<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">WJCMP</journal-id><journal-title-group><journal-title>World Journal of Condensed Matter Physics</journal-title></journal-title-group><issn pub-type="epub">2160-6919</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/wjcmp.2020.104010</article-id><article-id pub-id-type="publisher-id">WJCMP-104030</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  The Total Energy in the Interaction of X-Ray Photons with Capacitors
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>S.</surname><given-names>I. Hassan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>G.</surname><given-names>Scarel</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Physics and Astronomy, James Madison University, Harrisonburg, VA, USA</addr-line></aff><pub-date pub-type="epub"><day>11</day><month>11</month><year>2020</year></pub-date><volume>10</volume><issue>04</issue><fpage>159</fpage><lpage>177</lpage><history><date date-type="received"><day>24,</day>	<month>September</month>	<year>2020</year></date><date date-type="rev-recd"><day>8,</day>	<month>November</month>	<year>2020</year>	</date><date date-type="accepted"><day>11,</day>	<month>November</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Context and Background: In this research, we investigate the interaction of X-rays with a capacitor by studying the voltage established in the capacitor during the illumination. 
  Motivation: We aim at verifying that the total energy conserved in the interaction is 
  
  Pτ, i.e. the product of the average power 
  
  P times the period τ of the X-rays. 
  Hypothesis: Our investigation relies on the hypothesis that the voltage responsivity π
  
  <sub>V</sub> of the capacitor should be small, according to previous research. The parameter π
  
  <sub>V</sub> is the ratio between the voltage produced and the average power 
  
  P of the X-rays, and measures the performance of the capacitor in response to the X-rays. 
  Method: We measure the voltage produced by the capacitor in response to the X-rays, and then determine the average power 
  
  P of the X-rays according to a procedure already assessed with infrared and visible light. 
  Results: In our experiments, 
  
  P turns out to be in the range between 10
  <sup>-3 </sup>W to 10
  <sup>0</sup> W. Our procedure enables us to unveil the relationship between the average power P and the effective dose, an important operating parameter used to measure the delivery of X-rays in practical applications, such as standard X-ray medical imaging machines. 
  Conclusions: We believe that our procedure paves the way for designing a possible X-ray power-meter, a tool presently missing in the market of X-ray characterization tools.
 
</p></abstract><kwd-group><kwd>X-Rays</kwd><kwd> Power</kwd><kwd> Light-Matter Interaction</kwd><kwd> Conservation of Energy</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Our main research goal is to explore the interaction between electromagnetic (EM) waves and matter and to find a law capable of consistently and quantitatively explaining such interaction throughout the whole EM spectrum. Significant effort was spent in exploring the interaction of visible and infrared (IR) light with matter. Here we focus on the high frequency region of the EM spectrum, i.e. to X-rays, by applying and assessing in this region the same law of conservation of energy successfully tested in the visible and IR light regions.</p><p>Currently several questions remain without clear answer in considering phenomena related to the EM wave interaction with matter. How much is the total energy conserved in light-matter interaction? Usually, researchers respond adopting a microscopic point of view in which photons transfer their energy hν (where h is Planck’s constant and ν is the photon’s frequency) to electrons or other charges. However, when EM waves interact with a macroscopic object such as a sensor, a detector, or an energy harvester, their energy hν does not directly answer the question stated previously. Specifically, through hν it becomes difficult to correlate the response (i.e. the voltage, current, or temperature change) of sensor, detector, or energy harvester, to the power, or the intensity, of the absorbed EM wave. Vice-versa, it is hard to associate the power or intensity of the EM wave to the magnitude of the electric currents producing them in an EM wave generator. This difficulty proposes several questions in diverse physical situations. For example, why, in response to dim light at an intensity of few mW∙m<sup>−2</sup> (10<sup>−3</sup> W∙m<sup>−2</sup>), is the current generated in rod cells, or photoreceptors in the eye’s retina, of the order of pA (10<sup>−12</sup> A) [<xref ref-type="bibr" rid="scirp.104030-ref1">1</xref>] ? Why, in the bulk photovoltaic effect with the absorption of IR light at 10.6 μm wavelength and 10 to 300 mW power, is the produced current of the order of μA (10<sup>−6</sup> A) [<xref ref-type="bibr" rid="scirp.104030-ref2">2</xref>] ? More generally, why is sensitivity steadily around 0.045 mAW<sup>−1</sup> for photocurrents generated in different devices with red and IR light in the 1 to 200 mW power range [<xref ref-type="bibr" rid="scirp.104030-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.104030-ref3">3</xref>] ? On the other hand, why, in free-electron-based light sources, do electrons need to move close to the speed of light to emit ultraviolet (UV) light at a power of the order of only pW to nW (10<sup>−9</sup> W) [<xref ref-type="bibr" rid="scirp.104030-ref4">4</xref>] ? Finally, why, when illuminated by visible and IR light with power in the mW range, do capacitors with capacitance of the order of pF produce voltages in the mV range [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] ?</p><p>Recent efforts provide a strategy to correlate the response (i.e. the voltage, current, or temperature change) of sensors, detectors and energy harvesters, to the power, or the intensity, of the absorbed EM waves. In these efforts, the law of conservation of energy is called into play [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. Specifically, in absorption phenomena, the EM wave’s total energy is matched to the energy transferred to the absorbing device (sensors, detectors, and energy harvesters). This match is effective when the total energy of the EM waves is expressed as the product of their average power P and their period τ, i.e. Pτ, as proven in the case of the absorption of IR and visible light by capacitors [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.104030-ref6">6</xref>]. Mathematical details are provided in the Appendix. Examples of the effectiveness of the approach based on Pτ as the total energy are: the absorption of IR light by thin films in IR spectra [<xref ref-type="bibr" rid="scirp.104030-ref7">7</xref>], of visible light by the retina in vertebrate’s vision [<xref ref-type="bibr" rid="scirp.104030-ref8">8</xref>], by molecules in photoredox catalysis