<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">EPE</journal-id><journal-title-group><journal-title>Energy and Power Engineering</journal-title></journal-title-group><issn pub-type="epub">1949-243X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/epe.2021.132005</article-id><article-id pub-id-type="publisher-id">EPE-107009</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Influence of Capacitive Effects on Transformer Windings
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mathurin</surname><given-names>Gogom</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Rodolphe</surname><given-names>Gomba</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Desire</surname><given-names>Lilonga-Boyenga</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Polytechnical Superior National School, Marien Ngouabi University, Brazzaville, Congo</addr-line></aff><pub-date pub-type="epub"><day>02</day><month>02</month><year>2021</year></pub-date><volume>13</volume><issue>02</issue><fpage>67</fpage><lpage>80</lpage><history><date date-type="received"><day>4,</day>	<month>June</month>	<year>2020</year></date><date date-type="rev-recd"><day>31,</day>	<month>January</month>	<year>2021</year>	</date><date date-type="accepted"><day>3,</day>	<month>February</month>	<year>2021</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  For years, capacitive effects have been the subject of research [1] and [2]. The capacitive effects are discrete capacitors that appear between active conductors of power lines and between them with the ground plane, generating capacitive reactive power to the network [1] and [2]. Indeed, it must be noted that these effects affect the windings of the transformer when the coupling is in star or triangle. This study is conducted to show that capacitive effects affect transformer windings differently when coupling is in stars or triangles. The results obtained are interesting and can be exploited in electrical transmission networks to ensure a long lifespan of transformers.
 
</p></abstract><kwd-group><kwd>Capacitive Effects</kwd><kwd> Discrete Capacitors</kwd><kwd> Geometry of Conductors</kwd><kwd> Transformers Windings</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The transport of electrical energy between production and consumption centres, often characterized by long distances, poses many problems, among other things, joule losses and voltage drops [<xref ref-type="bibr" rid="scirp.107009-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref7">7</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref8">8</xref>]. To this end, several works have been carried out, including the optimization of joule losses and voltage drops through traditional or advanced compensation of reactive power [<xref ref-type="bibr" rid="scirp.107009-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref6">6</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref7">7</xref>]. However, work on the impact of capacitive effects is still very limited, requiring special attention.</p><p>Indeed, the reactive energy generated by discrete capacitors that are created between the different active conductors on the one hand, and between each active conductor with the plane of the ground on the other hand, varies according to the configuration (geometry) of the line. This generated reactive energy is distributed in half on each of the two ends of the line or cable [<xref ref-type="bibr" rid="scirp.107009-ref8">8</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref10">10</xref>]. When not consumed, this reactive energy generated becomes one of the causes of unwanted surges and therefore instability of the voltage of the network. These capacitive effects are very harmful when operating empty or low-load transportation system [<xref ref-type="bibr" rid="scirp.107009-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref12">12</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref13">13</xref>]. These capacitive effects have a different impact on the transformer windings connected to the power transmission lines. This difference is due to the way the coils are paired.</p><p>The formation of these discrete capacitors reflects the capacitive effects on electrical lines and cables. The reactive power absorbed by the inductions of the lines or debited by the capacitors thus formed must obey the requirements of the networks, including the stability and reliability of the transport networks.</p><p>The interest of this work is to show how discrete capacitors affect transformers’ coils differently because of their coupling. Therefore, special attention must be paid to the selection of the cutting of the windings of transformers operated in the transmission networks of electrical energy.</p></sec><sec id="s2"><title>2. Theoretical Study</title><sec id="s2_1"><title>2.1. Capacitors Illustrations</title><p>A high voltage power line generates reactive energy because of the capacitors that form between the different conductors on the one hand, and between each conductor and the ground plane on the other hand, as illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref> [<xref ref-type="bibr" rid="scirp.107009-ref3">3</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref4">4</xref>].