<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JEMAA</journal-id><journal-title-group><journal-title>Journal of Electromagnetic Analysis and Applications</journal-title></journal-title-group><issn pub-type="epub">1942-0730</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jemaa.2009.14036</article-id><article-id pub-id-type="publisher-id">JEMAA-1117</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Active Power Filter Based on Adaptive Detecting Approach of Harmonic Currents
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>u</surname><given-names>ZHANG</given-names></name><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yupeng</surname><given-names>TANG</given-names></name><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><author-notes><corresp id="cor1">* E-mail:<email>08122036@bjtu.edu.cn(UZ)</email>;<email>yptang@bjtu.edu.cn(YT)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>30</day><month>12</month><year>2009</year></pub-date><volume>01</volume><issue>04</issue><fpage>240</fpage><lpage>244</lpage><history><date date-type="received"><day>September</day>	<month>17th,</month>	<year>2009</year></date><date date-type="rev-recd"><day>October</day>	<month>29th,</month>	<year>2009</year>	</date><date date-type="accepted"><day>November</day>	<month>7th,</month>	<year>2009.</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The ip-iq detection method based on instantaneous inactive power theory has been applied widely in active power filter because of its good real-time. But it needs large computation, and three-phase currents are processed as integrity, thus calculation accuracy can't be ensured. Based on adaptive interference canceling theory, this paper presents a new ad- aptive detection method for harmonic current, it is a continuously regulated closed-loop system, and its operating characteristics are almost independent of the parameter variations of the elements, thus it performs better than that based on traditional theory. At last this paper provides the simulation of active power filter including the detecting cir-cuit which proved the design is feasible and correct.
 
</p></abstract><kwd-group><kwd>Adaptive Interference Canceling</kwd><kwd> Adaptive Harmonic Detecting</kwd><kwd> Active Power Filter</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Because of the use of more nonlinear loads, especially more power electronic equipments, a large number of harmonic and reactive currents have been introduced into power grid, resulting in some problems such as voltage flicker, frequency variation, imbalance of three-phase&#160; problem, etc [<xref ref-type="bibr" rid="scirp.1117-ref1">1</xref>]. In order to suppress the harmonics, passive filters have been used in the past years [<xref ref-type="bibr" rid="scirp.1117-ref2">2</xref>], while recently Active Power Filter (APF) has been developed rapidly. Widely used in APF, the harmonic detection method is based on three-phase instantaneous inactive power theory. Thus a lot of analog multipliers and calculation are needed, resulting in difficult adjust and poor performance [3-4]. Furthermore, this method is only suitable for a three-phase equilibrium sinusoidal system.</p><p>This paper presents a new adaptive closed-loop detection method based on adaptive interference canceling theory, and the simulation results show that the filter based on this new method performs better than that based on the three-phase instantaneous inactive power theory, and with higher accuracy [<xref ref-type="bibr" rid="scirp.1117-ref5">5</xref>].</p></sec><sec id="s2"><title>2. The Basic Principle of an Active Filter</title><p>An active power filter is a new power electronic device of dynamic harmonic suppression. <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the basic principle. There are four parts in a shunt APF: the main circuit, command current operational circuit, current tracking control circuit, and the drive circuit. The command current operation circuit detects the harmonic component i<sub>Lh</sub>, in the load current i<sub>L</sub>, and takes the opposite value as command signal<img src="7-9800175\3320d0d8-8664-4bb4-a68b-3b6c5d33de2f.jpg" />. The principle can be expressed by the following formula</p><p><img src="7-9800175\cbfc344e-b0df-479a-b8cb-6eba06d17420.jpg" /></p><p><img src="7-9800175\03bae40b-5104-4821-948f-ad698a9b7206.jpg" /></p><p><img src="7-9800175\0c11b386-95a9-4032-8f1a-f631a03428ef.jpg" /></p><p><img src="7-9800175\ba543445-4b86-4881-acbd-b108ee8a018b.jpg" /></p><p>where i<sub>S</sub>, i<sub>L</sub> are currents of the supply and a nonlinear load, respectively, and i<sub>c</sub> is the compensation current. i<sub>L</sub><sub>f</sub>, i<sub>Lh</sub> are the fundamental active and harmonic reactive components of the load current, respectively.