<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AJAC</journal-id><journal-title-group><journal-title>American Journal of Analytical Chemistry</journal-title></journal-title-group><issn pub-type="epub">2156-8251</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ajac.2022.132004</article-id><article-id pub-id-type="publisher-id">AJAC-115537</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Optimization of High-Performance Liquid Chromatography Parameters for Purification of Oligonucleotide-A
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Christina</surname><given-names>Perez</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mubeen</surname><given-names>Rani</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tuan</surname><given-names>Phan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Chemistry, Texas Southern University, Houston, USA</addr-line></aff><pub-date pub-type="epub"><day>15</day><month>02</month><year>2022</year></pub-date><volume>13</volume><issue>02</issue><fpage>39</fpage><lpage>50</lpage><history><date date-type="received"><day>26,</day>	<month>October</month>	<year>2021</year></date><date date-type="rev-recd"><day>25,</day>	<month>February</month>	<year>2022</year>	</date><date date-type="accepted"><day>28,</day>	<month>February</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The modification of high-performance liquid chromatography parameters leads to a more effective oligonucleotide-A purification process. Using various experimental parameters such as buffer, concentration, and pH, a method for optimizing the purification of an oligonucleotide-A on a reverse-phase C18 column was created. To purify oligonucleotide-A, High-Performance Liquid Chromatography (HPLC), Ultraviolet-Visible Spectrophotometry (UV-Vis), Liquid Chromatography-Mass Spectrometry (LC-MS), and lyophilization were used. Chromatographic data were collected with a semi-prep HPLC system, quantified with the UV-Vis technique, and validated with the LC-MS method. The most optimized parameters found to obtain the purity of 93.0% are 40 mM triethylammonium bicarbonate (TEAB) buffer with pH 7, which is approximately 6.0% higher than the reported method of which the purity is 87.0%. However, the yield under these conditions was reduced by about 5%. The worst possible optimized settings that resulted in the lowest purity (84.0%) and yield (69.0%) are 10 mM ammonium acetate (NH
  <sub>4</sub>CH
  <sub>3</sub>CO
  <sub>2</sub>) with pH 7.
 
</p></abstract><kwd-group><kwd>Purification</kwd><kwd> High-Performance Liquid Chromatography</kwd><kwd> Oligonucleotide-A</kwd><kwd> Dipotassium Phosphate</kwd><kwd> Triethylammonium Acetate</kwd><kwd> Triethylammonium Bicarbonate</kwd><kwd> Ammonium Acetate</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Synthetic oligonucleotides have evolved into important biomolecules with a wide range of applications. Purification and modification of synthetic oligonucleotides are critical technologies for a wide range of applications in the life sciences [<xref ref-type="bibr" rid="scirp.115537-ref1">1</xref>]. Synthetic oligonucleotides have been used in DNA sequencing as hybridization probes, linkers, and primers, as well as in amplification procedures and antisense therapies [<xref ref-type="bibr" rid="scirp.115537-ref2">2</xref>]. One of the most serious issues with synthetic oligonucleotides is impurity, which can result from poor synthesis, de-protected products, short sequences, and/or changed sequences [<xref ref-type="bibr" rid="scirp.115537-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.115537-ref4">4</xref>]. These contaminants can jeopardize an experiment or assay in some cases by competing with full-length products or inhibiting reactions [<xref ref-type="bibr" rid="scirp.115537-ref5">5</xref>].</p><p>Oligonucleotide purification approaches (optimizing pH, concentration, mobile phase, and chain) have been developed to increasing functionalization in a variety of genomic assays and pharmacological treatments [<xref ref-type="bibr" rid="scirp.115537-ref6">6</xref>]. The most common purification processes are Thin-Layer Chromatography (TLC), purification cartridges, Polyacrylamide Gel Electrophoresis (PAGE) gels, desalting, and High-Performance Liquid Chromatography (HPLC). As laboratories strive for greater efficiency, a focus on increasing yields and shortening purification times has grown in importance [<xref ref-type="bibr" rid="scirp.115537-ref7">7</xref>]. Several parameters, including the application, oligonucleotide length, and oligonucleotide alterations, determine the best approach [<xref ref-type="bibr" rid="scirp.115537-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.115537-ref9">9</xref>]. HPLC is one of the purification methods that can be used on a large scale to separate oligonucleotides. Among the many HPLC procedures available are Reverse-Phase (RP), Normal-Phase (NP), Hydrophilic Interaction (HI), Ion-Exchange (IE), and Size-Exclusion (SE). All of these strategies apply to the stationary phase of the system.