</p><p>Indeed, the capacitor which forms between two conductors (1) and (2) for example, generates reactive power Q<sub>12</sub> to the network. Between the different line conductors, we have capacitors C<sub>12</sub>, C<sub>23</sub> and C<sub>13</sub>, and between each line conductor and the ground plane the capacitors C<sub>10</sub>, C<sub>20</sub> and C<sub>30</sub>.</p></sec><sec id="s2_2"><title>2.2. Reactive Power Generated</title><p>The example of the plug circuit makes us understand that the capacitor sends its energy on the impedance which is in parallel with it; this allows us to deduce that among the various capacitors formed between the lines conductors, some generate undesirable reactive energy on the transformers windings at the level of the departure and arrival stations when the line is operating at empty or at low load.</p><p>The power generated by the capacitor formed between the two conductors (i) and (j) as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>, is found in half on each end of the section, that means Q<sub>ij</sub>/2 on each end [<xref ref-type="bibr" rid="scirp.107009-ref3">3</xref>] and [<xref ref-type="bibr" rid="scirp.107009-ref4">4</xref>].</p><sec id="s2_2_1"><title>2.2.1. Triangle Transformer Coupling</title><p>1) Reactive powers generated</p><p>It is established that the various capacitors formed between the line conductors appear as reactive energy sources as illustrated in <xref ref-type="fig" rid="fig3">Figure 3</xref>. They respectively supply impedances in parallel, in particular the transformer windings.</p><p>For a capacitor created between the active line conductor and the ground</p><p>plane, the reactive power generated by these different capacitors is located between the phases and the ground plane. This reactive power is that which can be consumed by the equipment which are in parallel with them located at the entrance to the transformer station if these exist. The expression of this reactive power is given by the relation (1) below [<xref ref-type="bibr" rid="scirp.107009-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref2">2</xref>]:</p><p>Q i 0 = 3 C i 0 ω V i 0 2 (1)</p><p>where V i 0 is the simple voltage of module V i 0 = U 12 3 = U 13 3 = U 23 3 et i = 1, 2 and 3;</p><p>For the capacitors formed between the guard cables and the ground plane, it can be said that all the energy is earthed, because the two plates constituting this capacitor are earthed; regarding the capacitor created between an active conductor and the guard wire, we find ourselves in the case of a capacitor armature which is connected to earth. Here, we join the previous case where the power generated by the capacitor is sent to earth.</p><p>In the case of the capacitor formed between two guard cables, the two armatures of the capacitor thus formed are connected to the ground through pylons. The reactive energy generated is well flowed to the earth;</p><p>Regarding the capacitors formed between active conductors, the reactive powers generated by the three capacitors created between the two active conductors of the line are such that:</p><p>Q 12 = C 12 ω ( U 12 ) 2 , Q 13 = C 13 ω ( U 13 ) 2 et Q 23 = C 23 ω ( U 23 ) 2 (2)</p><p>At the start station, this reactive power generated by the capacitors of the line is consumed by the secondary winding of the transformer while at the arrival station; this reactive power is consumed by the primary winding of the transformer at this station. Then we can write [<xref ref-type="bibr" rid="scirp.107009-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref2">2</xref>]:</p><p>Q 12 = U 12 2 L 12 ω then L 12 = U 12 2 Q 12 ω 2 (3)</p><p>Q 13 = U 13 2 L 13 ω then L 13 = U 13 2 Q 13 ω 2 (4)</p><p>Q 23 = U 23 2 L 23 ω then L 23 = U 23 2 Q 23 ω 2 (5)</p><p>2) Equivalent capacities</p><p>For the purposes of modeling a power line in T or in π, the value of the capacity C to be taken into account per phase is the capacity resulting from the transformation of <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>The triangle formed by nodes 1, 2 and 3 can be reduced to the star shape by the triangle-star transformation. The point “n” is at the same potential as the earth, the values of C<sub>1n</sub>, C<sub>2n</sub> and C<sub>3n</sub> are given by [<xref ref-type="bibr" rid="scirp.107009-ref8">8</xref>]: (<xref ref-type="fig" rid="fig5">Figure 5</xref>)</p><p>C 1 n = C 12 + C 13 + C 12 C 13 C 23 (6)</p><p>C 2 n = C 12 + C 23 + C 12 C 23 C 13 (7)</p><p>C 3 n = C 13 + C 23 + C 13 C 23 C 12 (8)</p><p>We arrive at the final equivalent diagram of <xref ref-type="fig" rid="fig6">Figure 6</xref> of which C &#233; q 1 , C &#233; q 2 and C &#233; q 3 are given by the expressions below:</p><p>C &#233; q 1 = C 1 n + C 10 (9)</p><p>C &#233; q 2 = C 2 n + C 20 (10)</p><p>C &#233; q 3 = C 3 n + C 30 (11)</p></sec><sec id="s2_2_2"><title>2.2.2. Star Transformer Coupling</title><p>1) Reactive power generated</p><p>As in the previous case, the different capacitors formed act in the same way. They feed the impedances which are parallel to them (<xref ref-type="fig" rid="fig7">Figure 7</xref>).