<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AID</journal-id><journal-title-group><journal-title>Advances in Infectious Diseases</journal-title></journal-title-group><issn pub-type="epub">2164-2648</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/aid.2020.105019</article-id><article-id pub-id-type="publisher-id">AID-103898</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Evaluation of Two Serological Screening Kits for Hepatitis C Virus Infection at the Regional Blood Transfusion Center of Ouagadougou, Burkina Faso
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Arzouma</surname><given-names>Paul Yooda</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Koumpingnin</surname><given-names>Nebie</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Juliette</surname><given-names>Tranchot-Diallo</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Salam</surname><given-names>Sawadogo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Moutanou</surname><given-names>Modeste Judes Zeye</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Abdoul-Guaniyi</surname><given-names>Sawadogo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Abdou</surname><given-names>Azaque Zoure</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Dinanibè</surname><given-names>Kambire</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Serge</surname><given-names>Sawadogo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Seimbou</surname><given-names>Zalla</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yetema</surname><given-names>Dieudonné Yonli</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Abibou</surname><given-names>Simpore</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Sibiri</surname><given-names>Nana</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ashmed</surname><given-names>Chèickh Bachirou Nana</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Anita</surname><given-names>Pierrette Siritie</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Fiffou</surname><given-names>Yougbare</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Sonia</surname><given-names>Ba-Nébhane Sontie</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Alain</surname><given-names>Konseybo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jean</surname><given-names>Etienne Koanda</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Oury</surname><given-names>Sanou</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jacques</surname><given-names>Simpore</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>National Blood Transfusion Center (NBTC), Ouagadougou, Burkina Faso</addr-line></aff><aff id="aff3"><addr-line>Laboratory of Molecular Biology and Genetics (LABIOGENE), Joseph KI-ZERBO University, Ouagadougou, Burkina Faso</addr-line></aff><aff id="aff2"><addr-line>Training and Research Unit/Science and Technology (TRU/ST), Nazi-BONI University, Bobo-Dioulasso, Burkina Faso</addr-line></aff><aff id="aff4"><addr-line>Research Institute in Health Sciences (IRSS/CNRST), Ouagadougou, Burkina Faso</addr-line></aff><pub-date pub-type="epub"><day>16</day><month>10</month><year>2020</year></pub-date><volume>10</volume><issue>05</issue><fpage>216</fpage><lpage>227</lpage><history><date date-type="received"><day>22,</day>	<month>September</month>	<year>2020</year></date><date date-type="rev-recd"><day>30,</day>	<month>October</month>	<year>2020</year>	</date><date date-type="accepted"><day>2,</day>	<month>November</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Introduction: In Burkina Faso, screening for hepatitis C virus in blood donations is made using sensitive ELISA (Enzyme Linked Immuno Sorbent Assay) type kits. However, no confirmation of the positive results obtained with these kits is made before their notification to the blood donors due to the high costs of the confirmation kits of immunoblots type. 
  Objective: Evaluate two rapid kits against one immunoblot kit in order to determine the most efficiency which will be proposed as an alternative for the confirmation of ELISA tests in the socio-economic context of Burkina Faso. 
  Material and Methods: The study was carried out using a panel of 72 sera, of which 22 were positive for anti-HCV antibodies and 50 were negative. The sera were tested using the Monolisa
  &amp;#174; HCV Ag-Ab ULTRA kit and confirmed with the DECISCAN HCV Plus kit. The panel was then tested with the SD BIOLINE HCV kit and the HCV TRI-DOT kit and the results obtained were evaluated against those of the DECISCAN HCV Plus kit used as “gold standard”. 
  Results: Compared to the DECISCAN HCV Plus kit, the HCV TRI-DOT kit exhibited a sensitivity and specificity of 100% and the SD BIOLINE HCV kit a sensitivity of 86.36% and a specificity of 100%. 
  Conclusion: Based on the results recorded by the HCV TRI-DOT kit, it would be best suited to the sero-epidemiological context of blood donors from the National Blood Transfusion Center and could be proposed as an alternative for confirmation of ELISA tests.
