<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">CN</journal-id><journal-title-group><journal-title>Communications and Network</journal-title></journal-title-group><issn pub-type="epub">1949-2421</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/cn.2021.132005</article-id><article-id pub-id-type="publisher-id">CN-109213</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Computer Science&amp;Communications</subject></subj-group></article-categories><title-group><article-title>
 
 
  Cost Optimization Modeling of Renewable Energy Sources in Smart-Grid Using SCADA
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nafisa</surname><given-names>Islam</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Warsame</surname><given-names>H. Ali</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Emmanuel</surname><given-names>S Kolawole</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>John</surname><given-names>Fuller</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Pamela</surname><given-names>Obiomon</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>John</surname><given-names>O. Attia</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Samir</surname><given-names>Abood</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Electrical and Computer Engineering, Prairie View A &amp;amp; M University, Prairie View, USA</addr-line></aff><pub-date pub-type="epub"><day>21</day><month>05</month><year>2021</year></pub-date><volume>13</volume><issue>02</issue><fpage>51</fpage><lpage>67</lpage><history><date date-type="received"><day>17,</day>	<month>October</month>	<year>2020</year></date><date date-type="rev-recd"><day>18,</day>	<month>May</month>	<year>2021</year>	</date><date date-type="accepted"><day>21,</day>	<month>May</month>	<year>2021</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In recent times, renewable energy production from renewable energy sources is an alternative way to fulfill the increased energy demands. However, the increasing energy demand rate places more pressure, leading to the termination of conventional energy resources. However, the cost of power generation from coal-fired plants is higher than the power generation’s price from renewable energy sources. This experiment is focused on cost optimization during power generation through pumped storage power plant and wind power plant. The entire modeling of cost optimization has been conducted in two parts. The mathematical modeling was done using MATLAB simulation while the hydro and wind power plant’s emulation was performed using SCADA (Supervisory control and data acquisition) designer implementation. The experiment was conducted using ranges of generated power from both power sources. The optimum combination of output power and cost from both generators is determined via MATLAB simulation within the assumed generated output power range. Secondly, the hydro-generator and wind generator’s emulation were executed individually through synchronizing the grid to determine each generator’s specification using SCADA designer, which provided the optimum power generation from both generators with the specific speed, aligning with results generated through MATLAB. Finally, the operational power cost (with no losses consideration) from MATLAB was compared with the local energy provider to determine the cost-efficiency. This experiment has provided the operational cost optimization of the hydro-wind combined power system with stable wind power generation using SCADA, which will ultimately assist in operations of large-scale power systems, remotely minimizing multi-area dynamic issues while maximizing the system efficiency.
 
</p></abstract><kwd-group><kwd>Smart-Grid</kwd><kwd> Cost Optimization</kwd><kwd> Economic Dispatch</kwd><kwd> SCADA</kwd><kwd> Renewable Energy Sources</kwd><kwd> MATLAB</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The increasing energy demand rate places more pressure on the termination of conventional energy resources. Therefore, it has become a significant phenomenon to balance this extensive energy demand by enforcing the proper use of resources that already existed and implementing new resources to optimize the cost accordingly. On the other hand, the depletion of fossil fuels like coal, petroleum, natural gas, etc. is creating an adverse effect on the environment. Global warming, emissions of greenhouse gases, climate change are the negative impact that is associated with nature is being produced by fossil fuel-based energy generation.