</p><p>For a capacitor created between the line active conductor and the ground, the reactive power generated by these different capacitors is located between the phases and the ground. This reactive power is that consumed by half the transformers windings of the upstream and downstream stations of the line. It is given by the relation:</p><p>Q i 0 = 3 C i 0 ω V i 0 2 (12)</p><p>where V i 0 is the simple voltage for which the module is given by V i 0 = U 12 3 = U 13 3 = U 23 3 , i = 1, 2 and 3;</p><p>As for the capacitors formed between the guard cables and the ground, all of the reactive energy is earthed; Regarding the capacitor created between an active conductor and the guard wire, all reactive energy is discharged to the earth; In the case of the capacitor formed between two guard cables, the reactive energy generated is well drained to the earth; As regards the capacitors formed between two active conductors, the reactive powers generated by each capacitor are such that:</p><p>Q 12 = C 12 ω ( U 12 ) 2 , Q 13 = C 13 ω ( U 13 ) 2 , Q 23 = C 23 ω ( U 23 ) 2 (13)</p><p>At the start station, half of this reactive power generated by the capacitors formed between line active conductors is consumed by the two secondary windings of the transformer; and at the arrival station, the other half of this reactive power is consumed by the two primary windings of the transformer at this station. Each winding consumes:</p><p>Q 1 = L 1 ω I 1 2 = V 1 2 L 1 ω (14)</p><p>Q 2 = L 2 ω I 2 2 = V 2 2 L 2 ω (15)</p><p>Q 12 = Q 1 + Q 2 (16)</p><p>We deduce successively:</p><p>Q 12 = V 1 2 L 1 ω + V 2 2 L 2 ω (17)</p><p>Q 13 = V 1 2 L 1 ω + V 3 2 L 3 ω (18)</p><p>Q 23 = V 2 2 L 2 ω + V 3 2 L 3 ω (19)</p><p>2) Equivalent capacities</p><p>For modeling purposes of a power line in T or π, the value of the capacitance C to be taken into account per phase is the capacitance resulting from the transformation of <xref ref-type="fig" rid="fig8">Figure 8</xref> below.</p><p>For modeling purposes of a power line in T or π, the value of the capacitance C to be taken into account per phase is the capacitance resulting from the transformation of <xref ref-type="fig" rid="fig8">Figure 8</xref> below.</p><p>The triangle formed by nodes 1, 2 and 3 can be reduced to a star shape by the triangle-star transformation. The point “n” is at the same potential as the earth, the values of C<sub>1n</sub>, C<sub>2n</sub> and C<sub>3n</sub> are given by: (<xref ref-type="fig" rid="fig9">Figure 9</xref>)</p><p>C 1 n = C 12 + C 13 + C 12 C 13 C 23 (6')</p><p>C 2 n = C 12 + C 23 + C 12 C 23 C 13 (7')</p><p>C 3 n = C 13 + C 23 + C 13 C 23 C 12 (8')</p><p>We arrive at the following final equivalent diagram: (<xref ref-type="fig" rid="fig1">Figure 1</xref>0)</p><p>Under the balanced three-phase regime hypothesis, point n is at the same potential as earth, thus:</p><p>C &#233; q 1 = C 1 n + C 10 (9')</p><p>C &#233; q 2 = C 2 n + C 20 (10')</p><p>C &#233; q 3 = C 3 n + C 30 (11')</p></sec></sec><sec id="s2_3"><title>2.3. Capacitor Capacity</title><p>It is a question of giving the expressions of the capacitors capacities formed between the line active conductors on the one hand, and between line active conductor with the ground plane on the other hand by taking into account the geometry of the lines. The capacity of a capacitor formed between two active conductors is given by [<xref ref-type="bibr" rid="scirp.107009-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref13">13</xref>]:</p><p>C i j = π ε 0 log [ D i j 2 + D i j 2 4 + r 2 r ] (20)</p><p>However, that of a capacitor formed between the active conductor and the ground plane is given by [<xref ref-type="bibr" rid="scirp.107009-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.107009-ref13">13</xref>]:</p><p>C i 0 = 2 π ε 0 log [ h i 0 + h i 0 2 + r 2 r ] (21)</p><p>where:</p><p>D<sub>ij</sub>, the distance between two active conductors; r, conductor radius; ε 0 , absolute permittivity in a vacuum ( ε 0 = 8.854 &#215; 10 − 12 F / m ) and h<sub>i</sub><sub>0</sub>, the distance between the active conductor and the ground plane.</p></sec></sec><sec id="s3"><title>3. Determination of Reactive Capacities and Powers</title><sec id="s3_1"><title>3.1. Reactive Capacities and Powers</title><p>We use formulas (2), (12), (13), (20) and (21) to calculate the capacities and the reactive powers generated C<sub>ij</sub>, C<sub>i</sub><sub>0</sub>, Q<sub>ij</sub> and Q<sub>i</sub><sub>0</sub> as a function of the voltage level and the geometry of the single term line conductors; the distance between two active conductors, the radius of the conductor and the distance between the active conductor on the ground plane. The results obtained are reported in <xref ref-type="table" rid="table1">Table 1</xref> and <xref ref-type="table" rid="table2">Table 2</xref> below.