reactions [<xref ref-type="bibr" rid="scirp.104030-ref9">9</xref>], in photo-thermoelectric devices [<xref ref-type="bibr" rid="scirp.104030-ref9">9</xref>], and by neurons under two-photon excitation [<xref ref-type="bibr" rid="scirp.104030-ref9">9</xref>]. Vice-versa, in emission phenomena, Pτ is effective in a number of cases. For example, one is high-order multiphoton Thomson scattering [<xref ref-type="bibr" rid="scirp.104030-ref10">10</xref>], where the collision of a near IR laser beam with relativistic electrons gives rise to X-rays. Another example is the quantification of the power of the anomalous microwave emission (AME) by spinning dust in the interstellar medium [<xref ref-type="bibr" rid="scirp.104030-ref11">11</xref>]. A third example is the estimation of the power emitted by radio waves produced in the interaction between a red dwarf and an exoplanet [<xref ref-type="bibr" rid="scirp.104030-ref12">12</xref>]. However, the effectiveness of Pτ and the law of conservation of energy, expected to be valid in all manifestations of light-matter interaction, whether in absorption or in emission phenomena, is not yet assessed in the high frequency region of the EM spectrum, e.g. with X-rays. This assessment is the objective of this research.</p><p>We investigate the interaction of X-rays with a capacitor adopting a method similar to that in previous research [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. Capacitors respond to visible and IR light through the production of a voltage with magnitude constrained by light’s power P [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.104030-ref6">6</xref>]. The capacitors used in Refs. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] and [<xref ref-type="bibr" rid="scirp.104030-ref6">6</xref>] are, actually, thermoelectric devices, whose multilayer structure mimics a capacitor with estimated capacitance C of the order of pF (10<sup>−12</sup> F) [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.104030-ref6">6</xref>]. The ability of capacitors to respond to light is widely documented in nature. Indeed, natural capacitors, such as the retinal neuron cells, respond to visible light with voltage production depending upon light’s power P [<xref ref-type="bibr" rid="scirp.104030-ref8">8</xref>]. Specifically, retinal neuron cells are compared to capacitors because their membrane acts as the capacitor’s dielectric layer, while the intra- and extracellular conducting fluids, that flank the membrane, act as the capacitor’s electrodes. The membrane’s capacitance C is of the order of 6 - 8 pF [<xref ref-type="bibr" rid="scirp.104030-ref13">13</xref>]. Such order of magnitude of the capacitance is common: for instance, in the hippocampus of behaving mice, the magnitude of the neuron’s capacitance is around 50 pF [<xref ref-type="bibr" rid="scirp.104030-ref14">14</xref>].</p><p>To assess the effectiveness of Pτ and the law of conservation of energy in the absorption of X-rays by a capacitor, we first measure the voltage ΔV(t) produced versus timet by the capacitor, and then estimate the average power P of the X-rays through Pτ. Contemporarily, we collect the temperature T<sub>hot</sub>(t) generated on the capacitor’s face exposed to the X-rays. This procedure is the same as that adopted in Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. We then assess the value of the average power P by following two routes. The first consists of determining if the value of P complies with the performance of a standard X-ray medical machine and of an X-ray diffractometer. The second route consists of computing the voltage responsivity π<sub>V</sub> of capacitors and comparing it to the value expected from the model based on Pτ. The voltage responsivity π<sub>V</sub> measures the effectiveness of the capacitor’s response to the EM waves, and is expected to increase with decreasing frequency ν (or with increasing period τ) of the EM waves [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. We probe this trend of π<sub>V</sub> with pulsed X-rays in a standard medical machine and continuous X-rays in a diffractometer. Finally, we discuss our findings.</p></sec><sec id="s2"><title>2. Experimental Details</title><p>The X-ray sources: The main X-ray source we used in our experiment was originally designed for medical imaging. Therefore, we expect the performance of the X-ray source to be standard for medical imaging X-ray machines. The X-rays used in our experiment are 40 keV in energy, and are produced with a 10 mA source current. We used 40 kV to maximize the amount of absorbed beam. Indeed, at higher energies, much more of the X-ray energy would pass through the capacitor, whereas at lower energy nearly all of it should be absorbed and the observed signal be above the background. In our set-up, the distance between the X-ray source and the capacitor is 90 cm, and the beam size is 4 cm<sup>2</sup>. The X-rays have a broad spectrum, however, given their 40 keV energy, we expect the X-rays to have a frequency ν centered around 9.65 &#215; 10<sup>18</sup> Hz, and a period τ = ν<sup>−1</sup> centered around 0.104 &#215; 10<sup>−18</sup> s. The average power of the X-rays is unknown, and estimating its value is one of the objectives of this research. We directed these X-rays normally to the capacitor’s surface.</p><p>We also used Cu K-α and -β X-rays obtained from a powder X-ray diffractometer (PXRD) (X’pert PANalytical) with average wavelength λ~1.5406 &#215; 10<sup>−10</sup> m, average frequency ν~1.947 &#215; 10<sup>18</sup> Hz, and average period τ~0.51 &#215; 10<sup>−18</sup> s. The beam size is 4 cm<sup>2</sup>. We directed also these X-rays normally to the capacitor’s surface.</p><p>The Capacitors: The main capacitor used to test the interaction with X-rays is a stack of three Custom Thermoelectric 07111-9L31-04B modules. Each module has a length of ≈23 mm along the x- and the y-axes, and a height h = 3 mm. Moreover, each module is designed to produce a voltage difference ΔV when exposed to a temperature difference ΔT between the illuminated (T<sub>hot</sub>) and non-illuminated (T<sub>cold</sub>) faces. This effect is the Seebeck effect: ΔV = SΔT, where S is the Seebeck coefficient and ΔT = T<sub>hot</sub> − T<sub>cold</sub>. Finally, each module is a multilayer of AlO-Cu-Bi<sub>2</sub>Te<sub>3</sub>-Cu-AlO, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. The multilayer structure</p><p>of each module, and the in-series combination of three of them, makes the overall device comparable to a capacitor [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. In addition, placing an insulating layer on the face directly exposed to the X-rays, enables an equivalent capacitance C of ~42 pF within the X-ray’s beam size of 4 cm<sup>2</sup>. The value ε of the dielectric constant is ε = 1.423, as computed from</p><p>C = ε ε 0 area h</p><p>where ε<sub>0</sub> = 8.854 &#215; 10<sup>−12</sup> Fm<sup>−1</sup> is the permittivity in vacuum.