<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AMI</journal-id><journal-title-group><journal-title>Advances in Molecular Imaging</journal-title></journal-title-group><issn pub-type="epub">2161-6728</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ami.2021.111001</article-id><article-id pub-id-type="publisher-id">AMI-107209</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Computer Science&amp;Communications</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Tracking of Labelled Stem Cells Using Molecular MR Imaging in a Mouse Burn Model &lt;i&gt;in Vivo&lt;/i&gt; as an Approach to Regenerative Medicine
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zeba</surname><given-names>Qadri</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Valeria</surname><given-names>Righi</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shasha</surname><given-names>Li</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>A.</surname><given-names>Aria Tzika</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>MGH NMR Surgical Laboratory, Center for Surgery, Innovation and Bioengineering, Department of Surgery, 
Massachusetts General and Shriners Burn Hospitals, Harvard Medical School, Boston, USA</addr-line></aff><aff id="aff2"><addr-line>Athinoula A. Martinos Center of Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, 
Harvard Medical School Charlestown, USA</addr-line></aff><pub-date pub-type="epub"><day>29</day><month>01</month><year>2021</year></pub-date><volume>11</volume><issue>01</issue><fpage>1</fpage><lpage>15</lpage><history><date date-type="received"><day>25,</day>	<month>November</month>	<year>2020</year></date><date date-type="rev-recd"><day>26,</day>	<month>January</month>	<year>2021</year>	</date><date date-type="accepted"><day>29,</day>	<month>January</month>	<year>2021</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Therapies based on stem cell transplants offer significant potential in the field of regenerative medicine. Monitoring the fate of the transplanted stem cells in a timely manner is considered one of the main limitations for long-standing success of stem cell transplants. Imaging methods that visualize and track stem cells
   in vivo non-invasively in real time are helpful towards the development of successful cell transplantation techniques. Novel molecular imaging methods which are non-invasive particularly such as MRI have been of great recent interest. Hence, mouse models which are of clinical relevance have been studied by injecting contrast agents used for labelling cells such as super-paramagnetic iron-oxide (SPIO) nanoparticles for cellular imaging. The MR techniques which can be used to generate positive contrast images have been of much relevance recently for tracking of the labelled cells. Particularly when the off-resonance region in the vicinity of the labeled cells is selectively excited while suppressing the signals from the non-labeled regions by the method of spectral dephasing. Thus, tracking of magnetically labelled cells employing positive contrast
   in vivo MR imaging methods in a burn mouse model in a non-invasive way has been the scope of this study. The consequences have direct implications for monitoring labeled stem cells at some stage in wound healing. We suggest that our approach can be used in clinical trials in molecular and regenerative medicine.
 
</p></abstract><kwd-group><kwd>Burn Wounds</kwd><kwd> Cell Labeling</kwd><kwd> Cell Tracking</kwd><kwd> Cellular Imaging</kwd><kwd>  Magnetic Resonance</kwd><kwd> Imaging (MRI)</kwd><kwd> Molecular Imaging</kwd><kwd> Positive Contrast  Imaging</kwd><kwd> Stem Cells</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Stem cells (SCs) are a group of undifferentiated pluripotent cells characterized by the aid of the capability to undergo self-renewal as well as differentiation into various other tissue types which in turn depends on what type of tissues they have been derived from [<xref ref-type="bibr" rid="scirp.107209-ref1">1</xref>]. SCs can be of embryonal origin in which case the embryonal SCs are derived from embryonal tissue. On the other hand SCs can also be of adult origin, and can be derived from adult germ cells [<xref ref-type="bibr" rid="scirp.107209-ref2">2</xref>]. Adult SCs are derived from adult tissues of different organs consisting of intestines and bone marrow, which are taken into consideration to have excessive turnover [<xref ref-type="bibr" rid="scirp.107209-ref2">2</xref>].</p><p>Though in general SCs have been implicated in the facilitation of wound healing, nevertheless the satisfaction is yet to be found concerning the usage of stem cell therapy [<xref ref-type="bibr" rid="scirp.107209-ref3">3</xref>]. Substantial studies using SCs are being carried out with promising effects in various fields ranging from wound healing, hematologic diseases, oncologic diseases, organ transplants and so forth. The potential clinical application of different types of SCs has been reported for specific varieties of wounds in the field of wound healing [<xref ref-type="bibr" rid="scirp.107209-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref6">6</xref>] with a special interest in burning wounds [<xref ref-type="bibr" rid="scirp.107209-ref3">3</xref>]. The use of mesenchymal bone marrow derived stem cells (BMSCs) for burn wound recovery in rats, as stated through Shumakov et al. [<xref ref-type="bibr" rid="scirp.107209-ref7">7</xref>] had been the first to use stem cells in the area of burn wound healing. Rasulov et al. [<xref ref-type="bibr" rid="scirp.107209-ref8">8</xref>] had been the first who applied SCs onto the burn surface by using BMSCs in humans and also showed that the application of SCs results in a quicker healing of wounds [<xref ref-type="bibr" rid="scirp.107209-ref8">8</xref>]. Some other observations on rats also supported the fact that stem cells are a superior choice in the healing of burn wounds [<xref ref-type="bibr" rid="scirp.107209-ref9">9</xref>]. Further it is added that use of mesenchymal SCs on burn wounds improves formation of blood vessels and decreases unusual growth of cells [<xref ref-type="bibr" rid="scirp.107209-ref9">9</xref>].</p><p>So far research has highlighted the position of SCs in the process of wound recuperation. Burn wound recovery has also been a subject of additional focus. However, SC application to burn wounds comprises of various methods [<xref ref-type="bibr" rid="scirp.107209-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref12">12</xref>], These strategies may include local or IV injections or topical application. Due to properties like self-renewal and migration which are of utmost importance for wound healing treatment options based on SCs keep top notch guarantees in regenerative medicinal drug [<xref ref-type="bibr" rid="scirp.107209-ref7">7</xref>] - [<xref ref-type="bibr" rid="scirp.107209-ref12">12</xref>].