![]() Vol.1, No.2, 5-7 (2013) Open Journal of Emergency Medicine http://dx.doi.org/10.4236/ojem.2013.12002 Current situation of mechanical CPR devices in donors after cardiac death Alonso A. Mateos Rodríguez1*, José María Navalpotro Pascual1, Vicnete Sanchez Brunete Ingelmo1, Francesc Carmona Jiménez2 1Servicio de Urgencias Médicas de Madrid SUMMA112 (Emergency Medical Services of Madrid), Madrid, Spain; *Corresponding Autho r : [email protected] 2Servei Emergencies Mediques (Emergency Medical Services), Barcelona, Spain Received 17 October 2013; revised 19 November 2013; accepted 5 December 2013 Copyright © 2013 Alonso A. Mateos Rodríguez et al. This is an open access article distributed under the Creative Commons Attribu- tion License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. In accordance of the Creative Commons Attribution License all Copyrights © 2013 are reserved for SCIRP and the owner of the intellectual p r operty Alonso A. Mateos Rodríguez et al. All Copyright © 2013 are guarded by law and by SCIRP as a guardian. ABSTRACT Mechanical CPR (cardi o pu lm on ary r es us ci tation) devices help performing correct chest compres- sions in the event of a cardiorespiratory arrest. These devices are comfortable and useful, they keep chest compression following the recom- mendations as they do not depend on interper- sonal variability, they do not get tired, their use is simple and one of the rescuers is released from this task, thus facilitating the assistance. Besides, the ir use in tran sport c onditi ons ma kes it safer. However, when coming to results, these mechanical CPR devices have not clearly dem- onstrated such an advantage, neither in the field of cardiac arrest, nor in organ preservation in the case of d onors after cardiac death . In donors after cardiac death they are widely used by most of the emergency services involved, but a num- ber of injuries produced in lungs during the ear- ly years of their use have made it controversial. In this paper w e make a review of the road trav- eled by mechanical CPR dev ices a nd of the main articles which mark the way. Keywords: Emergency Medical Services; Donors after Cardiac Death; Cardi oc o mpressors 1. INTRODUCTION In the last few years, several mechanical devices have been developed to replace manual cardiac massage in the event of a cardiorespiratory arrest. These devices have shown to improve quality of cardiopulmonary resuscita- tion [1] and, in some cases, an improvement of short- term survival has been proven [2,3]. Two devices are currently being used: LUCAS©, Lung University Cardiac Arrest System, from the company Physio-Control, and Autopulse©, from Zoll. There is a third device in the market from the company Corpuls based on a piston-arm with a base recalling the o ld devices, but improved. LUCAS© is a piston system with a suction cup which attaches the patient chest in a specific point. By means of oxygen or compressed air in version 1 and rechargeable batteries in version 2, it exerts pressure up and down. Autopulse© exerts the same pressure on the chest, but does so by means of a load distribution band which em- braces the patient trunk, and uses rechargeable batteries. Both devices have two possibilities for performing chest compressions: rhythm 30:2 or continuous massage, and they present as an additional advantage the fact that one of the rescuers involved in resuscitation is released from this task. Their use and placement are very simple. They are widely used by most of the emergency services in cardiopulmonary arrest cases and in organ donation in asystole [4]. Due to its cost it is complicated for these devices to be shipped with the whole fleet of mobile re- sources, therefore, most emergency services carry them on a special vehicle featured in the scene at the request of the professionals. Their primary use is intended for the return of spontaneous circulation, and if this is not achi- eved, devices are used for the transfer of the potential donor if this is the case. In Spain, the Organización Nacional de Trasplantes (National Transplant Organization), in its consensus document for promoting donors after cardiac death, rec- ommends the use of these devices as a way of imple- menting programs of donation in asystole. At European level, a document is being drafted in the same direction of the Spanish one recommending their use as well [5]. Copyright © 2013 SciRes. OPEN ACC ESS ![]() A. A. M. Rodríguez et al. / Open Journ al of Emergency Medicine 1 (2013) 5-7 6 Many studies have been published referring to the pos- sible injuries that mechanical CPR devices could cause to patients. Smekal et al. already proved that injuries pro- duced by these devices were similar to those found on cases of manual chest compression [6]. However, in spite of studies like this, the repu tation of the mechanical CPR devices was determined on the side of injuries. In this review we want to debunk this myth on the basis of sev- eral articles published in the last few years. 