<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JPEE</journal-id><journal-title-group><journal-title>Journal of Power and Energy Engineering</journal-title></journal-title-group><issn pub-type="epub">2327-588X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jpee.2021.92001</article-id><article-id pub-id-type="publisher-id">JPEE-107311</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Research on Modeling and Control of a 100 kW Micro Bio-Gas Turbine
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiaotao</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiang</surname><given-names>Liu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Haoliang</surname><given-names>Mu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Wenxian</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Aijun</surname><given-names>Wang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Departments of Electric Power, North China University of Water Resources and Electric Power, Zhengzhou, China</addr-line></aff><pub-date pub-type="epub"><day>23</day><month>02</month><year>2021</year></pub-date><volume>09</volume><issue>02</issue><fpage>1</fpage><lpage>6</lpage><history><date date-type="received"><day>13,</day>	<month>January</month>	<year>2021</year></date><date date-type="rev-recd"><day>21,</day>	<month>February</month>	<year>2021</year>	</date><date date-type="accepted"><day>24,</day>	<month>February</month>	<year>2021</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In order to know about the influences of disturbance on the operating performance, the present work developed the overall dynamic simulation model of the micro gas turbine and investigated the control system under the disturbances of environmental temperature and unit load. The response processes of main parameters have been obtained. It found that the compressor pressure ratio and the fuel flow rate increase in the case of natural gas being replaced by pine gas. When the system reaches a new steady state, the main parameters change to different values. The output power decreases with the declining of the air mass flow when the ambient temperature rises, the biomass gas mass flow rate increases under the regulation of the control system to maintain the output power and rotating speed in which the thermal efficiency reduces by 1.40%. The thermal efficiency enhances with the increase of output load. The control system can quickly and effectively act to maintain the key parameters at desired value.
 
</p></abstract><kwd-group><kwd>Micro Gas Turbine</kwd><kwd> Biomass Gas</kwd><kwd> Overall Model</kwd><kwd> Turbine Control System</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Micro gas turbines with 25 kW to 300 kW output power have the advantages of good stability, strong fuel adaptability, and low pollution [<xref ref-type="bibr" rid="scirp.107311-ref1">1</xref>]. Biomass gas has been applied to mcro gas turbines. Aiguo Liu et al. [<xref ref-type="bibr" rid="scirp.107311-ref2">2</xref>] proposed adjustments and improvements for low-calorific value’s biomass gas. Homam Nikpey Somehsaraei [<xref ref-type="bibr" rid="scirp.107311-ref3">3</xref>] and Qianqian Zhang et al. [<xref ref-type="bibr" rid="scirp.107311-ref4">4</xref>] studied the performance of biogas micro gas turbines and calculated the safe operating conditions of micro gas turbine when different biomass gas was applied.</p><p>When natural gas is used as micro gas turbine’s fuel, Jiandong Duan et al. [<xref ref-type="bibr" rid="scirp.107311-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.107311-ref6">6</xref>] proposed a load feed-forward control to shorten the adjustment time. Ebrahim Najimi et al. [<xref ref-type="bibr" rid="scirp.107311-ref7">7</xref>] studied a method applied to micro gas and the result showed that this control reduced the maximum amplitude of the speed deviation. Ying Shi et al. [<xref ref-type="bibr" rid="scirp.107311-ref8">8</xref>] showed that the controller has good stability and flexibility when the load disturbance changes suddenly. Jiandong Duan et al. [<xref ref-type="bibr" rid="scirp.107311-ref9">9</xref>] proposed two coordinated control methods for hybrid power generation systems and predicted the output power of a micro-gas turbine.</p><p>In this paper, the biomass gas micro turbine overall model is built and the control system under the disturbances of environmental temperature and unit load are studied. The responses processes of main parameters have been obtained. It will provide reference data for the response research of biogas-fired micro gas turbine under different disturbances.</p></sec><sec id="s2"><title>2. Biogas-Fired Micro Gas Turbine Model and Performance Analysis</title><p>The biomass gas micro turbine mainly includes modules such as compressor, combustor, turbine and generator. The flowchart is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>The air is compressed to high-pressure by a compressor. In the combustor, the biomass gas combusts with air and produces high-temperature and high-pressure flue gas, then drives the turbine-generator to do work and to generate electricity.