</p><p>In order to understand the utility of SC technology in the treatment of burn wounds theirin vivo tracking over time becomes crucial. Also, to understand the repair work tracking and quantification of SCs is critical. Labeling of cells is essential to tune their migration and differentiation via imaging post-transplantation. Cells can be labeled by means of direct or oblique techniques. In the direct methods there are no modifications of the genetic material of the cell. On the other hand, the oblique methods of cell labeling require alterations of the genetic material. This is carried out by the introduction of a reporter gene into the genetic material which is a more complicated process. Hence, direct labeling methods are preferred and are more common. Direct labeling is done by delivering a labeling agent into the cell. This is followed by the transplantation of the labeled cells. These transplanted cells are then imaged indirectly [<xref ref-type="bibr" rid="scirp.107209-ref13">13</xref>]. Labeling agents can be classified on the basis of imaging modalities to be used [<xref ref-type="bibr" rid="scirp.107209-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref15">15</xref>]. These include fluorochromes for optical fluorescence imaging, radioactive nuclides for positron emission tomography (PET) or single photon emission computed tomography (SPECT), paramagnetic and super-paramagnetic iron oxide (SPIO) particles for MRI [<xref ref-type="bibr" rid="scirp.107209-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref18">18</xref>]. Of all the listed labeling agents the MR contrast agents have some advantages because they provide simple, faster, effective and long-term tracking of the cells involved in the healing process. Because of these properties the MR labeling agents [<xref ref-type="bibr" rid="scirp.107209-ref19">19</xref>]. Considering the extremely hard work being carried out to improve cellular imaging techniques, MRI has the advantage of better resolution over optical imaging. MRI also has an added advantage of anatomical information of high spatial resolution over PET [<xref ref-type="bibr" rid="scirp.107209-ref20">20</xref>].</p><p>MRI being one among the sophisticated and non-invasive techniques that visualize the internal structures of the body in healthy as well as diseased conditions. It provides better resolution and contrast for soft tissues. It doesn’t involve any harmful radiations and exhibits low toxicity. It has as a result been used as a diagnostic device, with a wide range of medical applications, for over three decades now [<xref ref-type="bibr" rid="scirp.107209-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref23">23</xref>]. MRI is a spectroscopic technique which depends on the quantum mechanical spin properties of the hydrogen nuclei which results in a magnetic moment. Under the influence of a strong applied magnetic field the magnetic moments of those nuclei align with the applied magnetic field. Upon the application of an RF pulse the nuclei get excited to the higher spin energy state. This is followed by relaxation to the lower spin energy state. During the relaxation to the equilibrium state the absorbed energy is again released in the form of an RF signal which is detected and subsequently processed resulting in the generation of a cross-sectional anatomical image.</p><p>The idea at the back of the anatomical images furnished with the aid of MRI is T<sub>1</sub> (water spin-lattice or longitudinal) and T<sub>2</sub> (water spin-spin or transverse) <sup>1</sup>H relaxation processes of water found in soft tissues [<xref ref-type="bibr" rid="scirp.107209-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref25">25</xref>]. Many times the endogenous MR differences due to inherent relaxation variations among various sorts of tissues may not be enough to develop an image contrast. For this reason, an exogenous contrast agent (CA) is regularly utilized in MRI to provide additional assessment to differentiate a target tissue from its surroundings. With the aid of the use of MRI contrast agents the assessment of images and subsequently the visibility of specific anatomical structures may be progressed. While employing Magnetic Resonance Imaging, cells are labeled with an appropriate contrast agent. Further research in this area made the use of these contrast agents feasible for labeling of specific cell types [<xref ref-type="bibr" rid="scirp.107209-ref26">26</xref>] - [<xref ref-type="bibr" rid="scirp.107209-ref36">36</xref>]. Regenerative medicine research field has been benefited using MRI forin vivo imaging and tracking of engrafted SCs. MRI has also proved to be useful to observe the physiological responses in a safe and non-invasive way.</p><p>The metal ions present in the MR contrast agents exhibit characteristic relaxation enhancements. These agents catalytically shorten the relaxation times (T<sub>1</sub> &amp; T<sub>2</sub>) of nearby tissue water protons to various degrees relying on their nature, making them discernible on post-contrast MRI. For cell labeling and cell tracking the MR contrast agents used are of the following types: 1) paramagnetic agents [<xref ref-type="bibr" rid="scirp.107209-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref28">28</xref>]; 2) super paramagnetic agents [<xref ref-type="bibr" rid="scirp.107209-ref29">29</xref>]; and 3) contrast agents that contain nuclei other than hydrogen [<xref ref-type="bibr" rid="scirp.107209-ref30">30</xref>] - [<xref ref-type="bibr" rid="scirp.107209-ref36">36</xref>].</p><p>Paramagnetic contrast agents create a magnetic moment which decreases the longitudinal relaxation time (T<sub>1</sub>) and the transverse relaxation time (T<sub>2</sub>) of the surrounding water protons through more or less the same quantity. Those contrast agents which exhibit a positive contrast are known as T1 agents. A positive contrast refers to a bright image quality. The signal thus obtained is referred to as T1 weighted. But the major disadvantage of paramagnetic agents in cell tracking is that the signal drops off with decreasing number of labeled cells. On the other hand, super-paramagnetic contrast agents such as SPIO nanoparticles lowers the transverse relaxation time (T2) to a far greater extent and are known as negative contrast agents which produce darker image quality [<xref ref-type="bibr" rid="scirp.107209-ref37">37</xref>].</p><p>In vivo MR imaging of SPIO labeled cells is generally carried out using gradient- or spin-echo sequences for T<sub>2</sub>- or T 2 * -weighted negative-contrast [<xref ref-type="bibr" rid="scirp.107209-ref38">38</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref39">39</xref>]. Negative contrast methods function by imaging the accumulated SPIO nanoparticles via loss of signal intensity due to strong T 2 * dephasing which is induced by the local presence of super-paramagnetic nanoparticles. This makes quantification of signal loss difficult especially in regions of high concentrations of SPIO due to low signal to noise ratio (SNR) as a result of dephasing. To avoid the signal loss positive contrast MR imaging is a better option to negative contrast. This is done by exploiting the chemical shifts induced by SPIO in neighboring water molecules. There are various strategies for the generation of a positive contrast. These methods make use of specially designed pulses to bring about the refocusing of the water signals in the vicinity of the SPIO particles [<xref ref-type="bibr" rid="scirp.107209-ref40">40</xref>]. The responsiveness of SPIO particles towards MRI is much stronger as compared to the paramagnetic agents. These SPIO particles tend to induce a local field inhomogeneity, which gives rise to a dipolar magnetic field large enough to cause signal spin-spin dephasing [<xref ref-type="bibr" rid="scirp.107209-ref41">41</xref>]. This gives rise to a negative contrast on T2-weighted MRI and with high local concentrations of the superparamagnetic contrast agents may produce a complete signal void. This situation could be overcome if the imaging contrast is provided by transverse (T<sub>2ρ</sub>) relaxation in the rotating frame [<xref ref-type="bibr" rid="scirp.107209-ref42">42</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref43">43</xref>] which could be achieved through the application of a spin-lock RF (radio-frequency) pulse, which together with the static magnetic field results in an effective field. This situation may be conquered if the imaging evaluation is carried out via Off-Resonance Imaging (ORI) (44) therefore developing a positive (bright) contrast.