Properties of MAPbBr3 Single Crystals. ACS Applied Materials &amp; Interfaces, 13, 58301-58308. https://doi.org/10.1021/acsami.1c16072</mixed-citation></ref><ref id="scirp.117219-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">He, Y., Hadar, I. and Kanatzidis, M.G. (2021) Detecting Ionizing Radiation Using Halide Perovskite Semiconductors Processed through Solution and Alternative Methods. Nature Photonics, 16, 14-26.</mixed-citation></ref><ref id="scirp.117219-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Y., Liu, Y., Xu, Z., et al. (2020) Nucleation-Controlled Growth of Superior Lead-Free Perovskite Cs3Bi2I9 Single-Crystals for High-Performance X-Ray Detection. Nature Communications, 11, Article No. 2304. https://doi.org/10.1038/s41467-020-16034-w</mixed-citation></ref><ref id="scirp.117219-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Sun, Q., Xu, Y., Zhang, H., et al. (2018) Optical and Electronic Anisotropies in Perovskite Crystals of Cs3Bi2I9 Studies of Nuclear Radiation Detection. Journal of Materials Chemistry A, 6, 23388-23395. https://doi.org/10.1039/C8TA09525F</mixed-citation></ref><ref id="scirp.117219-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Y.C., Zhang, Y.X., Zhou, Y., et al. (2020) Large Lead-Free Perovskite Single Crystal for High-Performance Coplanar X-Ray Imaging Applications. Advanced Optical Materials, 8, Article ID: 2000814. https://doi.org/10.1002/adom.202000814</mixed-citation></ref><ref id="scirp.117219-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Wang, Z., Sun, R., Liu, N., et al. (2021) X-Ray Imager of 26-m Resolution Achieved by Perovskite Assembly. Nano Research, 15, 2399-2404. https://doi.org/10.1007/s12274-021-3808-y</mixed-citation></ref><ref id="scirp.117219-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, H., Yang, Z., Zhou, M., et al. (2021) Reproducible X-Ray Imaging with a Perovskite Nanocrystal Scintillator Embedded in a Transparent Amorphous Network Structure. Advanced Materials, 33, Article ID: 2102529. https://doi.org/10.1002/adma.202102529</mixed-citation></ref><ref id="scirp.117219-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Zheng, J., Zeng, Y., Wang, J., et al. (2021) Hydrogen-Rich 2D Halide Perovskite Scintillators for Fast Neutron Radiography. Journal of the American Chemical Society, 143, 21302-21311. https://doi.org/10.1021/jacs.1c08923</mixed-citation></ref><ref id="scirp.117219-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, H., Xu, Y., Sun, Q., et al. (2018) Lead Free Halide Perovskite Cs3Bi2I9 Bulk Crystals Grown by a Low Temperature Solution Method. CrystEngComm, 20, 4935-4941. https://doi.org/10.1039/C8CE00925B</mixed-citation></ref><ref id="scirp.117219-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Wei, S., Tie, S., Shen, K., et al. (2021) High-Performance X-Ray Detector Based on Liquid Diffused Separation Induced Cs3Bi2I9 Single Crystal. Advanced Optical Materials, 9, Article ID: 2101351. https://doi.org/10.1002/adom.202101351</mixed-citation></ref><ref id="scirp.117219-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Kawai, T. and Shimanuki, S. (1993) Optical Studies of (CH3NH3)3Bi2I9 Single Crystals. Physica Status Solidi (b), 177, K43-K45. https://doi.org/10.1002/pssb.2221770128</mixed-citation></ref><ref id="scirp.117219-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Pagoria, P.F., Lee, G.S., Mitchell, A.R., et al. (2002) A Review of Energetic Materials Synthesis. Thermochimica Acta, 384, 187-204. https://doi.org/10.1016/S0040-6031(01)00805-X</mixed-citation></ref><ref id="scirp.117219-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Dobson, P.J. (1982) Physics of Semiconductor Devices (2nd edn). Physics Bulletin, 33, 139. https://doi.org/10.1088/0031-9112/33/4/035</mixed-citation></ref><ref id="scirp.117219-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Berger, M.J., Hubbell, J.H., Seltzer, S.M., et al. (2013) XCOM: Photon Cross Sections Database: NIST Standard Reference Database 8. NIST. https://www.nist.gov/pml/xcom-photon-cross-sections-database</mixed-citation></ref><ref id="scirp.117219-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, X.H., Zhao, B.J., Zhu, S.F., et al. (2007) Growth of PbI2 Crystal with Excessive Pb and Its Characterization. Journal of Semiconductors, 28, 898.</mixed-citation></ref><ref id="scirp.117219-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Sun, H., Zhu, X.H., Yang, D.Y., Yang, J., Gao, X.Y. and Li, X. (2014) Morphological and Structural Evolution during Thermally Physical Vapor Phase Growth of PbI2 Polycrystalline Thin Films. Journal of Crystal Growth, 29, 34. https://doi.org/10.1016/j.jcrysgro.2014.07.043</mixed-citation></ref><ref id="scirp.117219-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Y., Zhang, Y.X., Zhu, X., et al. (2021) Triple-Cation and Mixed-Halide Perovskite Single Crystal for High-Performance X-Ray Imaging. Advanced Materials, 33, Article ID: 2006010. https://doi.org/10.1002/adma.202006010</mixed-citation></ref><ref id="scirp.117219-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Polischuk, B.T., Rougeot, H., Wong, K., et al. (1999) Direct Conversion Detector for Digital Mammography. Proceedings of SPIE—The International Society for Optical Engineering, 3659, 417-425.</mixed-citation></ref></ref-list></back></article>