 
</p></abstract><kwd-group><kwd>HCV</kwd><kwd> Sensitivity</kwd><kwd> Specificity</kwd><kwd> Burkina Faso</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>2. Material and Methods</title><sec id="s1_1"><title>2.1. Type and Scope of the Study</title><p>This was a cross-sectional validation study of two serological screening tests for HCV which took place at RBTC/O between the period from January to March 2012.</p><p>The RBTC/O is one of the eight operational structures of the NBTC located in different regions of the country. The role of the NBTC is to coordinate the country’s transfusion activities and the RBTC’s missions are to collect, qualify and distribute labile blood products (LBP) to all health structures in their coverage areas. Since the operationalization of these RBTC, which began in 2005, the blood safety policy has continuously improved with the application of measures such as the medical selection of donors, the recruitment of unpaid voluntary donors from low-risk populations, the loyalty of blood donors, and the use of fourth-generation serological tests for the biological qualification of donations.</p></sec><sec id="s1_2"><title>2.2. Constitution of the Panel</title><p>The samples included in the panel are serums from unpaid volunteer blood donors of both sexes aged from 18 to 60 years. Samples were collected on dry tubes from donors during blood donation, centrifuged at 4000 g for 5 minutes and collected serum were tested using the Monolisa&#174; HCV Ag-Ab ULTRA kit (Bio-Rad, Marnes-la-Coquette-France) according to the strategy for the biological qualification of donations adopted at the NBTC. Then, samples were aliquoted and stored at −80˚C for the serotheque. We randomly selected 90 samples including 40 anti-HCV antibody positive and 50 negative samples, which we re-tested at DECISCAN HCV Plus kit (Bio-Rad, Marnes-la-Coquette-France) for confirmation. All 50 anti-HCV antibody negative serum to Monolisa&#174; HCV Ag-Ab ULTRA kit, were confirmed negative by DECISCAN HCV Plus kit. On the other hand, of the 40 anti-HCV antibody sero positive for Monolisa&#174; HCV Ag-Ab ULTRA kit, 22 were confirmed positive, nine were negative and nine others were unsuccessful (<xref ref-type="fig" rid="fig1">Figure 1</xref>). We then retained the 50 negative samples and the 22 DECISCAN HCV Plus positive samples (i.e. 72 samples) for our validation panel for the two rapid test kits.</p></sec><sec id="s1_3"><title>2.3. Carrying Out the Various Analyzes</title><sec id="s1_3_1"><title>2.3.1. The DECISCAN HCV plus Kit</title><p>The DECISCAN HCV Plus kit (Bio-Rad, France) is an immunoblot validation test. It is a unit membrane test using an enzyme-immunoassay technique allowing the individualization of antibodies associated with HCV infection in human serum or plasma.</p><p>The DECISCAN HCV Plus kit contains strips where the antigens (core, NS3, NS4 and NS5) are previously fixed. For analysis, the serum is first incubated with the strip. If the anti-HCV antibodies are present, they bind to the antigens fixed to the solid phase. A first wash is performed to remove excess serum and unbound antibodies. Then, alkaline phosphatase labeled anti-human IgG antibodies are added, which in turn will bind to the specific antibodies retained on the solid phase. A second wash is carried out to remove the unbound enzyme conjugate and finally the antigen-antibody complex is revealed by addition of the substrate.</p></sec><sec id="s1_3_2"><title>2.3.2. SD BIOLINE HCV Kit</title><p>SD BIOLINE HCV kit (SD STANDARD DIAGNOSTICS, INC, Kyonggi-do Korea) a fourth-generation rapid test using an immunochromatographic principle for the qualitative detection of HCV specific antibodies in serum, plasma, or whole blood. The kit contains strips in which the recombinant antigens (Core, NS3, NS4, and NS5) are previously fixed (<xref ref-type="table" rid="table1">Table 1</xref>). The analytical procedure consists of depositing 10 μL of serum in the deposit zone, then adding four drops of diluent. The sample migrates on the solid phase to the patient window phase (T) and forms an antigen-antibody complex as manifested by line visible.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Characteristics of the kits evaluated according to the manufacturer</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Characteristics of the kits</th><th align="center" valign="middle" >SD BIOLINE HCV kit</th><th align="center" valign="middle" >HCV TRI-DOT kit</th></tr></thead><tr><td align="center" valign="middle" >Maker</td><td align="center" valign="middle" >Standard Diagnostics, Inc.