</p><p>The biomass gas is used as micro gas turbine’s feed fuel, which is different from natural gas. The calorific value of biomass gas is much lower, at the same power generation capacity, the needed biomass gas mass flow will increase. And the combustion products are also different from the natural gas combustion, which result in the different specific heat capacity of the flue gas and thus the work done by the turbine changes accordingly.</p><sec id="s2_1"><title>2.1. Model Validation</title><p>Based on the basic parameters of T100 and the natural gas as feed-fuel, the main results from the simulation model are compared with the initial data and the comparison results of both types of fuel are shown in <xref ref-type="table" rid="table1">Table 1</xref>. When the fuel is</p><p>changed to pine gas, it is necessary to make appropriate adjustments to the micro gas turbine to ensure that the flue gas flow rate is 0.79 kg∙s<sup>−1</sup> and the unit rated power is 100 kW. The error of the output power is less than 5%, and the other errors are also within the allowable range. The built model is reasonable. The fuel flow rate and the compressor pressure ratio increase to 0.118 kg∙s<sup>−1</sup>and 5.218 respectively, but both the compressor efficiency and the turbine efficiency decrease slightly.</p></sec><sec id="s2_2"><title>2.2. Control System of Micro Gas Turbine</title><p>The gas turbine control system includes the speed control system, temperature control system and acceleration control system. These three types of control will generate the corresponding fuel reference value, and the minimum value output is selected by the minimum value selector. The overall schematic diagram of the micro gas turbine control system is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Comparisons of basic parameters of T100 and simulation results</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >System parameters</th><th align="center" valign="middle" >Basic parameters of T100 (natural gas)</th><th align="center" valign="middle" >Simulation results (natural gas)</th><th align="center" valign="middle" >Simulation results(pine gas)</th></tr></thead><tr><td align="center" valign="middle" >Compressor pressure ratio</td><td align="center" valign="middle" >4.5</td><td align="center" valign="middle" >4.5</td><td align="center" valign="middle" >5.218</td></tr><tr><td align="center" valign="middle" >Compressor efficiency (%)</td><td align="center" valign="middle" >81.30</td><td align="center" valign="middle" >81.30</td><td align="center" valign="middle" >78.27</td></tr><tr><td align="center" valign="middle" >Fuel flow (kg∙s<sup>−1</sup>)</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.118</td></tr><tr><td align="center" valign="middle" >Outlet temperature of combustor (K)</td><td align="center" valign="middle" >1223</td><td align="center" valign="middle" >1188</td><td align="center" valign="middle" >1220</td></tr><tr><td align="center" valign="middle" >Turbine exhaust temperature (K)</td><td align="center" valign="middle" >923</td><td align="center" valign="middle" >858.6</td><td align="center" valign="middle" >888.5</td></tr><tr><td align="center" valign="middle" >Turbine efficiency (%)</td><td align="center" valign="middle" >82</td><td align="center" valign="middle" >81.92</td><td align="center" valign="middle" >79.83</td></tr><tr><td align="center" valign="middle" >Flue gas flow (kg∙s<sup>−1</sup>)</td><td align="center" valign="middle" >0.79</td><td align="center" valign="middle" >0.79</td><td align="center" valign="middle" >0.79</td></tr><tr><td align="center" valign="middle" >Unit rated power (kW)</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >102</td><td align="center" valign="middle" >101.2</td></tr></tbody></table></table-wrap></sec></sec><sec id="s3"><title>3. Simulation Results</title><sec id="s3_1"><title>3.1. Ambient Temperature Disturbance</title><p>In the condition of ambient temperature disturbance, the simulation results are shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p>When the ambient temperature steps from 15˚C to 25˚C, the speed of the unit decreases to 999.7 rad&#183;s<sup>−1</sup>. Under the adjustment of the control system, the fuel input is increased, and then the speed increases quickly, and goes up to its initial</p><p>value, then it is gradually adjusted to a new steady state. The unit output power has an inverse process with speed. The biomass gas mass flow rises to the maximum value of 1.02, then declines and stays constant. The outlet temperature of the combustor and exhaust gas temperature of the turbine have the same processes. But the thermal efficiency reduces to 0.9588, about 1.4% relatively. It showed that the control system can quickly and effectively act to maintain the key parameters such as output load, rotating speed at rated value.