</p><p>We also used a 89 pF capacitor, which we built by assembling two Custom Thermoelectric 07111-9L31-04B modules and a 07111-5L31-03CJ module. The value ε of the dielectric constant in this case is ε ≈ 2.</p><p>In our experiments, we assume the value of the capacitance C to be constant both in time, space, and for all frequencies of the EM waves. During the illumination with the X-rays, the capacitor is kept within two expanded polystyrene (EPS) enclosures to shield it from background noise.</p><p>Data Acquisition: Using Keithley 2000 multi-meters, capable of reading direct current (DC) voltages from 100 nV to 1 kV, we acquired the voltage difference ΔV(t) and the temperature T<sub>hot</sub>(t) as a function of time t. We measured T<sub>hot</sub>(t) using OMEGA type J self-adhesive thermocouple probes. The data collection lasted 50 minutes. During the first 30 minutes, called the relaxation interval, the data points were collected at low rate (one per minute) to monitor the relaxation of the capacitor in the EPS enclosures without exposure to the X-rays. During the final 20 minutes, called the illumination interval, the data collection under X-ray bombardment occurred at an increased rate (two per second) to visualize the effects on ΔV(t) and T<sub>hot</sub>(t) of five 120 s long X-ray pulses. We allowed a time interval of three minutes between one pulse and the next. In both the relaxation and the illumination intervals, we contemporarily collected ΔV(t) andT<sub>hot</sub>(t) using LabView 2012 and a National Instruments PXI-1042q communications chassis. We used OriginPro 2018 for analyzing the data.</p></sec><sec id="s3"><title>3. Results</title><p>The trends in time of T<sub>hot</sub>(t) and ΔV(t) collected versus time from the 42 pF capacitor with and without the 40 keV X-ray illumination are shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>(a) and <xref ref-type="fig" rid="fig2">Figure 2</xref>(b), respectively. We identify two intervals in the graphs. The first corresponds to the relaxation interval, in which the 42 pF capacitor is not exposed to the 40 keV X-rays. The second interval corresponds to the illumination interval, which describes the evolution of T<sub>hot</sub>(t) and ΔV(t) upon exposing the 42 pF capacitor to five 120 s long X-rays pulses.</p><p>We observe that, in the relaxation interval, approximately 20 minutes after starting the data collection, T<sub>hot</sub>(t) rises, followed about 10 minutes later by the rise of ΔV(t). We ascribe the rise of both T<sub>hot</sub>(t) and ΔV without X-rays to background noise, which affects the 42 pF capacitor probably due to the insufficient shielding offered by the EPS enclosures. To mitigate the influence of background</p><p>noise, in the data analysis process we subtract the background from the acquired T<sub>hot</sub>(t) and ΔV(t) data.</p><p><xref ref-type="fig" rid="fig3">Figure 3</xref> focuses on three zones in the illumination interval exhibiting the response versus time t of the 42 pF capacitor to 120 s long exposures to the 40 keV X-rays. The responses of T<sub>hot</sub>(t) and ΔV(t) are shown after background subtraction. The top row of <xref ref-type="fig" rid="fig3">Figure 3</xref> (panels (a), (c) and (e)) reports the trend in time of T<sub>hot</sub>(t), while the bottom row (panels (b), (d) and (f)) reports those for ΔV(t). We observe that the 40 keV X-rays cause a blip in both T<sub>hot</sub>(t) and ΔV(t). In all three cases, the blip of T<sub>hot</sub> is pronounced and relatively narrow, confined within the 120 s exposure time to the X-rays. The amplitude ΔT<sub>hot</sub> of the blip in T<sub>hot</sub> varies between 0.045˚C and 0.1˚C, and its average value is (0.065 &#177; 0.030)˚C. On the other hand, in all three cases, the blip in voltage ΔV is pronounced but rather broad, rising at the beginning of the illumination pulse and declining at the end of it. The amplitude of the blip in voltage ΔV varies between 2.5 μV and 5 μV, with an average value of (3.5 &#177; 1.3) μV. The ratio R between the amplitudes of the blips in ΔV and ΔT<sub>hot</sub> is on average (0.055 &#177; 0.005) mV/˚C for the three examined pulses. This value is two orders of magnitude lower than the R value found in the interaction between capacitors and visible light (R = 3.7 &#177; 0.2 mV/˚C with green light) and IR light (R = 21.5 &#177; 3.8 mV/˚C) [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. Since the R value seems to decrease with increasing frequency ν (decreasing period τ), we find perfectly acceptable the low value of R under X-ray illumination in our experiment.</p><p><xref ref-type="fig" rid="fig4">Figure 4</xref> focuses on three 120 s long zones in the illumination interval in which the 42 pF capacitor is not exposed to the 40 keV X-rays. In all panels, the responses of T<sub>hot</sub>(t) and ΔV(t) versus time t are presented without background subtraction. The top row of <xref ref-type="fig" rid="fig4">Figure 4</xref> (panels (a), (c) and (e)) illustrates T<sub>hot</sub>(t), while the bottom row (panels (b), (d) and (f)) displays ΔV(t). In all panels, ΔV(t) increase linearly versus time, without blips. However, in panel (f), ΔV(t) bends because it falls precisely where in the illumination interval ΔV(t) achieves the plateau, visible in the top-right corner of <xref ref-type="fig" rid="fig2">Figure 2</xref>(b). On the other hand, T<sub>hot</sub>(t)</p><p>in panel (c) decreases linearly versus time, whereas it is flat in panel (e). Only panel (a) shows a blip of about 0.05˚C, i.e. of the same order of magnitude of the blips detected upon exposure of the 42 pF capacitor to the 40 keV X-rays in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The origin of this blip in T<sub>hot</sub>(t), visible in <xref ref-type="fig" rid="fig4">Figure 4</xref>(a), is for the moment, uncertain. Overall, the comparison between <xref ref-type="fig" rid="fig3">Figure 3</xref> and <xref ref-type="fig" rid="fig4">Figure 4</xref>, considering that no background subtraction was applied to the data in <xref ref-type="fig" rid="fig4">Figure 4</xref>, suggests that the blips in ΔV(t) found in <xref ref-type="fig" rid="fig3">Figure 3</xref>(b), <xref ref-type="fig" rid="fig3">Figure 3</xref>(d) and <xref ref-type="fig" rid="fig3">Figure 3</xref>(f) are a consequence of the 120 s long exposure of the 42 pF capacitor to the 40 keV X-rays.