</p></sec><sec id="s3"><title>3. Adaptive Detecting Algorithm</title><sec id="s3_1"><title>3.1 The Basic Principle of Adaptive Interference Canceling Theory</title><p>The adaptive interference canceling technique has been widely used in recent years [<xref ref-type="bibr" rid="scirp.1117-ref6">6</xref>]. By continuously selfstudying and self-adjusting, the detecting system can always operate at its best. The basic noise-canceling theory can be illustrated in <xref ref-type="fig" rid="fig2">Figure 2</xref>. In the detecting system, there are two unrelated input signals: original input s+n<sub>0</sub> and reference input n<sub>1</sub>. And s is unrelated with n<sub>0</sub> and n<sub>1</sub>, while n<sub>0</sub> and n<sub>1</sub> are related. The reference input signal n<sub>1</sub> is filtered by an adaptive filter to produce an output signal<img src="7-9800175\383cacba-3299-45e4-a6f7-409b7c0c0ab6.jpg" />, which is an approximate replica of n<sub>0</sub>. This output <img src="7-9800175\dabf3105-fc8d-4f6b-af00-2037219283d3.jpg" /> is subtracted from the original input signal s+n<sub>0</sub> to produce<img src="7-9800175\cdd132cb-1840-40a7-8369-bada8299034a.jpg" />, the system output signal.</p><p>In the system shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>, the reference input is processed by an adaptive filter which automatically adjusts its own response through a least-squares algorithm. Thus the filter can detect the noise n<sub>0</sub> continuously and adjust the system to minimize the error signal e. It can be proved that <img src="7-9800175\3a6e83ac-0abb-4183-96a4-2de86bb6cf85.jpg" /> is the best least-squares estimate of n<sub>0</sub>, when the filter is adjusted to make the error signal power <img src="7-9800175\67bff24c-27c1-4be9-8489-060ff1977177.jpg" /> minimum.</p></sec><sec id="s3_2"><title>3.2 Adaptive Harmonic Detection</title><p>Based on the principle of adaptive noise canceling theory, adaptive harmonic current detecting circuit is shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The system is composed of an analog adaptive filter, a BPF (Band Pass Filter) and a 90<sup>0</sup> phase-shifter [<xref ref-type="bibr" rid="scirp.1117-ref7">7</xref>]. The primary input is the load current:<img src="7-9800175\fc6f1f9b-cccc-4ef9-9d36-46df9f045e1c.jpg" />, where i<sub>1</sub>(t) is the fundamental current, i<sub>h</sub>(t) is the sum of all harmonic components, and i<sub>p</sub>(t), i<sub>q</sub>(t) are the active component and the reactive component of i<sub>1</sub>(t), respectively in <xref ref-type="fig" rid="fig3">Figure 3</xref>. u(t) and u<sub>1</sub>(t) are the AC source voltage and its fundamental component, respectively. R<sub>1</sub>(t) and R<sub>2</sub>(t) are two reference inputs orthogonal to each other, and i<sub>0</sub>(t) is the system output.</p><p>As shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, because both feedback branches are similar, we take the lower feedback branch as an example. Only the fundamental reactive component which has the same frequency with <img src="7-9800175\bc723dfc-8f53-4cd8-9469-8ae0c166712a.jpg" /> can produce the DC signal after the output current i<sub>0</sub>(t) is multiplied by<img src="7-9800175\70aa6241-52ec-401e-ac2f-5cf4a657b0b3.jpg" />, while other components produce AC signals after the same procession. The DC component can be integrated to get the average value of fundamental reactive current I<sub>Fp</sub>, while the AC component will be zero after the same calculation. Thus, we can get the instantaneous fundamental reactive current i<sub>fq</sub>(t) by</p><p>multiply I<sub>Fp</sub> with R<sub>1</sub>(t). Similarly, using R<sub>2</sub>(t), we can get the instantaneous fundamental active current i<sub>fp</sub>(t). At last, by adding the reverse of i<sub>fp</sub>(t)+i<sub>fq</sub>(t) to i(t), the output current i<sub>0</sub>(t)=i<sub>h</sub>(t) is produced. If only the current i<sub>0</sub>(t)=i<sub>h</sub>(t)+i<sub>fq</sub>(t) is needed, what we should do is remove the R<sub>1</sub>(t) branch.