<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OALibJ</journal-id><journal-title-group><journal-title>Open Access Library Journal</journal-title></journal-title-group><issn pub-type="epub">2333-9705</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/oalib.1108334</article-id><article-id pub-id-type="publisher-id">OALibJ-114842</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Business&amp;Economics</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Engineering</subject><subject> Medicine&amp;Healthcare</subject><subject> Physics&amp;Mathematics</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  A Lesson Learned from a Rare Case of Missing Guide Wire
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ng</surname><given-names>Kwang How</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Anwar</surname><given-names>Irawan Ruhani</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Cardiology, Hospital Tengku Ampuan Afzan, Kuantan, Pahang, Malaysia</addr-line></aff><pub-date pub-type="epub"><day>04</day><month>01</month><year>2022</year></pub-date><volume>09</volume><issue>01</issue><fpage>1</fpage><lpage>5</lpage><history><date date-type="received"><day>28,</day>	<month>December</month>	<year>2021</year></date><date date-type="rev-recd"><day>22,</day>	<month>January</month>	<year>2022</year>	</date><date date-type="accepted"><day>25,</day>	<month>January</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Central venous catheterization via the Seldinger technique is a minimally invasive procedure which is increasingly and widely performed. It is associated with immediate and delayed complications which might cause significant morbidity and mortality. The retained guidewire is a rare, potentially serious but completely avoidable complication. We reported a 74-year-old gentleman who presented with upper gastrointestinal bleeding and was successfully resuscitated. Central venous catheterization was done but complicated with an inadvertently retained guidewire. Endovascular retrieval of the retained guidewire was successfully performed under fluoroscopic guidance and patient was subsequently discharged well. We also described its predisposing factors, preventive strategies and its successful management. This case highlights the importance of correct technique, preventive strategies and timely rectification of medical errors.
 
</p></abstract><kwd-group><kwd>Central Venous Catheterization</kwd><kwd> Retained Guide Wire</kwd><kwd> Endovascular Retrieval</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>As the technology of minimally invasive procedures advanced, procedures using intravascular objects have been increasing rapidly. Central venous catheterization (CVC) via the Seldinger technique is one of such procedures, commonly performed in critically ill patients in various departments. It is usually indicated for delivery of certain medications, prolonged intravenous therapies, parenteral nutrition, hemodialysis and difficult peripheral venous access. The common cannulation sites are femoral, jugular, subclavian and brachial veins. The increasing usage is associated with an increased risk of procedure-related complications. Correct operative skills, expert supervision, and attention to all details are needed to prevent complications. Common complications associated with CVC placement are infection, arterial puncture, hematoma, pneumothorax or vessel injury [<xref ref-type="bibr" rid="scirp.114842-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.114842-ref2">2</xref>]. Inadvertently retained guidewire is a rare complication, and can be recognized immediately during the procedure or with delay [<xref ref-type="bibr" rid="scirp.114842-ref1">1</xref>]. We presented a rare case of inadvertently retained guidewire following central venous catheterization, and described its predisposing factors, preventive strategies, endovascular retrieval and its successful outcome.</p></sec><sec id="s2"><title>2. Case Presentation</title><p>A 74-year-old gentleman with underlying diabetes, hypertension and peptic ulcer disease presented with anemic symptoms, hematemesis and melena. He was intubated for impending respiratory collapse upon arrival at the emergency department. His haemoglobin was 4.4 g/dL. Immediate oesophagogastroduodenoscopy showed a Forest 1b ulcer at the gastro-oesophageal junction. Injection of adrenaline 1:10,000 was performed. He was diagnosed to have severe anemia secondary to upper gastrointestinal bleeding. Resuscitation with intravenous fluid, blood transfusion, inotropic support and pantoprazole infusion were done. The central venous catheterization was performed under aseptic precautions at the right internal jugular vein via Seldinger technique. No difficulties during the procedure or immediate complications. Post-procedural chest X-ray showed a retained guide wire in the