ABSTRACT: The prediction of the effective thermomechanical properties of heterogeneous composites is essential for the design and optimization of cement-based materials with improved durability and energy performance. In this study, a micromechanical framework based on Eshelby’s equivalent inclusion theory and the Mori-Tanaka homogenization scheme is proposed to jointly estimate the effective Young’s modulus and the effective thermal conductivity of particulate composites. The model considers spherical inclusions embedded in a continuous matrix and is extended to account for the presence of an interfacial transition zone (ITZ) surrounding the inclusions, via the Hervé-Zaoui coated-inclusion model. Three microstructural architectures are compared: an ideal single-inclusion system, a fully ITZ-affected core-shell system, and a mixed system combining both populations. The predicted effective properties are verified against the Hashin-Shtrikman and Voigt-Reuss bounds. The comparison is carried out at matched Young’s-modulus and conductivity ratios: the inclusion-to-matrix and ITZ-to-matrix ratios of
E
and of
λ
are set equal, whereas the bulk- and shear-modulus ratios remain conditional on the adopted Poisson’s ratios. The aggregate-core volume fraction
f
a
is held fixed across the architectures and the ITZ fraction is reported separately, so that the differences isolate the effect of the ITZ from that of a reduced aggregate content. At
f
a
=0.6
(ITZ fraction 0.22), the ITZ reduces the effective Young’s modulus by 9.4% and the effective thermal conductivity by 7.6%. The gap of 1.8 percentage points is modest and sensitive to the residual mismatch of the inputs: it falls to about 0.9 points when the ITZ contrasts and the Poisson’s ratios are matched exactly. It is consistent with the two-channel (spherical and deviatoric) nature of mechanical load transfer as opposed to the single-channel nature of thermal conduction. The conductivity reduction is a loss for conductive applications but a benefit for insulating concretes, whereas the stiffness reduction is a loss in both cases. The mixed inclusion system roughly halves both reductions (to 4.8% and 3.9%), offering a lever to balance structural stiffness against thermal insulation in cementitious composites. At high inclusion content the results are Mori-Tanaka estimates for a continuous matrix and are not validated against dense coated or mixed packings.