</p><p>Previous research [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] used the law of conservation of energy to quantify the energy involved in the interaction between EM waves and a capacitor. The law of conservation of energy is expressed in the following equation:</p><p>P τ = 1 2 C Δ V 2 + 1 2 q 2 C − Σ 0 Δ T (1)</p><p>More details about the derivation of this equation are provided in the Appendix. In Equation (1), Pτ is the total energy conserved in the interaction between EM waves and a capacitor. The variables C and ΔV are, respectively, the capacitance of the capacitor, and the amplitude of the blip in voltage generated by the EM waves interacting with the capacitor. The variable q, in the second addend of Equation (1), is the amount of charge displaced by the EM waves upon their arrival on the surface of the capacitor [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. Finally, in the third addend of Equation (1), the variable ΔT is the amplitude ΔT<sub>hot</sub> of the blip of the temperature T<sub>hot</sub>, and Σ<sub>0</sub> is entropy. All addends in Equation (1) are required to be of the same order of magnitude of Pτ, and vice-versa, in order to be significant. Otherwise, if they are too small they are neglected, if they are too big they prevail. A similar use of constraints is employed by the authors of Ref. [<xref ref-type="bibr" rid="scirp.104030-ref12">12</xref>] to estimate the surface magnetic field of the red dwarf emitting radio waves.</p><p>Here we apply Equation (1) to the interaction between X-rays and a capacitor to determine the average power P of the X-rays. To this end, we exploit the constraint that all addends in Equation (1) must to be of the same order of magnitude of Pτ, and vice-versa, to be significant. This constraint enables us to estimate P as:</p><p>P ~ 1 2 C Δ V 2 (2)</p><p>The values of P we found using Equation (2) for the three pulses in <xref ref-type="fig" rid="fig3">Figure 3</xref> are summarized in <xref ref-type="table" rid="table1">Table 1</xref>. On average, the power of the 40 keV X-rays is</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Amplitude of three blips in voltage ΔV measured during the illumination of a 42 pF capacitor with a 2 minute long 40 keV X-rays pulse. The three blips are depicted in <xref ref-type="fig" rid="fig3">Figure 3</xref>, panels (b), (d), and (f). Average power P of the 40 keV X-rays pulse hitting the 42 pF capacitor estimated using Equation (2). The average value of P is (2.96 &#177; 2.40) mW. Finally, voltage responsivity π<sub>V</sub> = ΔV/P estimated for the three blips in voltage ΔV depicted in <xref ref-type="fig" rid="fig3">Figure 3</xref>, panels (b), (d), and (f). The average value of π<sub>V</sub> is (1.50 &#177; 0.56) 10<sup>−3</sup> V/W</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Panel in <xref ref-type="fig" rid="fig3">Figure 3</xref></th><th align="center" valign="middle" >ΔV [μV]</th><th align="center" valign="middle" >Average Power P [mW]</th><th align="center" valign="middle" >Responsivity π<sub>V</sub> [10<sup>−3</sup> V/W]</th></tr></thead><tr><td align="center" valign="middle" >(b)</td><td align="center" valign="middle" >5</td><td align="center" valign="middle" >5.67</td><td align="center" valign="middle" >0.88</td></tr><tr><td align="center" valign="middle" >(d)</td><td align="center" valign="middle" >2.5</td><td align="center" valign="middle" >1.27</td><td align="center" valign="middle" >1.97</td></tr><tr><td align="center" valign="middle" >(f)</td><td align="center" valign="middle" >3</td><td align="center" valign="middle" >1.82</td><td align="center" valign="middle" >1.65</td></tr></tbody></table></table-wrap><p>P = (2.96 &#177; 2.40) mW. Interestingly, this value of power is within the range (from 3 μW to 20 mW) measured for synchrotron X-rays [<xref ref-type="bibr" rid="scirp.104030-ref15">15</xref>]. This observation suggests that the value we have found is reasonable. Knowing P, we estimate the average value of the total energy as Pτ = 0.31 &#215; 10<sup>−21</sup> J. Proceeding in the same way from Equation (1), and using the average value of the amplitude of the blip in T<sub>hot</sub> (0.065˚C &#177; 0.030˚C), we determine the average value of the entropy Σ<sub>0</sub> as ~4.7 10<sup>−21</sup> J/˚C. Similarly, since the capacitance C of the capacitor is 42 pF, the displaced charge q in Equation (1) is estimated to be of the order of ~1.61 &#215; 10<sup>−16</sup>˚C.</p></sec><sec id="s4"><title>4. Discussion</title><p>In our experiment, two routes help assessing whether Pτ is the total energy conserved in X-ray absorption. Both routes exploit the average power P = 2.96 mW that we estimated through Pτ and the law of conservation of energy. The first route verifies that P = 2.96 mW supports the performance of the standard medical X-ray imaging machine we used in our experiment. The second route compares with trends established for other EM waves, the voltage responsivityπ<sub>V</sub> [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] imposed by P = 2.96 mW on the 42 pF capacitor [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. Indeed, predictions involving a broad range of EM waves indicate that the voltage responsivity π<sub>V</sub> generated in capacitors decreases by several orders of magnitude under illumination with EM waves of increasing frequency ν (or decreasing period τ, or wavelength λ). Radio waves are expected to yield larger voltage responsivities than IR and visible light [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. We thus expect the voltage responsivities generated by X-rays to be smaller than those generated by the other EM waves, in particular visible and IR light, and radio waves.</p><sec id="s4_1"><title>4.1. The X-Ray Power in a Standard X-Ray Imaging Medical Machine</title><p>Power-meters responsive to visible light easily allow measuring the power of an optical laser beam. Unfortunately, power meters responsive to X-rays are at the infancy of their development and, to date, are only in use for research purposes [<xref ref-type="bibr" rid="scirp.104030-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.104030-ref16">16</xref>]. Usually these power meters are large, heavy, operating at low temperatures and difficult to operate. Even if compact and easy-to-use X-ray power-meters are available [<xref ref-type="bibr" rid="scirp.104030-ref15">15</xref>], neither power nor intensity (power per area) are operating parameters in standard medical X-ray imaging machines. Rather, these machines are set to deliver an effective dose (Δ<sub>eff</sub>, in units of Sv, Sievert, or J * kg<sup>−1</sup>) of X-rays on a specific patient’s organ. The effective dose Δ<sub>eff</sub> establishes the energy E<sub>abs</sub> = Δ<sub>eff</sub> m to be absorbed by the mass m within the organ to obtain the desired imaging or therapeutic goal. We call E<sub>abs</sub> the transferred energy, which differs from the total energy Pτ. Specifically, the transferred energy E<sub>abs</sub> is the amount of energy transferred to the mass m in a selected volume V independently of the exposure time Δt. Instead, the total energy Pτ corresponds to the amount of energy transferred within the period τ of the EM wave in the volume of matter hit by the EM wave. Analogously to Equation (1), we hypothesize that the total energy Pτ and the transferred energy E<sub>abs</sub> are related through the law of conservation of energy such that:</p><p>P τ = τ Δ eff m Δ t − Σ 0 Δ T</p><p>or</p><p>P τ = E abs τ Δ t − Σ 0 Δ T (3)</p><p>As in Equation (1), also in Equation (3) all addends, to be significant, are required to be of the same order of magnitude of Pτ. Therefore, we can approximate