</p><p>Energy management is the energy policy algorithm, planning, execution, and actions to propagate resource conservation, climate protection, and cost savings while sufficient energy demand is being fulfilled. The optimization of using new renewable energy sources connecting with the previous existing resources may cause distinct complications. Cost optimization is the process that attempts to function cost reduction disciplines with the standard pricing, simplifies the platform, and executes the plan/application related to cost for a particular item. Economic dispatch (ED) defines the system providing the demand load over the appointed units with the lowest power production cost [<xref ref-type="bibr" rid="scirp.109213-ref1">1</xref>]. The dispatch operating department can focus on the indicated aspects to influence the economic dispatch accomplishment procedures, which provides the accomplishment to function and optimize the power system with decent quality, economy, and environmental security protection [<xref ref-type="bibr" rid="scirp.109213-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref6">6</xref>]. Moreover, ED is considered the simplest to formulate on a long-term basis instead of utilizing the power system daily efficiently. To overcome this shortcoming, the investigation of the problem should be not just focused on economic viewpoint but also should direct the question into multiple time intervals with different and interconnected power systems [<xref ref-type="bibr" rid="scirp.109213-ref7">7</xref>]. Regarding these (Multi-Area Dynamic ED) MADED problems, literature [<xref ref-type="bibr" rid="scirp.109213-ref8">8</xref>] illustrated a spectacle for reducing the cost of consumption by assuming the percolation of wind power and pumped storage power plants. The pumped storage power station has also become the economic peaking power supply because of its flexibility, reliability, and capacity. A combination of wind and pumped storage power plants are considered financial and the solution to this problem. Pumped storage utilization helps to smooth and improve the fluctuations of the combined power generation system of wind and pumped storage power plants. Literature [<xref ref-type="bibr" rid="scirp.109213-ref9">9</xref>] portrays an optimization prototype for wind power plant, which contains the highest efficacy and steady output power with the proposed optimization model of the non-dominant sequencing genetic algorithm with elite strategy. Wind generator control, limitation of power and management for pumped storage, mismatch of selling cost and penalty cost between the assigned and the supplied energy leads to the cost reduction of the system [<xref ref-type="bibr" rid="scirp.109213-ref10">10</xref>]. A strategy that helps solve scheduling issues also plays an essential role in making the system economical [<xref ref-type="bibr" rid="scirp.109213-ref11">11</xref>]. The researchers emphasized various facts to improve the load fluctuation, power integration, and cost optimization due to the multiple constraints in applying pumped storage and wind power plant. In the literature [<xref ref-type="bibr" rid="scirp.109213-ref12">12</xref>], the traditional numerical calculation of wind-hydro power stations has approached after a wind load combination to match the equivalent load. Literature [<xref ref-type="bibr" rid="scirp.109213-ref13">13</xref>] illustrated the model to progress the capacity of wind power integration. Furthermore, the reduction of wind power fluctuation is achieved by implementing the improved Bat algorithm that portrayed the pumped storage-wind combined power system [<xref ref-type="bibr" rid="scirp.109213-ref14">14</xref>]. In the beginning, the focus was on the individual power plant itself. Later on, many research types have been done to optimize jointly multiple power plants like wind-hydro, wind-hydro-thermal, wind-solar-thermal, etc. Literature [<xref ref-type="bibr" rid="scirp.109213-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref12">12</xref>] illustrated that a numerical algorithm to optimize the equivalent or the factuality of the wind power plant in the power system instead of focusing on cost optimization. Also, [<xref ref-type="bibr" rid="scirp.109213-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.109213-ref14">14</xref>] emphasized optimization by improving a numerical method, whereas it can be more focused on the operation and control.</p><p>In this literature, the hydro-wind power station’s economic dispatch is calculated with a SCADA system considered modern technology. The phenomena of this technology are used to control the power flow from the generators to loads. The advantage of using the SCADA system is to maintain the microgrid’s operating schedule by the smart grid communication technology as PLC. Also, the result obtained from the SCADA system is verified by MATLAB program code. But the benefit of using the SCADA system is to control the operating schedule remotely, while there is no such technique in MATLAB. Particularly, operation remotely by the SCADA system has been recommended more beneficial as MATLAB lacks this operation. Therefore, a concept has proposed to acquire the solution of these technical problems associated with the Smart Grid network worked as an integral part of the management scheme.</p></sec><sec id="s2"><title>2. Renewable Energy and Traditional System</title><p>Renewable energy is the recollected energy from renewable resources. It can be defined that power and energy generated from different sources like solar, wind, ocean, hydropower, biomass, geothermal resources, and hydrogen originated from renewable resources.