</p><p>To fully comprehend the retention mechanism influencing a separation, the chemistry of the bonded phase, the nature of the silica surface treatment, and the surface accessibility must all be considered and classified, which will then influence the initial column selection or method optimization [<xref ref-type="bibr" rid="scirp.115537-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.115537-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.115537-ref12">12</xref>]. HPLC parameters have an effect on the chromatogram, which is the final product of the HPLC experiment. The detector response is a time-dependent function of the chromatogram [<xref ref-type="bibr" rid="scirp.115537-ref13">13</xref>]. In HPLC, the resolution of the chromatogram is the most important factor. The goal is to achieve the best possible resolution in the shortest possible time. A resolution of 1.5 or higher ensures that the sample components are well separated enough to determine the area under the curve correctly [<xref ref-type="bibr" rid="scirp.115537-ref14">14</xref>].</p><p>When developing HPLC procedures, the first approach frequently fails to separate key components of a mixture. To achieve the required separations, the mobile phase, stationary phase, and column temperature can all be adjusted [<xref ref-type="bibr" rid="scirp.115537-ref15">15</xref>]. Changing the particle size of the column is another useful parameter. Greater plate numbers are produced by smaller particle sizes, resulting in sharper peaks and the ability to resolve closely eluting peaks [<xref ref-type="bibr" rid="scirp.115537-ref16">16</xref>]. Some components, such as proteins and oligonucleotides, may be difficult to separate on smaller columns but can be resolved fast on a larger column [<xref ref-type="bibr" rid="scirp.115537-ref17">17</xref>]. Other factors that determine chromatogram resolution include selectivity, efficiency, and retention, which are regulated by HLPC parameters (solvent strength, pH, column material, and temperature) [<xref ref-type="bibr" rid="scirp.115537-ref18">18</xref>].</p><p>This paper provides a thorough assessment of oligonucleotide-A purification in terms of purity and yield. HPLC parameters such as buffer, concentration, and pH were used to find the best purification procedure.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Materials</title><p>The sample in all separation experiments was a 30-mer oligonucleotide-A. The crude oligonucleotide-A obtained from IDT (USA) had a molecular weight of 9513. Reagent grade 1 M Tris HCl, acetonitrile, phosphate-buffered saline (PBS), and NaCl were supplied by VWR (USA). The on-site MilliQ system provided deionized water for the research (NANOPure). The chromatography stationary phase for the initial research was a Dionex DNAPac PA200 oligonucleotide column (4 &#215; 250 mm). Before purification, all samples were examined on an Agilent 1260 analytical HPLC system. A 500 nmol of stock oligonucleotide-A was diluted to 1 mM in 10&#215; PBS. To attain incoming purity, one nanomole of oligonucleotide-A was run on the PA200 column. After running the sample through the HPLC system, a mass was recorded using an Agilent 6100 series SQ system to confirm the product. The initial parameters in <xref ref-type="table" rid="table1">Table 1</xref> show the analysis method used to record initial purity. The purity was documented, and the sample was readied for purification.</p></sec><sec id="s2_2"><title>2.2. Initial Control</title><p>The preparative chromatographic studies were carried out on a ChemStation Work Station that was linked to an Agilent 1260 semi-prep HPLC system equipped with a diode array detector. <xref ref-type="table" rid="table2">Table 2</xref> shows the experimental parameters that are being modified and tested. Each variant change was tested three times, with the given result being the average of the three runs. The first stage in the optimization process was to replicate the results provided in the literature, which showed that HPLC employing potassium phosphate buffer at pH 7 and acetonitrile yielded 88.0% purity and 80.00% recovery [<xref ref-type="bibr" rid="scirp.115537-ref1">1</xref>]. For peaks greater than 300 mAU, a shallow gradient was applied to an XTERRA C18 column (19 &#215; 100 mm), and fraction collection was utilized.