</p><p>We note, from the results recorded in <xref ref-type="table" rid="table1">Table 1</xref>, that the capacities C<sub>ij</sub> and C<sub>i</sub><sub>0</sub> are not the same; they vary according to the geometry of the line conductors. The reactive powers Q<sub>ij</sub> and Q<sub>i</sub><sub>0</sub> generated vary in the same way. It should also be noted that the reactive power generated by the capacitor formed between the active conductor and the ground plane decreases as the height between them increases. Similarly, that generated by the capacitors formed between active conductors decreases when the distance between them increases.</p></sec><sec id="s3_2"><title>3.2. Equivalent Capacities and Reactive powers</title><p>The formulas (6), (7), (8), (9), (10), (11) and (12) enabled us to calculate the equivalent capacities values of the capacitors thus formed for each voltage level. However, formulas (1) and (12) allowed us to calculate the reactive powers generated per phase. The results obtained are presented in <xref ref-type="table" rid="table3">Table 3</xref>.</p><p>For each given voltage level, the equivalent capacities C<sub>eqi</sub>and the reactive powers generated Q<sub>i</sub> differ from one geometry of the line conductors to another. Likewise, the equivalent capacities and the reactive powers generated differ from one phase to another. With regard to the results in <xref ref-type="table" rid="table4">Table 4</xref>, we note that the windings of the transformers consume different reactive powers.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Capacitance values of capacitors formed</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Capacitance</th><th align="center" valign="middle"  colspan="3"  >110 KV</th><th align="center" valign="middle"  colspan="3"  >220 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >C<sub>12</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >9.6136</td><td align="center" valign="middle" >9.6136</td><td align="center" valign="middle" >9.6136</td></tr><tr><td align="center" valign="middle" >C<sub>13</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >9.1405</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >9.616</td><td align="center" valign="middle" >8.7076</td><td align="center" valign="middle" >9.6136</td><td align="center" valign="middle" >9.1382</td></tr><tr><td align="center" valign="middle" >C<sub>23</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >10.144</td><td align="center" valign="middle" >9.6136</td><td align="center" valign="middle" >9.6136</td><td align="center" valign="middle" >9.6136</td></tr><tr><td align="center" valign="middle" >C<sub>10</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >14.876</td><td align="center" valign="middle" >15.251</td><td align="center" valign="middle" >15.251</td><td align="center" valign="middle" >14.799</td></tr><tr><td align="center" valign="middle" >C<sub>20</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >14.647</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >15.251</td><td align="center" valign="middle" >14.501</td><td align="center" valign="middle" >15.251</td></tr><tr><td align="center" valign="middle" >C<sub>30</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >15.198</td><td align="center" valign="middle" >15.251</td><td align="center" valign="middle" >15.251</td><td align="center" valign="middle" >15.251</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Reactive powers values generated</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Reactive powers</th><th align="center" valign="middle"  colspan="3"  >110 KV</th><th align="center" valign="middle"  colspan="3"  >220 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >Q<sub>12</sub> (KVAR/Km)</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >146.104</td><td align="center" valign="middle" >146.104</td><td align="center" valign="middle" >146.104</td></tr><tr><td align="center" valign="middle" >Q<sub>13</sub> (KVAR/Km)</td><td align="center" valign="middle" >34.728</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >36.535</td><td align="center" valign="middle" >132.336</td><td align="center" valign="middle" >146.104</td><td align="center" valign="middle" >138.879</td></tr><tr><td align="center" valign="middle" >Q<sub>23</sub> (KVAR/Km)</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >38.541</td><td align="center" valign="middle" >146.104</td><td align="center" valign="middle" >146.104</td><td align="center" valign="middle" >146.104</td></tr><tr><td align="center" valign="middle" >Q<sub>10</sub> (KVAR/Km)</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >56.522</td><td align="center" valign="middle" >231.777</td><td align="center" valign="middle" >231.777</td><td align="center" valign="middle" >224.923</td></tr><tr><td align="center" valign="middle" >Q<sub>20</sub> (KVAR/Km)</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >55.651</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >231.777</td><td align="center" valign="middle" >220.376</td><td align="center" valign="middle" >231.777</td></tr><tr><td align="center" valign="middle" >Q<sub>30</sub> (KVAR/Km)</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >57.745</td><td align="center" valign="middle" >231.777</td><td align="center" valign="middle" >231.777</td><td align="center" valign="middle" >231.777</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Equivalent