</p><p>1) Pumped storage Power Plant</p><p>The availability of water is an essential requirement for hydropower generation. Hydropower generates both kinetic energy and potential energy. Usually, the water from lakes and the water from reservoirs at an elevated level is the hydropower generation source. The hydroelectric power plant needs the generator coupled with the turbine with the rotation to generate power, HV/EHV transmission lines to connect with the other power plants altogether. A three-phase alternating current synchronous generator is used in pumped storage plants. The armature is housed in the stator consisting of a core and fame. The center acts as a magnetic circuit and is shaped by a massive steel ring built up of thin electrical quality sheet steel laminations. The excitation control adjusts the reactive load taken by each generator. Voltage regulators serve the purpose of maintaining the voltage of the turbine clenched on the desired value at the machine bus.</p><p>2) Wind Power Plant</p><p>Typical Structure of Horizontal-Axis Wind Turbines:</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>(a) and <xref ref-type="fig" rid="fig1">Figure 1</xref>(b) displays the main modules of the HAWT rotor, which are blades and a central hub. The maintenance of designing the power train is less since the power train is situated over the HAWT tower. A passive yaw drive permits wind energy to adjust the nacelle. A rotor that contains two blades creates larger cyclical loads than a three-bladed rotor on the yaw drive.</p><p>Typical Structure of Vertical-Axis Wind Turbines:</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows the curved blades are secured with rigid upper and lower hubs and divided by the rotor column. Blades are shaped to a troposkien shape with zero bending stress to decrease internal bending stresses through the rotation, contains two or three fixed-pitch blades which are cross-sectionally equal.</p><p>3) Induction Generator</p><p>The induction generator converts mechanical energy into electrical energy like other generators. The power generated from wind energy involves the use of a Doubly-Fed Induction Generator (DFIG). A DFIGURE is used to dampen this disruption. A basic configuration of DFIGURE is shown below:</p><p>The generator consists of two converters: MSC and LSC shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. Also, the DC chopper and crowbar play an essential role when faults disrupt the system. When there is a constant wind energy input, the DFIGURE supplies the machine-side converter and generator with reactive power. During a period of disruption in unsteady wind energy, a voltage dip is noted and supplied reactive power can be stabilized through the line-side converter. When the system disrupts with the turbine’s faulty power flow, it results in a high generation of energy between the machine-side converter and the line-side. This excess energy flowing from the rotor circuit into the MSC can be harnessed via a DC Chopper. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the connection of the DC Chopper and crowbar to the DFIGURE that will be connected to the wind turbine.</p></sec><sec id="s3"><title>3. Transmission Line</title><p>The transmission line is a medium to transmit to radiofrequency, voltages. A transmission line is a circuit along with distributed parameters, such as series resistance, series inductance, shunt capacitance, and shunt conductance are distributed along the whole length of the line, as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>.</p><p>The d.c resistance of several types of conductors at a specified temperature T is found by:</p><p>R d c . T = ρ T l A (3.1)</p><p>where ρ T conductor resistivity at temperature T (Ω∙m)</p><p>L—conductor length (m);</p><p>A—conductor cross-sectional area (m<sup>2</sup>).</p><p>It is defined as the flux linkages per unit current,</p><p>L = ψ I (3.2)</p><p>where ψ is flux linkage (Weber-turns)</p><p>I is current (amperes);</p><p>L is a constant of proportionality, inductance (henrys).</p><p>Potential difference is the number of charges through two points of a conductor.</p><p>C = q V   F / m (3.3)</p><p>Usually, the two conductors’ capacitance is constant when placed in parallel, but this constant is subjected according to the conductors’ size and placement.</p><p>The ratio of output power and input power of the transmission line is the transmission efficiency.</p><p>Transmission efficiency</p><p>η T L = ( V r I r ) ( cos θ ) ( V S I S ) ( cos ϕ S ) &#215; 100 (3.4)</p></sec><sec id="s4"><title>4. Emulation of Renewable Energy Sources in the Smart Grid</title><p>The cost optimization model has been executed into several steps in this section.</p><p>Step 1: The output power and cost calculation by MATLAB using an incremental cost function.</p><p>Step 2: This step has executed three case studies:</p><p>CASE 1: Dark lamp Manual synchronization to the grid for a pumped storage power plant to determine the pumped storage power plant’s specification.