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Initial IEC analysis gradient</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Time, min</th><th align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub>%: 100 mM Tris HCl + 25% Acetontrile</th><th align="center" valign="middle" >TEAB %: 100 mM Tris HCl + 25% Acetonitrile + 1.25 M NaCl</th></tr></thead><tr><td align="center" valign="middle" >0</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >30</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >50</td></tr><tr><td align="center" valign="middle" >31</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >50</td></tr><tr><td align="center" valign="middle" >33</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >36</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >0</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Testing parameters for each experiment</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Constant</th><th align="center" valign="middle" >Constant</th><th align="center" valign="middle" >Variant</th><th align="center" valign="middle" >Variant</th><th align="center" valign="middle" >Variant</th><th align="center" valign="middle" >Variant</th><th align="center" valign="middle" >Variant</th></tr></thead><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10 mM</td><td align="center" valign="middle" >pH 5</td><td align="center" valign="middle" >pH 6</td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >pH 8</td><td align="center" valign="middle" >pH 9</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20 mM</td><td align="center" valign="middle" >pH 5</td><td align="center" valign="middle" >pH 6</td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >pH 8</td><td align="center" valign="middle" >pH 9</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40 mM</td><td align="center" valign="middle" >pH 5</td><td align="center" valign="middle" >pH 6</td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >pH 8</td><td align="center" valign="middle" >pH 9</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >1 mM</td><td align="center" valign="middle" >10 mM</td><td align="center" valign="middle" >20 mM</td><td align="center" valign="middle" >30 mM</td><td align="center" valign="middle" >40 mM</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>PO<sub>4</sub></td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >1 mM</td><td align="center" valign="middle" >10 mM</td><td align="center" valign="middle" >20 mM</td><td align="center" valign="middle" >30 mM</td><td align="center" valign="middle" >40 mM</td></tr><tr><td align="center" valign="middle" >10 mM</td><td align="center" valign="middle" >pH 7</td><td align="center" valign="middle" >K<sub>2</sub>PO<sub>4</sub></td><td align="center" valign="middle" >TEAA</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >pH 7, 40 mM</td><td align="center" valign="middle" >Oligo-20</td><td align="center" valign="middle" >Oligo-25</td><td align="center" valign="middle" >Oligo-30</td><td align="center" valign="middle" >Oligo-35</td><td align="center" valign="middle" >Oligo-40</td></tr></tbody></table></table-wrap><p>Note: Each variant was run three times, the average of the three is reported in this work.</p></sec><sec id="s2_3"><title>2.3. Rotary Evaporation</title><p>In-process samples from potassium phosphate buffer preparative runs at pH 5 to 9 were kept in the refrigerator at 4˚C. After that, the samples were concentrated using a Heidolph Precision rotary evaporator. The bath temperature was set at 30˚C, and the rotation speed was set to 100 rpm. The pressure was manually controlled, and it took roughly 75 minutes for one sample to evaporate from 40 mL to 2 mL.</p></sec><sec id="s2_4"><title>2.4. Lyophilization</title><p>A FreeZone Freeze Dry System was used to lyophilize the material. The leftover sample is frozen using dry ice and isopropanol alcohol after each sample has been evaporated close to dryness, 2 mL. This procedure takes approximately 5 minutes. The sample is placed on the Freeze Dry System overnight when it has totally frozen. The material was returned to powder form the following morning. After that, the sample is reconstituted in 10&#215; PBS buffer.</p></sec><sec id="s2_5"><title>2.5. Quantification Using Spectrophotometer</title><p>After the material has been restored to liquid form, it is quantified. The quantification is done using a Biotek Synergy H1 spectrophotometer with the extinction coefficient of the oligonucleotide-A provided by IDT. The coefficient of extinction was 363,400∙M<sup>−1</sup>∙cm<sup>−1</sup>. The following calculation was used to determine concentration:</p><p>Concentration in uM = ( ( Absorbance * Dilution Factor Extinction . Coefficient ) / t ) * 1, 000 , 000</p></sec><sec id="s2_6"><title>2.6. Reanalysis</title><p>The final step in the procedure is reanalysis on an Agilent 1260 analytical HPLC system and verification on an Agilent 6100 Series SQ LC/MS system.