<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">NS</journal-id><journal-title-group><journal-title>Natural Science</journal-title></journal-title-group><issn pub-type="epub">2150-4091</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ns.2020.125022</article-id><article-id pub-id-type="publisher-id">NS-100146</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Medicine&amp;Healthcare</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Potential Power of the Pyramidal Structure II
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Osamu</surname><given-names>Takagi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Masamichi</surname><given-names>Sakamoto</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hideo</surname><given-names>Yoichi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kimiko</surname><given-names>Kawano</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mikio</surname><given-names>Yamamoto</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>International Research Institute (IRI), Chiba, Japan</addr-line></aff><aff id="aff2"><addr-line>Aquavision Academy, Chiba, Japan</addr-line></aff><pub-date pub-type="epub"><day>28</day><month>04</month><year>2020</year></pub-date><volume>12</volume><issue>05</issue><fpage>248</fpage><lpage>272</lpage><history><date date-type="received"><day>7,</day>	<month>April</month>	<year>2020</year></date><date date-type="rev-recd"><day>10,</day>	<month>May</month>	<year>2020</year>	</date><date date-type="accepted"><day>13,</day>	<month>May</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Research on “pyramid power” began in the late 1930s. To date, many documents on “pyramid power” have been published. We have been conducting scientific research on the unexplained “power” of a pyramidal structure (PS) since October 2007. The research focuses on the detection of a non-contact effect of the unexplained “power” of the PS on biosensors (i.e., edible cucumber sections of Cucumis sativus “white spine type”) placed at the top of the PS. In this paper, in particular, we compared the non-contact effect of upper and lower biosensors placed in two layers on the PS apex, and we analyzed the difference of the non-contact effect due to the difference in the layers. The magnitude of the non-contact effect was represented by the calibrated psi index Ψ(E-CAL) calculated from gas concentrations emitted from the biosensors. A method to determine the presence or absence of the non-contact effect by analyzing the gas concentrations was developed by the International Research Institute (IRI). Ψ(E-CAL), which represents the magnitude of the non-contact effect, was the average value of the respective non-contact effect of the upper and lower biosensors stacked in two layers on the PS apex. We conducted the analysis on the assumption that the non-contact effect on the upper and lower biosensors might be different. Therefore, we considered that upper and lower biosensor calibration was required for Ψ(E-CAL), and we introduced a new calibrated psi index Ψ(E-CAL)Layer. Scientifically rigorous experiments to date have detected Ψ(E-CAL) with statistical significance and have demonstrated potential power of the PS (p = 6.0 &#215; 10&lt;sup&gt;-3&lt;/sup&gt;; Welch’s t-test, two-tails, the following p values are also the Welch’s t-test values). Based on data demonstrating the potential power of the PS, we analyzed the non-contact effects on the upper and lower biosensors of the PS apex. We obtained a surprising result that the non-contact effect on the upper biosensors (farther from the PS) was larger than that on the lower biosensors (closer to the PS) (p = 4.0 &#215; 10&lt;sup&gt;-7&lt;/sup&gt;). This suggested that the characteristic of the potential power of the PS, which is considered to exist near the PS apex, is distinctive. We also found that the non-contact effect due to the potential power of the PS varies with the season, and is large in summer and small in winter. In our discussion, we proposed a model that could theoretically explain the experimental results that the non-contact effect on the upper biosensors at the PS apex is larger than the lower biosensors. In proposing this model, we assumed that there were two different types of potential power at the PS apex and that the biosensors had two different gas-generating reactions. In a simulation using the model, the experimental results were well approximated in which the non-contact effect on the biosensors differs depending on the difference between the upper and lower layers. The results of this paper are the world’s first to prove aspects of the “pyramid power” through scientifically rigorous experiments and analysis. These results will become a new field of science in the future, and their broad applications are expected.
 
</p></abstract><kwd-group><kwd>Pyramid</kwd><kwd> Potential Power</kwd><kwd> Meditation</kwd><kwd> Unconsciousness</kwd><kwd> Non-Contact Effect</kwd><kwd> Delay</kwd><kwd> Biosensor</kwd><kwd> Cucumis sativus</kwd><kwd> Gas</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>In the late 1930s, the Frenchman Antoine Bovis found a naturally mummified small animal in the Great Pyramid of Giza. This was the beginning of research on a so-called “pyramid power”. To date, many documents on the “pyramid power” have been published [1-18]. Among them, some made a scale model of the large pyramid of Giza and conducted experiments [1-4,8,12,18], one book tried to elucidate unexplained functions of the pyramid using mathematical formulas [<xref ref-type="bibr" rid="scirp.100146-ref17">17</xref>], and another acquired patent information [<xref ref-type="bibr" rid="scirp.100146-ref15">15</xref>]. However, scientific research papers published in academic journals are rare [19,20]. On the other hand, it is true that there are documents that deny the existence of the “pyramid power” as pseudo-science [21-24]. The grounds for denying the “pyramid power” are that experiments did not provide sufficiently statistical significance, and that there was no scientific theory to understand the phenomenon.</p><p>We have been studying unexplained “power” of a pyramidal structure (PS) using a biosensor (edible cucumber sections: Cucumis sativus “white spine type”) since October 2007. Scientifically rigorous experiments and analyzes demonstrated the existence of an unexplained “power” of the PS (an unexplained function of the PS) with statistically very high significance. The results of our research on the PS have been published as seven original papers [25-31], two research summaries [32,33], and one chapter in a book [<xref ref-type="bibr" rid="scirp.100146-ref34">34</xref>].</p><p>In experiments using the PS, we performed two types of experiments with different conditions as follows.</p><p>Experiment 1: An experiment conducted in a state where the PS and a human (a test subject) were related.</p><p>Experiment 2: An experiment conducted in a state where the PS and a human (a test subject) were not related.</p><p>Experiment 1 is the experiment that was conducted from several hours before meditating to 20 days after meditation when the test subject meditated (Hemi-Sync<sup>&#174;</sup> [<xref ref-type="bibr" rid="scirp.100146-ref35">35</xref>]) within the PS. Experiment 1 suggested the existence of two unexplained energies of human origin (force types I and II) [31,33]. From Experiment 1, the following two results were obtained.</p><p>1) When the PS and a human unconsciousness (force type I) were related.</p><p>A change in the non-contact effect, which seems to correspond to an unconscious change, was detected during the transition from a sleep state to an awake state of a human (the test subject) 6 km or more away (1% significance) [30,33].</p><p>2) When the PS and the effect of a human (the test subject) meditating in the PS (force type II) were related.</p><p>The non-contact effect with delay was detected over a dozen days after meditation (p = 3.5 &#215; 10<sup>−6</sup>; Welch’s t-test, two-tails, the following p values are also the Welch’s t-test values) [26,27,32,33]. The characteristics of the non-contact effect with delay could be very well approximated by theoretical curves calculated from a model of transient response phenomena in control theory [26,32,33].