</p><p>CASE 2: Grid synchronization for a DFIGURE to determine the wind power plant’s specification.</p><p>CASE 3: Connection of hydro generator and wind generator to the grid to verify the MATLAB’ stated result.</p><p>Step 3: Comparison of the mathematical results to the practical results.</p><p>1) Step One:</p><p>In this experiment, the range is assumed for pumped storage generator output power from P<sub>1min</sub> = 10 W to P<sub>1max</sub> = 200 W. The range is considered for wind generator output power from P<sub>2min</sub> = 10 W to P<sub>2max</sub> = 150 W. Therefore, the minimum and maximum generated load power range for the combination of pumped storage power plant and wind power plant system is P<sub>L</sub><sub>min</sub> = 20 W to P<sub>L</sub><sub>max</sub> = 350 W.</p><p>The general cost C is considered as,</p><p>C = a P 2 + b P + c ; $ / h (4.1)</p><p>(with the consideration of no generator losses and limits) where a, b, and c also represent cost but in constant cost, which will not be considered to optimize in this study, and P is the generated power from the generator. The general cost is a function of output power of each power plant. The incremental cost of the two-power unit is a calculation of the slope of generating power and receiving the units’ power curves. This cost helps to determine the optimum combination of power productions that reduces the total energy. Then, incremental cost λ is,</p><p>λ = d C d P = 2 a P + b ; $ / W ⋅ h (4.2)</p><p>The general cost and incremental cost for a pumped-storage power plant is,</p><p>C 1 = a 1 P 1 2 + b 1 P 1 + c 1 ; $ / h (4.3)</p><p>λ 1 = d C 1 d P 1 = 2 a 1 P 1 + b 1 ; $ / W ⋅ h (4.4)</p><p>where a<sub>1</sub>, b<sub>1</sub>, and c<sub>1</sub> are considered as cost coefficients, P<sub>1</sub> is the output power from the pumped storage power plant.</p><p>The general cost and incremental cost for a wind power plant is,</p><p>C 2 = a 2 P 2 2 + b 2 P 2 + c 2 ; $ / h (4.5)</p><p>λ 2 = d C 2 d P 2 = 2 a 2 P 2 + b 2 ; $ / W ⋅ h (4.6)</p><p>where a<sub>2</sub>, b<sub>2</sub>, and c<sub>2</sub> are considered as cost coefficients, P<sub>2</sub> is the generated power from the wind power plant.</p><p>At optimum condition, λ 1 = λ 2 = λ (4.7a)</p><p>Equation (4.3) for the pumped storage power plant can be re-written as,</p><p>C 1 = 0.0041 P 1 2 + 0.8 P 1 + 40   $ (4.7b)</p><p>where, a<sub>1</sub> = 0.0041, b<sub>1</sub> = 0.8, the values are taken from [<xref ref-type="bibr" rid="scirp.109213-ref15">15</xref>]. As the machine under this experiment was in W, the power specification was scaled with W according to the test stand.</p><p>From Equation (4.4), the incremental cost,</p><p>λ 1 = 0.0082 P 1 + 0.8   $ / W ⋅ h (4.8)</p><p>Equation (4.5) for the wind power plant can be re-written as,</p><p>C 2 = 0.0065 P 2 2 + 1.4 P 2 + 19   $ (4.9)</p><p>where 0.0065 and 1.4 are represented as constant a<sub>2</sub> and b<sub>2</sub> respectively, the values are also taken from [<xref ref-type="bibr" rid="scirp.109213-ref15">15</xref>] As the machine under this experiment was in W, the power specification was scaled with W according to the test stand.</p><p>From Equation (4.6), incremental cost,</p><p>λ 2 = 0.013 P 2 + 1.4   $ / W ⋅ h (4.10)</p><p>As the minimum power for both of the power plant is 10 W, and substitute P<sub>1</sub> = 10 W in Equation (4.8) which gives λ 1 = 0.0082   $ / W ⋅ h and substitute P<sub>2</sub> = 10 W in Equation (4.10) which provides λ 2 = 1.53   $ / W ⋅ h .</p><p>It is observed that λ 1 &lt; λ 2 , which means that the incremental cost of pumped storage is less than the wind power plant’s incremental cost at minimum power generation of 10 W from both power plants. As the incremental cost of the wind power plant is higher than the pumped storage power plant during generating minimum power 10 W, keeping the output power of wind power plant P<sub>2</sub> = 10 W constant for the next step and calculate P<sub>1</sub> = 89 W when the system is in an optimum state, λ 1 = λ 2 = 1.53 from Equation (4.8). The next steps will continue by assuming various values of the output power of the pumped storage power plant P<sub>1</sub>, to calculate P<sub>2</sub>, P<sub>L</sub>, and incremental costs at optimum state λ 1 = λ 2 = λ . As mentioned before in this section, the maximum power is 200 W for pumped storage and 150 W for wind power plants. The same previous steps will continue to determine P<sub>2</sub>, P<sub>L</sub>, and incremental cost for assumed various P<sub>1</sub>; until each power plants reach their appointed assumed maximum power, 200 W for P<sub>1</sub> and 150 W for P<sub>2</sub>. <xref ref-type="table" rid="table1">Table 1</xref> contains all the calculated values of P<sub>2</sub>, P<sub>L</sub>, λ for various values of P<sub>1</sub> from the steps mentioned in <xref ref-type="table" rid="table1">Table 1</xref>.