</p></sec></sec><sec id="s3"><title>3. Result and Discussion</title><p><xref ref-type="table" rid="table2">Table 2</xref> shows the experiment designed to investigate this work. Buffer type, buffer concentration, and buffer pH are factors that affecting the purification of oligonucleotide-A. Keeping two factors constant and changing either buffer type, buffer concentration, or buffer pH, purity and yield were determined.</p><sec id="s3_1"><title>3.1. pH Optimization</title><p><xref ref-type="table" rid="table3">Table 3</xref> lists all % purity values and yields with different pH values (5 to 9) at constant 10 mM K<sub>2</sub>HPO<sub>4</sub>, 20 mM K<sub>2</sub>HPO<sub>4</sub>, and 40 mM TEAB. <xref ref-type="fig" rid="fig1">Figure 1</xref>(a) compares the percent purity and yield of K<sub>2</sub>HPO<sub>4</sub> at 10 mM, <xref ref-type="fig" rid="fig1">Figure 1</xref>(b) for K<sub>2</sub>HPO<sub>4</sub> at 20 mM, and <xref ref-type="fig" rid="fig1">Figure 1</xref>(c) for TEAB at 40 mM, with pH values ranging from 5 to 9.</p><p>When the concentration of K<sub>2</sub>HPO<sub>4</sub> was kept constant at 10 mM and pH 7, the purity was 87.5% and the yield was 79.0%, which stayed at the optimum level. However, lowering the pH results in a decrease in purity and yield. The purity of the sample was 86.0% at pH 6 and 85.9% at pH 5, with yields of 78.8% and 78.0%. This value is 1% - 2% lower than pH 7. The purity was 86.9% and 87.0%, respectively, and the yield was 79.1% and 78.9% at higher pH 8 and 9 but did not produce a greater purity and yield at this pH.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Comparison of purity and yield with different pH values for Oligonucleotide-A at constant 10 mM and 20 mM concentrations of K<sub>2</sub>HPO<sub>4</sub> and constant 40 mM concentration of TEAB with pH ranging from 5 to 9</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >Buffer</th><th align="center" valign="middle" >Concentration, mM</th><th align="center" valign="middle" >Purity, %</th><th align="center" valign="middle" >Yield, %</th></tr></thead><tr><td align="center" valign="middle"  rowspan="3"  >5</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >85.9 &#177; 0.2</td><td align="center" valign="middle" >78.0</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >86.3 &#177; 0.2</td><td align="center" valign="middle" >78.1</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.0 &#177; 0.3</td><td align="center" valign="middle" >75.1</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >6</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >86.0 &#177; 0.1</td><td align="center" valign="middle" >78.8</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >86.7 &#177; 0.2</td><td align="center" valign="middle" >77.9</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.7 &#177; 0.3</td><td align="center" valign="middle" >75.7</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >7</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >87.5 &#177; 0.5</td><td align="center" valign="middle" >79.0</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >87.7 &#177; 0.2</td><td align="center" valign="middle" >77.9</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.9 &#177; 0.1</td><td align="center" valign="middle" >74.5</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >8</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >86.9 &#177; 0.3</td><td align="center" valign="middle" >79.1</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >87.4 &#177; 0.3</td><td align="center" valign="middle" >77.8</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.3 &#177; 0.1</td><td align="center" valign="middle" >74.5</td></tr><tr><td align="center" valign="middle"  rowspan="3"  >9</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >87.0 &#177; 0.1</td><td align="center" valign="middle" >78.9</td></tr><tr><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >87.3 &#177; 0.1</td><td align="center" valign="middle" >77.5</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.1 &#177; 0.1</td><td align="center" valign="middle" >74.1</td></tr></tbody></table></table-wrap><p>Note: Each value is obtained based on the average of three runs.</p><p>Changing the concentration of K<sub>2</sub>HPO<sub>4</sub> from 10 to 20 mM and then varying the pH from 5 to 9 resulted in no improvement in oligonucleotide-A purification at a constant 20 mM concentration of K<sub>2</sub>HPO<sub>4</sub>. The pH 7 sustained optimum values reveal the same purity and yield as 10mM in the previous method as 87.7% and 77.9%, respectively. The overall purity at pH 6 and 5 was 86.7% and 86.3%, respectively, in the experiment, although the overall yield was 77.9% and 78.1%.</p><p>Yield was shown to decrease by 1.6 percent when the pH climbed from pH 5 to pH 9. The purity of oligonucleotide-A increased by 0.2 percent at 20 mM concentration and pH 7 compared to 10 mM concentration and pH 7. Yield, on the other hand, fell by 0.5 percent.