</p><p>As a result of Experiment 2, the non-contact effect on the biosensors placed at the PS apex was detected with statistical significance (p = 6.0 &#215; 10<sup>−3</sup>), demonstrating the existence of the potential power of the PS [<xref ref-type="bibr" rid="scirp.100146-ref31">31</xref>]. It was also found that the non-contact effect due to the potential power of the PS varies with the season, and is large in summer and small in winter.</p><p>Until now, the non-contact effect on the biosensors has been expressed as the calibrated psi index Ψ<sub>(</sub><sub>E-CAL)</sub> [31,34]. Ψ<sub>(</sub><sub>E-CAL)</sub> is the average value of the non-contact effect values Ψ<sub>1(E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub> of the upper and lower biosensors placed on the PS apex in two layers. In this paper, based on the experimental data obtained in Experiment 2, the non-contact effect of each of the upper and lower biosensors placed at the PS apex was compared. Therefore, we considered that upper and lower sensor calibration is required for Ψ<sub>(</sub><sub>E-CAL)</sub>, and we introduced a new calibrated psi index Ψ<sub>(E-CAL)Layer</sub>. The reason that the introduction of Ψ<sub>(</sub><sub>E-CAL)Layer</sub> became possible was that sufficient experimental data were obtained (n = 468), and analysis that separated the upper and lower layers became possible. A surprising result was obtained that the non-contact effect on the upper biosensors (farther from the PS) was larger than that of the lower biosensors (closer to the PS) (p = 4.0 &#215; 10<sup>−7</sup>). In other words, it became clear that the potential power of the PS has different effects on the upper and lower biosensors. In order to understand this phenomenon quantitatively, we improved the model proposed in our previous paper [<xref ref-type="bibr" rid="scirp.100146-ref31">31</xref>] and proposed a new model considering the distribution characteristics of potential power of the PS. In a simulation using this new model, we were able to approximate the experimental results in which the non-contact effect differs between the upper and lower layers. The discovery of the potential power of the PS obtained through scientifically rigorous experiments and analysis is the world’s first research to demonstrate the “pyramid power”. This result will become a new field of science in the future, and broad applications are expected.</p></sec><sec id="s2"><title>2. EXPERIMENT</title><sec id="s2_1"><title>2.1. Pyramidal Structure (PS)</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref>(a) showed the PS used in the present experiment. The PS was a square pyramid with a height of 107 cm, a ridgeline length of 170 cm and a base length of 188 cm. The angle (tilt angle) between the bottom and the side of the PS was 49.1˚. The base of the PS was raised by four tripods to a height of 73 cm from the floor. The frame of the PS was made of four aluminum pipes (2 cm diameter, 0.36 cm thick pipe wall). Each side had a Sierpinski triangle pattern and it consisted of aluminum plates (0.3 mm thick). At the top of the PS, a Faraday cage for electrostatic shielding of the biosensors was placed. A calibration control point was set up 8 m away from the PS [25,34]. The PS is a simple and static structure which does not have any mechanically movable parts nor does it have a supply of known energy.</p></sec><sec id="s2_2"><title>2.2. Detection of Unexplained “Power” (Non-Contact Effect) of the PS</title><p>To demonstrate the “pyramid power” of the PS, we examined the presence or absence of the non- contact effect on the biosensors (cucumber fruit sections). To detect the non-contact effect, the gas concentration generated by the gas production reaction of the cucumber sections was measured. Samples were prepared according to a simultaneous calibration technique (SCAT) [<xref ref-type="bibr" rid="scirp.100146-ref36">36</xref>] to prepare homogeneous biosensors (<xref ref-type="fig" rid="fig1">Figure 1</xref>(b)). The detection method the non-contact effect by analyzing the gas concentrations released from the biosensors was researched and developed by the International Research Institute (IRI),</p><p>and we used it previously to successfully detect a healer’s non-contact effect and a wave like bio-field around the healer [37-39].</p><p>G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub>, the experimental samples of Pair 1 and Pair 2 in <xref ref-type="fig" rid="fig1">Figure 1</xref>(b), were placed in covered Petri dishes at the PS apex in two layers. And G<sub>C</sub><sub>1</sub> and G<sub>C</sub><sub>2</sub>, the control samples of Pair 1 and Pair 2, and G<sub>E</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub>, G<sub>C</sub><sub>3</sub> and G<sub>C</sub><sub>4</sub>, the control samples of Pair 3 and Pair 4 were similarly placed at the calibration control point 8 m away from the PS, also in two layers. For G<sub>E</sub> and G<sub>C</sub>, the larger subscript number was the upper layer (<xref ref-type="fig" rid="fig1">Figure 1</xref>(c)). The biosensors were kept in place for 30 minutes. G<sub>E</sub> and G<sub>C</sub> were the same cut section, but the direction of the cutting was different. G<sub>E</sub> was cut in the same direction as the cucumber growth axis, while G<sub>C</sub> was cut in the opposite direction. Previous experiments demonstrated that the gas concentration varies depending on the direction of the cut section, and G<sub>E</sub> &lt; G<sub>C</sub> [<xref ref-type="bibr" rid="scirp.100146-ref29">29</xref>]. The center point of the bottom of the Petri dish of G<sub>E</sub><sub>1</sub> placed at the PS apex coincided with the extension of the center of the four aluminum pipes near the PS apex (<xref ref-type="fig" rid="fig1">Figure 1</xref>(c)). After setting the covered Petri dish there for 30 minutes, the Petri dish was removed from the PS and its lid was taken off. Each Petri dish was then placed in a closed container with a volume of 2.2 liters and the containers were placed in a temperature-controlled room to be stored side by side on shelves for each pair. Storage time was 24 h-48 h. After storage, the gas concentrations released from the cucumber sections were measured. Gas detection tubes (Ethyl acetate detector tube 141 L: Gastech, Japan) and a gas sampling pump (GV-100: Gastech, Japan) were used to measure the gas concentrations.</p></sec><sec id="s2_3"><title>2.3. Non-Contact Effect Magnitude Psi Index Ψ</title><p>To examine the non-contact effect on the biosensors, we introduced a psi index Ψ that quantifies the magnitude of the non-contact effect [31,34]. Ψ was calculated by Equation (1) using the measured gas concentrations. We considered that the unexplained “power” of the PS has a very small effect on changes in gas concentrations. Then, the non-contact effect may be buried in noise, making its detection difficult. The reason was that the gas generation reaction of the biosensors was considered to react sensitively due to factors such as differences between individual cucumbers and environmental conditions. Therefore, in order to minimize the noise displacement, a paired sample method (<xref ref-type="fig" rid="fig1">Figure 1</xref>(b)) was used in which G<sub>E</sub> and G<sub>C</sub> were compared as a pair. Ψ is 100 times the natural logarithm of the ratio calculated for the gas concentrations of each pair. The relationship between the J value we used previously and Ψ was Ψ = 100 J [<xref ref-type="bibr" rid="scirp.100146-ref40">40</xref>].</p><p>Ψ 1 = 100 ln ( G E 1 / G C 1 ) , Ψ 2 = 100 ln ( G E 2 / G C 2 ) , Ψ 3 = 100 ln ( G E 3 / G C 3 ) , Ψ 4 = 100 ln ( G E 4 / G C 4 ) . (1)</p><p>In Equation (1), G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub> and G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> were gas concentrations (ppm) measured from the biosensors shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>(b). Ψ<sub>1</sub>-Ψ<sub>4</sub> were the psi index values before calibration. G<sub>E</sub><sub>3</sub>, G<sub>C</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub>, and G<sub>C</sub><sub>4</sub> were biosensors placed at the calibration control point, and G<sub>E</sub> and G<sub>C</sub> differed only in the direction of the cut section. Therefore, it was considered that the influence of the difference in the direction of the cut section of cucumber was detected from Ψ<sub>3</sub> and Ψ<sub>4</sub>. From Ψ<sub>1</sub> and Ψ<sub>2</sub>, it was considered that two effects were detected, the effect of the difference in the cutting direction and the effect of the difference in the placement (the PS apex and the calibration control point). The results of subtracting the average values of Ψ<sub>3</sub> and Ψ<sub>4</sub> from Ψ<sub>1</sub> and Ψ<sub>2</sub> are Ψ<sub>1(</sub><sub>E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub>. Ψ<sub>1(</sub><sub>E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub> calibrated against environmental factors such as temperature, humidity, atmospheric pressure, geomagnetism, etc., and also calibrated against the cutting direction. Therefore, the calibrated psi indices, Ψ<sub>1(</sub><sub>E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub>, were considered to be the results (non-contact effect by the PS) reflecting only the effect of the unexplained “power” of the PS.