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Power and incremental cost at optimum condition</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >P<sub>1</sub><sub> </sub>(Output power from the pumped storage power plant)</th><th align="center" valign="middle" >P<sub>2</sub><sub> </sub>(Output power from the wind power plant)</th><th align="center" valign="middle" >P<sub>L</sub><sub> </sub>(Output power from the combined system)<sub> </sub></th><th align="center" valign="middle" >λ (Incremental cost)</th></tr></thead><tr><td align="center" valign="middle" >10 W</td><td align="center" valign="middle" >10 W</td><td align="center" valign="middle" >20 W</td><td align="center" valign="middle" >λ<sub>1</sub> = 0.882 $/Wh</td></tr><tr><td align="center" valign="middle" >89 W</td><td align="center" valign="middle" >10 W</td><td align="center" valign="middle" >99 W</td><td align="center" valign="middle" >λ<sub>1</sub> = λ<sub>2</sub> = 1.53 $/Wh</td></tr><tr><td align="center" valign="middle" >120 W</td><td align="center" valign="middle" >29.53 W</td><td align="center" valign="middle" >149.53 W</td><td align="center" valign="middle" >λ<sub>1</sub> = λ<sub>2</sub> = 1.784 $/Wh</td></tr><tr><td align="center" valign="middle" >140 W</td><td align="center" valign="middle" >42.153 W</td><td align="center" valign="middle" >182.153 W</td><td align="center" valign="middle" >λ<sub>1</sub> = λ<sub>2</sub> = 1.948 $/Wh</td></tr><tr><td align="center" valign="middle" >160 W</td><td align="center" valign="middle" >54.77 W</td><td align="center" valign="middle" >214.77 W</td><td align="center" valign="middle" >λ<sub>1</sub> = λ<sub>2</sub> = 2.112 $/Wh</td></tr><tr><td align="center" valign="middle" >180 W</td><td align="center" valign="middle" >67.38 W</td><td align="center" valign="middle" >247.38 W</td><td align="center" valign="middle" >λ<sub>1 </sub>= λ<sub>2</sub> = 2.276 $/Wh</td></tr><tr><td align="center" valign="middle" >200 W</td><td align="center" valign="middle" >80 W</td><td align="center" valign="middle" >280 W</td><td align="center" valign="middle" >λ<sub>1</sub> = λ<sub>2</sub> = 2.44 $/Wh</td></tr><tr><td align="center" valign="middle" >200 W</td><td align="center" valign="middle" >150 W</td><td align="center" valign="middle" >350 W</td><td align="center" valign="middle" >λ<sub>2 </sub>= 3.35 $/Wh</td></tr></tbody></table></table-wrap><p>Using all the values from <xref ref-type="table" rid="table1">Table 1</xref>, the optimum generated power combination of pumped storage plant, wind power plant, and the cost are determined by MATLAB shown in <xref ref-type="table" rid="table2">Table 2</xref>, where units 1 and 2 are named as pumped storage power plants and wind power plant.</p><p><xref ref-type="table" rid="table2">Table 2</xref> indicates the optimum point of the generated power, 88 W with 40.07 $ for the pumped storage power plant, and 33.994 W 19.048 $ for the wind power plant, and the total cost is 59.118 $.</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows the characteristics of output power (P<sub>1</sub>) of pumped storage plant versus incremental cost λ. Considering the power range 10 W &lt; P<sub>1</sub> &lt; 200 W. The curve is linear from 10 W to 200 W. After reaching 200 W, the incremental cost λ changes from 2.44 to 3.35 $/Wh. As a result, the generated power is constant at this point.</p><p><xref ref-type="fig" rid="fig7">Figure 7</xref> indicates the characteristics of output power (P<sub>2</sub>) generated from the wind power plant and the incremental cost λ considering the power range 10 W &lt; P<sub>1</sub> &lt; 150 W. The incremental cost λ is constant when P<sub>2</sub> = 10 W, whereas it starts to act as linearly from 10 W to 150 W with increasing incremental cost λ from 0.882 to 1.53 $/Wh.</p><p><xref ref-type="fig" rid="fig8">Figure 8</xref> shows the characteristics of the combined system’s load power (P<sub>L</sub>) versus incremental cost λ. This curve has three linear parts; first, the curve is linear from 10 to 100 W with increasing incremental cost λ. The second curve is linear from 100 W to approximately 280 W with increasing incremental cost λ, and the third one is linear from around 280 W to 350 W.</p><p>2) Step Two:</p><p>Three experiments were done in this step. They are given below:</p><p>CASE 1: Dark lamp Manual synchronization to the grid for pumped storage power plant</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> shows the connection of the pumped storage generator to the grid. The machine under test is operated in the “synchronization” mode in the servo machine test with 1800 rpm and 60 Hz frequency.</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The calculation from MATLAB</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Unit</th><th align="center" valign="middle" >Output Power (W)</th><th align="center" valign="middle" >Cost ($)</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >88</td><td align="center" valign="middle" >40.07</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >33.994</td><td align="center" valign="middle" >19.048</td></tr></tbody></table></table-wrap><p>A synchronous generator is used as a three-phase synchronous machine. When the speed is around 1800 rpm, the exciter voltage is 20 V, and consistent voltage is measured as 212 V. All the incandescent lamps started to get dark. The power switch of the synchronization unit has then connected the generator to the grid. Thus, the grid synchronization has been executed with the hydropower plant.