capacitance values of the capacitors formed</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Equivalent capacitance</th><th align="center" valign="middle"  colspan="3"  >110 KV</th><th align="center" valign="middle"  colspan="3"  >220 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >C<sub>eq</sub><sub>.1</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >43.6235</td><td align="center" valign="middle" >45.63039</td><td align="center" valign="middle" >44.2529</td><td align="center" valign="middle" >42.2799</td><td align="center" valign="middle" >44.0918</td><td align="center" valign="middle" >41.8289</td></tr><tr><td align="center" valign="middle" >C<sub>eq</sub><sub>.2</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >45.6304</td><td align="center" valign="middle" >45.07924</td><td align="center" valign="middle" >46.1872</td><td align="center" valign="middle" >45.0920</td><td align="center" valign="middle" >43.3416</td><td align="center" valign="middle" >44.5919</td></tr><tr><td align="center" valign="middle" >C<sub>eq</sub><sub>.3</sub> (10<sup>−12</sup> F/m)</td><td align="center" valign="middle" >43.6235</td><td align="center" valign="middle" >45.63039</td><td align="center" valign="middle" >44.5747</td><td align="center" valign="middle" >42.2799</td><td align="center" valign="middle" >44.0918</td><td align="center" valign="middle" >43.1410</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Reactive power values generated per phase</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Reactive power</th><th align="center" valign="middle"  colspan="3"  >110 KV</th><th align="center" valign="middle"  colspan="3"  >220 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >Q<sub>1</sub> (KVAR/Km)</td><td align="center" valign="middle" >165.7431</td><td align="center" valign="middle" >173.3681</td><td align="center" valign="middle" >168.1345</td><td align="center" valign="middle" >672.1592</td><td align="center" valign="middle" >670.0896</td><td align="center" valign="middle" >635.6988</td></tr><tr><td align="center" valign="middle" >Q<sub>2</sub> (KVAR/Km)</td><td align="center" valign="middle" >173.3681</td><td align="center" valign="middle" >171.2741</td><td align="center" valign="middle" >175.4836</td><td align="center" valign="middle" >685.2900</td><td align="center" valign="middle" >658.6884</td><td align="center" valign="middle" >677.6898</td></tr><tr><td align="center" valign="middle" >Q<sub>3</sub> (KVAR/Km)</td><td align="center" valign="middle" >165.7431</td><td align="center" valign="middle" >173.3681</td><td align="center" valign="middle" >169.3571</td><td align="center" valign="middle" >642.5528</td><td align="center" valign="middle" >670.0896</td><td align="center" valign="middle" >655.6396</td></tr></tbody></table></table-wrap></sec><sec id="s3_3"><title>3.3. Application to the Radial Network</title><p>The influence of capacitive effects on the windings of the transformers located upstream and downstream of the lines is examined on the Liouesso-Ouesso network in the Sangha department of the Republic of Congo.</p><sec id="s3_3_1"><title>3.3.1. Network Description</title><p>The Liouesso-Ouesso electrical network is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>1. These characteristics are summarized in <xref ref-type="table" rid="table5">Table 5</xref>.</p></sec><sec id="s3_3_2"><title>3.3.2. Network Modeling</title><p>We possibly choose the basic voltage and power to transcribe the network parameters in pu [<xref ref-type="bibr" rid="scirp.107009-ref9">9</xref>]. So, U<sub>B</sub> = 110 KV; S<sub>B</sub> = 100 MVA and we deduce the basic</p><p>impedance and admittance such as: Z B = U B 2 S B et Y B = S B U B 2 . These parameters are presented in <xref ref-type="table" rid="table6">Table 6</xref> and <xref ref-type="table" rid="table7">Table 7</xref> below:</p><table-wrap-group id="5"><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> (a) Characteristics of the Liouesso-Ouesso network; (b) Continuation of the characteristics of the Liouesso-Ouesso network</title></caption><table-wrap id="5_1"><caption><title> (b)</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="4"  >Alternators</th><th align="center" valign="middle"  colspan="5"  >Transformation post of Liouesso</th></tr></thead><tr><td align="center" valign="middle" >U<sub>n</sub></td><td align="center" valign="middle" >3 &#215; S<sub>n</sub></td><td align="center" valign="middle" >cosφ</td><td align="center" valign="middle" >3 &#215; P<sub>n</sub></td><td align="center" valign="middle" >U<sub>1n</sub></td><td align="center" valign="middle" >U<sub>2</sub><sub>n</sub></td><td align="center" valign="middle" >S<sub>n</sub></td><td align="center" valign="middle" >U<sub>ncc</sub></td><td align="center" valign="middle" >P<sub>ncc</sub></td></tr><tr><td align="center" valign="middle" >kV</td><td align="center" valign="middle" >MVA</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >MW</td><td align="center" valign="middle" >KV</td><td align="center" valign="middle" >KV</td><td align="center" valign="middle" >MVA</td><td