</p><p>Ψ 1 ( E-CAL ) = Ψ 1 − ( Ψ 3 + Ψ 4 ) / 2 , Ψ 2 ( E-CAL ) = Ψ 2 − ( Ψ 3 + Ψ 4 ) / 2 , Ψ 3 ( C-CAL ) = Ψ 3 − ( Ψ 3 + Ψ 4 ) / 2 , Ψ 4 ( C-CAL ) = Ψ 4 − ( Ψ 3 + Ψ 4 ) / 2 . (2)</p><p>Finally, the calibrated psi index Ψ<sub>(</sub><sub>E-CAL)</sub>, the non-contact effect on the biosensors, was obtained from the average of the lower and upper calibrated psi indices Ψ<sub>1(E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub>.</p><p>Ψ ( E-CAL ) = ( Ψ 1 ( E-CAL ) + Ψ 2 ( E-CAL ) ) / 2 . (3)</p><p>The purpose of this paper was to analyze the difference of the non-contact effect on the upper and lower biosensors placed in two layers. Therefore, Ψ<sub>(</sub><sub>E-CAL)Layer</sub> was introduced, which allows calibration of the two stacked upper and lower layers.</p><p>Ψ 1 ( E-CAL ) Layer1 = Ψ 1 ( E-CAL ) − Ψ 3 ( C-CAL ) = Ψ 1 − Ψ 3 , Ψ 2 ( E-CAL ) Layer2 = Ψ 2 ( E-CAL ) − Ψ 4 ( C-CAL ) = Ψ 2 − Ψ 4 . (4)</p><p>Here, Ψ<sub>(</sub><sub>E-CAL)LayerAve</sub>, which is the average value of Ψ<sub>1(E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub>, coincided with Ψ<sub>(E-CAL)</sub>.</p><p>Ψ ( E-CAL ) LayerAve = ( Ψ 1 ( E-CAL ) Layer1 + Ψ 2 ( E-CAL ) Layer2 ) / 2 = ( Ψ 1 ( E-CAL ) + Ψ 2 ( E-CAL ) ) / 2 = Ψ ( E-CAL ) . (5)</p></sec></sec><sec id="s3"><title>3. EXPERIMENTAL AND ANALYTICAL RESULTS</title><p>In this paper, in order to verify the potential power of the PS, the data obtained in Experiment 2 described in “1. Introduction” were analyzed (n = 468). Experiment 2 was not only an “experiment performed without the test subject in the PS”, but also an experiment that met two conditions (Conditions 1 and 2). The reason why these conditions were added is described below. If Conditions 1 and 2 were not satisfied, we had found that the effect of the PS on the biosensors was not the effect of the potential power of the PS but the effect of “the state in which the PS and the test subject were related” [26,27,30,32,33].</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows the average gas concentration released from the biosensors (n = 468). In the figure, we observed no significant difference between the average gas concentrations of all the biosensors G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub> and G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> (p = 0.088). However, the following possibilities 1)-4) were considered. 1) At the PS apex, the gas concentration of the biosensors placed in the upper layer (G<sub>E</sub><sub>2</sub>) was higher than that in the lower layer (G<sub>E</sub><sub>1</sub>). 2) Conversely, at the calibration control point, the gas concentrations of the biosensors placed in the upper layer (G<sub>E</sub><sub>4</sub>, G<sub>C</sub><sub>2</sub>, G<sub>C</sub><sub>4</sub>) were lower than those in the lower layer (G<sub>E</sub><sub>3</sub>, G<sub>C</sub><sub>1</sub>, G<sub>C</sub><sub>3</sub>). 3) When the experimental sample G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub> and the control sample G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> were compared, the difference in gas concentration due to the layer was larger in G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub> than in G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub>. 4) In the experimental samples, the</p><p>difference in gas concentration due to the difference in layer was reversed between G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> at the PS apex and G<sub>E</sub><sub>3</sub> and G<sub>E</sub><sub>4</sub> at the calibration control point. 5) In the control samples, G<sub>C</sub><sub>1</sub>, G<sub>C</sub><sub>2</sub>, G<sub>C</sub><sub>3</sub> and G<sub>C</sub><sub>4</sub> at the calibration control point showed almost equal changes in gas concentration due to the difference in the layer. From 1)-5), it was considered that the biosensors G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> at the PS apex showed an abnormal reaction as compared with the biosensors at the calibration control point.</p><p><xref ref-type="fig" rid="fig3">Figure 3</xref> shows a scatter plot (n = 468) to determine whether there was a correlation between the gas concentrations emitted from the biosensors stacked in two layers, upper and lower. It was concluded that the correlation coefficient of gas concentration between the two layered biosensors was about 0.7 at both the PS apex and the calibration control point, indicating a positive correlation.</p><p><xref ref-type="fig" rid="fig4">Figure 4</xref>(a) shows the sum of the gas concentrations of the upper and lower biosensors in two layers.</p><p>From an analysis of variance (ANOVA), p = 0.45 and no significant difference was observed. However, different gas concentrations (G<sub>E</sub> &lt; G<sub>C</sub>) were obtained depending on the direction of the axis of the cut section of the cucumbers [<xref ref-type="bibr" rid="scirp.100146-ref29">29</xref>]. The experimental samples (G<sub>E</sub><sub>1</sub> + G<sub>E</sub><sub>2</sub>) and (G<sub>E</sub><sub>3</sub> + G<sub>E</sub><sub>4</sub>) were almost the same, but the control samples tended to be in the order (G<sub>C</sub><sub>1</sub> + G<sub>C</sub><sub>2</sub>) &lt; (G<sub>C</sub><sub>3</sub> + G<sub>C</sub><sub>4</sub>). The following was considered as the reason for this order despite being placed at the calibration control point and having the same axial direction for cutting. In other words, we considered that the effect of the PS apex did not appear directly on the biosensors G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> placed at the PS apex, rather it appeared on the biosensor pair G<sub>C</sub><sub>1</sub> and G<sub>C</sub><sub>2</sub>. A similar phenomenon has been seen in other experimental reports [39,41]. <xref ref-type="fig" rid="fig4">Figure 4</xref>(b) shows the gas concentration ratio calculated by dividing the upper gas concentration by the lower one, taking the logarithm and multiplying by 100. This expression was similar to the psi index of Equation (1). For ANOVA, p = 5.2 &#215; 10<sup>−6</sup>, and a significant difference was recognized. Tukey’s test showed that 100ln(G<sub>E</sub><sub>2</sub>/G<sub>E</sub><sub>1</sub>) was abnormally large compared to the others. <xref ref-type="fig" rid="fig4">Figure 4</xref> revealed the following findings. No significant difference was found in the sum of the gas concentrations of the biosensors placed on the upper and lower layers, but the ratio of the gas concentrations indicated that 100ln(G<sub>E</sub><sub>2</sub>/G<sub>E</sub><sub>1</sub>) was abnormally large. Therefore, it was considered that one or both G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> placed at the PS apex exhibited an abnormal change different from that when placed at the calibration control point.