Equation (3) as follows:</p><p>P τ ~ τ Δ eff m Δ t = E abs τ Δ t (4)</p><p>Knowing both the mass m and the exposure time Δt, this approximation allows us to constrain the value of the average power P of the X-rays from the known value of the dose Δ<sub>eff</sub>. For instance, for a typical mammogram, Δ<sub>eff</sub> = 0.36 mSv or 0.36 mJ∙kg<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.104030-ref17">17</xref>]. The density of the breast tissue is, on average, δ = 0.985 g/cm<sup>3</sup>. Therefore, a volume V = 9 cm<sup>3</sup> (diameter d = 1.3 cm) of breast tissue has a mass m of about 8.86 &#215; 10<sup>−3</sup> kg. The transferred energy E<sub>abs</sub> = Δ<sub>eff</sub> m from the X-rays to the breast tissue, is therefore 3.19 &#215; 10<sup>−6</sup> J, and an exposure time Δt = 1.1 ms would be compatible with the average power P = 2.96 mW found with Pτ and the law of conservation of energy in Section 3. Similarly, with Δt = 0.2 s, which is the exposure time normally adopted in mammogram screenings, and assuming an average power P = 2.96 mW, a breast tissue volume V with a diameter d = 12 cm could be imaged. Thus, either V = 9 cm<sup>3</sup> (d = 1.3 cm) and Δt= 1.1 ms, or d = 12 cm and Δt = 0.2 s, represent realistic scenarios. From these examples, we conclude that the X-ray’s average power estimated asP = 2.96 mW satisfies the expectations on the performance of a standard medical X-ray imaging machine.</p><p>An additional example consists of using the X-rays of our standard medical machine to image wrist and hand bones. In this case, Δ<sub>eff</sub> = 4 mSv [<xref ref-type="bibr" rid="scirp.104030-ref17">17</xref>], and δ = 1.92 g/cm<sup>3</sup>. Thus, for V = 9 cm<sup>3</sup> (d = 1.3 cm), m is 17.3 &#215; 10<sup>−3</sup> kg, which determines a transferred energy E<sub>abs</sub> = 69.1 &#215; 10<sup>−6</sup> J. In this condition, an exposure time Δt = 0.02 s is compatible with the average power P = 2.96 mW. If we instead choose Δt= 0.2 s while P = 2.96 mW, we could image a wrist or hand bone volume of diameter d = 4 cm. Both scenarios are realistic, thus we conclude that also in imaging wrist and hand bones the average power P = 2.96 mW satisfies the expectations on the performance of a standard medical X-ray imaging machine.</p><p>Summarizing, in Section 3, using the total energy Pτ and the law of conservation of energy, we estimate the average power of the X-rays from a machine previously used for medical imaging to be P = (2.96 &#177; 2.40) mW. Subsequently, in Section 4.1, using the concept of transferred energy, we find that the average power P = 2.96 mW is compatible with the X-ray exposure time Δt typically applied to image patient’s organs. This result validates our approach for estimating the power of an X-ray beam with Pτ and the law of conservation of energy.</p></sec><sec id="s4_2"><title>4.2. The Responsivity π<sub>V</sub> of the 42 pF Capacitor under X-Ray Illumination</title><p>Responsivity is a parameter used to characterize the performance of devices such as sensors, detectors and energy harvesters under the effect of EM waves [<xref ref-type="bibr" rid="scirp.104030-ref18">18</xref>]. Analytically, responsivity is the ratio between the change in voltage, or current, produced by the specific device, and the power P of the EM wave that illuminates the device. For example, when the device produces a voltage change ΔV, the voltage responsivity is π<sub>V</sub> = ΔV/P. Similarly, when the device produces a current change ΔI, the current responsivity is π<sub>I</sub> = ΔI/P.</p><p>Using Pτ and the law of conservation of energy, Boone et al. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] found that the voltage responsivity π<sub>V</sub>= ΔV/P of capacitors illuminated by visible and IR light decreases with decreasing period τ of the EM waves. In other words, the capacitor’s responsivity π<sub>V</sub>is lower for visible than for IR light excitation. Consequently, we expect π<sub>V</sub> to be even lower with X-ray illumination of a capacitor. Our goal is to verify that, based upon the X-ray’s average power P = 2.96 mW found in our experiment (Section 3), the voltage responsivity π<sub>V</sub> of the capacitors illuminated by X-rays is lower than that produced under visible and IR light exposure. Thus, we evaluate π<sub>V</sub> by dividing the ΔV values in <xref ref-type="fig" rid="fig3">Figure 3</xref>, panels (b), (d), and (f) to the corresponding values of P, as summarized in <xref ref-type="table" rid="table1">Table 1</xref>. We report the voltage responsivity π<sub>V</sub> values in <xref ref-type="table" rid="table1">Table 1</xref>, and estimate their average to be (1.50 &#177; 0.56) &#215; 10<sup>−3</sup> V/W. With visible and IR light in the λ = 532 nm to 2000 nm wavelength range, or period range between 1.77 &#215; 10<sup>−15</sup> s to 6.67 &#215; 10<sup>−15</sup> s, the voltage responsivity π<sub>V</sub> varies between 2 &#215; 10<sup>−2</sup> to 2 &#215; 10<sup>−1</sup> V/W on a 18 pF capacitor [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]. These values are one to two orders of magnitude larger than 1.50 &#215; 10<sup>−3</sup> V/W. Since the difference in capacitance between 18 and 42 pF is small, we can safely state that the voltage responsivity π<sub>V</sub> of capacitors exposed to X-rays is lower, by at least one order of magnitude, than that produced by capacitors illuminated with visible and IR light. We therefore conclude that the voltage responsivity π<sub>V</sub>in our experiment with X-rays behaves as predicted in Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>].</p><p>In <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="table" rid="table2">Table 2</xref> we illustrate the trend of the voltage responsivity π<sub>V</sub> from X-rays (this research) to visible and IR light (Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] ) by showing π<sub>V</sub> as a function of the period τ of the EM waves. In <xref ref-type="fig" rid="fig5">Figure 5</xref>π<sub>V</sub>, which spans over thirteen orders of magnitude, appears on a logarithmic scale on the y-axis. The x-axis, also in logarithmic scale, covers thirteen orders of magnitude of the period τ. We include in the figure our preliminary data taken with radio waves, and fit the experimental points with the function π<sub>V</sub> ≈ 1 &#215; 10<sup>14</sup>τ C<sup>−1</sup> (here C = Coulomb). The datum corresponding to the illumination with the 40 keV X-ray pulses is marked as “pulsed”. This point is rather above the fitting line because of the weakness of the voltage signal generated. The datum that falls on the fitting line corresponds to measurements taken with continuous wave (cw) X-rays (data discussed below). Despite the uncertainties, we conclude that the trend,</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Comparison of ratio R (ratio between the amplitudes of the jumps of voltage ΔV and temperature ΔT<sub>hot</sub>), average power P, energy Pτ, entropy Σ<sub>0</sub>, charge q, and voltage