</p><p>We can also explain the principle in the phase space. Assume the reference inputs which processed by the BPF are:</p><p><img src="7-9800175\1d69ff2a-fb8c-4327-ba72-5cf901b01524.jpg" />,</p><p><img src="7-9800175\ff01cdf4-ac51-41f0-8a30-f430a6626de4.jpg" />.</p><p>Then the output of the multiplier M1 can be expressed as:</p><p><img src="7-9800175\f9eddc26-f17f-47c3-a7de-5bcc90b1455c.jpg" /></p><disp-formula id="scirp.1117-formula139805"><label>(1)</label><graphic position="anchor" xlink:href="7-9800175\2f8df667-8ccf-49b7-849f-22e0ec84d52a.jpg"  xlink:type="simple"/></disp-formula><p>Taking the Laplace transform of (1), we have</p><disp-formula id="scirp.1117-formula139806"><label>(2)</label><graphic position="anchor" xlink:href="7-9800175\679d7510-c2b9-4e39-aa75-19d00171d4e5.jpg"  xlink:type="simple"/></disp-formula><p>where, I<sub>0</sub>(s) is the Laplace transform of i<sub>0</sub>(t). After processed by the integrator, whose transform is <img src="7-9800175\fe9dfe82-744b-4e09-8e83-30bf027b7d8f.jpg" /> (here G is the integration gain), the transform of the feedback signal can be expressed as:</p><disp-formula id="scirp.1117-formula139807"><label>(3)</label><graphic position="anchor" xlink:href="7-9800175\818ae594-c6c7-47f8-9b4d-bf47c7385736.jpg"  xlink:type="simple"/></disp-formula><p>The output of the multiplier <img src="7-9800175\68b68ada-ba87-4a70-9290-867ad3da07e5.jpg" /> is simply the feedback signal of the lower branch, which mean<img src="7-9800175\751ec1ac-dbce-45b5-b0aa-0405bd92a677.jpg" />. Its transform is:</p><p><img src="7-9800175\d6179de3-bb8e-4f6d-bd85-9d93f02de9cc.jpg" /></p><p><img src="7-9800175\8dbf5870-9cd7-47fa-8a50-a11f77322c04.jpg" /></p><p><img src="7-9800175\6aedf914-43c7-4279-a5f9-0cbb3250687d.jpg" /></p><disp-formula id="scirp.1117-formula139808"><label>(4)</label><graphic position="anchor" xlink:href="7-9800175\3f4cd8b9-ec6b-47e9-b523-adf01d4fecdd.jpg"  xlink:type="simple"/></disp-formula><p>Similarly, the transform F<sub>2</sub>(s) of the feedback signal f<sub>2</sub>(t) for the upper feedback branch can be expressed as:</p><p><img src="7-9800175\94a0e9d1-5a9d-4d4d-a9bf-1f05b9cd26f6.jpg" /></p><disp-formula id="scirp.1117-formula139809"><label>(5)</label><graphic position="anchor" xlink:href="7-9800175\65bfb81f-4573-4c6a-b6ee-fa3e0334a689.jpg"  xlink:type="simple"/></disp-formula><p>The total feedback signal is:</p><p><img src="7-9800175\03d890ab-4122-4388-9458-e87b366534a0.jpg" /></p><p>Its transform is:</p><disp-formula id="scirp.1117-formula139810"><label>(6)</label><graphic position="anchor" xlink:href="7-9800175\79660809-a9e7-4f80-9f40-4ba18008c015.jpg"  xlink:type="simple"/></disp-formula><p>Thus the feedback coefficient of the whole system is:</p><disp-formula id="scirp.1117-formula139811"><label>(7)</label><graphic position="anchor" xlink:href="7-9800175\20c9872b-daeb-4ede-a180-1d4674306b13.jpg"  xlink:type="simple"/></disp-formula><p>Then the transfer function H(s) of the system is:</p><disp-formula id="scirp.1117-formula139812"><label>(8)</label><graphic position="anchor" xlink:href="7-9800175\6023b9fd-6550-4aa1-83d0-1acef22587dd.jpg"  xlink:type="simple"/></disp-formula><p>From (8), when<img src="7-9800175\f7d29e6f-aa52-41fe-b087-fc375c9ad3b2.jpg" />, <img src="7-9800175\f64623ee-2fb2-47bf-87f0-d37110df508c.jpg" />, which means a zero point exists in the system corresponding to the fundamental frequency <img src="7-9800175\82ff7fb2-44c2-4ae8-81fe-f523b2f39770.jpg" /> Consequently the fundametal signal will be greatly attenuated. It is obvious that the system shown in <xref ref-type="fig" rid="fig3">Figure 3</xref> is equivalent to an ideal second-order notch filter. In addition, the center frequency of the system depends solely on the frequency signal <img src="7-9800175\3be81931-f340-45cb-a7b7-c93d981022b3.jpg" /> of the reference input. Therefore, the system is independent of parameter of the circuit components, which means that the system is almost stable while the temperature varies or the circuit components ages.