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows the scatter diagram (n = 468) to determine whether or not there is a correlation between the gas concentrations of the biosensors of the pair shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>(b). <xref ref-type="fig" rid="fig5">Figure 5</xref>(a) and <xref ref-type="fig" rid="fig5">Figure 5</xref>(b) include the results of G<sub>E</sub><sub>1</sub> or G<sub>E</sub><sub>2</sub> placed at the PS apex. <xref ref-type="fig" rid="fig5">Figure 5</xref>(c) and <xref ref-type="fig" rid="fig5">Figure 5</xref>(d) include the results of the biosensors placed at the calibration control point. All the correlation coefficients showed a positive correlation of about 0.8. Therefore, it was found that the correlation coefficient between the paired biosensors was larger than the correlation coefficient between the two layered biosensors in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref>(a) shows the average (n = 468) of the sum of the gas concentrations emitted from the</p><p>biosensors of the pair. For ANOVA, p = 0.57, and no significant difference was observed. Although there was no significant difference, when (G<sub>E</sub><sub>3</sub> + G<sub>C</sub><sub>3</sub>) and (G<sub>E</sub><sub>4</sub> + G<sub>C</sub><sub>4</sub>) placed at the calibration control point were compared, there was a tendency that (G<sub>E</sub><sub>3</sub> + G<sub>C</sub><sub>3</sub>) &gt; (G<sub>E</sub><sub>4</sub> + G<sub>C</sub><sub>4</sub>). The difference between (G<sub>E</sub><sub>3</sub> + G<sub>C</sub><sub>3</sub>) and (G<sub>E</sub><sub>4</sub> + G<sub>C</sub><sub>4</sub>) was only the difference between the respective upper and lower layers. Therefore, at the calibration reference point, it was suggested that the gas concentration of the lower biosensors was higher than that of the upper biosensors. Atmospheric pressure was considered as one of the causes. On the other hand, when (G<sub>E</sub><sub>1</sub> + G<sub>C</sub><sub>1</sub>) and (G<sub>E</sub><sub>2</sub> + G<sub>C</sub><sub>2</sub>) including the biosensors G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> placed at the PS apex were compared, the opposite tendency was shown. Similar to the results of <xref ref-type="fig" rid="fig2">Figure 2</xref> and <xref ref-type="fig" rid="fig4">Figure 4</xref>(b), the following was found from the results of <xref ref-type="fig" rid="fig6">Figure 6</xref>(a). G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> placed at the PS apex were abnormal compared to G<sub>E</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub> and G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> at the calibration control point. However, it was not possible to determine</p><p>whether the abnormality was with G<sub>E</sub><sub>1</sub> or G<sub>E</sub><sub>2</sub>, or both. Therefore, we tried to identify them separately by calculating the psi index Ψ<sub>1</sub>-Ψ<sub>4</sub> (<xref ref-type="fig" rid="fig6">Figure 6</xref>(b); the vertical axis is the magnitude of the psi index, and the horizontal axis is the psi index Ψ<sub>1</sub>-Ψ<sub>4</sub> before the calibration calculation by Equation (1)). For ANOVA, a significant difference was obtained for Ψ<sub>1</sub>-Ψ<sub>4</sub> (p = 9.3 &#215; 10<sup>−6</sup>). Among Ψ<sub>1</sub>-Ψ<sub>4 </sub>values, only Ψ<sub>2</sub> was positive and the others were negative. There was no significant difference between Ψ<sub>1</sub>, Ψ<sub>3</sub> and Ψ<sub>4</sub>. Therefore, Ψ<sub>2</sub> was considered to indicate an abnormal value. Since G<sub>E</sub><sub>2</sub> was included in the formula of Ψ<sub>2</sub>, we concluded that G<sub>E</sub><sub>2</sub> placed at the PS apex showed an abnormal value different from other biosensors. However, there was no significant difference between Ψ<sub>1</sub>, Ψ<sub>3</sub> and Ψ<sub>4</sub>, but it seemed that there was a difference between Ψ<sub>3</sub> and Ψ<sub>4</sub>. The cause was thought to be the result of the difference due to the layer between the pairs, as pointed out in the explanation of <xref ref-type="fig" rid="fig6">Figure 6</xref>(a).</p><p><xref ref-type="fig" rid="fig7">Figure 7</xref>(a) and <xref ref-type="fig" rid="fig7">Figure 7</xref>(b) show the moving average (window size is 180 days) of psi index Ψ<sub>1</sub>-Ψ<sub>4</sub>. The horizontal axis indicates the dates which are values from 1 to 366 obtained by starting at 1 and counting from January 1 of each year in which the experiment was conducted. The dates analyzed in this paper were obtained from experiments between July 2010 and September 2017. Using the same experimental data, we have already published one paper demonstrating the potential power of the PS [<xref ref-type="bibr" rid="scirp.100146-ref31">31</xref>]. In addition, papers on the unexplained functions of the PS [26,27,30] and papers on the characteristics of the biosensors [28,29] were presented from the results of experiments conducted during the same period. From the results of the moving averages of Ψ<sub>1</sub> and Ψ<sub>2</sub> (<xref ref-type="fig" rid="fig7">Figure 7</xref>(a)), we found that Ψ<sub>1</sub> &lt; Ψ<sub>2</sub> throughout the year, with the psi index increasing in summer and decreasing in winter. Summer was the period when the daytime was more than 12 hours and therefore from the day of the spring equinox to the day of the autumn equinox. When not a leap year, the former was March 20, and the value on the horizontal axis, 81. Similarly,</p><p>the latter was September 23, and the value on the horizontal axis, 267. Winter was the period when the daytime was less than 12 hours. The numbers of summer data were n = 252 and for winter data, n = 216. In <xref ref-type="fig" rid="fig7">Figure 7</xref>(b), the moving averages of Ψ<sub>3</sub> and Ψ<sub>4</sub> were both negative values, which could be understood from the result of G<sub>E</sub> &lt; G<sub>C</sub> [<xref ref-type="bibr" rid="scirp.100146-ref29">29</xref>]. The moving averages of Ψ<sub>3</sub> and Ψ<sub>4 </sub>were considered to be almost constant throughout the year. In <xref ref-type="fig" rid="fig7">Figure 7</xref>(a), Ψ<sub>1</sub> &lt; Ψ<sub>2</sub> for the lower layer Ψ<sub>1</sub> and the upper layer Ψ<sub>2</sub>, whereas in <xref ref-type="fig" rid="fig7">Figure 7</xref>(b), Ψ<sub>3</sub> &gt; Ψ<sub>4</sub> for the lower layer Ψ<sub>3</sub> and the upper layer Ψ<sub>4</sub>. In other words, we found that the magnitude of the psi index showed the opposite tendency between <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) and <xref ref-type="fig" rid="fig7">Figure 7</xref>(b). Similar to the previous results, the results in <xref ref-type="fig" rid="fig7">Figure 7</xref> also showed that the PS apex is a space that gives a unique effect (non-contact effect) to the biosensors compared to the calibration control point. Based on the results of the calibration control point, we found that Ψ<sub>1</sub> tended to decrease in winter and Ψ<sub>2</sub> tended to increase in summer.</p><p><xref ref-type="fig" rid="fig8">Figure 8</xref>(a) shows the scatter plot for Ψ<sub>1</sub> and Ψ<sub>2</sub>, and <xref ref-type="fig" rid="fig8">Figure 8</xref>(b) shows the scatter plot for Ψ<sub>3</sub> and Ψ<sub>4</sub>. It was found that both <xref ref-type="fig" rid="fig8">Figure 8</xref>(a) and <xref ref-type="fig" rid="fig8">Figure 8</xref>(b) had a positive correlation. As seen in <xref ref-type="fig" rid="fig5">Figure 5</xref>, the correlation between the gas concentrations of the pairs was about 0.8 in all cases, and the distribution was similar. In contrast, the following was found from the scatter plot of Ψ calculated from the ratio of the gas concentrations of the pair. The distributions of Ψ<sub>1</sub> and Ψ<sub>2</sub> that included the gas concentration at the PS apex and the distributions of Ψ<sub>3</sub> and Ψ<sub>4</sub> that included the gas concentration at the calibration control point were significantly different. The results in <xref ref-type="fig" rid="fig8">Figure 8</xref> also revealed that the PS apex was a space that showed an abnormal response to the biosensors compared to the calibration control point.</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> shows the difference in the non-contact effect due to the difference in layers for the biosensors</p><p>placed at the PS apex (n = 468). Above, <xref ref-type="fig" rid="fig6">Figure 6</xref>(b) and <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) suggested that the magnitude of the non-contact effect on the biosensors placed at the PS apex differs between the upper and lower layers. <xref ref-type="fig" rid="fig9">Figure 9</xref> shows in two ways the non-contact effect on the upper and lower biosensors located at the PS apex; that is, Ψ<sub>(</sub><sub>E-CAL)</sub> and Ψ<sub>(E-CAL)Layer</sub> which can calibrate the difference between layers. The black circles show the average value of Ψ<sub>1(</sub><sub>E-CAL)</sub> and Ψ<sub>2(E-CAL)</sub> in Equation (2) (p = 2.5 &#215; 10<sup>−5</sup>). The red squares show the average value of psi index which was calibrated for the difference in the layers in Equation (4)., Ψ<sub>1(E-CAL)Layer1</sub> = Ψ<sub>1</sub>-Ψ<sub>3</sub> and Ψ<sub>2(E-CAL)Layer2</sub> = Ψ<sub>2</sub>-Ψ<sub>4</sub> (p = 4.0 &#215; 10<sup>−7</sup>). It was found that the Ψ<sub>(</sub><sub>E-CAL)Layer</sub>, which calibrated the layer difference, had a smaller p-value than Ψ<sub>(E-CAL)</sub>. From these results, we concluded that it was necessary to use the Ψ<sub>(</sub><sub>E-CAL)Layer</sub> that calibrated the difference between layers when analyzing the difference between the upper and lower layers of the non-contact effect on the biosensors placed at the PS apex.