</p><p>Non-invasive techniques for molecular imaging involving novel strategies making use of SPIO nanoparticles have been of recent interest [<xref ref-type="bibr" rid="scirp.107209-ref45">45</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref46">46</xref>], but there are several techniques which help in generating tremendous positive contrast of the magnetically labelled cells. This is brought into effect by selective spectral excitation of an off-resonance region in the vicinity of the labelled cells [<xref ref-type="bibr" rid="scirp.107209-ref40">40</xref>]. During this process the signals from the non-labeled regions are suppressed [<xref ref-type="bibr" rid="scirp.107209-ref47">47</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref48">48</xref>]. The tracking of SCs labelled with SPIO in a burn mouse model will be addressed here in particular employing non-invasivein vivo MR methods for generating positive contrast imaging (Schematic is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>).</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>Mice: Five GFP+ mice (28 - 30 g) were used to carry out the studies. An i.p. injection of 40 mg/kg pentobarbital sodium was injected into the hind limb the mice for anesthetizing it. The mice were subjected to scald injury of non-lethal nature, representing merely 3% - 5% of the total body surface area, by immersion in 90˚C water for a time period of about 9 sec [<xref ref-type="bibr" rid="scirp.107209-ref49">49</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref50">50</xref>]. According to requirements s.c. buprenorphine at 0.05 - 0.1 mg/kg, was provided as an analgesic.</p><p>Isolation and preparation of stem cells (BMSCs): Mesenchymal stem cells (multipotent stem cells which can easily differentiate to keratinocytes and epidermis) were isolated from bone marrow and confirmed their characteristics with flow cytometry. GFP+ mesenchymal stem cell lines were obtained from Tulane University. Cells were proliferated under conditions that keeps them proliferating without changing their surface markers (and state of differentiation). The isolated cells showed MSC markers and could be differentiated from different cell lines in vitro.</p><p>Labellingof BMSCs, histology and optimization: The GFP+ multipotent cell line (BMSCs) isolated from bone marrow of GFP+ mice were labeled with the help of Ferumoxide-protamine sulphate (Fe-Pro) complexes (around 10 μg intracellular iron) which is a type of synthetic SPIO. These magnetically labelled BMSCs were then injected into the mice to serve the purpose of a molecular imaging MRI contrast agent. Hydrochloric acid and Potassium ferrocyanide were</p><p>used in combination with Spectrophotometric methods for determining the “Mean Intracellular Iron” in the labelled cells [<xref ref-type="bibr" rid="scirp.107209-ref51">51</xref>]. After 48 to 72 hours of the thermal injury about 3 million MSCs were injected into the mice intravenously. These cells could be tracked with MRI and fluorescent microscope and we could show the migration of stem cells to the area of interest.</p><p>Imaging: After 48 hours of the IV injection comprising of the iron labelled MSCs two mice were scanned in a 4.7 T horizontal bore magnet (20 cm bore diameter, Magnex Scientific, using a Bruker Avance console). While imaging the mice both positive and negative contrasts MR images were acquired. The Positive contrast MR method was employed using an off-resonant imaging (ORI) technique [<xref ref-type="bibr" rid="scirp.107209-ref44">44</xref>] implemented in a RARE (Rapid Imaging with Refocused Echoes) [<xref ref-type="bibr" rid="scirp.107209-ref52">52</xref>] sequence with RARE acceleration factor two. The ORI-T<sub>2ρ</sub> technique (schematic shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>, as adapted from Andronesi et al. [<xref ref-type="bibr" rid="scirp.107209-ref53">53</xref>] was chosen to implement in a RARE sequence. An acceleration factor of two was achieved via the insertion of an MLEV-4 block. The HS4 adiabatic pulses constitute the MLEV-4 block for attaining relaxation in the rotating frame [<xref ref-type="bibr" rid="scirp.107209-ref52">52</xref>]. The optimization of the RF amplitude and that of the adiabatic pulses in the ORI-T2ρ for setting the mixing time had been done forin vivo imaging of the mice [<xref ref-type="bibr" rid="scirp.107209-ref53">53</xref>]. Ten-lobed sinc pulses for selective water (400 Hz bandwidth) and fat (800 Hz bandwidth) suppression were applied. This was followed by decohering the transverse magnetization through spoiling gradients. Following the water and fat suppression pulses as mentioned a spin-echo imaging sequence was applied. A negative</p><p>contrast was achieved with a series of FLASH (Fast Low-Angle SHot) [<xref ref-type="bibr" rid="scirp.107209-ref54">54</xref>] images. Increased echo-time was used to achieve negative contrast. For the T 2 * weighting typical values α = 15˚, TR = 500 ms, TE = 4, 6, 8, 12, 14 ms (<xref ref-type="fig" rid="fig2">Figure 2</xref>) were employed. For each mouse the total MRI scan time was 2.5 h approximately. Two weeks after imaging the mice were euthanized for performing histology studies. Prussian blue staining of iron labelled cells was done for histochemical determination. One week later after the first analysis the same experiment was repeated for the second mouse.</p></sec><sec id="s3"><title>3. Results</title><p>Ten axial slices of 1 mm thickness, 1.5 mm gap, 3 &#215; 3 cm FOV, 128 &#215; 128 matrix size and 8 averages were acquired during the MRI scan. Thein vivo MR images of the labeled SCs in the burn vicinity are shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. For the demonstrative slices positive-contrast images with pseudocolor were obtained which have been shown to superimpose on the proton-density weighted anatomical images from the imaged mice. Images resulting from ORI-T2ρ as well as ORI schemes were converted to SNR images. The threshold SNR level for these images was kept the same so that it could be used as a foundation for comparison for both the protocols employed for MRI. In both the mice similar slices were taken from</p><p>the same anatomical location. MR images were taken 24 h after the IV SC injection as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, panel 1 and those of a week later are shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, panel 2.</p><p>The positive-contrast images were thresholded to signal &gt;3 in dimensionless units of SNR and were superimposed on a T1-weighted FLASH image and presented in pseudo color. In <xref ref-type="fig" rid="fig3">Figure 3</xref> from left to right, images are: (a) ORI, (b) ORI-T<sub>2</sub><sub>ρ</sub>, (c) FLASH (TE = 4 msec), (d) FLASH (TE = 14 msec). Image processing (<xref ref-type="fig" rid="fig3">Figure 3</xref>) was carried out by drawing around the area of the burn for selecting regions of interest (ROI) and integrating the total (thresholded) signal intensity within each ROI. The histology for the injected SPIO labeled MSCs (blue) was done manually by counting the number of stained (with Prussian blue) and unstained cells under a microscope. he effectiveness of the labeling methods was found to be greater than 95%.In vivo MRI tracking of these labeled SCs was done non-invasively with a high degree of sensitivity and specificity. Our results thus showed the efficient labeling of MSCs with ferumoxides-protamine sulfate complexes.</p></sec><sec id="s4"><title>4. Discussion</title><p>In the current effort we geared in the direction of refining the specificity for SPIO detection. The possible applications of SCs in the process of treatment of burn injuries and how the healing progress can be monitored have been presented in this study. In numerous cases the approaches above are not always specific to SPIO and either negative- or positive- contrast like sections appear in places where it is not anticipated.