TITLE:
Validation of the Eustachian Tube Dysfunction Questionnaire-7 in Diagnosing Patients with Eustachian Tube Dysfunction in Mulago National Referral Hospital
AUTHORS:
Yvonne Nabachwa Kuteesa, Fiona Kabagenyi, Amina Seguya, Julius Mwangi, Sandra Petit Anena, Isaiah Kalinge, Andrew Twineamatsiko
KEYWORDS:
Eustachian Tube Dysfunction, ETDQ-7, Tympanometry, Diagnostic Accuracy, Sensitivity and Specificity
JOURNAL NAME:
International Journal of Otolaryngology and Head & Neck Surgery,
Vol.15 No.6,
November
25,
2026
ABSTRACT: Introduction: Eustachian tube dysfunction is the failure of the eustachian tube to maintain pressure equalization or mucociliary clearance of the middle ear. Subjective and objective methods are clinically utilized to assess ETD. These include otoscopy, tubomanometry, tympanometry, nasopharyngoscopy and the Eustachian Tube Dysfunction Questionnaire-7. The ETDQ-7 remains underutilized and lacks validation in numerous countries, including Uganda. However, validating its accuracy could enhance patient diagnosis and management by fostering patient engagement and adherence to treatment protocols. Objective: This paper aims to determine the accuracy of ETDQ-7 in diagnosing patients with ETD based on tympanometry as an objective test in Mulago National Referral Hospital. Methods: This was a cross-sectional diagnostic accuracy study of 182 consecutive adults attending the ENT clinic. Tympanometry (the reference standard) was performed first, and the ETDQ-7 (the index test) was then administered by interviewers who were unaware of the tympanometry results. A participant was classified as reference-positive if either ear showed a Type B or Type C tympanogram on the baseline (pre-Valsalva) recording; the ETDQ-7 score was not part of the reference definition. An ETDQ-7 score of ≥14.5 was considered positive. Sensitivity, specificity, predictive values and likelihood ratios with exact 95% confidence intervals (CIs) were calculated using STATA version 14.0, and internal consistency was assessed with Cronbach’s alpha. Results: Thirty-five of the 182 participants (19.2%) were reference-positive. The ETDQ-7 had a sensitivity of 80.0% (95% CI: 63.1 - 91.6), a specificity of 97.3% (95% CI: 93.2 - 99.3), a positive predictive value of 87.5% (95% CI: 71.0 - 96.5), a negative predictive value of 95.3% (95% CI: 90.6 - 98.1), a positive likelihood ratio of 29.4 (95% CI: 11.0 - 78.4) and a negative likelihood ratio of 0.21 (95% CI: 0.11 - 0.40). Seven of the 35 reference-positive participants (20%) were not identified by the questionnaire. Internal consistency was good (Cronbach’s alpha = 0.827). Conclusion: Against an imperfect tympanometric reference standard in this referral-clinic sample, the ETDQ-7 showed high specificity and moderate sensitivity. It may serve as a useful clinical adjunct for identifying ETD where tympanometry is unavailable, but a negative score does not reliably exclude ETD, and further validation in primary-care and other settings is needed before it can be recommended as a stand-alone diagnostic tool in Uganda.