align="center" valign="middle" >%</td><td align="center" valign="middle" >KW</td></tr><tr><td align="center" valign="middle" >11</td><td align="center" valign="middle" >23.43</td><td align="center" valign="middle" >0.85</td><td align="center" valign="middle" >19.5</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >110</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >10.5</td><td align="center" valign="middle" >29</td></tr></tbody></table></table-wrap><table-wrap id="5_2"><caption><title></title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="4"  >Ligne 110 kV</th><th align="center" valign="middle"  colspan="5"  >Transformation post of Ouesso</th></tr></thead><tr><td align="center" valign="middle" >L</td><td align="center" valign="middle" >r<sub>0</sub></td><td align="center" valign="middle" >x<sub>0</sub></td><td align="center" valign="middle" >b<sub>0</sub></td><td align="center" valign="middle" >U<sub>1n</sub></td><td align="center" valign="middle" >U<sub>2</sub><sub>n</sub></td><td align="center" valign="middle" >S<sub>n</sub></td><td align="center" valign="middle" >U<sub>ncc</sub></td><td align="center" valign="middle" >P<sub>ncc</sub></td></tr><tr><td align="center" valign="middle" >Km</td><td align="center" valign="middle" >Ω/Km</td><td align="center" valign="middle" >Ω/Km</td><td align="center" valign="middle" >Ω<sup>−1</sup>/Km</td><td align="center" valign="middle" >KV</td><td align="center" valign="middle" >KV</td><td align="center" valign="middle" >MVA</td><td align="center" valign="middle" >%</td><td align="center" valign="middle" >KW</td></tr><tr><td align="center" valign="middle" >120</td><td align="center" valign="middle" >0.17</td><td align="center" valign="middle" >0.39</td><td align="center" valign="middle" >2.95.10<sup>−6</sup></td><td align="center" valign="middle" >110</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >10.5</td><td align="center" valign="middle" >60</td></tr></tbody></table></table-wrap></table-wrap-group><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> Longitudinal and transverse parameters of the line in pu</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >No.</th><th align="center" valign="middle" >Sections</th><th align="center" valign="middle" >R</th><th align="center" valign="middle" >X</th><th align="center" valign="middle" >G</th><th align="center" valign="middle" >B</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >1 - 2</td><td align="center" valign="middle" >0.025</td><td align="center" valign="middle" >0.27</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >2 - 3</td><td align="center" valign="middle" >0.17</td><td align="center" valign="middle" >0.4</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0.43</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >3 - 4</td><td align="center" valign="middle" >0.012</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr></tbody></table></table-wrap><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> Active and reactive powers at the nodes of the pu network</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >No.</th><th align="center" valign="middle" >P<sub>G</sub></th><th align="center" valign="middle" >Q<sub>G</sub></th><th align="center" valign="middle" >P<sub>C</sub></th><th align="center" valign="middle" >Q<sub>C</sub></th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >4</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr></tbody></table></table-wrap></sec><sec id="s3_3_3"><title>3.3.3. Simulations, Results and Discussion</title><p>The simulations are performed during no-load operation using the Newton-Raphson algorithm implemented in Matlab [<xref ref-type="bibr" rid="scirp.107009-ref9">9</xref>]. The results obtained are presented in the following <xref ref-type="table" rid="table8">Table 8</xref>.</p><p>From the results obtained, we can deduce the reactive powers generated by the capacitors formed between conductors using formula (2). These are presented in <xref ref-type="table" rid="table9">Table 9</xref> below. At the end of these deductions, we will appreciate the influence of these capacitive effects on the transformers windings located upstream and downstream of the line.</p></sec><sec id="s3_3_4"><title>3.3.4. Inductance Deduction</title><p>It is interesting to appreciate the inductances of the transformers windings which consume the reactive energy generated by the capacitors thus formed. The consumption of this energy varies according to the coupling of the windings.</p></sec></sec></sec><sec id="s4"><title>1) Triangle coupling of windings</title><p>By applying formulas (3), (4) and (5), we obtain the results given in <xref ref-type="table" rid="table1">Table 1</xref>0 below:</p></sec><sec id="s5"><title>2) Star coupling of windings</title><p>Assuming that the system is symmetrical, solving Equations (17), (18) and (19) allows us to obtain the results recorded in <xref ref-type="table" rid="table1">Table 1</xref>1 below:</p><p>The examination of the results recorded in <xref ref-type="table" rid="table1">Table 1</xref>0 and <xref ref-type="table" rid="table1">Table 1</xref>1 show that the geometry of the conductors in an equilateral triangle guarantees the symmetry of the three-phase system; however, the star coupling is more expensive, because the windings of this one can have a number of turns 3 times less than that of the transformer whose coupling of the windings is in triangle.