</p><p>When the dipotassium phosphate buffer pH variation was compared, the results from the 20 mM concentration studies were all slightly higher than the results from the 10 mM concentration experiments. There was a 0.2% - 0.7% higher in purity at 20 mM K<sub>2</sub>HPO<sub>4</sub> across pH 5 - pH 9. However, increased K<sub>2</sub>HPO<sub>4</sub> concentrations resulted in a 0.2% - 1.4% decline in output.</p><p>When the buffer was changed from K<sub>2</sub>HPO<sub>4</sub> to TEAB at 40 mM, the pH had a significant impact on the results. The purity and yield (93.3% and 74.5%, respectively) at pH 8 were equivalent to pH 9 (93.15% and 74.1%) at the same concentration; however, when compared to K<sub>2</sub>HPO<sub>4</sub> at 10 mM, the purity increased by 6.1% while the yield decreased by 4.8%. When compared to K<sub>2</sub>HPO<sub>4</sub> at 20 mM, the purity increased for TEAB at pH 8 and 9, but the yield was somewhat reduced.</p><p>When pH 5 and 6 were used with TEAB, the yields (93.0% for pH 5 and 93.7% for pH 6) were significantly higher (7.1 to 7.8%) than when pH 5 and 6 were used with K<sub>2</sub>HPO<sub>4</sub>. However, at the same pH levels, the yields were roughly 2.0% lower than with K<sub>2</sub>HPO<sub>4</sub>. TEAB at 40 mM and pH 7 produced the highest purity (93.9%); nonetheless, the percent yield is comparable to other pH values of the same buffer.</p><p>The standard deviation was calculated in these tests to quantify the amount of variation across all three trials at each pH level. All results were considered low, with the maximum standard deviation in the data set being 0.36 at pH 8 with 10 mM K<sub>2</sub>HPO<sub>4</sub>. The data set’s lowest standard deviation was 0.10, which was observed at pH 8 and pH 9.</p></sec><sec id="s3_2"><title>3.2. Concentration Optimizations</title><p>According to the data in <xref ref-type="table" rid="table3">Table 3</xref>, at pH 7, both buffers (K<sub>2</sub>HPO<sub>4</sub> and TEAB) produce the best outcomes when compared to the same concentration at other pH levels. This section explains the findings obtained when the buffer concentration varies from 1 to 40 mM while maintaining a constant pH of 7 (see <xref ref-type="table" rid="table4">Table 4</xref> and <xref ref-type="fig" rid="fig2">Figure 2</xref>). At 1 mM concentration, K<sub>2</sub>HPO<sub>4</sub> produced higher purity than TEAB (90.8% vs. 86.1%). TEAB, on the other hand, outperformed K<sub>2</sub>HPO<sub>4</sub> by 5.4% in yield. At 10 mM concentration, TEAB produced 5.1% more purity than K<sub>2</sub>HPO<sub>4</sub>; nevertheless, TEAB produced 4.1% less yield than K<sub>2</sub>HPO<sub>4</sub>. Buffer K<sub>2</sub>HPO<sub>4</sub> had around 5.1% less purity than TEAB at 20 mM concentration but had 2.8% higher yield. At 30 mM, TEAB has 6.0% higher purity than K<sub>2</sub>HPO<sub>4</sub> and just 0.6% lower yield. Buffer K<sub>2</sub>HPO<sub>4</sub> had 5.7% less purity than TEAB and 1.6% higher yield than TEAB at 40 mM. There were no significant variations in</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Comparison of purity and yield for Oligonucleotide-A with different concentration values at a constant pH of 7 for K<sub>2</sub>HPO<sub>4</sub> and TEAB</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >Concentration, mM</th><th align="center" valign="middle" >Buffer</th><th align="center" valign="middle" >Purity, %</th><th align="center" valign="middle" >Yield, %</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >7</td><td align="center" valign="middle"  rowspan="2"  >1</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >86.1 &#177; 0.9</td><td align="center" valign="middle" >79.8</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >90.8 &#177; 0.1</td><td align="center" valign="middle" >74.4</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >7</td><td align="center" valign="middle"  rowspan="2"  >10</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >87.5 &#177; 0.4</td><td align="center" valign="middle" >79.0</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >92.6 &#177; 0.1</td><td align="center" valign="middle" >74.9</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >7</td><td align="center" valign="middle"  rowspan="2"  >20</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >87.7 &#177; 0.3</td><td align="center" valign="middle" >77.9</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >92.6 &#177; 0.2</td><td align="center" valign="middle" >75.1</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >7</td><td align="center" valign="middle"  rowspan="2"  >30</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >87.1 &#177; 0.1</td><td align="center" valign="middle" >77.5</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >93.1 &#177; 0.1</td><td align="center" valign="middle" >74.9</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >7</td><td align="center" valign="middle"  rowspan="2"  >40</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >86.9 &#177; 0.2</td><td align="center" valign="middle" >76.1</td></tr><tr><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >93.3 &#177; 0.1</td><td align="center" valign="middle" >74.5</td></tr></tbody></table></table-wrap><p>Note: Each value is obtained based on the average of three runs.