</p><p>The MR images evidently showing the relocation and gathering of the iron labelled SCs to the area of the burn injury (<xref ref-type="fig" rid="fig3">Figure 3</xref>, panels 1(a) &amp; 1(b)) constitutes the major finding of this study. The relocation of the iron labeled SCs was confirmed with the aid of histology staining using Prussian blue as shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>. The studies shown corroborate Dr. Alan Fischman’s findings [<xref ref-type="bibr" rid="scirp.107209-ref55">55</xref>] but his work makes use of radioactivity. Ours is non-irradiating, the cells may well be traced non-invasively with high sensitivity and specificityin vivo, which is a primary advantage of MRI, over nuclear medicine methods [<xref ref-type="bibr" rid="scirp.107209-ref56">56</xref>] [<xref ref-type="bibr" rid="scirp.107209-ref57">57</xref>]. When MRI was performed after one week of injection of iron labeled MSCs to check if they could still be found in the burn area, positive contrast method did not reveal any which was then confirmed by T 2 * weighted MR images with varying echo times.</p><p>We posit that the imaging of magnetic nanoparticles with positive contrast techniques, such as ORI, has the potential to turn out to be an exceedingly beneficial tool in cell tracking and molecular imaging. We have used the current method before to image burn and our findings here extend our previous findings (Andronesi et al.) [<xref ref-type="bibr" rid="scirp.107209-ref53">53</xref>]. Magnetically labeled SCs with a high concentration of nanoparticles [<xref ref-type="bibr" rid="scirp.107209-ref9">9</xref>], and accumulated endogenous ferritin [<xref ref-type="bibr" rid="scirp.107209-ref8">8</xref>], have already been successfully imaged with these strategies at 1.5 T. Imaging at 1.5 T lacks detail</p><p>due to low sensitivity and specificity. However, ORI have been used for different field strengths. These studies play an important role for assessing the prospect of ORI in imaging the iron labelled regions at high fields in order to attain higher resolution. For sensing lower and diffuse concentrations of iron also these studies are useful. The analytic precision of ORI shows a non-linear response with the increase in the concentration of the nanoparticle [<xref ref-type="bibr" rid="scirp.107209-ref44">44</xref>]. Demonstration of a positive contrast requires the design of a special spectral-spatial pulse [<xref ref-type="bibr" rid="scirp.107209-ref58">58</xref>]. The investigative precision of the method employing an ORI scheme employing narrowband frequency-selective pulses to suppress the signals arising from water and fat is indicated besides a broadband spin-echo segment to image the excited spins in the locale of the suppressed water [<xref ref-type="bibr" rid="scirp.107209-ref59">59</xref>].</p><p>Enhancing the contrast of images of the engrafted stem cell is critical for the improvement of wound healing [<xref ref-type="bibr" rid="scirp.107209-ref60">60</xref>]. Thus, non-invasive MR visualization techniques for stem cellsin vivo like the one demonstrated here has the ability to significantly enhance our understanding underlying mechanisms that would lead to efficacious engraftment consequences [<xref ref-type="bibr" rid="scirp.107209-ref61">61</xref>]. Formerly various tissues which were of interest were made to be transplanted with iron labeled cells were imaged with the help if MRI up to weeks [<xref ref-type="bibr" rid="scirp.107209-ref1">1</xref>]. Here, we performed the experiment with two methods, an ORI and an ORI-T<sub>2ρ</sub> method [<xref ref-type="bibr" rid="scirp.107209-ref53">53</xref>]. The ORI-T<sub>2ρ</sub> scheme offers some advantages over the ORI scheme which includes the adjustment of the B<sub>1</sub> field in addition to the mixing time of the spinlock. This might permit a refinement of the contrast levels to specific concentration ranges [<xref ref-type="bibr" rid="scirp.107209-ref53">53</xref>]. Off-resonance MRI approaches produce positive-contrast where, a spectrally selective RF pulse is employed for exciting the off-resonance water signals [<xref ref-type="bibr" rid="scirp.107209-ref40">40</xref>] at the frequency shift induced by the iron particles and refocused such that elimination of the on-resonance background signal takes place at large. The ORI-T<sub>2ρ</sub> method proved to have slightly higher sensitivity. It has potential in the sense that it future work may be benefited from this work. This is the first demonstration where ORI-T<sub>2ρ</sub> method was used to tract SCs in the burn wounds and showed that SCs moved to populate and heal the burn wound (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The beauty of our research is that we have the ability to follow the cellsin vivo. Theoretically after every division the amount of iron decreases in cells so the MRI Signal to noise will decrease. It is of major importance that the cell labeling employed FDA (US Food and Drug Administration) approved reagent will allow this procedure to be performed in human subjects in the near future.</p></sec><sec id="s5"><title>5. Conclusion</title><p>In conclusion, we have demonstrated the feasibility of employing positive-contrast method which combines off-resonance positive-contrast imaging with T<sub>2ρ</sub> relaxation to image labeled stem cellsin vivo, in a clinically relevant burn mouse model. This possibly will prove to be of greater efficacy than the ORI method. The outcomes might have undeviating implications for assessment and longitudinal tracking of labeled stem cells during wound healing. We suggest that our approach can be used in clinical trials in molecular and regenerative medicine.</p></sec><sec id="s6"><title>Acknowledgements</title><p>We would like to thank Shriners Hospital for Children for the funding support provided through Shriners grants to AAT.</p></sec><sec id="s7"><title>Competing Interests</title><p>The authors declare that they have no competing interests.</p></sec><sec id="s8"><title>Funding</title><p>Support was provided by Shriners grant to AAT.</p></sec><sec id="s9"><title>Availability of Data and Materials</title><p>All data used and/or analysed during the present study are available from the corresponding author on reasonable request.</p></sec><sec id="s10"><title>Ethics Approval and Consent to Participate</title><p>This study was carried out in strict accordance with the recommendations of the Guide for the Care and Use of Laboratory Animals of the National Institutes of Health. The protocol was approved by the Committee on the Ethics of Animal Experiments at Massachusetts General Hospital (Permit Number: 2006N000093/2). All procedures were performed under sodium pentobarbital anesthesia, and every effort was made to minimize suffering.</p></sec><sec id="s11"><title>Patient Consent for Publication</title><p>Not Applicable.</p></sec><sec id="s12"><title>Cite this paper</title><p>Qadri, Z., Righi, V., Li, S.S. and Tzika, A.A. (2021) Tracking of Labelled Stem Cells Using Molecular MR Imaging in a Mouse Burn Model in Vivo as an Approach to Regenerative Medicine. Advances in Molecular Imaging, 11, 1-15. https://doi.org/10.4236/ami.2021.111001</p></sec></body><back><ref-list><title>References</title><ref id="scirp.107209-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Castaneda, R.T., Khurana, A., Khan, R. and Daldrup-Link, H.E. (2011) Labeling Stem Cells with Ferumoxytol, an FDA-Approved Iron Oxide Nanoparticle. Journal of Visualized Experiments, 57, e3482. https://doi.org/10.3791/3482</mixed-citation></ref><ref id="scirp.107209-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Nejadnik, H., Castillo, R. and Daldrup-Link, H.E. (2013) Magnetic Resonance Imaging and Tracking of Stem Cells. Methods in Molecular Biology, 1052, 167-176.  