</p><table-wrap id="table8" ><label><xref ref-type="table" rid="table8">Table 8</xref></label><caption><title> Voltage modules and phases, then powers generated and consumed at the nodes in pu</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >No.</th><th align="center" valign="middle" >V</th><th align="center" valign="middle" >φ</th><th align="center" valign="middle" >P<sub>G</sub></th><th align="center" valign="middle" >Q<sub>G</sub></th><th align="center" valign="middle" >P<sub>C</sub></th><th align="center" valign="middle" >Q<sub>C</sub></th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >1.0200</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0.0195</td><td align="center" valign="middle" >−0.5323</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >1.1606</td><td align="center" valign="middle" >−0.0157</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >1.2688</td><td align="center" valign="middle" >−0.0556</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >4</td><td align="center" valign="middle" >1.2688</td><td align="center" valign="middle" >−0.0556</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0</td></tr></tbody></table></table-wrap><table-wrap id="table9" ><label><xref ref-type="table" rid="table9">Table 9</xref></label><caption><title> Reactive powers generated during no-load operation</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Reactive powers</th><th align="center" valign="middle"  colspan="3"  >110 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >Q<sub>12</sub> (MVAR)</td><td align="center" valign="middle" >7.4454</td><td align="center" valign="middle" >7.4454</td><td align="center" valign="middle" >7.4454</td></tr><tr><td align="center" valign="middle" >Q<sub>13</sub> (MVAR)</td><td align="center" valign="middle" >6.7089</td><td align="center" valign="middle" >7.4454</td><td align="center" valign="middle" >7.0579</td></tr><tr><td align="center" valign="middle" >Q<sub>23</sub> (MVAR)</td><td align="center" valign="middle" >7.4454</td><td align="center" valign="middle" >7.4454</td><td align="center" valign="middle" >7.4454</td></tr></tbody></table></table-wrap><table-wrap id="table10" ><label><xref ref-type="table" rid="table1">Table 1</xref>0</label><caption><title> Inductances values of the windings transformer</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Inductances</th><th align="center" valign="middle"  colspan="3"  >110 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >L<sub>12</sub> (H)</td><td align="center" valign="middle" >8.3321</td><td align="center" valign="middle" >8.3321</td><td align="center" valign="middle" >8.3321</td></tr><tr><td align="center" valign="middle" >L<sub>23</sub> (H)</td><td align="center" valign="middle" >8.3321</td><td align="center" valign="middle" >8.3321</td><td align="center" valign="middle" >8.3321</td></tr><tr><td align="center" valign="middle" >L<sub>13</sub> (H)</td><td align="center" valign="middle" >9.2468</td><td align="center" valign="middle" >8.3321</td><td align="center" valign="middle" >8.7895</td></tr></tbody></table></table-wrap><table-wrap id="table11" ><label><xref ref-type="table" rid="table1">Table 1</xref>1</label><caption><title> Inductances values of the transformer’s windings</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >inductances</th><th align="center" valign="middle"  colspan="3"  >110 KV</th></tr></thead><tr><td align="center" valign="middle" >Nappe</td><td align="center" valign="middle" >Equilateral Triangle</td><td align="center" valign="middle" >Isocel Triangle</td></tr><tr><td align="center" valign="middle" >L<sub>1</sub> (H)</td><td align="center" valign="middle" >2.777</td><td align="center" valign="middle" >2.777</td><td align="center" valign="middle" >2.777</td></tr><tr><td align="center" valign="middle" >L<sub>2</sub> (H)</td><td align="center" valign="middle" >3.082</td><td align="center" valign="middle" >2.777</td><td align="center" valign="middle" >2.929</td></tr><tr><td align="center" valign="middle" >L<sub>3</sub> (H)</td><td align="center" valign="middle" >2.777</td><td align="center" valign="middle" >2.777</td><td align="center" valign="middle" >2.777</td></tr></tbody></table></table-wrap></sec><sec id="s6"><title>4. Conclusions</title><p>In our study, we first modeled the line by essentially representing discrete capacitors between active conductors on the one hand, and between active conductors and the ground on the other. Then we calculated the capabilities of discrete capacitors. Similarly, equivalent capacities were deducted. In the end, the examination of the influence of capacitive effects on transformer coils was done on the existing radial power grid in the Republic of Congo. The results show that:</p><p>● Discrete capacitors generate reactive energies that vary depending on the geometry of line conductors;</p><p>● Capacitive effects affect transformer coils differently depending on whether the coupling is in a triangle or a star;</p><p>• For triangle coupling, the coiling of the transformer's coil consumes all of the energy generated;</p><p>• For star coupling, the energy generated is consumed by the two coils of the transformer’s coils.