</p></sec><sec id="s3_3"><title>3.3 DC Side Voltage Control</title><p>Ideally, what an active filter compensates is the non-active power; that is to say, it neither absorbs active power from the power supply nor outputs to it, so the DC side voltage of an active filter is constant. However, due to the loss of the active filter, energy in the capacitor on</p><p>the DC side will reduce, making the voltage on the capacitor drop.</p><p>In order to maintain the voltage on the capacitor, the feedback method has usually been adopted, whose purpose is to obtain some active power from the source to compensate the corresponding loss.</p><p>As shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>, U<sub>cr , </sub>U<sub>cf</sub> are the reference and feedback values of U<sub>c</sub>, respectively. The difference between U<sub>cr</sub> and U<sub>cf</sub> is regulated by PI to get the signal<img src="7-9800175\ff77bed9-10d0-4b01-94d8-7d065de09c4c.jpg" />.</p><p>Since <img src="7-9800175\826d3af2-b44a-48c9-b42e-fb8de20a51a5.jpg" /> contains the fundamental active component , i<sub>c</sub>, which comes from<img src="7-9800175\e441b288-982d-4d02-b9ca-ffa130a14720.jpg" />, also contains such a component. Therefore, when i<sub>c</sub> is introduced into the power system, APF can exchange the active energy between AC and DC sides, which keeps U<sub>c</sub> constant.</p></sec></sec><sec id="s4"><title>4. Simulation Results</title><p>In this section, computer simulation is carried out to verify the design of the adaptive shunt active filter. A three-phase distribution system is built using Matlab as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. Simulation parameters are as following: AC source is 220V/50Hz, supply side inductance Ls is 0.2μH. The nonlinear load parameters for three-phase full-controlled bridge rectifier are R= 20Ω, L=0.1H. In the main circuit of the active filter, IGBT is used as the switch, and the inductance on the AC side La is 5mH, while the capacitance is 2200μF/1000V on the DC side.</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows the AC source voltage, the power supply currents before and after filterd, respectively, and the harmonic and reactive reference currents. From <xref ref-type="fig" rid="fig6">Figure 6</xref>(b), we can see that before filtered, the current lags the source voltage and contains a lot of harmonic and reactive components. After filtered by the APF, shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>(d), the supply current is nearly sinusoidal and in phase with AC source voltage, which means APF corrects the power factor of the supply side nearly to unity. There is a variation in the nonlinear current at t=0.1s, From <xref ref-type="fig" rid="fig6">Figure 6</xref> it can be seen the proposed adaptive shunt active filter only needs approximately half a cycle to adapt itself to the change.</p><p>Since the APF adopts traditional hysteresis current control method, the tracking ability of APF is limited, resulting in some ripples in the current when it changes suddenly, as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>(d).</p><p>The DC capacitor voltage is shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>, it only</p><p>takes about 0.05s to reach at the desired value of 1000V and stabilize rapidly.</p><p>Compared <xref ref-type="fig" rid="fig8">Figure 8</xref> with <xref ref-type="fig" rid="fig9">Figure 9</xref>, it shows the harmonic and reactive currents are greatly restrained.</p><p>It shows from <xref ref-type="fig" rid="fig9">Figure 9</xref> and <xref ref-type="fig" rid="fig1">Figure 1</xref>0, under the same conditions, after APF input, the THD of the supply current based on adaptive interference canceling theory drops to 10.50%, but that based on instantaneous inactive power theory is only 12.30%, moreover, the method based on traditional theory uses 6 analog summer, 4 multipliers and lots of gains, thus the calculation accuracy is more difficult to be assured in practice. The method based on adaptive interference canceling theory uses only 6 multipliers and 3 integrators, which ensures better performance in actual operation than that based on instantaneous inactive power theory.