</td><td align="center" valign="middle" >J. Mitra &amp; Co. Pvt. Ltd</td></tr><tr><td align="center" valign="middle" >Principle</td><td align="center" valign="middle" >Immunochromatography</td><td align="center" valign="middle" >Immunofiltration</td></tr><tr><td align="center" valign="middle" >Antigens</td><td align="center" valign="middle" >(Core, NS3, NS4, NS5)</td><td align="center" valign="middle" >(Core, NS3, NS4, NS5)</td></tr><tr><td align="center" valign="middle" >Recommended biological sample</td><td align="center" valign="middle" >Serum, plasma, Whole blood</td><td align="center" valign="middle" >Serum, plasma</td></tr><tr><td align="center" valign="middle" >Storage temperature</td><td align="center" valign="middle" >1˚C - 30˚C</td><td align="center" valign="middle" >2˚C - 8˚C</td></tr><tr><td align="center" valign="middle" >Reading</td><td align="center" valign="middle" >Visual</td><td align="center" valign="middle" >Visual</td></tr><tr><td align="center" valign="middle" >Sensitivity</td><td align="center" valign="middle" >100%</td><td align="center" valign="middle" >100%</td></tr><tr><td align="center" valign="middle" >Specificity</td><td align="center" valign="middle" >99.4%</td><td align="center" valign="middle" >99.8%</td></tr></tbody></table></table-wrap><p>The results are read 15 minutes after the deposit according to the instructions provided by the manufacturer. The test is labeled with the letters C and T representing respectively the control band and the positive band of the test. The test is only valid if the control strip appears.</p></sec><sec id="s1_3_3"><title>2.3.3. HCV TRI-DOT Kit</title><p>HCV TRI-DOT kit (J. Mitra &amp; Co. Pvt. Ltd., New Delhi-INDIA) is a fourth-generation rapid visual test using the principle of immuno-filtration for the qualitative detection of HCV specific antibodies in serum or plasma. The kit contains a unique combination of modified antigens from the core, NS3, and the NS4 and NS5 regions of HCV (<xref ref-type="table" rid="table1">Table 1</xref>). These antigens are immobilized on a porous immunofiltration membrane, which includes two test points, T1 and T2, and an additional point for quality control. When the sample infiltrates through the membrane, anti-HCV antibodies present, bind to antigens immobilized on the absorbent pad. Then a conjugate is added which binds to the Fc portion of HCV-specific immunoglobulin G to give a distinct purple-pink separate dot in the test area. A color will appear at the control point after the patient’s serum has been added regardless of the color that appears in the two test points (T1 and T2), confirming that the reagents are working properly and that the procedure has been followed. The test run time is 5 min.</p></sec></sec><sec id="s1_4"><title>2.4. Statistical Analyzes</title><p>The proportion of positive and negative results obtained was calculated for each test submitted for evaluation. The results were compared to those of DECISCAN HCV Plus kit in a 2 &#215; 2 contingency table. Then, we calculated the sensitivity (true positives/true positives + false negatives) and specificity (true negatives/true negatives + false positive) for each test. We also determined the Youden index (sensitivity + specificity − 1) to better establish the level of efficiency of the performance of the two tests evaluated compared to the gold standard.</p></sec><sec id="s1_5"><title>2.5. Ethical Considerations</title><p>The informed consent of blood donors was systematically obtained before any blood donation by signing the pre-donation medical interview sheet. The study received the approval of the internal scientific review committee of the NBTC. The anonymity and confidentiality of blood donors were respected.</p></sec></sec><sec id="s2"><title>3. Results</title><sec id="s2_1"><title>3.1. Socio-Demographic Characteristics of Blood Donors Includ in the Study</title><p>A total of 72 blood donors were included in this study. The age of the blood donors varied between 18 and 55 years with an average of 29.54 +/− 8.81 years. The majority of blood donors were male (69.44%) and were first-time donors (94.44%) (<xref ref-type="table" rid="table2">Table 2</xref>).</p></sec><sec id="s2_2"><title>3.2. Serological Results Obtained with SD-BIOLINE HCV Kit and HCV TRI-DOT Kit</title><p>All the 50 anti-HCV antibody negative to DECISCAN HCV Plus kit included in the study were tested negative with the SD BIOLINE HCV kit and with the HCV TRI-DOT kit. Similarly, all 22 serums HCV antibody positive to DECISCAN HCV Plus kit were tested positive to HCV TRI-DOT kit (<xref ref-type="table" rid="table3">Table 3</xref>). In contrast with SD BIOLINE HCV kit, 19 serums were positive and 03 negatives. No doubtful or indeterminate results were detected by these two tests.