TITLE:
Investigation of the Tissue Equivalence of Some Polymer Gel Dosimeters: A Monte Carlo Study
AUTHORS:
Hikmet Osman, Mahmoud Khalawi
KEYWORDS:
Polymer Gel Dosimetry, Monte Carlo Simulation, EGSnrc, PENELOPE, Tissue Equivalence, Radiotherapy
JOURNAL NAME:
Open Access Library Journal,
Vol.13 No.11,
November
20,
2026
ABSTRACT: The radiological properties of four polymer gel dosimeters-MAGIC, MAGAS, MAGAT, and PAGAT-used in radiotherapy dosimetry were investigated in this study. Two independent Monte Carlo codes, EGSnrc and PENELOPE, were employed to simulate photon and electron radiation transport. Mass attenuation coefficients, mass stopping powers, CSDA ranges, interaction cross sections (interaction probabilities), and depth-dose distributions were calculated for each gel over the energy range of 10 keV to 30 MeV and compared against one another and against soft tissue. The total mass attenuation coefficients, interaction probabilities, mass stopping powers, and CSDA ranges of the polymer gels were found to agree closely with those of soft tissue, with differences of only 0.05% - 0.1% across the entire energy range. Depth-dose curves for monoenergetic 6 MeV electron and photon beams, evaluated over depths of 0.05 - 20 cm, showed deviations of approximately 1% or less between the gels and soft tissue. These results demonstrate that all four polymer gels exhibit strong radiological equivalence to soft tissue, with MAGAT showing the closest agreement. Accordingly, MAGIC, MAGAS, MAGAT, and PAGAT gels can be considered reliable soft-tissue-equivalent dosimeters for radiotherapy applications.