Article citationsMore>>
Ohman, A., Mardbrink, E.-L., Orefelt, C., Seager, A., Tell, L. and Klackenberg, A. (2013) The Physical Therapy Assessment and Management of Infants with Congenital Muscular Torticollis. A Survey and a Suggested Assessment Protocol for CMT. Journal of Novel Physiotherapy, 3, 165.
http://dx.doi.org/10.4172/2165-7025.1000165
has been cited by the following article:
-
TITLE:
A Craniometer with a Headband Can Be a Reliable Tool to Measure Plagiocephaly and Brachycephaly in Clinical Practice
AUTHORS:
Anna Öhman
KEYWORDS:
Plagiocephaly, Brachycephaly, Measurement, Craniometer, Headband, Infant
JOURNAL NAME:
Health,
Vol.8 No.12,
September
27,
2016
ABSTRACT: Objective: The aim of the study was to determine the intra- and inter-reliability for measuring infants with plagiocephaly and brachycephaly with a craniometer when using a marked headband as landmarks. Subjects: Six physiotherapists and eight infants participated in the study. Methods: The physiotherapists measured all infants twice; each infant was measured with the same headband and craniometer. The physiotherapists were blinded to measurements carried out by their colleagues. The infants with their parents changed places in the room to minimize the possibility that the physiotherapists would remember their first measurements of any infant. Results: There was a high intra- and inter-reliability, for intra-reliability ICC 0.96 to 0.99 and for inter-reliability ICC 0.98. Conclusion: It is possible to achieve a high intra- and inter-reliability when using a headband and craniometer when measuring cranial vault asymmetry for plagiocephaly and cephalic ratio for brachycephaly.