responsivity π<sub>V</sub> involved in the interaction with a capacitor of 40 keV X-rays (this research), Cu K-α and -β X-rays (this research), visible and infrared (IR) light (Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] ). The trend of the voltage responsivity π<sub>V</sub> over the range from X-rays to IR light is further illustrated in <xref ref-type="fig" rid="fig5">Figure 5</xref></title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >40 keV X-rays (τ = 0.104 &#215; 10<sup>−18</sup> s), this research</th><th align="center" valign="middle" >Cu K-α and -β X-rays (τ~0.51 &#215; 10<sup>−18</sup> s), this research</th><th align="center" valign="middle" >visible and infrared light (from 1.77 &#215; 10<sup>−15</sup> s to 3.55 &#215; 10<sup>−15</sup> s), Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]</th></tr></thead><tr><td align="center" valign="middle" >R (mV/˚C)</td><td align="center" valign="middle" >0.055</td><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >from 3.7 &#177; 0.2 to 21.5 &#177; 3.8</td></tr><tr><td align="center" valign="middle" >average power P (mW)</td><td align="center" valign="middle" >2.96 (calculated)</td><td align="center" valign="middle" >14800 (calculated)</td><td align="center" valign="middle" >from 25 to 700 (experimental)</td></tr><tr><td align="center" valign="middle" >Pτ (J)</td><td align="center" valign="middle" >3.11 &#215; 10<sup>−22</sup></td><td align="center" valign="middle" >7.55 &#215; 10<sup>−18</sup></td><td align="center" valign="middle" >~9.64 &#215; 10<sup>−16</sup></td></tr><tr><td align="center" valign="middle" >Σ<sub>0</sub> (entropy, J/˚C)</td><td align="center" valign="middle" >4.7 &#215; 10<sup>−21</sup> (calculated)</td><td align="center" valign="middle" >1.45 &#215; 10<sup>−17</sup> (calculated)</td><td align="center" valign="middle" >~10<sup>−16</sup></td></tr><tr><td align="center" valign="middle" >q (charge, C)</td><td align="center" valign="middle" >1.61 &#215; 10<sup>−16</sup> (calculated)</td><td align="center" valign="middle" >3.7 &#215; 10<sup>−14</sup> (calculated)</td><td align="center" valign="middle" >~10<sup>−12</sup></td></tr><tr><td align="center" valign="middle" >π<sub>V</sub> (voltage responsivity mV/W)</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >0.028</td><td align="center" valign="middle" >from 20 to 200</td></tr></tbody></table></table-wrap><p>detected in <xref ref-type="fig" rid="fig5">Figure 5</xref>, of the voltage responsivity π<sub>V</sub> of capacitors exposed to X-rays also validates our approach to estimate the power of an X-ray beam with Pτ and the law of conservation of energy.</p></sec><sec id="s4_3"><title>4.3. Additional Assessment through the Illumination of an 89 pF Capacitor with Cu K-α and -β X-Rays</title><p>To further assess the ability of our procedure to effectively measure the average power P of X-rays, we exposed a 89 pF capacitor to Cu K-α and -β X-rays obtained from a powder X-ray diffractometer (PXRD) (X’pert PANalytical). We built the 89 pF capacitor by assembling two Custom Thermoelectric 07111-9L31-04B modules and a 07111-5L31-03CJ module. The X-rays have an average wavelength λ~1.5406 &#215; 10<sup>−10</sup> m, average frequency ν~1.947 &#215; 10<sup>18</sup> Hz, and average period τ~0.51 &#215; 10<sup>−18</sup> s. We directed the X-rays normally to the capacitor’s surface for about 20 minutes. Due to the impossibility of contemporarily fit three multi-meters in the housing of the X’pert PANalytical X-ray diffractometer, we asynchronously measured the trends in time of the voltage ΔV(t) and temperature T<sub>hot</sub>(t), shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>. The jumps of ΔV(t) and T<sub>hot</sub>(t) are well defined, and the data do not demand a background subtraction. We observe an amplitude of the jumps in voltage and temperature of ΔV = 0.41 mV and ΔT<sub>hot</sub> = 0.52˚C, respectively. From these amplitudes, and using a procedure similar to that adopted in Section 3 and Section 4.1, we estimate the ratio R between the amplitudes of the jumps of ΔV and ΔT<sub>hot</sub>, the average power P, the total energy Pτ, the entropy Σ<sub>0</sub>, the displaced charge q, and the voltage responsivity π<sub>V</sub>. These results are summarized in <xref ref-type="table" rid="table2">Table 2</xref>, where the quantities are compared to the corresponding ones obtained with the 40 keV X-rays (this research) and with visible and IR light (Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>] ). From these comparisons, we observe that the values of R produced by capacitors illuminated with X-rays are significantly smaller than those generated by capacitors exposed to visible and IR lights. This finding indicates that relatively larger temperature differences arise from the interaction of capacitors with EM waves at higher frequencies than at lower frequencies. This observation correlates with the finding that X-rays require a large value of average power P to give rise to even a small change in voltage ΔV, as inferred from the low values of the voltage responsivities π<sub>V</sub> in <xref ref-type="table" rid="table2">Table 2</xref>. Consequently, in standard medical X-ray imaging machines, P needs to be set at the lowest possible value to avoid danger for patients and operators, in agreement with our findings in Section 4.1. Finally, the value of the total energy Pτ and Equation (1) enable us to compute the entropy Σ<sub>0</sub> and the displaced charge q, as reported in <xref ref-type="table" rid="table2">Table 2</xref>.</p><p>One striking characteristics of the energy Pτ emerging from <xref ref-type="fig" rid="fig6">Figure 6</xref> needs further comments. The jump in voltage ΔV caused by the Cu K-α and -β X-rays on the 89 pF capacitor is of the same order of magnitude of that generated at</p><p>much lower average power P by green light from Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>], and radio waves from our preliminary data. The result is depicted in <xref ref-type="fig" rid="fig7">Figure 7</xref> and <xref ref-type="table" rid="table3">Table 3</xref>. The corresponding values of Pτ in the three cases turn out to be of the same order of magnitude. This observation suggests that waves with the same total energy Pτ produce similar effects, e.g. the same jump in voltage ΔV. Therefore, since X-rays have smaller values of the period τ than, e.g. visible light, it turns out that X-rays achieve the same energy Pτ of visible light with larger values of average power P than visible light. Accordingly, the effects of the average power P~3 mW of X-rays with period τ = 1 &#215; 10<sup>−19</sup> s produced by our standard medical X-ray imaging machine and generating a Pτ = 3 &#215; 10<sup>−22</sup> J, are the same as those due to green light at τ = 1.77 &#215; 10<sup>−15</sup> s with average power P~1.69 &#215; 10<sup>−7</sup> W!