2. MECHANICAL CPR DEVICES IN CARDIORESPIRAT OR Y ARREST Mechanical CPR devices have not yet demonstrated a clear return of spontaneous circulation. There are two studies which are working on th is objective in a random- ized way. CIRC Trial studies the Autopulse©, and in pre- liminary data it has proven to have the same rate of sur- vival to hospital disch arg e than high-qu ality manual mas- sage. The problem is, who can achieve this high-quality manual massage for an extended time [7]. So does LINC Trial with LUCAS©, the LINC study showed similar short-term survival rates for LUCAS (23.6%) and man- ual (23.7%) chest compressions. At 6-months, 8.5% of the patients treated with LUCAS were alive with good neurological outcomes compared to 7.6% in the manual group [8]. Despite not having shown a clear improvement in ROSC [9] (return of spontaneous circulation) or in sur- vival to hospital discharge, they make it when it comes to optimum fulfillment of protocols [10,11] and safety in cardiopulmonary resuscitation [12,13]. Only these two aspects, on equal terms with manual chest compression, already justify their use. 3. MECHANICAL CPR DEVICES AS A PRESERVATION METHOD FOR THE DONORS AFTE R CARDIAC DEATH In 2010 we published an article where we evaluated the efficiency of CPR devices as an organ preservation method [14]. We compared two groups of donors after cardiac death of approximately 40 cases each; one group was assisted with CPR devices and the other one with manual chest compression. The rate of kidneys and the rate of organs and tissues per donor were significantly lower in the group of donors assisted with mechanical CPR devices. These data made us wonder if the use of these devices was correct, and we started to study them further. 4. CPR DEVICES IN KIDNEY GRAFTS The limits of our study were clear, since we collected just a few cases and we only evaluated transplanted or- gans without considering their evolution thereafter. In detail, and if we just evaluate kidney grafts, data offered by a group of donors assisted with CPR devices vs man- ual cardiac massage are almost the same. The cases of primary graft failure were similar in both groups and present a very low frequency, around 8% [15]. Later, it has been observed that long-term function of kidney grafts is very similar in both groups of patients. Data from a cohort of 50 other donors divided into CPR de- vices and non-CPR devices reveal that, after 6 and 12 months, the renal function (creatinine) was somewhat higher in the group assisted with CPR devices, but not reaching pathological levels and without being statisti- cally significant [16]. In a similar study, in which LU- CAS© was evaluated, results marked a clear advantage in favour of CPR devices [17], objectifying an improve- ment of 0.3 kidneys transplanted per donor in the CPR devices group and a decrease of 32.9% of kidney grafts discarded because of poor perfusion. It seems proved that CPR devices do not affect further evolution of kidney grafts, actually, they may even improve it. 5. CPR DEVICES IN LUNG GRAFTS As a matter of fact, injuries produced by CPR devices usually appeared in lungs, as it can be easily understood because of the pressure exerted over them during car- diopulmonary resuscitation. These injuries have been commented many times, but never published. Numerous articles have appeared objectifying the presence of trau- matic injuries on the chest and lungs of patients assisted with mechanical CPR devices, and in all of them results are similar: there is no significant difference between injuries produced by manual chest compression and those caused by mechanical devices [6,18-20]. Even in a number of lungs evaluated for transplantation from pa- tients which had been assisted with CPR devices, major injuries were not noticed, or at least, not that major inju- ries as to discard the lungs for transplantation. In patients considered as donors 8 pathological bronchoscopes were objectified, 3 of them with bronchial aspiration and 5 with blood-borne secretions; no rib fractures were no- ticed but there appeared 2 cases of sternal fracture. Inju- ries were never described as serious, and they were never a potential reason for discarding the organ for transplan- tation. This kind of lung grafts presents a highly satisfac- tory evolution thereafter. Out of 20 patients receiving lungs from donors after cardiac death, 18 survived the first month [21]. Most of these lungs had been subjected to CPR devices. 