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>0(a) shows the moving average (window size is 180 days) of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub>, Ψ<sub>2(E-CAL)Layer2</sub> and their average Ψ<sub>(E-CAL)LayerAve</sub>. According to <xref ref-type="fig" rid="fig9">Figure 9</xref>, for the average value, Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> &lt; Ψ<sub>2(E-CAL)Layer2</sub>. And from <xref ref-type="fig" rid="fig1">Figure 1</xref>0(a), the tendency of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> &lt; Ψ<sub>2(E-CAL)Layer2</sub> was seen throughout the year. At the PS apex, the non-contact effect on the upper biosensors was larger than on the lower biosensors. The Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub> tended to increase in summer and decrease in winter. <xref ref-type="fig" rid="fig1">Figure 1</xref>0(b) shows the scatter diagram of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> versus Ψ<sub>2(E-CAL)Layer2</sub>. The correlation coefficient was 0.87, indicating a strong correlation.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>1 shows the summer and winter data for Ψ<sub>1</sub>-Ψ<sub>4</sub> and Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub>, Ψ<sub>2(E-CAL)Layer2</sub>. Earlier, <xref ref-type="fig" rid="fig6">Figure 6</xref>(b) showed the annual average of Ψ<sub>1</sub>-Ψ<sub>4</sub>, while <xref ref-type="fig" rid="fig1">Figure 1</xref>1(a) shows the average of summer and winter values of Ψ<sub>1</sub>-Ψ<sub>4</sub>. The number of data was n = 252 in summer (orange squares) and n = 216 in winter (black squares). Compared to the difference between summer and winter of Ψ<sub>3</sub> and Ψ<sub>4</sub> calculated only with the biosensors placed at the calibration control point, it was found that the difference between summer and winter of Ψ<sub>1</sub> and Ψ<sub>2</sub> including G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> placed at the PS apex was larger. This result was expected</p><p>from <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) and <xref ref-type="fig" rid="fig7">Figure 7</xref>(b). Although the reason is not clear, there was a tendency that Ψ<sub>3</sub> &gt; Ψ<sub>4</sub> at the calibration control point. <xref ref-type="fig" rid="fig1">Figure 1</xref>1(b) shows the summer and winter data of Ψ<sub>1(</sub><sub>E-CAL)Layer1 </sub>and Ψ<sub>2(E-CAL)Layer2</sub> with respect to the results of <xref ref-type="fig" rid="fig9">Figure 9</xref>. It turned out that summer and winter behaviors were the consequence of almost parallel movement.</p></sec><sec id="s4"><title>4. Discussion</title><sec id="s4_1"><title>4.1. Moving Average of the Ψ<sub>(</sub><sub>E-CAL)</sub> and Proposal of “Model 1”</title><p>In our previous paper [<xref ref-type="bibr" rid="scirp.100146-ref31">31</xref>], we conducted the demonstration of the potential power of the PS under the condition that “the PS and a human (the test subject) were not related”. As a result, the average value of the Ψ<sub>(E-CAL)</sub>, which indicates the magnitude of the non-contact effect, became a positive value in summer, demonstrating the potential power of the PS (1% significance). It was also found that the moving average of the Ψ<sub>(</sub><sub>E-CAL)</sub> changed seasonally. We introduced one theoretical model that can explain the seasonal change of the moving average of the Ψ<sub>(</sub><sub>E-CAL)</sub> (“Model 1”) [<xref ref-type="bibr" rid="scirp.100146-ref31">31</xref>]. The introduction process of “Model 1” is shown in 1) to 3) below.</p><p>1) Data analysis revealed that the moving average of Ψ<sub>(</sub><sub>E-CAL)</sub> was large in summer and small in winter.</p><p>2) “Model 1” was introduced to explain the seasonal change of the moving average of the Ψ<sub>(</sub><sub>E-CAL)</sub> (<xref ref-type="fig" rid="fig1">Figure 1</xref>2). The characteristics and assumptions of “Model 1” were as follows (i)-(iv).</p><p>(i) There are two types of potential powers (potential power 1 (P<sub>1</sub>) and potential power 2 (P<sub>2</sub>)) near the PS apex.</p><p>(ii) The biosensors G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> at the PS apex are affected by the potential powers P<sub>1</sub> and P<sub>2</sub>.</p><p>(iii) There are at least two types of biosensor gas generation reactions (α reaction and β reaction).</p><p>(iv) In “Model 1”, α<sub>E</sub> and β<sub>E</sub> are the average gas concentrations generated from the experimental sample (G<sub>E</sub>) by α and β reactions. The α<sub>C</sub> and β<sub>C</sub> are the average gas concentrations generated from the control sample (G<sub>C</sub>) by α and β reactions. Further, α<sub>E</sub> &lt; α<sub>C</sub> and β<sub>E</sub> &lt; β<sub>C</sub> are satisfied. The reason is that the gas concentration varies depending on the axial direction of the cucumber section [<xref ref-type="bibr" rid="scirp.100146-ref29">29</xref>]. To facilitate understanding, α<sub>E</sub> = β<sub>E</sub> and α<sub>C</sub> = β<sub>C</sub>.</p><p>3) The relationships between the potential power of the PS and the gas production reaction were assumed as follows. “In winter, the potential power P<sub>1</sub> suppresses gas generation due to the α reaction and the gas concentration decreases by G(P<sub>1</sub>). As a result, α<sub>E</sub> of G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> becomes α<sub>E</sub><sub>(</sub><sub>winter)</sub>. Throughout the year, the potential power P<sub>2</sub> facilitates gas generation due to the β reaction and the gas concentration increases by G(P<sub>2</sub>). As a result, β<sub>E</sub> of G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> becomes β<sub>E</sub><sub>(</sub><sub>year)</sub>.”</p><p>The introduction process of 1)-3) made it possible to qualitatively understand the moving average of the Ψ<sub>(</sub><sub>E-CAL)</sub>. From Equation (5), Ψ<sub>(</sub><sub>E-CAL)</sub> = Ψ<sub>(E-CAL)LayerAve</sub>. Therefore, the moving average of Ψ<sub>(</sub><sub>E-CAL)</sub> matches the moving average of Ψ<sub>(E-CAL)LayerAve</sub> (<xref ref-type="fig" rid="fig1">Figure 1</xref>0(a)). Thus, it was found that the change of the moving average of Ψ<sub>(</sub><sub>E-CAL)LayerAve</sub> can be understood by the PS potential powers P<sub>1</sub>, P<sub>2</sub> and the gas generation reactions α, β. The Ψ<sub>(</sub><sub>E-CAL)LayerAve</sub> is the average of Ψ<sub>1(E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub> that calibrate the difference between the lower and upper layers. Therefore, like Ψ<sub>(</sub><sub>E-CAL)LayerAve</sub>, we thought that the moving average of</p><p>Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub> can also be explained by the PS potential powers P<sub>1</sub>, P<sub>2</sub> and gas generation reactions α, β.</p></sec><sec id="s4_2"><title>4.2. Moving Average of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub>, and Proposal of “Model 2”</title><p>As a result of data analysis, we found that Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> &lt; Ψ<sub>2(E-CAL)Layer2</sub>. The surprising result (p = 4.0 &#215; 10<sup>−7</sup>) was obtained that the non-contact effect on the biosensors in the upper layer was larger than that in the lower layer at the PS apex (<xref ref-type="fig" rid="fig9">Figure 9</xref>). The reason was considered to be the difference between the upper and lower environments, for example, the difference in brightness and the weight applied to the Petri dish. However, since Ψ<sub>(</sub><sub>E-CAL)Layer</sub> calibrated the difference between the upper and lower environments, the effects due to the environment should have been removed. In order to theoretically understand that the non-contact effect differs depending on the difference between the upper and lower layers, we propose a new “Model 2” that is a modification of “Model 1” (<xref ref-type="fig" rid="fig1">Figure 1</xref>3 and <xref ref-type="fig" rid="fig1">Figure 1</xref>4). In “Model 2”, the relationships between potential powers P<sub>1</sub>, P<sub>2</sub> of the PS and gas generation reactions α, β are the same as in “Model 1”. The P<sub>1</sub> is distributed near the PS apex in a region including G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub>. However, P<sub>2</sub> is assumed as in the following (i)-(ii).