</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Socio-demographic characteristics of blood donors</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Characteristics</th><th align="center" valign="middle" >Number (n = 72)</th><th align="center" valign="middle" >Proportion (%)</th></tr></thead><tr><td align="center" valign="middle" >Gender</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Male</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >69.44</td></tr><tr><td align="center" valign="middle" >Female</td><td align="center" valign="middle" >22</td><td align="center" valign="middle" >30.56</td></tr><tr><td align="center" valign="middle" >Age groups</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >&lt;20 ans</td><td align="center" valign="middle" >13</td><td align="center" valign="middle" >18.05</td></tr><tr><td align="center" valign="middle" >20 - 29 ans</td><td align="center" valign="middle" >35</td><td align="center" valign="middle" >48.61</td></tr><tr><td align="center" valign="middle" >30 - 39 ans</td><td align="center" valign="middle" >9</td><td align="center" valign="middle" >12.50</td></tr><tr><td align="center" valign="middle" >40 - 49 ans</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >15.28</td></tr><tr><td align="center" valign="middle" >≥50 ans</td><td align="center" valign="middle" >4</td><td align="center" valign="middle" >5.56</td></tr><tr><td align="center" valign="middle" >Donors status</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >First time donors</td><td align="center" valign="middle" >68</td><td align="center" valign="middle" >94.44</td></tr><tr><td align="center" valign="middle" >Repeat donors</td><td align="center" valign="middle" >4</td><td align="center" valign="middle" >5.56</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Serological results obtained with SD BIOLINE HCV kit and HCV TRI-DOT kit</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="2"   rowspan="2"  ></th><th align="center" valign="middle" >DECISCAN HCV Plus</th></tr></thead><tr><td align="center" valign="middle" >HCV+ HCV−</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SD BIOLINE HCV</td><td align="center" valign="middle" >HCV+</td><td align="center" valign="middle" >19 00</td></tr><tr><td align="center" valign="middle" >HCV−</td><td align="center" valign="middle" >03 50</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >HCV TRI-DOT</td><td align="center" valign="middle" >HCV+</td><td align="center" valign="middle" >22 00</td></tr><tr><td align="center" valign="middle" >HCV−</td><td align="center" valign="middle" >00 50</td></tr></tbody></table></table-wrap></sec><sec id="s2_3"><title>3.3. Performance of SD B IOLINE HCV Kit and HCV TRI-DOT Kit</title><p>Compared to the gold standard, the SD BIOLINE HCV kit has a sensitivity of 86.36% and a specificity of 100%. The HCV TRI-DOT kit showed a sensitivity and specificity of 100%. <xref ref-type="table" rid="table4">Table 4</xref> gives the different intrinsic performances (sensitivity, specificity) and the levels of effectiveness (Youden index) of SD BIOLINE HCV kit and HCV TRI-DOT kit compared to the gold standard. <xref ref-type="fig" rid="fig2">Figure 2</xref> shows Receiver Operating Characteristics (ROC) curve comparing the performance of SD BIOLINE HCV and HCV TRI-DOT tests in blood donors</p></sec></sec><sec id="s3"><title>4. Discussion</title><p>Our work aimed to evaluate two serologic tests for HCV infection (SD BIOLINE HCV, HCV TRI-DOT) compared to the DECISCAN HCV Plus kit to propose an alternative and inexpensive algorithm for HCV serological screening in our socio-economic context. Both tests were evaluated using a panel of serums collected from blood donors in RBTC of Ouagadougou. We chose to evaluate these two tests because they are very easy to use, provide results in less than 30 min and are less expensive, especially in resources limited contexts. They do not require highly qualified laboratory technicians, or specific laboratory equipment [<xref ref-type="bibr" rid="scirp.103898-ref7">7</xref>]. In addition, these kits were already present in the list of tests marketed and used in Burkina Faso for HCV screening. But, immunoblot kits such as DECISCAN HCV PLUS use enzyme-immunoassay technics and require relatively expensive laboratory equipment, reagents and relatively long handling times.