https://doi.org/10.1007/7651_2013_16</mixed-citation></ref><ref id="scirp.107209-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Kuhlpeter, R., Dahnke, H., Matuszewski, L., Persigehl, T., von Wallbrunn, A., Allkemper, T., Heindel. W.L., Schaeffter, T. and Bremer, C. (2007) R2 and R2* Mapping for Sensing Cell-Bound Superparamagnetic Nanoparticles: In Vitro and Murine in Vivo Testing. Radiology, 245, 449-457.  
https://doi.org/10.1148/radiol.2451061345</mixed-citation></ref><ref id="scirp.107209-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Balchandani, P., Yamada, M., Pauly, J., Yang, P. and Spielman, D. (2009) Self-Refocused Spatial-Spectral Pulse for Positive Contrast Imaging of Cells Labeled with SPIO Nanoparticles. Magnetic Resonance in Medicine, 62, 183-192.  
https://doi.org/10.1002/mrm.21973</mixed-citation></ref><ref id="scirp.107209-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Hedlund, A., Ahren, M., Gustafsson, H., Abrikossova, N., Warntjes, M., Jonsson, J.I., Uvdal, K. and Engstrom, M. (2011) Gd(2)O(3) Nanoparticles in Hematopoietic Cells for MRI Contrast Enhancement. International Journal of Nanomedicine, 6, 3233-3240. https://doi.org/10.2147/IJN.S23940</mixed-citation></ref><ref id="scirp.107209-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Kedziorek, D.A. and Kraitchman, D.L. (2010) Superparamagnetic Iron Oxide Labeling of Stem Cells for MRI Tracking and Delivery in Cardiovascular Disease. Methods in Molecular Biology, 660, 171-183.  
https://doi.org/10.1007/978-1-60761-705-1_11</mixed-citation></ref><ref id="scirp.107209-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Hamrahi, V.F., Goverman, J., Jung, W., Wu, J.C., Fischman, A.J., Tompkins, R.G., Yu, Y.Y., Fagan, S.P. and Carter, E.A. (2012) In Vivo Molecular Imaging of Murine Embryonic Stem Cells Delivered to a Burn Wound Surface via Integra(R) Scaffolding. Journal of Burn Care &amp; Research, 33, e49-e54.  
https://doi.org/10.1097/BCR.0b013e3182331d1c</mixed-citation></ref><ref id="scirp.107209-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Frahm, J., Haase, A. and Matthaei, D. (1986) Rapid NMR Imaging of Dynamic Processes Using the FLASH Technique. Magnetic Resonance in Medicine, 3, 321-327. https://doi.org/10.1002/mrm.1910030217</mixed-citation></ref><ref id="scirp.107209-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Andronesi, O.C., Mintzopoulos, D., Righi, V., Psychogios, N., Kesarwani, M., He, J., Yasuhara, S., Dai, G., Rahme, L.G. and Tzika, A.A. (2010) Combined Off-Resonance Imaging and T2 Relaxation in the Rotating Frame for Positive Contrast MR Imaging of Infection in a Murine Burn Model. Magnetic Resonance Imaging, 32, 1172-1183. https://doi.org/10.1002/jmri.22349</mixed-citation></ref><ref id="scirp.107209-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Hennig, J., Nauerth, A. and Friedburg, H. (1986) RARE Imaging: A Fast Imaging Method for Clinical MR. Magnetic Resonance in Medicine, 3, 823-833.  
https://doi.org/10.1002/mrm.1910030602</mixed-citation></ref><ref id="scirp.107209-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Rad, A.M., Janic, B., Iskander, A., Soltanian-Zadeh, H. and Arbab, A.S. (2007) Measurement of Quantity of Iron in Magnetically Labeled Cells: Comparison among Different UV/VIS Spectrometric Methods. Biotechniques, 43, 627-628, 630, 632 passim. https://doi.org/10.2144/000112599</mixed-citation></ref><ref id="scirp.107209-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Padfield, K.E., Astrakas, L.G., Zhang, Q., Gopalan, S., Dai, G., Mindrinos, M.N., Tompkins, R.G., Rahme, L.G. and Tzika, A.A. (2005) Burn Injury Causes Mitochondrial Dysfunction in Skeletal Muscle. Proceedings of the National Academy of Sciences of the United States of America, 102, 5368-5373.  