</p><p>CASE 2: Grid synchronization for a DFIG</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>0 shows the connection of the wind generator to the grid. A doubly-fed asynchronous generator is used to control the variability of wind speed. “WindSim” software is used to emulate the system in real with a servo-machine test.</p><p>The generator is synchronizing with the rotor current and is set for a maximum of 0.21 A and frequency 60 Hz and variable speed from 210 to 217 V. Then, the generator automatically synchronizes with grid parameters.</p><p>CASE 3: The combined connection of hydro and wind generators to the grid</p><p>The synchronization of two renewable power stations together in the SMARTGRID has proposed to observe the optimum power with the SCADA system. This is the following steps of the previous case 1 and case 2. <xref ref-type="fig" rid="fig1">Figure 1</xref>1 shows that 2 bus-bar systems have been used, where bus 1 is represented as a slack bus. The hydropower plant and wind power plant are connected in parallel to the bus 2. The inductive load is connected through the transmission line.</p><p>Usually, the fluctuation rate of output power from the hydro-generator is less than the wind generator’s output power. Therefore, DFIGURE is used to generate power in power plants to avoid wind speed variability. <xref ref-type="fig" rid="fig1">Figure 1</xref>2 indicates the power flow of the system where the regulator helps regulate the generated wind power’s viability. Machine-side converters (MSC) and Line-side converters (LSC) are situated to minimize the faults due to wind power fluctuations. The SCADA system was used to control the power flow and reach the optimum generated</p><p>power from both generators individually, synchronized to the grid. <xref ref-type="fig" rid="fig1">Figure 1</xref>3 has displayed the schematic diagram of the system. Smart grid made SCADA system implemented, and SCADA contributed as an interface with industrial management. Also, this system is integrated by a soft PLC program.</p><p>The SCADA designer’s main function is to acquire data from the power plants to control the power plant. Sensors, RTU, and HMI, and the communication unit are the four components to interface with the industrial interface, collect and control the entire system’s data (<xref ref-type="table" rid="table3">Table 3</xref>).</p><p>Total power, P L = P 1 + P 2 ; P L = 88 + 34 = 122   W .</p><p>The combination of pumped storage and wind power plant has provided the optimum power 88 W and 34 W. The power output of the SCADA designer is matched with the output power from MATLAB.</p><p>3) Step Three: (<xref ref-type="table" rid="table4">Table 4</xref>)</p><p>According to the above cost, $88.76 was for 870 KWh, and the significant cost per KWh is $0.1020. In this work, the calculated cost of the output power from both generators is $59.118 per Wh is scaled into $0.0591 per KWh. In comparison to industry cost charged by actual electricity providers, it can be noted that</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Calculated parameters of pumped storage and wind power plant</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Values</th><th align="center" valign="middle" >Pumped Storage Power Plant</th><th align="center" valign="middle" >Wind Power Plant</th></tr></thead><tr><td align="center" valign="middle" >Active Power</td><td align="center" valign="middle" >88 W</td><td align="center" valign="middle" >34 W</td></tr><tr><td align="center" valign="middle" >Reactive Power</td><td align="center" valign="middle" >238 VAR</td><td align="center" valign="middle" >43 VAR</td></tr><tr><td align="center" valign="middle" >Apparent Power</td><td align="center" valign="middle" >256 VA</td><td align="center" valign="middle" >70 VA</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Cost comparison</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Amount in KWh</th></tr></thead><tr><td align="center" valign="middle" >Center point delivery fixed charge</td><td align="center" valign="middle" >$40.91</td></tr><tr><td align="center" valign="middle" >Energy charge for 870 KWh @ 0.0550/KWh</td><td align="center" valign="middle" >$47.85</td></tr><tr><td align="center" valign="middle" >Total cost for 870 KWh</td><td align="center" valign="middle" >$88.76</td></tr><tr><td align="center" valign="middle" >Effective cost per KWh</td><td align="center" valign="middle" >$0.1020</td></tr><tr><td align="center" valign="middle" >Optimized cost</td><td align="center" valign="middle" >$0.0591</td></tr></tbody></table></table-wrap><p>the optimized cost from this experiment is $0.0429/kwh or 42.05% lesser than the effective cost per kwh charged by Discount Power Energy Corporation (household electricity provider). Considering some other constraints in this work, such as generation limit, transmission losses may vary the system’s efficiency.