</p></sec></sec><sec id="s5"><title>5. Conclusions</title><p>In this research, we explore the interaction between X-rays and a capacitor. We achieve the following conclusions: 1) The product of the average power P times, the period τ, i.e. Pτ, is the total energy conserved in the absorption process also</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Summary of the similar experimentally measured jumps of voltage ΔV of about (0.51 &#177; 0.20) mV produced on a capacitor of capacitance C by electromagnetic (EM) waves of period τ, average power P, and total energy Pτ (average value 18.3 &#177; 22.6 J). As EM waves for this summary, we have chosen Cu K-α and -β X-rays from this research, green light from Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>], and radio waves from our preliminary data. The experimental trends of ΔV(t) under illumination of the capacitor by Cu K-α and -β X-rays, green light, and radio waves are summarized in <xref ref-type="fig" rid="fig7">Figure 7</xref></title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Cu K-α and -β X-rays, this research</th><th align="center" valign="middle" >Green light, Ref. [<xref ref-type="bibr" rid="scirp.104030-ref5">5</xref>]</th><th align="center" valign="middle" >Radio waves, preliminary data</th></tr></thead><tr><td align="center" valign="middle" >ΔV (mV)</td><td align="center" valign="middle" >0.41</td><td align="center" valign="middle" >0.75</td><td align="center" valign="middle" >0.39</td></tr><tr><td align="center" valign="middle" >C (pF)</td><td align="center" valign="middle" >89</td><td align="center" valign="middle" >270</td><td align="center" valign="middle" >42</td></tr><tr><td align="center" valign="middle" >τ (s)</td><td align="center" valign="middle" >0.51 &#215; 10<sup>−18</sup></td><td align="center" valign="middle" >1.77 &#215; 10<sup>−15</sup></td><td align="center" valign="middle" >10 &#215; 10<sup>−9</sup></td></tr><tr><td align="center" valign="middle" >P (W)</td><td align="center" valign="middle" >14.8</td><td align="center" valign="middle" >25 &#215; 10<sup>−3</sup></td><td align="center" valign="middle" >0.3 &#215; 10<sup>−9</sup></td></tr><tr><td align="center" valign="middle" >Pτ (aJ)</td><td align="center" valign="middle" >7.55</td><td align="center" valign="middle" >44</td><td align="center" valign="middle" >3</td></tr></tbody></table></table-wrap><p>for X-rays, not just for visible and infrared (IR) lights. 2) The voltage responsivity of the capacitor decreases with increasing frequency ν (or decreases with decreasing period τ) of the electromagnetic (EM) waves. Indeed, the voltage responsivity π<sub>V</sub> of the capacitor we used in our investigation is significantly smaller than that previously determined by illumination with visible and IR light of the same capacitor. 3) The formalism related to Pτ and the law of conservation of energy enables us to unveil the relationship between the average power P of the X-rays and the effective dose delivered on an organic sample. The effective dose is an important operating parameter in standard medical imaging machines employing X-rays.</p><p>In addition to these fundamental results, we achieve a significant practical result: the procedure we used in our investigation enables us to measure the average power P of the X-rays generated in two machines, one originally designed for usage in medical imaging, and the other designed for X-ray diffraction of powders. The power P is of the order of few mW for the standard X-ray medical imaging machine, and W for the X-ray diffractometer. Our procedure paves the ground for designing an X-ray power-meter, a tool presently missing in the market of X-ray characterization tools.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This work was supported by the JMU Department of Physics and Astronomy, and the JMU Center for Materials Science. The authors thank A. Banu and S. Pendleton for fruitful discussions and for technical support at the Madison Accelerator Laboratory (JMU). The authors also thank B. A. Reisner and X. Hu (JMU, Chemistry and Biochemistry) for technical support, and gratefully acknowledge the National Science Foundation (NSF) for instrumentation support (DMR-0315345) enabling the X-Ray measurement performed with the X-ray diffractometer (PXRD) (X’pert PANalytical). Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the NSF.</p></sec><sec id="s7"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s8"><title>Cite this paper</title><p>Hassan, S.I. and Scarel, G. (2020) The Total Energy in the Interaction of X-Ray Photons with Capacitors. World Journal of Condensed Matter Physics, 10, 159-177. https://doi.org/10.4236/wjcmp.2020.104010</p></sec><sec id="s9"><title>Appendix</title><p>To justify the use of Pτ and the law of conservation of energy, we exploit the total differential dE of the energy transferred from the EM waves to the capacitor on an area A<sub>cs</sub> with diameter D corresponding to the cross-section of the EM beam:</p><p>d E = q d Δ V + Δ V d q − Σ d Δ T − Δ T d Σ , (A1)</p><p>where q = σA<sub>cs</sub> is charge, σ = q/A<sub>cs</sub> is surface charge density, and Σ is entropy. The thermal component of Equation (A1) is preceeded by a negative sign to signify that part of the energy transferred to the capacitor as electrical energy is thermally dissipated. Hypothesizing that the capacitance C = q Δ V enables us to separate the terms containing q and ΔV, thus reducing Equation (A1) to:</p><p>d E = C Δ V d Δ V + q C d q − Σ d Δ T (A2)</p><p>where we assume dΣ to be negligible. In a generalized grand-canonical ensemble [<xref ref-type="bibr" rid="scirp.104030-ref19">19</xref>], the entropy Σ is the Legendre transformation of Σ<sub>0</sub>, the entropy of the canonical ensemble, such that Σ = Σ 0 − k B β q Δ V [<xref ref-type="bibr" rid="scirp.104030-ref19">19</xref>], where k<sub>B</sub> = 1.38 &#215; 10<sup>−23</sup> J/K is Boltzmann’s constant, and β = 1/k<sub>B</sub>T. Therefore:</p><p>d E = C Δ V d Δ V + q C d q − Σ 0 d Δ T + k B β q Δ V d Δ T (A3)</p><p>Assuming k<sub>B</sub>βqΔV to give just a slight correction to Σ<sub>0</sub>, dE is further reduced to:</p><p>d E ≈ C Δ V d Δ V + q C d q − Σ 0 d Δ T (A4)</p><p>At the start of the illumination of the capacitor with visible or IR light, the energy conserved in each instant of time t is E(t) = P(t)Δt. Here P(t) is the exponential function that describes the rise in time of the EM wave’s power with a time constant τ<sub>P</sub> such that:</p><p>P ( t ) = − P 0 exp ( − t / τ p ) + P ssli (A5)</p><p>where P<sub>0</sub> ≈ P<sub>ssli</sub>≈ P and P is the average power in the steady state illumination (ssli) regime. In the ssli the energy conserved is E<sub>c</sub> = PΔt. To obtain E(t) and E<sub>c</sub>, we integrate the variables ΔV, E, q, and ΔT between their minima and maxima values:</p><p>∫ Δ E min Δ E MAX d E = C ∫ Δ V min Δ V MAX Δ V d Δ V + 1 C ∫ q min q MAX q d q − Σ 0 ∫ Δ T min Δ T MAX d Δ T (A6)</p><p>We redefine the variables such that their minima are set at zero in their respective units and their maxima correspond to the values of the variables at an arbitrary instant of time t such that ΔV<sub>MAX</sub> = ΔV(t), ΔE<sub>MAX</sub> = ΔE(t), q<sub>MAX</sub> = q(t), and ΔT<sub>MAX</sub> = ΔT(t). The integration leads to:</p><p>E ( t ) = P ( t ) Δ t = 1 2 C Δ V ( t ) 2 + 1 2 q ( t ) 2 C − Σ 0 Δ T ( t ) (A7a)</p><p>In particular, in the ssli the integration gives:</p><p>E c = P Δ t = 1 2 C Δ V 2 + 1 2 q ssli 2 C − Σ 0 Δ T (A7b)</p><p>where q<sub>ssli</sub> is the surface charge in the ssli on the area A<sub>cs</sub>. Simulations show that Equation (A7) is effective if Δt= τ, the period of the EM wave.