https://doi.org/10.1073/pnas.0501211102</mixed-citation></ref><ref id="scirp.107209-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Carter, E., Hamrahi, V., Paul, K., Jung, W., Barrow, S., Bonab, A., Tompkins, R. and Fischman, A. (2011) Bone Marrow Cells in Burn Injury Wound Healing. Journal of Nuclear Medicine, 52, 1554.</mixed-citation></ref><ref id="scirp.107209-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Bakker, C.J., Seppenwoolde, J.H. and Vincken, K.L. (2006) Dephased MRI. Magnetic Resonance in Medicine, 55, 92-97. https://doi.org/10.1002/mrm.20733</mixed-citation></ref><ref id="scirp.107209-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Seppenwoolde, J.H., Viergever, M.A. and Bakker, C.J. (2003) Passive Tracking Exploiting Local Signal Conservation: The White Marker Phenomenon. Magnetic Resonance in Medicine, 50, 784-790. https://doi.org/10.1002/mrm.10574</mixed-citation></ref><ref id="scirp.107209-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Walczak, P., Kedziorek, D.A., Gilad, A.A., Lin, S. and Bulte, J.W. (2005) Instant MR Labeling of Stem Cells Using Magnetoelectroporation. Magnetic Resonance in Medicine, 54, 769-774. https://doi.org/10.1002/mrm.20701</mixed-citation></ref><ref id="scirp.107209-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Rad, A.M., Iskander, A.S., Janic, B., Knight, R.A., Arbab, A.S. and Soltanian-Zadeh, H. (2009) AC133+ Progenitor Cells as Gene Delivery Vehicle and Cellular Probe in Subcutaneous Tumor Models: A Preliminary Study. BMC Biotechnology, 9, 28.  
https://doi.org/10.1186/1472-6750-9-28</mixed-citation></ref><ref id="scirp.107209-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Farrar, C.T., Dai, G., Novikov, M., Rosenzweig, A., Weissleder, R., Rosen, B.R. and Sosnovik, D.E. (2008) Impact of Field Strength and Iron Oxide Nanoparticle Concentration on the Linearity and Diagnostic Accuracy of Off-Resonance Imaging. NMR in Biomedicine, 21, 453-463. https://doi.org/10.1002/nbm.1209</mixed-citation></ref><ref id="scirp.107209-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Solomon, I. (1959) Rotary Spin Echoes. Physical Review Letters, 2, 301-302.  
https://doi.org/10.1103/PhysRevLett.2.301</mixed-citation></ref><ref id="scirp.107209-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Torrey, H.C. (1949) Transient Nutations in Nuclear Magnetic Resonance. Physical Review, 76, 1059-1068. https://doi.org/10.1103/PhysRev.76.1059</mixed-citation></ref><ref id="scirp.107209-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Hao, R., Xing, R., Xu, Z., Hou, Y., Gao, S. and Sun, S. (2010) Synthesis, Functionalization, and Biomedical Applications of Multifunctional Magnetic Nanoparticles. Advanced Materials, 22, 2729-2742. https://doi.org/10.1002/adma.201000260</mixed-citation></ref><ref id="scirp.107209-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Cunningham, C.H., Arai, T., Yang, P.C., McConnell, M.V., Pauly, J.M. and Conolly, S.M. (2005) Positive Contrast Magnetic Resonance Imaging of Cells Labeled with Magnetic Nanoparticles. Magnetic Resonance in Medicine, 53, 999-1005.  
https://doi.org/10.1002/mrm.20477</mixed-citation></ref><ref id="scirp.107209-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Redfield, A.G. (1969) Nuclear Spin Thermodynamics in the Rotating Frame. Science, 164, 1015-1023. https://doi.org/10.1126/science.164.3883.1015</mixed-citation></ref><ref id="scirp.107209-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Martirosian, P., Rommel, E., Schick, F. and Deimling, M. (2008) Control of Susceptibility-Related Image Contrast by Spin-Lock Techniques. Magnetic Resonance Imaging, 26, 1381-1387. https://doi.org/10.1016/j.mri.2008.04.013</mixed-citation></ref><ref id="scirp.107209-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Geraldes, C.F. and Laurent, S. (2009) Classification and Basic Properties of Contrast Agents for Magnetic Resonance Imaging. Contrast Media &amp; Molecular Imaging, 4, 1-23. https://doi.org/10.1002/cmmi.265</mixed-citation></ref><ref id="scirp.107209-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Neubauer, A.M., Caruthers, S.D., Hockett, F.D., Cyrus, T., Robertson, J.D., Allen, J.S., Williams, T.D., Fuhrhop, R.W., Lanza, G.M. and Wickline, S.A. (2007) Fluorine Cardiovascular Magnetic Resonance Angiography in Vivo at 1.5 T with Perfluorocarbon Nanoparticle Contrast Agents. Journal of Cardiovascular Magnetic Resonance, 9, 565-573. https://doi.org/10.1080/10976640600945481</mixed-citation></ref><ref id="scirp.107209-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Partlow, K.C., Chen, J., Brant, J.A., Neubauer, A.M., Meyerrose, T.E., Creer, M.H., Nolta, J.A., Caruthers, S.D., Lanza, G.M. and Wickline, S.A. (2007) 19F Magnetic Resonance Imaging for Stem/Progenitor Cell Tracking with Multiple Unique Perfluorocarbon Nanobeacons. The FASEB Journal, 21, 1647-1654.  
https://doi.org/10.1096/fj.06-6505com</mixed-citation></ref><ref id="scirp.107209-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Ruiz-Cabello, J., Walczak, P., Kedziorek, D.A., Chacko, V.P., Schmieder, A.H., Wickline, S.A., Lanza, G.M. and Bulte, J.W. (2008) In Vivo “Hot Spot” MR Imaging of Neural Stem Cells Using Fluorinated Nanoparticles. Magnetic Resonance in Medicine, 60, 1506-1511. https://doi.org/10.1002/mrm.21783</mixed-citation></ref><ref id="scirp.107209-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Waters, E.A., Chen, J., Allen, J.S., Zhang, H., Lanza, G.M. and Wickline, S.A. (2008) Detection and Quantification of Angiogenesis in Experimental Valve Disease with Integrin-Targeted Nanoparticles and 19-Fluorine MRI/MRS. Journal of Cardiovascular Magnetic Resonance, 10, 43. https://doi.org/10.1186/1532-429X-10-43</mixed-citation></ref><ref id="scirp.107209-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Waters, E.A., Chen, J., Yang, X., Zhang, H., Neumann, R., Santeford, A., Arbeit, J., Lanza, G.M. and Wickline, S.A. (2008) Detection of Targeted Perfluorocarbon Nanoparticle Binding Using 19F Diffusion Weighted MR Spectroscopy. Magnetic Resonance in Medicine, 60, 1232-1236. https://doi.org/10.1002/mrm.21794</mixed-citation></ref><ref id="scirp.107209-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Janjic, J.M., Srinivas, M., Kadayakkara, D.K. and Ahrens, E.T. (2008) Self-Delivering Nanoemulsions for Dual Fluorine-19 MRI and Fluorescence Detection. Journal of the American Chemical Society, 130, 2832-2841. https://doi.org/10.1021/ja077388j</mixed-citation></ref><ref id="scirp.107209-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Srinivas, M., Morel, P.A., Ernst, L.A., Laidlaw, D.H. and Ahrens, E.T. (2007) Fluorine-19 MRI for Visualization and Quantification of Cell Migration in a Diabetes Model. Magnetic Resonance in Medicine, 58, 725-734.  