</p><p>(i) The P<sub>2</sub> spreads out in a cone starting from the PS apex (<xref ref-type="fig" rid="fig1">Figure 1</xref>3(a) and <xref ref-type="fig" rid="fig1">Figure 1</xref>3(b)).</p><p>(ii) The P<sub>2</sub> only affects biosensors inside the cone and does not affect biosensors outside the cone.</p><p>According to the assumptions (i)-(ii), P<sub>2</sub> affects only a small part of the surface of the four cucumber</p><p>sections in the Petri dish for the lower G<sub>E</sub><sub>1</sub> (<xref ref-type="fig" rid="fig1">Figure 1</xref>3(c): lower). On the other hand, it is considered that P<sub>2</sub> affects the entire surface of four cucumber sections in the Petri dish for G<sub>E</sub><sub>2</sub> in the upper layer (<xref ref-type="fig" rid="fig1">Figure 1</xref>3(c): upper).</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>4 shows changes in gas concentrations in summer (<xref ref-type="fig" rid="fig1">Figure 1</xref>4(a)) and winter (<xref ref-type="fig" rid="fig1">Figure 1</xref>4(b)) due to the potential powers P<sub>1</sub> and P<sub>2</sub>. In summer, P<sub>2</sub> increases the gas concentration of β<sub>E</sub> of G<sub>E</sub><sub>2</sub> by G(P<sub>2</sub>) (β<sub>E</sub> of G<sub>E</sub><sub>1</sub> does not change because P<sub>2</sub> has almost no effect on G<sub>E</sub><sub>1</sub>). In winter, the effect of P<sub>2</sub> is the same as in summer, but the gas concentration of α<sub>E</sub> of G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> decreases by G(P<sub>1</sub>) due to P<sub>1</sub>. The introduction of “Model 2” enables a qualitative understanding of the moving average of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub>.</p></sec><sec id="s4_3"><title>4.3. Quantification of α<sub>E</sub>, α<sub>C</sub>, β<sub>E</sub>, β<sub>C</sub> in “Model 2”</title><p><xref ref-type="fig" rid="fig2">Figure 2</xref> showed the average gas concentration (ppm) of each biosensors G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub>, G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub>, and the average value was (G<sub>E</sub><sub>1</sub>, G<sub>E</sub><sub>2</sub>, G<sub>E</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub>, G<sub>C</sub><sub>1</sub>, G<sub>C</sub><sub>2</sub>, G<sub>C</sub><sub>3</sub>, G<sub>C</sub><sub>4</sub>) = (344.7, 355.5, 356.2, 343.6, 358.5, 351.9, 359.7, 355.7). From these results, it was confirmed that G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> at the PS apex had abnormalities as compared with the biosensors G<sub>E</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub>, and G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> placed at the calibration control point. In order to clarify the abnormality of G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub>, we tried to find the model value of gas concentration based on the gas concentration at the calibration control point. The average gas concentration of the four biosensors G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> was 356.5 ppm and the average of G<sub>E</sub><sub>3</sub> and G<sub>E</sub><sub>4</sub> was 350 ppm. The average difference between the upper and lower layers was 5 ppm between G<sub>C</sub><sub>1</sub> and G<sub>C</sub><sub>4</sub> and 13 ppm between G<sub>E</sub><sub>3</sub> and G<sub>E</sub><sub>4</sub>. From these results, assuming that the biosensors at the PS apex had the same reaction as the calibration control point, we obtained the model value of the gas concentration as follows: (G<sub>E</sub><sub>1</sub>, G<sub>E</sub><sub>2</sub>, G<sub>E</sub><sub>3</sub>, G<sub>E</sub><sub>4</sub>, G<sub>C</sub><sub>1</sub>, G<sub>C</sub><sub>2</sub>, G<sub>C</sub><sub>3</sub>, G<sub>C</sub><sub>4</sub>) = (356.4, 343.4,</p><p>356.4, 343.4, 359.1, 353.8, 359.1, 353.8). These measured and model values are graphed in <xref ref-type="fig" rid="fig1">Figure 1</xref>5. When the measured and model values were compared, they almost matched at the calibration control point, but change at the PS apex had the opposite tendency. <xref ref-type="fig" rid="fig1">Figure 1</xref>6(a) and <xref ref-type="fig" rid="fig1">Figure 1</xref>6(b) shows the summer and winter gas concentrations of G<sub>E</sub><sub>1</sub>-G<sub>E</sub><sub>4</sub> and G<sub>C</sub><sub>1</sub>-G<sub>C</sub><sub>4</sub> based on this model value. As described above, since it was assumed that α<sub>E</sub> = β<sub>E</sub> and α<sub>C</sub> = β<sub>C</sub> in the gas generation reactions α and β, the values of α and β were half of the model values. As in <xref ref-type="fig" rid="fig1">Figure 1</xref>4, the gas concentration of β<sub>E</sub> of G<sub>E</sub><sub>2</sub> increased by G(P<sub>2</sub>) in summer. In winter, β<sub>E</sub> of G<sub>E</sub><sub>2</sub> increased by G(P<sub>2</sub>), and α<sub>E</sub> of G<sub>E</sub><sub>1</sub> and G<sub>E</sub><sub>2</sub> decreased by G(P<sub>1</sub>). Next, the magnitudes of G(P<sub>1</sub>) and G(P<sub>2</sub>) were estimated from the measured gas concentration.</p></sec><sec id="s4_4"><title>4.4. Quantification of G(P<sub>1</sub>) and G(P<sub>2</sub>) in “Model 2”</title><p>Here, we attempted to quantitatively estimate the magnitude of G(P<sub>1</sub>) and G(P<sub>2</sub>) in “Model 2” of <xref ref-type="fig" rid="fig1">Figure 1</xref>6. First, the magnitude of G(P<sub>2</sub>) was estimated from Ψ<sub>2</sub> in summer that was given in <xref ref-type="fig" rid="fig1">Figure 1</xref>4. From <xref ref-type="fig" rid="fig1">Figure 1</xref>4(a), summer Ψ<sub>2</sub> was expressed as follows.</p><p>Ψ 2 = 100 ln ( G E 2 / G C 2 ) = 100 ln ( ( α E + β E + G ( P 2 ) ) / ( α C + β C ) ) . (6)</p><p>From <xref ref-type="fig" rid="fig1">Figure 1</xref>6(a), α E + β E = 344 for G<sub>E</sub><sub>2</sub> and α C + β C = 354 for G<sub>C</sub><sub>2</sub>. From <xref ref-type="fig" rid="fig1">Figure 1</xref>1(a), the measured value of summer Ψ<sub>2</sub> was 4.047. From these results, we estimated that G(P<sub>2</sub>) = 25.6 ppm. Next, the magnitude of G(P<sub>1</sub>) was estimated in two ways, from winter Ψ<sub>1</sub> and winter Ψ<sub>2</sub> given in <xref ref-type="fig" rid="fig1">Figure 1</xref>4.</p><p>1) From winter Ψ<sub>1</sub></p><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref>4(b), Ψ<sub>1</sub> could be expressed as follows.</p><p>Ψ 1 = 100 ln ( G E 1 / G C 1 ) = 100 ln ( ( α E + β E − G ( P 1 ) ) / ( α C + β C ) ) . (7)</p><p>From <xref ref-type="fig" rid="fig1">Figure 1</xref>6(b), α E + β E = 356 for G<sub>E</sub><sub>1</sub>, and α C + β C = 360 for G<sub>C</sub><sub>1</sub>. From <xref ref-type="fig" rid="fig1">Figure 1</xref>1(a), the measured value of Ψ<sub>1</sub> in winter was −7.694. From these results, it was estimated that G(P<sub>1</sub>) = 23.6 ppm.</p><p>2) From winter Ψ<sub>2</sub></p><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref>4(b), Ψ<sub>2</sub> could be expressed as follows.</p><p>Ψ 2 = 100 ln ( G E 2 / G C 2 ) = 100 ln ( ( α E + β E − G ( P 1 ) + G ( P 2 ) ) / ( α C + β C ) ) . (8)</p><p>From <xref ref-type="fig" rid="fig1">Figure 1</xref>6(b), α E + β E = 344 for G<sub>E</sub><sub>2</sub> and α C + β C = 354 for G<sub>C</sub><sub>2</sub>. From <xref ref-type="fig" rid="fig1">Figure 1</xref>1(a), the measured value of Ψ<sub>2</sub> in winter was −1.924. By substituting G(P<sub>2</sub>) = 25.6 ppm obtained by Equation (6), it was estimated that G(P<sub>1</sub>) = 21.4 ppm.</p><p>The average value of G(P<sub>1</sub>) obtained by the two methods was 22.5 ppm. <xref ref-type="fig" rid="fig1">Figure 1</xref>7(a) and <xref ref-type="fig" rid="fig1">Figure 1</xref>7(b) show the respective summer and winter psi indices Ψ<sub>1</sub>-Ψ<sub>4</sub> calculated using the G(P<sub>1</sub>) and G(P<sub>2</sub>) estimates. Although there was some deviation, the results calculated from the measured values and the results obtained from “Model 2” were qualitatively consistent. The G(P<sub>2</sub>) was constant throughout the year, while G(P<sub>1</sub>) was an amount that appeared only in winter. Therefore, G(P<sub>1</sub>) was considered to fluctuate in the annual cycle. Next, we considered the annual fluctuation of G(P<sub>1</sub>).