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.104030-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Chandler, D. (1987) Introduction to Modern Statistical Mechanics. Oxford University Press Inc., Oxford.</mixed-citation></ref><ref id="scirp.104030-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Zhao, D., Fabiano, S., Berggren, M. and Crispin, X. (2017) Ionic Thermoelectric Gating Organic Transistors. Nature Communications, 8, Article No. 14214. https://doi.org/10.1038/ncomms14214</mixed-citation></ref><ref id="scirp.104030-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">(2020) Radiation Exposure from Medical Exams and Procedures. Health Physics Society Specialists in Radiation Safety, 1-4.</mixed-citation></ref><ref id="scirp.104030-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Heimann, P., Fritz, D., Krzywinsky, J., Moeller, S., Nordlund, D., Reid, A., Stefan, P., Walter, P. and Welch, J. (2019) Laser Power Meters as Portable X-Ray Power Monitors. X-Ray Free-Electron Lasers: Advances in Source Development and Instrumentation V, 11038, Article ID: 110380R. https://doi.org/10.1117/12.2526119</mixed-citation></ref><ref id="scirp.104030-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Tanaka, T., Kato, M., Saito, N., Owada, S., Tono, K., Yabashi, M. and Ishikawa, T. (2017) Compact Bolometric Radiometer for Free-Electron Lasers in a Wavelength Range from Extreme-Ultraviolet to X-Rays. Optics Letters, 42, 4776-4779. https://doi.org/10.1364/OL.42.004776</mixed-citation></ref><ref id="scirp.104030-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Adam, Y., Kim, J.J., Lou, S., Zhao, Y., Xie, M.E., Brinks, D., Wu, H., Mostajo-Radji, M.A., Kheifets, S., Parot, V., Chettih, S., Williams, K.J., Gmeiner, B., Farhi, S.L., Madisen, L., Buchanan, E.K., Kinsella, I., Zhou, D., Paninski, L., Harvey, C.D., Zeng, H., Arlotta, P., Campbell, R.E. and Cohen, A.E. (2019) Voltage Imaging and Optogenetics Reveal Behavior-Dependent Changes in Hippocampal Dynamics. Nature, 569, 413-417. https://doi.org/10.1038/s41586-019-1166-7</mixed-citation></ref><ref id="scirp.104030-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Kim, M.H., Vickers, E. and Gersdorff, H.V. (2012) Patch-Clamp Capacitance Measurements and Ca2+ Imaging at Single Nerve Terminals in Retinal Slices. Journal of Visual Experiments, 59, e3345. https://doi.org/10.3791/3345</mixed-citation></ref><ref id="scirp.104030-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Vedantham, H.K., Callingham, J.R., Shimwell, T.W., Tasse, C., Pope, B.J., Bedell, M., Snellen, I., Best, P., Hardcastle, M.J., Haverkorn, M., Mechev, A., O’Sullivan, S.P., R&amp;#246;ttgering, H.J.A. and White, G.J. (2020) Coherent Radio Emission from a Quiescent Red Dwarf Indicative of Star-Planet Interaction. Nature Astronomy, 4, 577-583. https://doi.org/10.1038/s41550-020-1011-9</mixed-citation></ref><ref id="scirp.104030-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Pickens, K.T. and Scarel, G. (2020) Estimation of the Power of the Anomalous Microwave Emission. World Journal of Condensed Matter Physics, 10, 105-117. https://doi.org/10.4236/wjcmp.2020.103007</mixed-citation></ref><ref id="scirp.104030-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Yan, W., Frühling, C., Golovin, G., Heden, D., Luo, J., Zhang, P., Zhao, B., Zhang, J., Liu, C., Chen, M., Chen, S., Banerjee, S. and Umstadter, D. (2017) High-Order Multiphoton Thomson Scattering. Nature Photonics, 11, 514-520. https://doi.org/10.1038/nphoton.2017.100</mixed-citation></ref><ref id="scirp.104030-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Scarel, G. (2019) The Role of Pτ in the Photothermoelectric Effect and in Photoredox Catalysis Reactions. World Journal of Condensed Matter Physics, 9, 91-101. https://doi.org/10.4236/wjcmp.2019.94007</mixed-citation></ref><ref id="scirp.104030-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Scarel, G. (2019) Quantum and Non-Quantum Formulation of Eye’s Adaptation to Light’s Intensity Increments. World Journal of Condensed Matter Physics, 9, 62-74.https://doi.org/10.4236/wjcmp.2019.93005</mixed-citation></ref><ref id="scirp.104030-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Scarel, G. and Stevens, E.C. (2019) The Effect of Infrared Light’s Power on the Infrared Spectra of Thin Films. World Journal of Condensed Matter Physics, 9, 1-21. https://doi.org/10.4236/wjcmp.2019.91001</mixed-citation></ref><ref id="scirp.104030-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Gordon, A.L. and Scarel, G. (2018) Interaction in the Steady State between Electromagnetic Waves and Matter. World Journal of Condensed Matter Physics, 8, 171-184. https://doi.org/10.4236/wjcmp.2018.84012</mixed-citation></ref><ref id="scirp.104030-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Boone, D.E., Jackson, C.H., Swecker, A.T., Hergenrather, J.S., Wenger, K.S., Kokhan, O., Terzi&amp;#263;, B., Melnikov, I., Ivanov, I.N., Stevens, E.C. and Scarel, G. (2018) Probing the Wave Nature of Light-Matter Interaction. World Journal of Condensed Matter Physics, 8, 62-89. https://doi.org/10.4236/wjcmp.2018.82005</mixed-citation></ref><ref id="scirp.104030-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Rivera, N., Wong, L.J., Joannopoulos, J.D., Solja&amp;#269;i&amp;#263;, M. and Kaminer, I. (2019) Light Emission Based on Nanophotonic Vacuum Forces. Nature Physics, 15, 1284-1289. https://doi.org/10.1038/s41567-019-0672-8</mixed-citation></ref><ref id="scirp.104030-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Ji, Z., Liu, G., Addison, Z., Liu, W., Yu, P., Gao, H., Liu, Z., Rappe, A.M., Kane, C.L., Mele, E.J. and Agarwal, R. (2019) Spatially Dispersive Circular Photogalvanic Effect in a Weyl Semimetal. Nature Materials, 18, 955-962. https://doi.org/10.1038/s41563-019-0421-5</mixed-citation></ref><ref id="scirp.104030-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Osterhoudt, G.B., Diebel, L.K., Gray, M.J., Yang, X., Stanco, J., Huang, X., Shen, B., Ni, N., Moll, P.J., Ran, Y. and Burch, K.S. (2019) Colossal Mid-Infrared Bulk Photovoltaic Effect in a Type-I Weyl Semimetal. Nature Materials, 18, 471-475. https://doi.org/10.1038/s41563-019-0297-4</mixed-citation></ref><ref id="scirp.104030-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Field, G.D. and Rieke, F. (2002) Nonlinear Signal Transfer from Mouse Rods to Bipolar Cells and Implications for Visual Sensitivity. Neuron, 34, 773-785. https://doi.org/10.1016/S0896-6273(02)00700-6</mixed-citation></ref></ref-list></back></article>