Article citationsMore>>
Hamdy, F.C., Donovan, J.L., Lane, J., Mason, M., Metcalfe, C., Holding, P., Davis, M., Peters, T.J., Turner, E.L. and Martin, R.M. (2016) 10-Year Outcomes after Monitoring, Surgery, or Radiotherapy for Localized Prostate Cancer. The New England Journal of Medicine, 375, 1415-1424.
https://doi.org/10.1056/NEJMoa1606220
has been cited by the following article:
-
TITLE:
Dosimetric Effects Due to Inter-Observer Variability of Organ Contouring When Utilizing a Knowledge-Based Planning System for Prostate Cancer
AUTHORS:
Han Liu, Christopher Amaloo, Benjamin Sintay, David Wiant
KEYWORDS:
Inter-Observer Variability of Organ Contouring, Knowledge-Based Treat-ment Planning, Prostate Radiotherapy
JOURNAL NAME:
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology,
Vol.10 No.2,
May
18,
2021
ABSTRACT: Purpose: Radiotherapy is a widely accepted standard of care for early-stage prostate
cancer, and it is believed that the plan quality and treatment outcome are
associated with contour accuracy of both the target and organs-at-risk (OAR).
The purposes of this study are to 1) assess geometric and dosimetric
uncertainties due to inter-observer contour variabilities and 2) evaluate the
effectiveness of geometric indicators to predict target dosimetry in prostate
radiotherapy. Methods: Twenty prostate patients were selected for this
retrospective study. Five experienced clinicians created unique structure sets
containing prostate, seminal vesicles, bladder, and rectum for each patient. A
fully automated script and knowledge-based planning routine were utilized to
create standardized and unbiased plans that could be used to evaluate changes
in isodose distributions due to inter-observer variability in structure
segmentation. Plans were created on a “gold-standard” structure set, as well as
on each of the user-defined structure sets. Results: Inter-observer
variability of contours during structure segmentation was very low for clearly
defined organs such as the bladder but increased for organs without
well-defined borders (prostate, seminal vesicles, and rectum). For plans
generated with the user-defined structure sets, strong/moderate correlations
were observed between the geometric indicators for target structure agreement
and target coverage for both low-risk and intermediate-risk patient groups,
while OAR indicators showed no correlation to final dosimetry. Conclusions: Target delineation is crucial in order to maintain adequate dosimetric coverage
regardless of the associated inter-observer uncertainties in OAR contours that
had a limited impact upon final dosimetry.