</p></sec><sec id="s4_5"><title>4.5. Annual Variation of G(P<sub>1</sub>) in “Model 2”</title><p>In “Model 2”, the gas concentration due to α reaction was suppressed by G(P<sub>1</sub>) in winter due to the potential power P<sub>1</sub>. On the other hand, the suppression of gas concentration was zero in summer, that is,</p><p>G(P<sub>1</sub>) = 0. Then, the periodic change of G(P<sub>1</sub>) was considered. In order to determine the annual fluctuation of G(P<sub>1</sub>), first, the periodic approximate curves Ψ<sub>1</sub>(t) and Ψ<sub>2</sub>(t) of the moving average of Ψ<sub>1</sub> and Ψ<sub>2</sub> shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) were obtained. Then, a periodic approximation curve G(P<sub>1</sub>(t)) of G(P<sub>1</sub>) was obtained. Here, we assumed that both Ψ<sub>1</sub>(t) and Ψ<sub>2</sub>(t) could be expressed by the following equations.</p><p>Ψ 1 ( t ) , Ψ 2 ( t ) = a + b sin ( 2 π t 366 ) + c cos ( 2 π t 366 ) = a + b 2 + c 2 sin ( 2 π t 366 + ϕ ) ,</p><p>ϕ = arcsin ( c b 2 + c 2 ) . (9)</p><p>Here, a, b, and c are constants, π is the geometrical constant pi and t represents time (day). Assuming that January 1 of each year in which the experiment was performed is 1, and taking into account occurrence of leap years, the value of t will be 1 to 366 (days) (<xref ref-type="fig" rid="fig7">Figure 7</xref>). As a result of simulating the periodic approximation curves of Ψ<sub>1</sub>(t) and Ψ<sub>2</sub>(t), the constants were determined as follows. In the case of Ψ<sub>1</sub>(t), ( a , b , c ) = ( − 4.713 , − 0.658 , − 2.817 ) ,and in the case of Ψ<sub>2</sub>(t), ( a , b , c ) = ( 1.308 , 0.807 , − 2.697 ) . The equation for calculating the periodic approximation curve G(P<sub>1</sub>(t)) of G(P<sub>1</sub>) from Ψ<sub>1</sub>(t) could be expressed as follows from Equation (7) and <xref ref-type="fig" rid="fig1">Figure 1</xref>6.</p><p>Ψ 1 ( t ) = 100 ln ( ( 356 − G ( P 1 ( t ) ) ) / 360 ) . (10)</p><p>Further, the expression for calculating G(P<sub>1</sub>(t)) from Ψ<sub>2</sub>(t) could be expressed as follows from Equation (8) and <xref ref-type="fig" rid="fig1">Figure 1</xref>6.</p><p>Ψ 2 ( t ) = 100 ln ( ( 344 − G ( P 1 ( t ) ) + 25.6 ) / 354 ) . (11)</p><p>Here, G(P<sub>2</sub>) = 25.6 ppm obtained by Equation (6) was used.</p><p>The G(P<sub>1</sub>(t)) calculated from Equation (10) is the gray dashed line indicated in <xref ref-type="fig" rid="fig1">Figure 1</xref>8(a), and G(P<sub>1</sub>(t)) calculated from Equation (11) is the gray dotted line, also in <xref ref-type="fig" rid="fig1">Figure 1</xref>8(a). The average of G(P<sub>1</sub>(t)) obtained by the two methods is the gray solid line in <xref ref-type="fig" rid="fig1">Figure 1</xref>8(b), which was defined as a periodic approximation curve G(P<sub>1</sub>(t)) of G(P<sub>1</sub>).</p><p>Next, using the periodic approximation curve of G(P<sub>1</sub>(t)), the approximation curves of Ψ<sub>1</sub> and Ψ<sub>2</sub> shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>(a) were obtained. Then, we attempted simulation of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub>.</p></sec><sec id="s4_6"><title>4.6. The Approximate Periodic Curves of Ψ<sub>1</sub> and Ψ<sub>2</sub>, and Comparison of the Experimental and Theoretical Values of Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub></title><p><xref ref-type="fig" rid="fig1">Figure 1</xref>9(a) shows Ψ<sub>1</sub> (red solid line) and Ψ<sub>2</sub> (red dotted line) given in <xref ref-type="fig" rid="fig7">Figure 7</xref>(a), and the results of simulating Ψ<sub>1</sub> and Ψ<sub>2</sub> from G(P<sub>1</sub>(t)) (gray solid line). The simulated results reasonably approximated the moving average calculated from the experimental values.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>9(b) shows Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub> (red squares) given in <xref ref-type="fig" rid="fig9">Figure 9</xref>. And <xref ref-type="fig" rid="fig1">Figure 1</xref>9(b)</p><p>also shows Ψ<sub>1(E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub> (gray circles) which were obtained from Ψ<sub>1</sub>,Ψ<sub>2</sub> (solid gray line) in <xref ref-type="fig" rid="fig1">Figure 1</xref>9(a). When calculating Ψ<sub>1(</sub><sub>E-CAL)Layer1</sub> and Ψ<sub>2(E-CAL)Layer2</sub>, values of Ψ<sub>3</sub> and Ψ<sub>4</sub> are required (Equation (4)). Here, as the values of Ψ<sub>3</sub> and Ψ<sub>4</sub>, the average values of the moving averages of Ψ<sub>3</sub> and Ψ<sub>4</sub> shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>(b), Ψ<sub>3</sub> = −1.534, Ψ<sub>4</sub> = −4.172, were used. At the PS apex a strange phenomenon that the non-contact effect on the biosensors differs depending on the difference between the upper and lower layers could be reproduced with a very good approximation by simulation using “Model 2”.</p></sec></sec><sec id="s5"><title>5. Conclusions and Impact</title><p>In the experiment using the PS, the biosensors were placed on the PS apex and the calibration control point, in two layers, the upper and lower. The non-contact effect on the biosensors at the PS apex (Ψ<sub>(</sub><sub>E-CAL)</sub>) was considered as the average of the non-contact effects on the lower (G<sub>E1</sub>) and upper (G<sub>E2</sub>) biosensors. This time, in examining the potential power of the PS, we focused on the difference between the upper and lower biosensors that were placed in two layers at the PS apex. As shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>, we obtained the surprising result that the non-contact effect on the upper biosensors (farther from the PS) was larger than that on the lower biosensors (closer to the PS) (p = 4.0 &#215; 10<sup>−7</sup>).</p><p>Until now, there has been little reliable academic research or collection of statistically significant data on the “pyramid power”. Since 2007, we have been conducting scientifically rigorous experiments and analyzes using biosensors to elucidate the unexplained “power” of the PS. As a result, the existence of the “pyramid power”, which was often recognized as having no scientific basis, was demonstrated with high statistical accuracy. While this field is still often regarded as heresy in the academic world, our experimental results are the world’s first truly scientific work in this field. It is expected that these results will be widely recognized in the future, and they will become part of a new research field in science, and that there will be widespread applications.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.100146-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Sheila, O. and Lynn, S. (1970) Psychic Discoveries Behind the Iron Curtain. Prentice-Hall, Inc., Upper Saddle River.</mixed-citation></ref><ref id="scirp.100146-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Patrick, F. (1973) Pyramid Power: The Science of the Cosmos. PhiSciences Press, Cottonwood.</mixed-citation></ref><ref id="scirp.100146-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Patrick, F. (1973) Pyramid Power: The Millennium Science. Earthpulse Press, Inc., Anchorage.</mixed-citation></ref><ref id="scirp.100146-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Patrick, F. (1981) Pyramid Power II: The Scientific Evidence. Innergy Publications, Tucson.</mixed-citation></ref><ref id="scirp.100146-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Max, T. and Greg, N. (1974) Pyramid Power. Destiny Books, Rochester.</mixed-citation></ref><ref id="scirp.100146-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Bill, S. and Ed, P. (1975) The Secret Power of Pyramids. Fawcett Gold Medal, New York.</mixed-citation></ref><ref id="scirp.100146-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">James, W. (1976) Using Pyramid Power. Kensington Publishing Corp., New York.</mixed-citation></ref><ref id="scirp.100146-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Norman, S. (1977) The First Practical Pyramid Book: Free Energy for Beauty, Health, Gardening, Food Dehydration, and Meditation. Sheed Andrews and McMeel, Inc., Kansas City.</mixed-citation></ref><ref id="scirp.100146-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Serge, K. (1977) Pyramid Energy Handbook. Warner Books, New York.