https://doi.org/10.1002/mrm.21352</mixed-citation></ref><ref id="scirp.107209-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Bjornerud, A. and Johansson, L. (2004) The Utility of Superparamagnetic Contrast Agents in MRI: Theoretical Consideration and Applications in the Cardiovascular System. NMR in Biomedicine, 17, 465-477. https://doi.org/10.1002/nbm.904</mixed-citation></ref><ref id="scirp.107209-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Na, H.B., Lee, J.H., An, K., Park, Y.I., Park, M., Lee, I.S., Nam, D.H., Kim, S.T., Kim, S.H., Kim, S.W., et al. (2007) Development of a T1 Contrast Agent for Magnetic Resonance Imaging Using MnO Nanoparticles. Angewandte Chemie International Edition, 46, 5397-5401. https://doi.org/10.1002/anie.200604775</mixed-citation></ref><ref id="scirp.107209-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Rocklage, S.M., Cacheris, W.P., Quay, S.C., Hahn, F.E. and Raymond, K.N. (1989) Synthesis and Characterization of a Paramagnetic Chelate for Magnetic Resonance Imaging Enhancement. Inorganic Chemistry, 28, 477-485.  
https://doi.org/10.1021/ic00302a019</mixed-citation></ref><ref id="scirp.107209-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Caravan, P., Ellison, J.J., McMurry, T.J. and Lauffer, R.B. (1999) Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications. Chemical Reviews, 99, 2293-2352. https://doi.org/10.1021/cr980440x</mixed-citation></ref><ref id="scirp.107209-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Dale, B.M., Brown, M.A. and Semelka, R.C. (2015) MRI Basic Principles and Applications. Wiley Blackwell/John Wiley &amp; Sons, Hoboken.  
https://doi.org/10.1002/9781119013068</mixed-citation></ref><ref id="scirp.107209-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Britton, M.M. (2010) Magnetic Resonance Imaging of Chemistry. Chemical Society Reviews, 39, 4036-4043. https://doi.org/10.1039/b908397a</mixed-citation></ref><ref id="scirp.107209-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Winter, P.M., Caruthers, S.D., Lanza, G.M. and Wickline, S.A. (2010) Quantitative Cardiovascular Magnetic Resonance for Molecular Imaging. Journal of Cardiovascular Magnetic Resonance, 12, 62. https://doi.org/10.1186/1532-429X-12-62</mixed-citation></ref><ref id="scirp.107209-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Vande Velde, G., Baekelandt, V., Dresselaers, T. and Himmelreich, U. (2009) Magnetic Resonance Imaging and Spectroscopy Methods for Molecular Imaging. Quarterly Journal of Nuclear Medicine and Molecular Imaging, 53, 565-585.</mixed-citation></ref><ref id="scirp.107209-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Louie, A. (2010) Multimodality Imaging Probes: Design and Challenges. Chemical Reviews, 110, 3146-3195. https://doi.org/10.1021/cr9003538</mixed-citation></ref><ref id="scirp.107209-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">Srivastava, A.K. and Bulte, J.W. (2014) Seeing Stem Cells at Work in Vivo. Stem Cell Reports, 10, 127-144. https://doi.org/10.1007/s12015-013-9468-x</mixed-citation></ref><ref id="scirp.107209-ref43"><label>43</label><mixed-citation publication-type="other" xlink:type="simple">Nejadnik, H., Henning, T.D., Castaneda, R.T., Boddington, S., Taubert, S., Jha, P., Tavri, S., Golovko, D., Ackerman, L., Meier, R., et al. (2012) Somatic Differentiation and MR Imaging of Magnetically Labeled Human Embryonic Stem Cells. Cell Transplantation, 21, 2555-2567. https://doi.org/10.3727/096368912X653156</mixed-citation></ref><ref id="scirp.107209-ref44"><label>44</label><mixed-citation publication-type="other" xlink:type="simple">Zanzonico, P., Koehne, G., Gallardo, H.F., Doubrovin, M., Doubrovina, E., Finn, R., Blasberg, R.G., Riviere, I., O’Reilly, R.J., Sadelain, M., et al. (2006) [131I]FIAU Labeling of Genetically Transduced, Tumor-Reactive Lymphocytes: Cell-Level Dosimetry and Dose-Dependent toxicity. European Journal of Nuclear Medicine and Molecular Imaging, 33, 988-997. https://doi.org/10.1007/s00259-005-0057-3</mixed-citation></ref><ref id="scirp.107209-ref45"><label>45</label><mixed-citation publication-type="other" xlink:type="simple">Adonai, N., Adonai, N., Nguyen, K.N., Walsh, J., Iyer, M., Toyokuni, T., Phelps, M.E., McCarthy, T., McCarthy, D.W. and Gambhir, S.S. (2002) Ex Vivo Cell Labeling with 64Cu-pyruvaldehyde-bis(N4-methylthiosemicarbazone) for Imaging Cell Trafficking in Mice with Positron-Emission Tomography. Proceedings of the National Academy of Sciences of the United States of America, 99, 3030-3035.  
https://doi.org/10.1073/pnas.052709599</mixed-citation></ref><ref id="scirp.107209-ref46"><label>46</label><mixed-citation publication-type="other" xlink:type="simple">Massoud, T.F. and Gambhir, S.S. (2003) Molecular Imaging in Living Subjects: Seeing Fundamental Biological Processes in a New Light. Genes &amp; Development, 17, 545-580. https://doi.org/10.1101/gad.1047403</mixed-citation></ref><ref id="scirp.107209-ref47"><label>47</label><mixed-citation publication-type="other" xlink:type="simple">Lei, Y., Tang, H., Yao, L., Yu, R., Feng, M. and Zou, B. (2008) Applications of Mesenchymal Stem Cells Labeled with Tat Peptide Conjugated Quantum Dots to Cell Tracking in Mouse Body. Bioconjugate Chemistry, 19, 421-427.  
https://doi.org/10.1021/bc0700685</mixed-citation></ref><ref id="scirp.107209-ref48"><label>48</label><mixed-citation publication-type="other" xlink:type="simple">Voura, E.B., Jaiswal, J.K., Mattoussi, H. and Simon, S.M. (2004) Tracking Metastatic tumor Cell Extravasation with Quantum Dot Nanocrystals and Fluorescence Emission-Scanning Microscopy. Nature Medicine, 10, 993-998.  
