TITLE:
When Eyelid Height Is Not Enough: Margin Reflex Distance Is an Incomplete Predictor of Patient Satisfaction Following Aponeurotic Ptosis Surgery
AUTHORS:
Christine Safieh, Gabriella Guevara, George Kalantzis, Bernard Y. P. Chang
KEYWORDS:
Blepharoptosis, Ptosis Surgery, MRD1, Patient Satisfaction, Patient-Reported Outcomes, Levator Advancement
JOURNAL NAME:
Open Journal of Ophthalmology,
Vol.16 No.4,
November
17,
2026
ABSTRACT: Purpose: Margin reflex distance 1 (MRD1) is widely used as an objective measure of anatomical success following ptosis surgery. However, restoration of eyelid height does not always correspond with patient-perceived surgical success. This study evaluated the relationship between postoperative improvement in MRD1 and patient satisfaction following aponeurotic ptosis surgery and explored the limitations of MRD1 as a predictor of patient-reported outcome. Methods: A retrospective observational cohort study was performed using data from a prospectively maintained departmental audit of adult patients undergoing anterior levator aponeurosis advancement at a tertiary oculoplastic centre between January 2017 and October 2022. Unilateral and bilateral, primary and revision procedures were eligible. The primary analysis included 107 operated eyes with complete preoperative and postoperative MRD1 measurements and documented postoperative satisfaction. Associations between change in MRD1 (ΔMRD1) and postoperative satisfaction were evaluated using univariable and multivariable logistic regression. Results: The complete-case cohort comprised 107 operated eyes, of which 93 (86.9%) were satisfied and 14 (13.1%) were dissatisfied. Mean postoperative improvement in MRD1 was greater in satisfied than dissatisfied eyes (2.42 ± 1.15 mm versus 1.82 ± 1.27 mm). Each 1-mm increase in ΔMRD1 was associated with higher odds of satisfaction on univariable analysis (OR 1.59, 95% CI 0.95 - 2.67; p = 0.076), but ΔMRD1 was not independently associated with satisfaction after adjustment for age, sex, unilateral versus bilateral surgery, revision status and preoperative MRD1 (adjusted OR 1.25, 95% CI 0.69 - 2.26; p = 0.455). Of 89 eyes achieving postoperative MRD1 > 2 mm, nine (10.1%) were nevertheless associated with dissatisfaction. Conclusions: Greater postoperative improvement in MRD1 was associated with higher patient satisfaction, but objective eyelid height alone did not fully explain patient-perceived success. Outcome assessment after ptosis surgery should combine anatomical measurements with patient-reported outcomes and, where feasible, standardised photographic assessment.