</p><p>The study showed that SD BIOLINE HCV kit and HCV TRI-DOT kit both have a specificity of 100% and sensitivities of 86.36% and 100% respectively (<xref ref-type="table" rid="table4">Table 4</xref>). As in our study, several other studies report that rapid screening tests for anti-HCV antibodies generally have good specificity (100%) but not all have good sensitivities [<xref ref-type="bibr" rid="scirp.103898-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref10">10</xref>]. The Youden index was 1 for the HCV TRI-DOT kit indicating a perfect detection capacity of both HCV positive and negative subjects. On the other hand, the Youden index SD BIOLINE HCV kit was 0.86 showing that about 14% of the samples were not properly detected (<xref ref-type="table" rid="table4">Table 4</xref>). These results are in agreement with several other studies that report that rapid tests for HCV are generally low in sensitivity in the African context. For example, an international multicenter study evaluating eight (8) rapid kits involving</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Performances of SD BIOLINE HCV and HCV TRI-DOT</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Kits</th><th align="center" valign="middle" >Sensitivity (%)</th><th align="center" valign="middle" >Specificity (%)</th><th align="center" valign="middle" >Youden Index</th></tr></thead><tr><td align="center" valign="middle" >HCV TRI-DOT</td><td align="center" valign="middle" >100% (95% CI)</td><td align="center" valign="middle" >100% (95% CI)</td><td align="center" valign="middle" >1</td></tr><tr><td align="center" valign="middle" >SD BIOLINE HCV</td><td align="center" valign="middle" >86.36% (95% CI)</td><td align="center" valign="middle" >100% (95% CI)</td><td align="center" valign="middle" >0.86</td></tr></tbody></table></table-wrap><p>51 blood transfusion centers in 17 African countries reported that the overall sensitivity of these tests was 63.7% with variations ranging from 43% to 100% [<xref ref-type="bibr" rid="scirp.103898-ref10">10</xref>]. Similarly, in Burkina Faso, three rapid kits evaluated using serums from RBTC/O blood donors had low sensitivities ranging from 33% to 47% [<xref ref-type="bibr" rid="scirp.103898-ref7">7</xref>]. These different results show that rapid tests have great variability in performance, especially in the African context, as shown in this study. This situation could be explained by multiple factors, in particular the genetic variability of the viral strains, the seroprevalence of the infection in the population, the conditions of transport and storage of the screening kits, which are likely to influence the sensitivity of the tests [<xref ref-type="bibr" rid="scirp.103898-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref12">12</xref>]. Indeed, HCV has six different genotypes with great genetic diversity. Thus, the ability of each test to detect the different genotypes circulating in each geographical locality depends strongly on the nature and types of antigens that make it up [<xref ref-type="bibr" rid="scirp.103898-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref9">9</xref>]. For this reason, the choice of commercial tests for a particular geographic area should always be preceded by adequate assessment with samples collected locally to determine the performance (sensitivity and specificity) of the test in this specific context, which may differ from those given by the manufacturer [<xref ref-type="bibr" rid="scirp.103898-ref7">7</xref>].</p><p>The poor performance of SD BIOLINE HCV kit (sensibility to 86.36% and index Youden 0.86) means that this test would lead to false negatives when used in the context of Burkina Faso. It therefore does not guaranteed optimal transfusion safety. Many donors would be screened false negative because of a lack of sensitivity, which would endanger the health of recipients. This test would be better indicated for the diagnosis of HCV infection in a clinical setting. The specificity of 100% obtained with SD BIOLINE HCV kit in our study is consistent with that given by the manufacturer and is similar to those found in other studies [<xref ref-type="bibr" rid="scirp.103898-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref9">9</xref>]. In contrast, the sensitivity of 86.36% obtained in the study is lower than that provided by the manufacturer (99.4%). Other authors, Laperche et al. (2013) and Ouedraogo et al. (2019) had also reported respectively in their studies of sensitivities of 72.2% and of 33.87%, significantly lower than those provided by the manufacturer (99.4%) [<xref ref-type="bibr" rid="scirp.103898-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.103898-ref10">10</xref>]. However, in a study conducted in India, the SD BIOLINE HCV kit had a sensitivity of 100% on a panel of serums from patients seen in a hepato-gastroenterology department and 97.4% on another panel of serums from blood donors [<xref ref-type="bibr" rid="scirp.103898-ref9">9</xref>]. These different results show that the performance of the tests can vary according to the nature of the population studied.