</p><p>purity or yield during pH tuning. However, increasing the concentration of K<sub>2</sub>HPO<sub>4</sub> and TEAB had a greater impact on purity and yield. The drop-in yield during the pH experiment was not as extreme as the concentration decrease, but the purity increased dramatically.</p><p>The standard deviation was calculated based on all three experiments at each concentration level to measure the degree of variation. All concentrations were considered modest, although the data set’s biggest standard deviation was at 1 mM K<sub>2</sub>HPO<sub>4</sub>. With a standard deviation of 0.96, this experiment had the largest standard deviation of all the experiments. The data set’s lowest standard deviation was 0.10, which was observed at 1 mM and 10 mM for TEAB.</p></sec><sec id="s3_3"><title>3.3. Mobile Phase Optimization</title><p>To optimize oligonucleotide-A purification, two additional buffers, TEAA and NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub>, were used in this study, and the experiment was performed at a constant pH of 7 and a constant concentration of 10 mM. The most change was generated by changing the nature of the buffer. <xref ref-type="table" rid="table5">Table 5</xref> and <xref ref-type="fig" rid="fig3">Figure 3</xref> show that TEAB had the highest purity at 92.6% (yield, 74.9%), followed by TEAA at 90.6% (yield, 72.1%), K<sub>2</sub>HPO<sub>4</sub> at 87.5% (yield, 79.0%), and NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub> at 84.3% (yield, 69.9%). According to the published literature [<xref ref-type="bibr" rid="scirp.115537-ref1">1</xref>], 88.0% purity and 80.0% yield were obtained by HPLC using K<sub>2</sub>HPO<sub>4</sub> buffer at pH 7 (10 mM), while in this experiment, K<sub>2</sub>HPO<sub>4</sub> purity was 87.5% and yield was 79.0%. There was a 5 -</p><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Comparison of purity and yield with different buffers at constant pH 7</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >Concentration, mM</th><th align="center" valign="middle" >Buffer</th><th align="center" valign="middle" >Purity, %</th><th align="center" valign="middle" >Yield, %</th></tr></thead><tr><td align="center" valign="middle" >7</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >K<sub>2</sub>HPO<sub>4</sub></td><td align="center" valign="middle" >87.5 &#177; 0.4</td><td align="center" valign="middle" >79.0</td></tr><tr><td align="center" valign="middle" >7</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >92.6 &#177; 0.1</td><td align="center" valign="middle" >74.9</td></tr><tr><td align="center" valign="middle" >7</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >TEAA</td><td align="center" valign="middle" >90.6 &#177; 0.</td><td align="center" valign="middle" >72.1</td></tr><tr><td align="center" valign="middle" >7</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub></td><td align="center" valign="middle" >84.3 &#177; 0.5</td><td align="center" valign="middle" >69.9</td></tr></tbody></table></table-wrap><p>Note: Each value is obtained based on the average of three runs.</p><p>6 percent higher from the earlier reported approach when TEAB was used instead of K<sub>2</sub>HPO<sub>4</sub>, and a 2.6 percent increase when TEAA was used instead of potassium phosphate. In all situations, the yield was reduced. The use of NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub> reduced yield by 10.1%. TEAA reduced production by 7.9%, TEAB by 5.1%, and potassium phosphate by 1%. TEAB has the highest purity and yield of the four buffers tested; the purity is 5.4% greater than previously reported data, but the yield is lower. TEAB has the largest concentration, followed by TEAA and NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub>.</p><p>The standard deviation for the mobile phase experiment change was recorded, and the findings are shown in <xref ref-type="table" rid="table5">Table 5</xref>. The data set’s largest standard deviation was 0.66 at 10 mM TEAA. The data set’s lowest standard deviation was 0.10, which was seen at 10 mM TEAB buffer.