https://doi.org/10.1038/nm1096</mixed-citation></ref><ref id="scirp.107209-ref49"><label>49</label><mixed-citation publication-type="other" xlink:type="simple">Song, X., Chan, K.W. and McMahon, M.T. (2011) Screening of CEST MR Contrast Agents. Methods in Molecular Biology, 771, 171-187.  
https://doi.org/10.1007/978-1-61779-219-9_9</mixed-citation></ref><ref id="scirp.107209-ref50"><label>50</label><mixed-citation publication-type="other" xlink:type="simple">Liu, P., Deng, Z., Han, S., Liu, T., Wen, N., Lu, W., Geng, X., Huang, S. and Jin, Y. (2008) Tissue-Engineered Skin Containing Mesenchymal Stem Cells Improves Burn Wounds. Artificial Organs, 32, 925-931.  
https://doi.org/10.1111/j.1525-1594.2008.00654.x</mixed-citation></ref><ref id="scirp.107209-ref51"><label>51</label><mixed-citation publication-type="other" xlink:type="simple">Bey, E., Prat, M., Duhamel, P., Benderitter, M., Brachet, M., Trompier, F., Battaglini, P., Ernou, I., Boutin, L., Gourven, M., et al. (2010) Emerging Therapy for Improving Wound Repair of Severe Radiation Burns Using Local Bone Marrow-Derived Stem Cell Administrations. Wound Repair and Regeneration, 18, 50-58. https://doi.org/10.1111/j.1524-475X.2009.00562.x</mixed-citation></ref><ref id="scirp.107209-ref52"><label>52</label><mixed-citation publication-type="other" xlink:type="simple">Lataillade, J.J., Doucet, C., Bey, E., Carsin, H., Huet, C., Clairand, I., Bottollier-Depois, J.F., Chapel, A., Ernou, I., Gourven, M., et al. (2007) New Approach to Radiation Burn Treatment by Dosimetry-Guided Surgery Combined with Autologous Mesenchymal Stem Cell Therapy. Regenerative Medicine, 2, 785-794.  
https://doi.org/10.2217/17460751.2.5.785</mixed-citation></ref><ref id="scirp.107209-ref53"><label>53</label><mixed-citation publication-type="other" xlink:type="simple">Rasulov, M.F., Vasilenko, V.T., Zaidenov, V.A. and Onishchenko, N.A. (2006) Cell Transplantation Inhibits Inflammatory Reaction and Stimulates Repair Processes in Burn Wound. Bulletin of Experimental Biology and Medicine, 142, 112-115.  
https://doi.org/10.1007/s10517-006-0306-x</mixed-citation></ref><ref id="scirp.107209-ref54"><label>54</label><mixed-citation publication-type="other" xlink:type="simple">Rasulov, M.F., Vasilchenkov, A.V., Onishchenko, N.A., Krasheninnikov, M.E., Kravchenko, V.I., Gorshenin, T.L., Pidtsan, R.E. and Potapov, I.V. (2005) First Experience of the Use Bone Marrow Mesenchymal Stem Cells for the Treatment of a Patient with Deep Skin Burns. Bulletin of Experimental Biology and Medicine, 139, 141-144. https://doi.org/10.1007/s10517-005-0232-3</mixed-citation></ref><ref id="scirp.107209-ref55"><label>55</label><mixed-citation publication-type="other" xlink:type="simple">Shumakov, V.I., Onishchenko, N.A., Rasulov, M.F., Krasheninnikov, M.E. and Zaidenov, V.A. (2003) Mesenchymal Bone Marrow Stem Cells More Effectively Stimulate Regeneration of Deep Burn Wounds than Embryonic Fibroblasts. Bulletin of Experimental Biology and Medicine, 136, 192-195.  
https://doi.org/10.1023/A:1026387411627</mixed-citation></ref><ref id="scirp.107209-ref56"><label>56</label><mixed-citation publication-type="other" xlink:type="simple">Hu, M., Ludlow, D., Alexander, J.S., McLarty, J. and Lian, T. (2014) Improved Wound Healing of Postischemic Cutaneous Flaps with the Use of Bone Marrow-Derived Stem Cells. Laryngoscope, 124, 642-648.  
https://doi.org/10.1002/lary.24293</mixed-citation></ref><ref id="scirp.107209-ref57"><label>57</label><mixed-citation publication-type="other" xlink:type="simple">Nakamura, Y., Ishikawa, H., Kawai, K., Tabata, Y. and Suzuki, S. (2013) Enhanced Wound Healing by Topical Administration of Mesenchymal Stem Cells Transfected with Stromal Cell-Derived Factor-1. Biomaterials, 34, 9393-9400.  
https://doi.org/10.1016/j.biomaterials.2013.08.053</mixed-citation></ref><ref id="scirp.107209-ref58"><label>58</label><mixed-citation publication-type="other" xlink:type="simple">Jayaraman, P., Nathan, P., Vasanthan, P., Musa, S. and Govindasamy, V. (2013) Stem Cells Conditioned Medium: A New Approach to Skin Wound Healing Management. Cell Biology International, 37, 1122-1128.  
https://doi.org/10.1002/cbin.10138</mixed-citation></ref><ref id="scirp.107209-ref59"><label>59</label><mixed-citation publication-type="other" xlink:type="simple">Ghieh, F., Jurjus, R., Ibrahim, A., Geagea, A.G., Daouk, H., El Baba, B., Chams, S., Matar, M., Zein, W. and Jurjus, A. (2015) The Use of Stem Cells in Burn Wound Healing: A Review. BioMed Research International, 2015, Article ID: 684084. https://doi.org/10.1155/2015/684084</mixed-citation></ref><ref id="scirp.107209-ref60"><label>60</label><mixed-citation publication-type="other" xlink:type="simple">Maltsev, V.A., Rohwedel, J., Hescheler, J. and Wobus, A.M. (1993) Embryonic Stem Cells Differentiate in Vitro into Cardiomyocytes Representing Sinusnodal, Atrial and Ventricular Cell Types. Mechanisms of Development, 44, 41-50.  
https://doi.org/10.1016/0925-4773(93)90015-P</mixed-citation></ref><ref id="scirp.107209-ref61"><label>61</label><mixed-citation publication-type="other" xlink:type="simple">Kozlik, M. and Wojcicki, P. (2014) The Use of Stem Cells in Plastic and Reconstructive Surgery. Advances in Clinical and Experimental Medicine, 23, 1011-1017.  
https://doi.org/10.17219/acem/37360</mixed-citation></ref></ref-list></back></article>