</p><p>Significantly, there are few measures taken to optimize the cost by connecting hydroelectric and wind power together with Smart-Grid. At first, the values are taken when pumped storage is connected to the grid. After that, the values are again taken while the grid is associated with the wind power station. The cost was reduced when the combined pumped storage and wind power plant was linked to the grid. In this chapter, the calculations of each power plant are described.</p><p>The pumped storage power plant was primarily examined by achieving the manual synchronization to determine the exact point when synchronization occurs using control lamps and various measuring instruments like a dual-range voltmeter or a synchronoscope. The synchronization requires the same voltage phase angle, same sequence, and the same frequency, and for the parallel of the connection, the RMS voltages should be equal. A dual-range voltmeter is applied to compute the voltage, land the pre-set amplitude of the generated voltage was adjusted by exciting voltage. Also, a dual-range frequency meter is used to display the frequency.</p><p>The specification of individual power plants is achieved while the individual generators are connected. When the generators are individually connected, the power generation is low, 28 W, and 13 W for pumped storage and wind power plants. In contrast, the generated power of the combined system from each generator is 88 W and 34 W, respectively. The joint hydro-wind system can increase the generation of power. The unstable wind power was stable with the DC chopper, crowbar in the DFIG. With the limit consideration from 10 W &lt; P<sub>1</sub> &lt; 200 W for pumped storage power plant and 10 W &lt; P<sub>2</sub> &lt; 150 W for wind power stand, MATLAB is used to calculate the optimum power generation, which is 88 W for P<sub>1</sub> and 33.994 W for P<sub>2</sub>.</p></sec><sec id="s5"><title>5. Conclusions</title><p>This experiment is focused conducted to optimize the cost of power generation through pumped storage power plant and wind power plant. The entire modeling of cost optimization was conducted in two parts. The mathematical modeling was done using MATLAB simulation while the hydro and wind power plant’s emulation was performed using SCADA designer implementation. The experiment was conducted using ranges of generated power from both power sources. The optimum combination of output power and cost from both generators is determined via MATLAB simulation within the assumed generated output power range. The hydro-generator and wind generator’s emulation were executed individually through synchronizing the grid to determine each generator’s specification using SCADA designer, which provided the optimum power generation from both generators with the specific speed, aligning with results generated through MATLAB. DFIGURE was used to stabilize the unstable output power from the wind power plant. Combining the pumped-storage power plant and wind power plant’s generated power increases the system’s flexibility and reliability accordingly. Finally, the operational power cost (with no losses consideration) from MATLAB was compared with the local energy provider to determine the cost-efficiency.</p><p>Power optimization has also been achieved when the steady hydropower plant and wind power plant are connected to the grid instead of connecting individually by SCADA. The optimal combination of generated power by hydro-wind joint power plant minimizes the operational cost within the assumed output range of management resolving the multi-dimensional issue with SCADA by operating and controlling the power flow of the system. This experiment uniquely highlights the reliability, cost efficiency and advantageous utilization of SCADA’s functional efficiency, mainly in developing countries where it is crucial to reduce operational cost while maximizing power output.</p><p>Many sectors and specifications can be expanded to improve the cost optimization power system in the future. Connecting three power plants will possibly make a cost-effective plant instead of combining two power plants. Calculating the total cost, including operational cost and installation cost, need to be considered to develop the power system. Power loss may also be explored in the future. Future work can also explore the load curve for annual energy consideration with time. Besides, the capacitor’s injecting may improve the power factor that reduces the power system’s cost. Furthermore, artificial intelligence methods may be the next step as a genetic algorithm, PSO, to establish a more efficient power system.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Islam, N., Ali, W.H., Kolawole, E.S., Fuller, J., Obiomon, P., Attia, J.O. and Abood, S. (2021) Cost Optimization Modeling of Renewable Energy Sources in Smart-Grid Using SCADA. Communications and Network, 13, 51-67. https://doi.org/10.4236/cn.2021.132005</p></sec></body><back><ref-list><title>References</title><ref id="scirp.109213-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Y. and Shang, T. (2007) Economic Dispatch of Power System Incorporating Windpower Plant. The 8th International Power Engineering Conference (IPEC 2007), 159-163.