</mixed-citation></ref><ref id="scirp.100146-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Geof, G.C. (1979) Secrets from Beyond the Pyramids. The Alternative Universe Edmonton, Alberta.</mixed-citation></ref><ref id="scirp.100146-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Bill, S. and Ed, P. (1979) Pyramid Power a New Reality. Stillpoint, Walpole.</mixed-citation></ref><ref id="scirp.100146-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Christopher, D. (1998) The Giza Power Plant: Technologies of Ancient Egypt. Bear &amp; Company, Rochester.</mixed-citation></ref><ref id="scirp.100146-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">David, H.C. (2000) Technology of the Gods: The Incredible Sciences of the Ancients. Adventures Unlimited Press, Kempton.</mixed-citation></ref><ref id="scirp.100146-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Gamal, E. (2012) The Great Pyramid System: The Blue Light. An Amazon Company, North Charleston.</mixed-citation></ref><ref id="scirp.100146-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Scott, C. and Gary, O. (2012) The Giza Prophecy. Bear &amp; Company, Rochester.</mixed-citation></ref><ref id="scirp.100146-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Zoltan, J.K. (2015) The Quantum Impulse and the Space-Time Matrix: The Power of the Hydrogen Process and the Pyramid. Trafford Publishing, Bloomington.</mixed-citation></ref><ref id="scirp.100146-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Steven, L. (2018) The Great Pyramid’s Laser Power Plant.</mixed-citation></ref><ref id="scirp.100146-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">James, E.B., James, H. and Desiree, H. (2019) Giza’s Industrial Complex: Ancient Egypt’s Electrical Power and Gas Generating Systems. Academy for Future Science, Los Gatos.</mixed-citation></ref><ref id="scirp.100146-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Rubik, B. and Jabs, H. (2016) Interactions of Pyramidal Structures with Energy and Consciousness. The Journal of Natural and Social Philosophy, 12, 259-275. https://www.researchgate.net/publication/309407219</mixed-citation></ref><ref id="scirp.100146-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Grandics, P. (2009) The Pyramid Electric Generator. Infinite Energy, No. 84, 1-4.  
https://www.researchgate.net/publication/255709759</mixed-citation></ref><ref id="scirp.100146-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Andrew, N. (1980) The Psychology of Transcendence. Dover Publications, Inc., New York.</mixed-citation></ref><ref id="scirp.100146-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Michael, S. (2002) The Skeptic Encyclopedia of Pseudoscience. ABC-Clio, Inc., Santa Barbara.</mixed-citation></ref><ref id="scirp.100146-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Terence, H. (2003) Pseudoscience and the Paranormal. Prometheus Books, New York.</mixed-citation></ref><ref id="scirp.100146-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Joe, N. (2004) The Mystery Chronicles: More Real-Life X-Files. The University Press of Kentucky, Lexington.</mixed-citation></ref><ref id="scirp.100146-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Kokubo, H., Yoichi, H., Kawano, K. and Yamamoto, M. (2013) Meditator’s Non-Contact Effect on Cucumbers. International Journal of Physical Sciences, 8, 647-651.  
https://doi.org/10.5897/IJPS2012.3800</mixed-citation></ref><ref id="scirp.100146-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2015) Discovery of an Anomalous Non-Contact Effect with a Pyramidal Structure. International Journal of Sciences, 4, 42-51.  
https://doi.org/10.18483/ijSci.714</mixed-citation></ref><ref id="scirp.100146-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2016) An Unknown Force Awakened by a Pyramidal Structure. International Journal of Sciences, 5, 45-56.  
https://doi.org/10.18483/ijSci.1038</mixed-citation></ref><ref id="scirp.100146-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2018) Discovery of Seasonal Dependence of Bio-Reaction Rhythm with Cucumbers. International Journal of Science and Research Methodology, 9, 163-175. https://www.researchgate.net/publication/331917254</mixed-citation></ref><ref id="scirp.100146-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2018) Relationship between Gas Concentration Emitted from Cut Cucumber Cross Sections and Growth Axis. International Journal of Science and Research Methodology, 9, 153-167. https://www.researchgate.net/publication/331917255</mixed-citation></ref><ref id="scirp.100146-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2019) Discovery of an Unexplained Long-Distance Effect Caused by the Association between a Pyramidal Structure and Human Unconsciousness. Journal of International Society of Life Information Science, 37, 4-16.  
https://doi.org/10.18936/islis.37.1_4</mixed-citation></ref><ref id="scirp.100146-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kawano, K. and Yamamoto, M. (2019) Potential Power of the Pyramidal Structure. Natural Science, 11, 257-266. https://doi.org/10.4236/ns.2019.118026</mixed-citation></ref><ref id="scirp.100146-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2016) Necessary Condition of an Anomalous Phenomenon Discovered by a Pyramidal Structure. Journal of International Society of Life Information Science, 34, 154-157. https://doi.org/10.18936/islis.34.2_154</mixed-citation></ref><ref id="scirp.100146-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kokubo, H., Kawano, K. and Yamamoto, M. (2019) Discovery from the Experiment on the Unexplained Functions of the Pyramidal Structure—The Phenomenon Caused by the Personal Relationship. Journal of International Society of Life Information Science, 37, 60-65.  
https://doi.org/10.18936/islis.37.1_60</mixed-citation></ref><ref id="scirp.100146-ref34"><label>34</label><mixed-citation publication-type="book" xlink:type="simple">Takagi, O., Sakamoto, M., Yoichi, H., Kawano, K. and Yamamoto, M. (2020) Meditator’s Non-Contact Effect on Cucumbers. In: Rafatullah, M., Ed., Theory and Applications of Physical Science, Vol. 3, Book Publisher International, London, Chapter 4. https://doi.org/10.9734/bpi/taps/v3</mixed-citation></ref><ref id="scirp.100146-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Atwater, F.H. (1997) Accessing Anomalous States of Consciousness with a Binaural Beat Technology. Journal of Scientific Exploration, 1, 263-274. https://www.allthingspsychic.com/AccessingAnomalousStates.html</mixed-citation></ref><ref id="scirp.100146-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Kokubo, H., Takagi, O. and Koyama, S. (2010) Application of a Gas Measurement Method—Measurement of KI Fields and Non-Contact Healing. Journal of International Society of Life Information Science, 28, 95-103.  
https://doi.org/10.18936/islis.28.1_95</mixed-citation></ref><ref id="scirp.100146-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Kokubo, H. and Yamamoto, M. (2009) Controlled Healing Power and Ways of Non-Contact Healing. Journal of International Society of Life Information Science, 27, 90-105. https://doi.org/10.18936/islis.27.1_90</mixed-citation></ref><ref id="scirp.100146-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Kokubo, H., Takagi, O., Koyama, S. and Yamamoto, M. (2011) Discussion of an Approximated Equation for Special Distribution of Controlled Healing Power around a Human Body. Journal of International Society of Life Information Science, 29, 23-34. https://doi.org/10.18936/islis.29.1_23</mixed-citation></ref><ref id="scirp.100146-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Kokubo, H. (2015) Ki or Psi—Anomalous Remote Effects of Mind-Body System. Nova Science Publishers, Inc., New York.</mixed-citation></ref><ref id="scirp.100146-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Kokubo, H., Takagi, O. and Yamamoto, M. (2009) Development of a Gas Measurement Method with Cucumber as a Bio-Sensor. Journal of International Society of Life Information Science, 27, 200-213.  
https://doi.org/10.18936/islis.27.2_200</mixed-citation></ref><ref id="scirp.100146-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Dean, R., Nancy, L., Masaru, E. and Takashige, K. (2008) Effects of Distant Intention on Water Crystal Formation: A Triple-Blind Replication. Journal of Scientific Exploration, 22, 481-493.  
https://www.researchgate.net/publication/255669110</mixed-citation></ref></ref-list></back></article>