</p></sec><sec id="s3_4"><title>3.4. Optimization in Oligonucleotide-A Size</title><p>With purity improved from 88 to 94 percent, further investigation into expanding the study to different oligonucleotide-A chain lengths was pursued. Chain lengths ranged from 20 to 40 oligonucleotide-A. The same optimized procedure was used to treat these chains with TEAB at a constant pH of 7 and a concentration of 40 mM. <xref ref-type="table" rid="table6">Table 6</xref> and <xref ref-type="fig" rid="fig4">Figure 4</xref> summarize the outcomes of these experiments. In</p><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> Comparison of purity and yield with different Oligonucleotide lengths with constant pH 7, concentration of 40 mM, and buffer TEAB</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Length</th><th align="center" valign="middle" >Buffer</th><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >Concentration, mM</th><th align="center" valign="middle" >Purity, %</th><th align="center" valign="middle" >Yield, %</th></tr></thead><tr><td align="center" valign="middle" >Oligonucleotide-20</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >92.6 &#177; 0.2</td><td align="center" valign="middle" >76.3</td></tr><tr><td align="center" valign="middle" >Oligonucleotide-25</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.3 &#177; 0.4</td><td align="center" valign="middle" >76.1</td></tr><tr><td align="center" valign="middle" >Oligonucleotide-30</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.7 &#177; 0.1</td><td align="center" valign="middle" >75.7</td></tr><tr><td align="center" valign="middle" >Oligonucleotide-35</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >93.9 &#177; 0.3</td><td align="center" valign="middle" >74.5</td></tr><tr><td align="center" valign="middle" >Oligonucleotide-40</td><td align="center" valign="middle" >TEAB</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >94.0 &#177; 0.2</td><td align="center" valign="middle" >74.8</td></tr></tbody></table></table-wrap><p>Note: Each value is obtained based on the average of three runs.</p><p>chains longer than or equivalent to 30 oligonucleotide-A, the approach proved sufficient. Purity was found to be larger than the figure stated in the literature. The optimized process achieved a purity of 94% and a yield of 75%.</p></sec></sec><sec id="s4"><title>4. Conclusion</title><p>The proposed approach for purifying oligonucleotide-A by HPLC was rapid, accurate, and precise. This method is based on the usage of a basic working procedure for an oligonucleotide-A chain that was tuned among several parameters based on purity and yield. The process was evaluated for oligonucleotides-A ranging from 25 - 40 nucleotides in length, utilizing HPLC capabilities in the laboratory, followed by rotary evaporation and lyophilization, and products were produced with a purity of 92 - 94 percent and a yield of 75 - 79 percent. Researchers can choose the best buffer and pH for their work based on the application and sensitivity of the work.</p></sec><sec id="s5"><title>Acknowledgements</title><p>Authors would like to thank you Environmental Chemistry, Inc. in Houston, Texas for instrumentation.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Perez, C., Rani, M. and Phan, T. (2022) Optimization of High-Performance Liquid Chromatography Parameters for Purification of Oligonucleotide-A. American Journal of Analytical Chemistry, 13, 39-50. https://doi.org/10.4236/ajac.2022.132004</p></sec></body><back><ref-list><title>References</title><ref id="scirp.115537-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Biba, M., Jiang, E., Mao, B., Zewge, D., Foley, J.P. and Welch, C.J. (2013) Factors Influencing the Separation of Oligonucleotides Using Reversed-Phase/Ion-Exchange Mixed-Mode High Performance Liquid Chromatography Columns. Journal of Chromatography A, 1304, 69-77. https://doi.org/10.1016/j.chroma.2013.06.050</mixed-citation></ref><ref id="scirp.115537-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Tosi, L., Sridhara, V., Yang, Y., Guan, D., Shpilker, P., Segata, N., Larman, H.B. and Parekkadan, B. (2017) Long-Adapter Single-Strand Oligonucleotide Probes for the Massively Multiplexed Cloning of Kilobase Genome Regions. Nature Biomedical Engineering, 1, Article No. 0092. https://doi.org/10.1038/s41551-017-0092</mixed-citation></ref><ref id="scirp.115537-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Ahuja, S. and Alsante, K. (2003) Handbook of Isolation and Characterization of Impurities in Pharmaceuticals. 1st Edition, Academic Press, Cambridge.