6. CONCLUSION Even though it seems that at first mechanical CPR de- vices had been associated with the presence of injuries in organs of patients assisted with them, and that their use Copyright © 2013 SciRes. OPEN ACC ESS ![]() A. A. M. Rodríguez et al. / Open Journ al of Emergency Medicine 1 (2013) 5-7 Copyright © 2013 SciRes. OPEN AC CESS 7 in donor processes seemed to decrease the number of suitable organs, these data have not been confirmed by further investigations. While it is true that in few occa- sions have they shown an improvement compared to manual chest compression, the advantages that they offer make their use generalized and unquestionable. Further studies with a larger number of populations are n eed ed to know in detail the results of these mechanical CPR de- vices in organs which are candidates to be transplanted. REFERENCES [1] Nielsen, N., Sandhall, L., Schersten, F., Friberg, H. and Olsson, S.E. (2005) Successful resuscitation with mecha- nical CPR, therapeutic hypothermia and coronary inter- vention during manual CPR after out-of-hospital cardiac arrest. Resuscitation, 65, 111-113. http://dx.doi.org/10.1016/j.resuscitation.2004.11.007 [2] Casner, M., Anderson, D., et al. (2005) Preliminary report of the impact of a new CPR assist device on the rate of return of spontaneous circulation in out of hospital car- diac arrest. Pre-Hospital Emergency Medicine, 9, 61-67. http://dx.doi.org/10.1080/10903120590891714 [3] Steen, S., L iao, Q., Pierre, L., Paskevicius, A. and Sjoberg, T. (2002) Evaluation of LUCAS, a new device for auto- matic mechanical compression and active decompression resuscitation. Resuscitation, 55, 285-599. http://dx.doi.org/10.1016/S0300-9572(02)00271-X [4] (2012) Consent document for asystole donors in Spain. Organización Nacional de Trasplantes. [5] ESOT (2013) 6th International Conference Donors after Cardiac Death. European Society for Organ Transplanta- tion, Paris. [6] Sme kal , D ., Johansson, J., Huzevka, T. and Rubert sson , S. (2009) No difference in autopsy detected injuries in car- diac arrest patients treated with manual chest compres- sions compared with mechanical compressions with the LUCAS™ device—A pilot study. Resuscitation, 80, 1104-1107. http://dx.doi.org/10.1016/j.resuscitation.2009.06.010 [7] (2012) CIRC trial. European Resuscitation Council Con- gress, Vienna. [8] (2103) LINC trail. Oral comunication. European Cardi- ology Congress, Amsterdam. [9] Ballesteros Peña, S. (2013) Survival after prehospital car- diac arrest in Spain: A review of the literature. Emergen- cias, 25, 137-142. [10] Wigginton, J.G., Isaacs, S.M. and Kay, J.J. (2007) Me- chanical devices for cardiopulmonary resuscitation. Cur- rent Opinion in Critical Care, 13, 273-279. http://dx.doi.org/10.1097/MCC.0b013e328155d4ab [11] Carmona Jiménez, F., Palma Padró, P., Soto García, M.A. and Rodríguez Venegas, J.C. (2012) Cerebral blood flow measured by transcranial doppler ultrasound during man- ual chest wall or automated LUCAS-2 compressions during cardiopulmonary resuscitation. Emergencias, 24, 47-49. [12] Olasveengen, T.M., Wik, L. and Steen, P.A. (2008) Qual- ity of cardiopulmonary resuscitation before and during transport in out-of-hospital cardiac arrest. Resuscitation, 76, 970-976. http://dx.doi.org/10.1016/j.resuscitation.2007.07.001 [13] Camacho Leis, C., Almagro González, V., De Elías Hernández, R., Esquilas Sánchez, O., Moreno Martín, J.L., Muñoz Hermosa, E.J., et al. (2013) Feedback on chest compression quality variables and their relationship to rate of return of spontaneous circulation. Emergencias, 25, 99-104. [14] Mateos Rodríguez, A.A., Navalpotro Pascual, M.J., Mar- tín Maldonado, M.E., Barba Alonso, C., Pardillos Ferrer, L. and Andrés Belmonte, A. (2010) Mechanical cardio- pump use in organ donation after prehospital cardiac death, Emergencias, 22, 264-268. [15] Mateos-Rodriguez, Navalpotro-Pascual, J.M., Pardillos- Ferrer, L. and Martin-Maldonado (2010) Cardiac life me- chanical support in extrahospitalary donors after cardiac dead. Resuscitation, 81, 904-905. http://dx.doi.org/10.1016/j.resuscitation.2010.09.260 [16] Mateos-Rodríguez, A.A., Navalpotro-Pascual, J.M. and Andres-Belmonte, A. (2013) Donor after cardiac death kidney graft under mechanical cardiac compression evo- lution. Resuscitation, 84, 117-119. http://dx.doi.org/10.1016/j.resuscitation.2013.04.021 [17] Carmona Jiménez, F., Ruiz Arránz, A., Palma Padró, P., Soto García, A., Alberola Martín, M. and Saavedra Esco- bar, S. (2012) Use of the Lucas mechanical chest com- pression device in an asystolic organ donation program: effect on kidney perfusion and organ procurement and transplantation rate. Emergencias, 24, 366-371. [18] Menzies, D., et al. (2010) Does the LUCAS device result in increased injury during CPR? Resuscitation, 81, S20. http://dx.doi.org/10.1016/j.resuscitation.2010.09.092 [19] Xanthos, T., et al. (2010) A comparison of autopsy de- tected injuries in a porcine model of cardiac arrest treated with either manual or mechanical chest compressions. European Journal of Emergency Medicine, in Press. [20] Englund, E., et al. (2008) Injuries after cardiopulmonary resuscitation: A comparison between LUCAS mechanical CPR and standard CPR. Resuscitation, 77, AS-036. http://dx.doi.org/10.1016/j.resuscitation.2008.03.050 [21] Rod r í g ue z , A. A .M., Pascual, J. M.N. and del Río Gal l e g o s, F. (2013) Lung transplant of extrahospitalary donor after cardiac death. The American Journal of Emergency Med- icine, 31, 710-711. http://dx.doi.org/10.1016/j.ajem.2012.10.034 |