</mixed-citation></ref><ref id="scirp.109213-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Qiu, W., Zhang, J.H. and Liu, N. (2011) Model and Solution for Environmental/Economic Dispatch Considering Large-Scale Wind Power Penetration. Proceedings of the CSEE, 31, 8-16.</mixed-citation></ref><ref id="scirp.109213-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Chen, D.J., Gong, Q.W., Qiao, H., et al. (2012) Multiobjective Generation Dispatching for Wind Power Integrated System Adopting Improved Biogeography-Based Optimization Algorithm. Proceedings of the CSEE, 32, 150-158.</mixed-citation></ref><ref id="scirp.109213-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Peng, C.H., Sun, H.J., Guo, J.F., et al. (2012) Dynamic Economic Dispatch for Wind-Thermal Power System Using a Novel Bi-Population Chaotic Differential Evolution Algorithm. International Journal of Electrical Power &amp; Energy Systems, 42, 119-126. https://doi.org/10.1016/j.ijepes.2012.03.012</mixed-citation></ref><ref id="scirp.109213-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Bayon, L., Grau, J.M. and Ruiz, M.M. (2012) The Exact Solution of the Environmental/Economic Dispatch Problem. IEEE Transactions on Power Systems, 27, 723-731. https://doi.org/10.1109/TPWRS.2011.2179952</mixed-citation></ref><ref id="scirp.109213-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yang, L.Q., Lin, S.J., Liu, M.B., et al. (2014) Multiobjective Dynamic Optimal Dispatch for Large-Scale Power Systems Considering Wind Power Penetration. Transactions of China Electrotechnical Society, 29, 286-295.</mixed-citation></ref><ref id="scirp.109213-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Narimani, H., et al. (2018) A Multi-Objective Framework for Multi-Area Economic Emission Dispatch. Energy, 154, 126-142.https://doi.org/10.1016/j.energy.2018.04.080</mixed-citation></ref><ref id="scirp.109213-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Azizivahed, A., Naderi, E., Karandeh, R., Cecchi, V., Li, L., Zhang, J.F., et al. (2020) Multi-Area Dynamic Economic Dispatch Considering Water Consumption Minimization, Wind Generation, and Energy Storage System. IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, 17-20 February 2020, 1-2. https://doi.org/10.1109/ISGT45199.2020.9087689</mixed-citation></ref><ref id="scirp.109213-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Yu, J., Ren, J.W. and Zhou, M. (2013) A Chance-Constrained Programming Based Dynamic Economic Dispatch of Wind Farm and Pumped-Storage Power Station. Journal of Power System Technology, 37, 1-3.</mixed-citation></ref><ref id="scirp.109213-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Li, H.L., Zhang, Z.Q. and Tang, X.J. (2015) Research on Optimal Capacity of Large Wind Power Considering Joint Operation with Pumped Hydro Storage. Power System Technology, 2746-2750.</mixed-citation></ref><ref id="scirp.109213-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, Y.F., Wei, H. and Hong, C.Q. (2011) Beqiun Hu andTaocheng. Modelization and Optimization of Multi-Type Power Generators Joint Scheduling Based on Improved PSO. National High Technology Research and Development Program of China, No. 2011AA.</mixed-citation></ref><ref id="scirp.109213-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Wang, S.X., Ju, L.W., Shang, J.C., et al. (2013) Optimization Model and Application of Combined Operation of Wind Power, Hydropower and Pumped Storage Power Stations in Energy-Saving Dispatching Environment. Hydropower Energy Science, 31, 46-50.</mixed-citation></ref><ref id="scirp.109213-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Xu, F., Chen, L., Jin, H.P., et al. (2013) Modeling and Application Analysis of Combined Operation of Pumped Storage Power Station and Wind Power. Automation of Electric Power System, 37, 149-154.</mixed-citation></ref><ref id="scirp.109213-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">You, W.-X., Wang, M.-M., et al. (2019) Research on Optimal Operation of Wind Power-Pumped Storage Joint System Based on Improved Bat Algorithm. International Conference on Intelligent Green Building and Smart Grid (IGBSG2019), Hubei, 6-9 September 2019, 538. https://doi.org/10.1109/IGBSG.2019.8886178</mixed-citation></ref><ref id="scirp.109213-ref15"><label>15</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Tankasala</surname><given-names> G.R. </given-names></name>,<etal>et al</etal>. (<year>2012</year>)<article-title>Artificial Bee Colony Optimisation for Economic Load Dispatch of a Modern Power System</article-title><source> International Journal of Scientific &amp; Engineering Research</source><volume> 3</volume>,<fpage> 3</fpage>-<lpage>4</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref></ref-list></back></article>