</mixed-citation></ref><ref id="scirp.115537-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">York, K.T., Smith, R.C., Yang, R., Melnyk, P.C., Wiley, M.M., Turk, C.M., Ronaghi, M., Gunderson, K.L. and Steemers, F.J. (2012) Highly Parallel Oligonucleotide Purification and Functionalization Using Reversible Chemistry. Nucleic Acids Research, 40, e4. https://doi.org/10.1093/nar/gkr910</mixed-citation></ref><ref id="scirp.115537-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Q.L., Lv, H.H., Wang, L.L., Chen, M., Li, F.F., Liang, C., Yu, Y.Y., Jiang, F., Lu, A.P. and Zhang, G. (2016) Recent Methods for Purification and Structure Determination of Oligonucleotides. International Journal of Molecular Sciences, 17, Article No. 2134. https://doi.org/10.3390/ijms17122134</mixed-citation></ref><ref id="scirp.115537-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Gong, H., Holcomb, I., Ooi, A., Wang. X., Majonis. D., Unger. M.A. and Ramakrishnan, R. (2016) Simple Method to Prepare Oligonucleotide-Conjugated Antibodies and Its Application in Multiplex Protein Detection in Single Cells. Bioconjugate Chemistry, 27, 217-225. https://doi.org/10.1021/acs.bioconjchem.5b00613</mixed-citation></ref><ref id="scirp.115537-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Pinto, A., Chen, S.X. and Zhang, D.Y. (2018) Simultaneous and Stoichiometric Purification of Hundreds of Oligonucleotides. Nature Communications, 9, Article No. 2467. https://doi.org/10.1038/s41467-018-04870-w</mixed-citation></ref><ref id="scirp.115537-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Cohen, A.S., Najarian, D.R., Paulus, A., Guttman, A., Smith, J.A. and Karger, B.L. (1988) Rapid Separation and Purification of Oligonucleotides by High-Performance Capillary Gel Electrophoresis. Proceedings of the National Academy of Sciences of the United States of America, 85, 9660-9663. https://doi.org/10.1073/pnas.85.24.9660</mixed-citation></ref><ref id="scirp.115537-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Guttman, A., Cohen, A.S., Heiger, D.N. and Karger, B.L. (1990) Analytical and Micropreparative Ultrahigh Resolution of Oligonucleotides by Polyacrylamide Gel High-Performance Capillary Electrophoresis. Analytical Chemistry, 62, 137-141. https://doi.org/10.1021/ac00201a010</mixed-citation></ref><ref id="scirp.115537-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Quarry, M.A., Grob, R.L. and Snyder, L.R. (1986) Prediction of Precise Isocratic Retention Data from Two or More Gradient Elution Runs. Analysis of Some Associated Errors. Analytical Chemistry, 58, 907-917. https://doi.org/10.1021/ac00295a056</mixed-citation></ref><ref id="scirp.115537-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Krupczy&amp;nacute;ska, K. and Buszewski, B. (2004) Chromatographic Methods Can Characterize Stationary Phases without Destroying Them. Analytical Chemistry, 76, 226A-234A. https://doi.org/10.1021/ac041583o</mixed-citation></ref><ref id="scirp.115537-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Jandera, P., Hájek, T. and &amp;Scaron;romová, Z. (2018) Mobile Phase Effects in Reversed-Phase and Hydrophilic Interaction Liquid Chromatography Revisited. Journal of Chromatography A, 1543, 48-57.</mixed-citation></ref><ref id="scirp.115537-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Van de Ven, H.C., Gargano, A.F., van der Wal, S. and Schoenmakers, P.J. (2015) Switching Solvent and Enhancing Analyte Concentrations in Small Effluent Fractions Using In-Column Focusing. Journal of Chromatography A, 1427, 90-95. https://doi.org/10.1016/j.chroma.2015.11.082</mixed-citation></ref><ref id="scirp.115537-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Schellinger, A.P. and Carr, P.W. (2006) Isocratic and Gradient Elution Chromatography: A Comparison in Terms of Speed, Retention Reproducibility and Quantitation. Journal of Chromatography A, 1109, 253-266. https://doi.org/10.1016/j.chroma.2006.01.047</mixed-citation></ref><ref id="scirp.115537-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Vy&amp;ncaron;uchalová, K. and Jandera, P. (2011) Selectivity Tests of Stationary Phases for Reversed-Phase HPLC. Analytical Letters, 44, 1640-1662.https://doi.org/10.1080/00032719.2010.520393</mixed-citation></ref><ref id="scirp.115537-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Wiczling, P., Markuszewski, M.J., Kaliszan, M. and Kaliszan, R. (2005) pH/Organic Solvent Double-Gradient Reversed-Phase HPLC. Analytical Chemistry, 77, 449-458. https://doi.org/10.1021/ac049092r</mixed-citation></ref><ref id="scirp.115537-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Ogawa, T. (2013) Protein Engineering: Technology and Application. 1st Edition, In-Tech, Rijeka. https://doi.org/10.5772/3363</mixed-citation></ref><ref id="scirp.115537-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Gargano, A.F., Duffin, M., Navarro, P. and Schoenmakers, P.J. (2016) Reducing Dilution and Analysis Time in Online Comprehensive Two-Dimensional Liquid Chromatography by Active Modulation. Analytical Chemistry, 88, 1785-1793. https://doi.org/10.1021/acs.analchem.5b04051</mixed-citation></ref></ref-list></back></article>