</p><p>HCV TRI-DOT kit exhibits good sensitivity (100%) and good specificity (100%) (<xref ref-type="table" rid="table4">Table 4</xref>) concerning the serums collected locally in Burkina Faso. This performance means that both false negative and false positive results would be minimized by this test. It would ensure better transfusion safety and could be used as a second line alternative to immunoblot confirmatory tests for the confirmation of results obtained by ELISA kit in blood transfusion centers. Besides, its cost is relatively affordable and its use is less demanding in terms of technical platform compared to immunoblot kits validation. The sensitivity (100%) and specificity (100%) obtained by the HCV TRI-DOT kit were respectively in line with the manufacturer’s specifications with 100% and 99.8% respectively. Daniel et al. (2005) had also reported a good sensitivity of 99.3% and a good specificity of 99% of HCV TRI-DOT kit in a study evaluating this test compared to conventional ELISA kits [<xref ref-type="bibr" rid="scirp.103898-ref8">8</xref>]. In the same study, Daniel et al. (2005) have also shown that this test was less sensitive to certain genotypes circulating in India including genotypes 1 and 3 [<xref ref-type="bibr" rid="scirp.103898-ref8">8</xref>]. However, these authors admit, as shown in our study, that HCV TRI-DOT kit provides excellent performance and competes in terms of sensitivity with ELISA kits [<xref ref-type="bibr" rid="scirp.103898-ref8">8</xref>].</p><p>Given the results obtained, we proposed a serological screening algorithm adapted to the socioeconomic context of Burkina Faso (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The objective of this algorithm is to reduce as much as possible the use of confirmatory immunoblot tests while ensuring the reliability of the results. In terms of blood transfusion, the parameter sought is sensitivity because it guarantees the test's ability to detect the weakest positive samples. However, in order not to wrongly exclude donors from donating blood and also to return the results to blood donors who wish to know their serological status, it is advisable to confirm them by a test with good specificity. To do this, we have selected the HCV TRI-DOT kit with regard to its performance to offer an algorithm sequentially combining an</p><p>enzyme immunoassay (Monolisa&#174; HCV Ag-Ab ULTRA) as a first-line test, a rapid test (HCV TRI-DOT HCV) as a second-line and an immunoblot test (DECISCAN HCV Plus) to test any cases of discrepancies that may be encountered between the first two tests. In this case, any positive result on the first-line test (Monolisa&#174; HCV Ag-Ab ULTRA) and positive in the second test (HCV TRI-DOT) will be considered positive and the result will be declared positive to the donor and the donor will be excluded from donating blood. On the other hand, a positive result on the first-line test and negative for HCV TRI-DOT kit will be considered “indeterminate” and a control by a third immunoblot test is necessary to conclude.</p></sec><sec id="s4"><title>5. Conclusion</title><p>This study showed that not all commercial screening tests for HCV infection present the same diagnostic performance in the epidemiological context of Burkina Faso. This implies the imperative need to evaluate the tests before their use for optimal transfusion safety. Besides, our study made it possible to propose an alternative screening algorithm adapted to the socio-economic context of Burkina Faso. This algorithm combines a test capable of ensuring optimal transfusion safety with a high sensitivity to a second test to guarantee reliable results to donors with a specificity of 100%.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s6"><title>Cite this paper</title><p>Yooda, A.P., Nebie, K., Tranchot-Diallo, J., Sawadogo, S., Zeye, M.M.J., Sawadogo, A.-G., Zoure, A.A., Kambire, D., Sawadogo, S., Zalla, S., Yonli, Y.D., Simpore, A., Nana, S., Nana, A.C.B., Siritie, A.P., Yougbare, F., Sontie, S.B.-N., Konseybo, A., Koanda, J.E., Sanou, O. and Simpore, J. (2020) Evaluation of Two Serological Screening Kits for Hepatitis C Virus Infection at the Regional Blood Transfusion Center of Ouagadougou, Burkina Faso. Advances in Infectious Diseases, 10, 216-227. https://doi.org/10.4236/aid.2020.105019</p></sec></body><back><ref-list><title>References</title><ref id="scirp.103898-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">OMS. (2010) Dépistage des infections transmissibles par le sang. Recommandations.