</p><p>In short, the design of line conductors in equilateral triangle is ideal compared to other models when it comes to ensuring the symmetry of the three-phase system. However, star coupling is more advantageous than triangle coupling, as the number of coils spins is reduced by 3 times and the coil induction will be 3 times smaller, and therefore the star coupling guarantees a long life of the transformer compared to the one whose coupling is in a triangle.</p></sec><sec id="s7"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s8"><title>Cite this paper</title><p>Gogom, M., Gomba, R. and Lilonga-Boyenga, D. (2021) Influence of Capacitive Effects on Transformer Windings. Energy and Power Engineering, 13, 67-80. https://doi.org/10.4236/epe.2021.132005</p></sec></body><back><ref-list><title>References</title><ref id="scirp.107009-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Lyazid, H. and Khodir, H. (2015) Calcul des Paramètres et Caractéristiques des Lignes électriques Triphasées. Mémoire de Master 2 Génie électrique, Université Abderrahmane Mira, Béja&amp;iuml;a.</mixed-citation></ref><ref id="scirp.107009-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Wildi, T. and Sibille, G. (2005) Electrotechnique. 4e édition, Presses de l'Université Laval, Québec.</mixed-citation></ref><ref id="scirp.107009-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Abba Labane, H. and Omboua, A. (2016) Capacitive Dividers on the High Voltage Lines. International Journal of Engineering and Advanced Research Technology, 2, 26-32.</mixed-citation></ref><ref id="scirp.107009-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Abba Labane, H., Omboua, A. and Lilonga-Boyenga, D. (2017) Capacitive Effects on Electrical Lines and Cables. International Journal of Engineering Science Invention, 6, 25-32.</mixed-citation></ref><ref id="scirp.107009-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Sayah, A. (2017) Analyse des Terminaisons d’Eau. Thèse de l’Université des Sciences et de la Technologie d’Oran Mohamed Boudiaf, Bir El Djir.</mixed-citation></ref><ref id="scirp.107009-ref6"><label>6</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Omboua</surname><given-names> A. </given-names></name>,<etal>et al</etal>. (<year>2017</year>)<article-title>Soutirage de l’énergie le Long des Lignes à Haute Tension: Technologie Profitable Pour les Pays en Développement</article-title><source> International Journal of Innovation and Applied Studies</source><volume> 20</volume>,<fpage> 349</fpage>-<lpage>357</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.107009-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Lagonotte, P. (2004) Les Lignes et Des Cables électriques. In Chapitre 10 du Cours de Réseaux électrique.</mixed-citation></ref><ref id="scirp.107009-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Yalaoui, N. (2017) Calcul de la Matrice d’Impédances Linéiques du Système Ligne-Cable Avec la Méthode des éléments Finis. Mémoire du Dipl&amp;ocirc;me de Maitrise ès Sciences Appliquées Soutenu en 2017.</mixed-citation></ref><ref id="scirp.107009-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Gogom, M., Mimiesse, M., Nguimbi, G. and Lilonga-Boyenga, D. (2018) Improving Availability of Transit Capacity by the Hybrid Optimization Method. Journal of Scientific and Engineering Research, 5, 1-13.</mixed-citation></ref><ref id="scirp.107009-ref10"><label>10</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Dan Surianu</surname><given-names> F. </given-names></name>,<etal>et al</etal>. (<year>2009</year>)<article-title>Determination of the Induced Voltages bby 220 kV Electric Overhead Power Lines Working in Parallel and Narrow Routes. Measurements on the Ground and Mathematical Model</article-title><source> WSEAS Transactions on Power Systems</source><volume> 4</volume>,<fpage> 264</fpage>-<lpage>274</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.107009-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Souad, C. (2013) Réseaux électriques en ses Divers Régimes Cours. Université Virtuelle de Tunis, Montplaisir, 23, 27.</mixed-citation></ref><ref id="scirp.107009-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Boukhenoufa, F., Boukadoum, A., Leulmi, A., et al. (2012) Régulation Optimale de la Tension &amp; Compensation de la Puissance Réactive avec Contraintes de Sécurité, d’un Réseau électrique, par la Méthode Hybride MPI &amp; AG, Université du 20 Ao&amp;ucirec;t 1955 et Université Ferhat A., Skikda-Sétif (Algérie), 1-6.</mixed-citation></ref><ref id="scirp.107009-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Betie, A. (2015) Impacts de la Qualité du Système d’Isolation sur la Condition et l’Efficacité des Transformateurs de Puissance. Thèse de l’Université du Québec, Quebec City.</mixed-citation></ref></ref-list></back></article>