chest. Plain abdominal radiography confirmed the position of the guidewire’s tip, which had reached the right iliac vein (<xref ref-type="fig" rid="fig1">Figure 1</xref>). He was referred to cardiology team for endovascular guidewire retrieval after multi-disciplinary team discussion. As guidewire is a radio-opaque object, retrieval was done under fluoroscopic guidance with electrocardiogram and hemodynamic monitoring. Multiple loop snare was passed through a guiding catheter via left femoral venous approach. It captured the wire’s distal end and retracted gradually. However the wire was dislodged when it reached the left iliac vein. Snaring was re-attempted and finally the whole wire was removed successfully (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The patient was adequately heparinized throughout the procedure. Subsequently he had recovered from his illness and was discharged well.</p></sec><sec id="s3"><title>3. Diagnosis</title><p>The retained guidewire following central venous catheterization is usually diagnosed by clinical suspicion or established incidentally after the routine post-procedural radiography [<xref ref-type="bibr" rid="scirp.114842-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.114842-ref3">3</xref>]. Post-procedural radiography can also confirm the location of the retained guidewire and detect other CVC placement related complications, for example, pneumothorax or hemothorax if CVC is inserted at subclavian vein or internal jugular vein.</p></sec><sec id="s4"><title>4. Discussion</title><p>Retained guide wire is a rare but completely preventable complication. Although it is rare, minimally invasive procedures require higher awareness of retained foreign object due to its nature of reduced operative field’s visibility. It also raises the concerns of patient safety, operator responsibility and potential medicolegal consequences. Migration of a broken guide wire fragment in the circulation might cause arrhythmias, vascular damage, thrombosis and embolism. Embolism from the fragments of catheters or guide wires can be fatal up to 20% [<xref ref-type="bibr" rid="scirp.114842-ref4">4</xref>]. However, a complete guide wire loss into the circulation might be asymptomatic and may remain unnoticed for a significant period of time [<xref ref-type="bibr" rid="scirp.114842-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.114842-ref6">6</xref>]. The signs are the wire is missing, resistance to injection or poor venous backflow from the distal lumen, or wire is detected on radiograph [<xref ref-type="bibr" rid="scirp.114842-ref1">1</xref>]. Possible causes are operator inexperience or fatigue, inadequate supervision, inattention and poor lighting. Every single step of central venous cannulation is important as it might cause complications. All operators should be fully aware of the risks and complications and continuous attention during the procedure is vital. Establishing a standard of practice policy is necessary to prevent the potential unnecessary morbidity, mortality and additional invasive and costly retrieval procedures. It included checking for wire defects before insertion, ensuring the wire protrudes from the proximal end of the catheter and gripping it firmly before advancing the catheter, rechecking for damage and repositioning the introducer when encountering resistance, counting needles and wires, checking for complete wire removal after the procedure, and continuous medical training for technique improvement [<xref ref-type="bibr" rid="scirp.114842-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.114842-ref7">7</xref>]. An immediate post-procedural radiograph is important to confirm the position of the catheter and to detect complications. It is important to remove the retained guidewire with appropriate tools and expertise, as quickly and completely as possible [<xref ref-type="bibr" rid="scirp.114842-ref8">8</xref>]. Percutaneous retrieval of intravascular foreign bodies was first introduced in 1964 by Thomas et al., and has become a preferred approach for intravascular objects removal since then [<xref ref-type="bibr" rid="scirp.114842-ref9">9</xref>]. Endovascular retrieval’s options are loop snare, balloon catheter, basket retriever, and grasping forceps. The standard method is the loop snare via femoral vein under radiographic guidance, which has higher success rate and lower complications [<xref ref-type="bibr" rid="scirp.114842-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.114842-ref11">11</xref>]. Retrieval of retained guide wire has a success rate of 90% [<xref ref-type="bibr" rid="scirp.114842-ref12">12</xref>]. The use of endovascular forceps or Dormier baskets increases the risk of endovascular trauma [<xref ref-type="bibr" rid="scirp.114842-ref13">13</xref>]. Patient should be adequately heparinized during the intervention [<xref ref-type="bibr" rid="scirp.114842-ref13">13</xref>]. If heparinization is contraindicated, careful surgical exploration and extraction should be considered [<xref ref-type="bibr" rid="scirp.114842-ref7">7</xref>].