A. Bohme, “Ozone Technology of German Industrial Enterprises,” Ozone: Science & Engineering, Vol. 21, 1999, pp. 163-176. http://dx.doi.org/10.1080/01919519908547250
has been cited by the following article:
TITLE: Effect of Generating Heat on Ozone Generation in Dielectric Cylinder-Cylinder DBD Ozone Generator
AUTHORS: Surapon Boonduang, Pichet Limsuwan
KEYWORDS: Cylinder-Cylinder DBD; Ozone Generator; Ozone Concentration; Thermal Camera
JOURNAL NAME: Energy and Power Engineering, Vol.5 No.9, November 20, 2013
ABSTRACT: A cylinder-cylinder dielectric-barrier discharge (DBD) ozone generator has been developed. The ozone concentration was measured at an oxygen pressure of 1.02 atm and an oxygen flow rate of 12 L/min. The heat generated in the ozone tube during the operation of the ozone generator was investigated using a thermal camera. The infrared (IR) images and corresponding temperatures of the ozone tube surfaces at different operating times were observed. The IR images showed the generating of the inhomogeneous heat-up along the ozone tube surface which results in the decrease of the ozone production efficiency.