</mixed-citation></ref><ref id="scirp.103898-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Tagny, C.T., Mbanya, D., Murphy, E.L., Lefrère, J.-J. and Laperche, S. (2014) Screening for Hepatitis C Virus Infection in a High Prevalence Country by an Antigen/Antibody Combination Assay versus a Rapid Test. Journal of Virological Methods, 199, 119-123. https://doi.org/10.1016/j.jviromet.2014.01.002</mixed-citation></ref><ref id="scirp.103898-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Laperche, S., Le Marrec, N., Girault, A., Bouchardeau, F., Servant-Delmas, A., Maniez-Montreuil, M., Gallian, P., Levayer, T., Morel, P. and Simon, N. (2005) Simultaneous Detection of Hepatitis C Virus (HCV) Core Antigen and Anti-HCV Antibodies Improves the Early Detection of HCV Infection. Journal of Clinical Microbiology, 43, 3877-3883. https://doi.org/10.1128/JCM.43.8.3877-3883.2005</mixed-citation></ref><ref id="scirp.103898-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Vo, M.T., Bruhn, R., Kaidarova, Z., Custer, B.S., Murphy, E.L. and Bloch, E.M. (2016) A Retrospective Analysis of False-Positive Infectious Screening Results in Blood Donors. Transfusion, 56, 457-465. https://doi.org/10.1111/trf.13381</mixed-citation></ref><ref id="scirp.103898-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Meda, N., Tuaillon, E., Kania, D., Tiendrebeogo, A., Pisoni, A., Zida, S., Bollore, K., Medah, I., Laureillard, D. and Moles, J.P. (2018) Hepatitis B and C Virus Seroprevalence, Burkina Faso: A Cross-Sectional Study. Bulletin of the World Health Organization, 96, 750. https://doi.org/10.2471/BLT.18.208603</mixed-citation></ref><ref id="scirp.103898-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yooda, A.P., Sawadogo, S., Soubeiga, S.T., Obiri-Yeboah, D., Nebie, K., Ouattara, A.K., Diarra, B., Simpore, A., Yonli, Y.D. and Sawadogo, A.-G. (2019) Residual Risk of HIV, HCV, and HBV Transmission by Blood Transfusion between 2015 and 2017 at the Regional Blood Transfusion Center of Ouagadougou, Burkina Faso. Journal of Blood Medicine, 10, 53. https://doi.org/10.2147/JBM.S189079</mixed-citation></ref><ref id="scirp.103898-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Ouedraogo, H.G., Ouandaogo, H.S., Zida, S., Compaoré, T.R., Sagna, T., Sawadogo, S., Kouanda, S., Traore, Y. and Barro, N. (2019) Evaluation of Three Commercialized Rapid Point-of-Care Tests for Detection of Anti-Hepatitis C Virus Antibodies in Burkina Faso. African Journal of Microbiology Research, 13, 710-715.</mixed-citation></ref><ref id="scirp.103898-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Daniel, H.D.J., Abraham, P., Raghuraman, S., Vivekanandan, P., Subramaniam, T. and Sridharan, G. (2005) Evaluation of a Rapid Assay as an Alternative to Conventional Enzyme Immunoassays for Detection of Hepatitis C Virus-Specific Antibodies. Journal of Clinical Microbiology, 43, 1977-1978. https://doi.org/10.1128/JCM.43.4.1977-1978.2005</mixed-citation></ref><ref id="scirp.103898-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Mane, A., Sacks, J., Sharma, S., Singh, H., Tejada-Strop, A., Kamili, S., Kacholia, K., Gautam, R., Thakar, M. and Gupta, R.S. (2019) Evaluation of Five Rapid Diagnostic Tests for Detection of Antibodies to Hepatitis C Virus (HCV): A Step towards Scale-Up of HCV Screening Efforts in India. PLoS ONE, 14, e0210556. https://doi.org/10.1371/journal.pone.0210556</mixed-citation></ref><ref id="scirp.103898-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Laperche, S. (2013) Multinational Assessment of Blood-Borne Virus Testing and Transfusion Safety on the African Continent. Transfusion, 53, 816-826.https://doi.org/10.1111/j.1537-2995.2012.03797.x</mixed-citation></ref><ref id="scirp.103898-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Ndjoyi-Mbiguino, A. and Bélec, L. (2005) &amp;#201;valuation de trousses de dépistage de l’infection à VIH au Gabon. Cahiers d'études et de recherches francophones/Santé, 15, 23-29.</mixed-citation></ref><ref id="scirp.103898-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Delwart, E., Slikas, E., Stramer, S.L., Kamel, H., Kessler, D., Krysztof, D., Tobler, L.H., Carrick, D.M., Steele, W. and Todd, D. (2012) Genetic Diversity of Recently Acquired and Prevalent HIV, Hepatitis B Virus, and Hepatitis C Virus Infections in US Blood Donors. Journal of Infectious Diseases, 205, 875-885.https://doi.org/10.1093/infdis/jir862</mixed-citation></ref></ref-list></back></article>