</p></sec><sec id="s5"><title>5. Conclusion</title><p>Our intention of reporting this inadvertently retained guide wire and its management is to emphasize the importance of correct technique, preventive strategies, risks awareness, timely rectification of medical errors, and effective multi-disciplinary team communication.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>How, N.K. and Ruhani, A.I. (2022) A Lesson Learned from a Rare Case of Missing Guide Wire. Open Access Library Journal, 9: e8334. https://doi.org/10.4236/oalib.1108334</p></sec></body><back><ref-list><title>References</title><ref id="scirp.114842-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Srivastav, R., Yadav, V., Sharma, D. and Yadav, V. (2013) Loss of Guide Wire: A Lesson Learnt Review of Literature. Journal of Surgical Technique and Case Report, 5, 78-81. https://doi.org/10.4103/2006-8808.128732</mixed-citation></ref><ref id="scirp.114842-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Wolf, F., Schernthaner, R.E., Dirisamer, A., Schoder, M., Funovics, M., Kettenbach, J., et al. (2008) Endovascular Management of Lost or Mis-Placed Intravascular Objects: Experiences of 12 Years. CardioVascular and Interventional Radiology, 31, 563-568. https://doi.org/10.1007/s00270-007-9201-8</mixed-citation></ref><ref id="scirp.114842-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Guo, H., Peng, F. and Ueda, T. (2006) Loss of the Guide Wire: A Case Report. Circulation Journal, 70, 1520-1522. https://doi.org/10.1253/circj.70.1520</mixed-citation></ref><ref id="scirp.114842-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Heberer, M., Moser, J., Durig, M. and Harder, F. (1984) Prospective Study of Complications of Central Venous Catheters. Transfusion Medicine and Hemotherapy, 11, 254-261. https://doi.org/10.1159/000221671</mixed-citation></ref><ref id="scirp.114842-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Abuhasna, S., Abdallah, D. and ur Rahman, M. (2011) The Forgotten Guide Wire: A Rare Complication of Hemodialysis Catheter Insertion. Journal of Clinical Imaging Science, 1, Article No. 40. https://doi.org/10.4103/2156-7514.83397</mixed-citation></ref><ref id="scirp.114842-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Wadehra, A., Ganjoo, P. and Tandon, M.S. (2010) Guide Wire Loss during Central Venous Cannulation. Indian Journal of Anaesthesia, 54, 587-588.  
https://doi.org/10.4103/0019-5049.72665</mixed-citation></ref><ref id="scirp.114842-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Schummer, W., Schummer, C., Gaser, E. and Bartunek, R. (2002) Loss of the Guide Wire: Mishap or Blunder? British Journal of Anaesthesia, 88, 144-146.  
https://doi.org/10.1093/bja/88.1.144</mixed-citation></ref><ref id="scirp.114842-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Michaelis, G. and Biscoping, J. (2000) Clinical Significance and Effects of Foreign Body Embolism during the Use of Central Venous Catheters. Anasthesiol Intensivmed Notfallmed Schmerzther, 35, 137-140. https://doi.org/10.1055/s-2000-8747</mixed-citation></ref><ref id="scirp.114842-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Thomas, J., Sinclair-Smith, B., Bloomfield, D. and Davachi, A. (1964) Non-Suurgi- calretrieval of a Broken Segment of Steel Spring Guide from the Right Atrium and Inferior Vena Cava. Circulation, 30, 106-108.  
https://doi.org/10.1161/01.CIR.30.1.106</mixed-citation></ref><ref id="scirp.114842-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Cheng, C.C., Tsai, T.N., Yang, C.C. and Han, C.L. (2009) Percutaneous Retrieval of Dislodged Totally Implantable Central Venous Access System in 92 Cases: Experience in a Single Hospital. European Journal of Radiology, 69, 346-350.  
https://doi.org/10.1016/j.ejrad.2007.09.034</mixed-citation></ref><ref id="scirp.114842-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Egglin, T.K., Dickey, K.W., Rosenblatt, M. and Pollak, J.S. (1995) Retrieval of Intravascular Foreign Bodies: Experience in 32 Cases. American Journal of Roentgenology, 164, 1259-1264. https://doi.org/10.2214/ajr.164.5.7717243</mixed-citation></ref><ref id="scirp.114842-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Dondelinger, R.F., Lepoutre, B. and Kurdziel, J.C. (1991) Percutaneous Vascular Foreign Body Retrieval: Experience of an 11-Year Period. European Journal of Radiology, 12, 4-10. https://doi.org/10.1016/0720-048X(91)90124-E</mixed-citation></ref><ref id="scirp.114842-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Kessel, D. and Robertson, I. (2000) Interventional Radiology—A Survival Guide. Churchill-Livingstone, London, 225-229.</mixed-citation></ref></ref-list></back></article>