D. Q. Zhang, S. J. Yang, G. Z. Liu And G. C. Zhang, "Fatigue Life Assessment Of Plant Drum In Service," Shandong Electric Power, Vol. 2, No. 6, 1997, Pp. 19-21+25.
has been cited by the following article:
TITLE: Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header
AUTHORS: Dongyi Li, Zhongguang Fu, Qiang Zhang, Ting He
KEYWORDS: Superheater Outlet header; Finite Element Method; Stress Concentration
JOURNAL NAME: Engineering, Vol.5 No.1B, January 15, 2013
ABSTRACT: The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.