</p></sec><sec id="s3_2"><title>3.2. Load Disturbance</title><p>When the input load steps 20%, the simulation results are shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>It showed that the output load can rapidly follow the demand and become stable under the regulation of the control system. The fuel flow rate and the thermal efficiency increase obviously with a slight rotating speed offset.</p></sec></sec><sec id="s4"><title>4. Conclusions</title><p>1) The fuel flow rate and the compressor pressure ratio increase to keep the output power constant when the fuel is changed from natural gas to pine gas, but the compressor efficiency and turbine efficiency decrease slightly.</p><p>2) The output power and the thermal efficiency decrease on condition that the ambient temperature rises. The biomass gas mass flow should be increased though action of the control system. Micro gas turbines are sensitive to change of the ambient temperature.</p><p>3) When the micro gas turbine has load disturbance, the control system mainly adjusts the fuel flow to make the micro gas turbine reach a new equilibrium state to meet the operating requirements. And the performance of micro gas turbine has been enhanced.</p><p>4) The control system works effectively and speedily to overcome various disturbances to maintain the key operating indexes at desired value.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This work was supported by the key scientific research project of Henan Provincial Colleges and Universities: 21A480006.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Zhang, X.T., Liu, X., Mu, H.L., Zhang, W.X. and Wang, A.J. (2021) Research on Modeling and Control of a 100 kW Micro Bio-Gas Turbine. Journal of Power and Energy Engineering, 9, 1-6. https://doi.org/10.4236/jpee.2021.92001</p></sec></body><back><ref-list><title>References</title><ref id="scirp.107311-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Duan, J.D., Liu, J.J., Xiao, Q., Fan, S.G., Sun, L. and Wang, G.L. (2019) Cooperative Controls of Micro Gas Turbine and Super Capacitor Hybrid Power Generation System for Pulsed Power Load. Energy, 169, 1242-1258. https://doi.org/10.1016/j.energy.2018.12.004</mixed-citation></ref><ref id="scirp.107311-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Shi, Y., Zhu, L.J., Ren, J.P. and Sun, F.H. (2015) Research of Microturbine Power Generation System Based on Fuzzy PID Control. Industry and Mine Automation, 41, 84-87.</mixed-citation></ref><ref id="scirp.107311-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Najimi, E. and Ramezani, M.H. (2012) Robust Control of Speed and Temperature in a Power Plant Gas Turbine. ISA Transactions, 51, 304-308. https://doi.org/10.1016/j.isatra.2011.10.001</mixed-citation></ref><ref id="scirp.107311-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Rowen, W.I. (1983) Simplified Mathematical Representations of Heavy-Duty Gas Turbines. Journal of Engineering for Gas Turbines and Power, 105, 865-869. https://doi.org/10.1115/1.3227494</mixed-citation></ref><ref id="scirp.107311-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Duan, J.D., Sun, D.Y., Wu, F.J., Zhao, K. and Sun, L. (2013) Optimal Efficiency Operation and Overall Operating Condition State Feedback Control of Microturbine. Electric Machines and Control, 17, 47-54.</mixed-citation></ref><ref id="scirp.107311-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Q.Q., Bo, Z.M., Sang, Z.K. and Weng, Y.W. (2016) Analysis on Operating Characteristics of Biogas-Fired Micro Gas Turbine. Journal of Engineering for Thermal Energy and Power, 31, 44-49 + 137-138.</mixed-citation></ref><ref id="scirp.107311-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Somehsaraei, H.N., Majoumerd, M.M., Breuhaus, P. and Assadi, M. (2014) Performance Analysis of a Biogas-Fueled Micro Gas Turbine Using a Validated Thermodynamic Model. Applied Thermal Engineering, 66, 181-190. https://doi.org/10.1016/j.applthermaleng.2014.02.010</mixed-citation></ref><ref id="scirp.107311-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Liu, A.G., Weng, Y.W., Weng, S.L. and Zhang, W. (2009) Influence of Low-Heating-Value Fuels on the Operating Characteristics of a Miniature Gas Turbine. Journal of Engineering for Thermal Energy and Power, 24, 230-235 + 268-269.</mixed-citation></ref><ref id="scirp.107311-ref9"><label>9</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Wu</surname><given-names> S. </given-names></name>,<etal>et al</etal>. (<year>2019</year>)<article-title>Research on the Characteristics of Micro Gas Turbine Technology and Its Prospects in the Field of Distributed Generation</article-title><source> Telecom Power Technology</source><volume> 36</volume>,<fpage> 45</fpage>-<lpage>48</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref></ref-list></back></article>