</p><p>Overall, it shows that the proposed adaptive shunt active filter can compensate nonlinear load current, adapt itself to compensate the variations in nonlinear load currents and correct the power factor of the supply side nearly to unity.</p></sec><sec id="s5"><title>5. Conclusions</title><p>In this paper, a novel adaptive detection method for harmonic and reactive current is proposed. This method is analyzed systematically and verified by Matlab simulation. It is a continuously regulated closed-loop system, and the operating characteristics are nearly independent of the parameter variations of the elements, and bandwidth behaving as one of a second-order notch filter can be regulated easily by controlling the amplitude of the reference input and the gain of the integrator. Furthermore, this paper also introduces DC side voltage control method, which is simple and effective. Finally, simulation result is given to conform the feasibility of the design.</p></sec><sec id="s6"><title>REFERENCES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.1117-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">R. Bojoi, G. Griva, F. Profumo, M. Cesano, and L. Natale, “Shunt active filter implementation for induction heating applications,” Applied Power Electronics Conference and Exposion, Vol. 3, pp. 1674–1679, March 2005.</mixed-citation></ref><ref id="scirp.1117-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple"> 
D. Liu, B. D. Zhang, and X. L. Zhang, “Design of adaptive increment controlled hybrid-type active power filter,” Power and Energy Engineering Conference, Asia-Pacific, Vol. 27–31, No. 3, pp. 1–4. 2009.</mixed-citation></ref><ref id="scirp.1117-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple"> 
H. Akagi, E. H. Watanabe, and M. Aredes, “Instantaneous power theory and applications to power conditioning,” Wiley-Interscience a John Wiley &amp; Sons, Inc., Publication, 2007.</mixed-citation></ref><ref id="scirp.1117-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple"> 
H. Akagi, “Generalized theory of instantaneous reactive power and its application,” Elec.Eng. in Japanese, April 1983.</mixed-citation></ref><ref id="scirp.1117-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple"> 
L. H. Tey and Y. C. Chu, “Improvement of power quality using adaptive shunt active filter,” IEEE Transactions on Power Delivery, Vol. 20, pp. 1558–1568, April 2005.</mixed-citation></ref><ref id="scirp.1117-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple"> 
B. Widrow and S. P. Sterns, “Adaptive signal processing,” Englewood Cliffs, Prentice-Hall, NJ, inc., 1985.</mixed-citation></ref><ref id="scirp.1117-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple"> 
J. H. Husy and M. S. E. Abadi, “Unified approach to adaptive filters and their performance,” IET Signal Process, Vol. 2, No. 2, pp. 97–109, 2008.</mixed-citation></ref><ref id="scirp.1117-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple"> 
A. Nakajima, “Development of active filter with series resonant circuit,” IEEE-PESC, Annual Meeting, pp. 1168–1173, 1988.</mixed-citation></ref><ref id="scirp.1117-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple"> 
Q. Wang, N. Wu, and Z. A. Wang, “A neuron adaptive detecting approach of harmonic current for apf and its realization of analog circuit,” IEEE Transactions on instrumentation and measurement,” Vol. 50, pp. 77–84, February 2001.</mixed-citation></ref><ref id="scirp.1117-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple"> 
H. P. To, F. Rahman, and C. Grantham, “An adaptive algorithm for controlling reactive power compensation in active power filters,” Industry Applications Conference, 39th IAS Annual Meeting, Vol. 1, pp. 3– 7, October 2004.</mixed-citation></ref><ref id="scirp.1117-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple"> 
L. P. Ling and A. Azli, “SVM based hysteresis current controller for a three phase active power filter,” Power and Energy Conference, pp. 132–136, November 2004.</mixed-citation></ref></ref-list></back></article>